Prediction of Clothing Thermal Insulation and Moisture Vapour Resistance of the Clothed Body Walking in Wind
|
|
- Grace Craig
- 5 years ago
- Views:
Transcription
1 Ann. Occup. Hyg., Vol. 50, No. 8, pp , 2006 # 2006 The Author Published by Oxford University Press on behalf of the British Occupational Hygiene Society doi: /annhyg/mel050 Prediction of Clothing Thermal Insulation and Moisture Vapour Resistance of the Clothed Body Walking in Wind XIAOMING QIAN 1,2 and JINTU FAN 1 * 1 Institute of Textiles and Clothing, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong; 2 School of Textiles, The Tianjin Polytechnic University, Tianjin, China Received 2 June 2005; in final form 30 May 2006; published online 20 July 2006 Clothing thermal insulation and moisture vapour resistance are the two most important parameters in thermal environmental engineering, functional clothing design and end use of clothing ensembles. In this study, clothing thermal insulation and moisture vapour resistance of various types of clothing ensembles were measured using the walking-able sweating manikin, Walter, under various environmental conditions and walking speeds. Based on an extensive experimental investigation and an improved understanding of the effects of body activities and environmental conditions, a simple but effective direct regression model has been established, for predicting the clothing thermal insulation and moisture vapour resistance under wind and walking motion, from those when the manikin was standing in still air. The model has been validated by using experimental data reported in the previous literature. It has shown that the new models have advantages and provide very accurate prediction. Keywords: clothing physical characteristics; moisture vapour resistance; prediction model; thermal insulation; walking-able sweating manikin INTRODUCTION Clothing thermal insulation and moisture vapour resistance are two most important parameters in thermal environmental engineering, functional clothing design and end use of clothing ensembles. They are intrinsic properties of clothing depending on the fabric properties, garment(s) style and fitting, and are affected by body posture, body motion and environmental conditions. The thermal insulation and moisture vapour resistance can be measured by taking measurements on human subjects. This method gives realistic results, but requires sophisticated equipment and is time consuming, and the measured values may also have large variability. Human-shaped thermal manikins which can simulate the heat and mass transfer between human body and environment have therefore been developed for the purpose. Measurements on thermal manikins are more reproducible, but the manikins are generally very expensive and very few can simulate *Author to whom correspondence should be addressed. tcfanjt@inet.polyu.edu.hk perspiration effectively. So it is desirable to predict the clothing thermal insulation I t and moisture vapour resistance R t, not only because of the limitations of measuring these parameters on human subjects and thermal manikins, but also because of the fact that it is practically impossible to measure I t and R t for endless clothing ensembles under the different body movement and various environment conditions. Although considerable work has been carried out so far for predicting the clothing thermal insulation and moisture vapour resistance under various conditions (Spencer-Smith, 1977a,b; Lotens and Havenith, 1991; ISO,1995; Holmer et al., 1999; Nilssion et al., 2000), the reduction of thermal insulation or moisture vapour resistance induced by wind in the existing models was considered in very different forms. Heat and mass transfer and its interaction in clothing system are very complex processes. In order to predict or achieve the optimum performance with regards to clothing thermal comfort, knowledge of the effects of body motion and environmental parameters, especially wind velocity and walking speed, is essential. In this study, clothing thermal insulation and moisture vapour resistance of various types of clothing 833
2 834 X. Qian and J. Fan ensembles were measured using the walking-able sweating manikin, Walter (Fan and Qian, 2004) under various environmental conditions and walking speeds. Based on an extensive experimental investigation and an improved understanding of the effects of body activities and environmental conditions, a simple but effective direct regression model has been established for predicting the clothing thermal insulation and moisture vapour resistance under wind and walking motion from those when the manikin was standing in still air. 0ms 1 (standing) to 2.7 km h 1 by adjusting AC frequency of the power supply to the motor that drives the motion. Unlike most existing manikins, Walter has thermal insulation and moisture vapour resistance measured simultaneously. With this manikin, the total thermal insulation I t and moisture vapour resistance R t of clothing can be measured and calculated by the following equations: I t ¼ A s ðt s T a Þ ð1þ H d EXPERIMENTAL DESIGN AND RESULTS H d ¼ H s þ H p H a H e ð2þ Description of clothing ensembles In the present study 32 sets of clothing ensembles were tested. The clothing ensembles consisted of the same pair of pants, but vary in the top garments. The pants were a casual pair from Giordano, made of a fabric with a composition of 98% cotton and 2% lycra. The top garments of the clothing ensembles are described in Tables 1 and 2. In Table 2, Jacket 1 and Jacket 2 represent a leisure jacket and a jacket in which two layers of fabric are combined, respectively. The thickness and the air permeability apply to the shell fabric, measured using the FAST system (SiroFAST, 1989) and ASTM D method (ASTM Book of Standards, 2004). The garment fit index is defined as the areaweighted average of the percentage difference between the inner circumferences of different parts of the garment and the corresponding circumferences of body. Experimental conditions and results Figure 1 shows a picture of the sweating fabric manikin, Walter (Fan and Chen, 2002; Fan and Qian, 2004) used for the investigation. Walter has a man s body; its size and configurations are similar to a typical Chinese man. Walter simulates perspiration using a waterproof, but moisture-permeable, fabric skin, which holds the water inside the body, but allows moisture vapour to pass through the skin. Walter achieves a body temperature distribution similar to a real person by having warm water at the body temperature (37 C) pumped from its centre to its extremities. The mean skin temperature of Walter can be adjusted by regulating the pumping rate of the pumps inside the manikin. The regulation is performed by altering the frequency of the power supply to the pumps. Walter s skin can be unzipped and interchanged with different versions to simulate different rates of perspiration. Water is supplied automatically and water loss by perspiration is measured in real time. Walter s arms and legs can be motorized to simulate walking motion. The walking speed may be changed from R t ¼ A s ðp ss p sa RH a =100Þ R es ð3þ H e H e ¼ lq ð4þ where, I t and R t are, respectively, the total thermal insulation (m 2 CW 1 ) and the total moisture vapour resistance (Pa m 2 W 1 ) of clothing ensembles, respectively. H d is the dry heat loss from the manikin (W); H s is the heat generated from the heating elements in the manikin (W); H p is the heat generated from the pump; H a is the energy required to heat the water supplement to manikin s body temperature (W) and H e is the evaporative heat loss from skin to the environment (W). T a and T s are the environmental temperature and the area-weighted mean skin temperature in degrees centigrade ( C). A s is the body (manikin) surface area (m 2 ). p sa and p ss are the saturated moisture vapour pressure (Pa) at environment temperature and at skin temperature, respectively. RH a is the relative humidity of the environment in percent (%). Q is the water loss (or perspiration rate ) from the manikin (g h 1 ). R es is the moisture vapour resistance of the manikin skin (8.6 Pa m 2 W 1 ) (Qian and Fan, 2005). All tests were conducted in the climatic chamber under the environmental temperature of C and humidity of 50 5%. Each of the 32 sets of clothing ensembles was tested under six levels of wind velocity (V wind = 0.22, 0.85, 1.69, 2.48, 3.12 and 4.04 m s 1, with V wind = 0.22 m s 1 representing the no wind condition) when the manikin was in standing position. At the wind velocity of 0.22 and 2.48 m s 1, the clothing ensembles were also tested at four levels of walking motion (V walk = 0, 0.23, 0.46 and 0.69 m s 1 with V walk = 0ms 1 representing the standing position). So for each clothing ensemble, there are 12 cases investigated. With overnight operation, it took about 2 days to complete all measurements for each clothing ensemble. Experimental results of the measurements are listed in Supplementary Table 2 in the on-line Supplementary Material to this article.
3 Prediction of clothing thermal insulation 835 Table 1. Description of clothing ensembles tested in the present study CL_ID Label of Description clothing 1 A S size knitting jacket, casual pants 2 B M size knitting jacket, casual pants 3 C L size knitting jacket, casual pants 4 D XXL size knitting jacket, casual pants 5 E S size denim jacket, casual pants 6 F M size denim jacket, casual pants 7 G L size denim jacket, casual pants 8 H XXL size denim jacket, casual pants 9 I S size poplin jacket, casual pants 10 J M size poplin jacket, casual pants 11 K L size poplin jacket, casual pants 12 L XXL size poplin jacket, casual pants 13 M PET napping jacket, casual pants 14 N Oxford woven cotton long-sleeve shirt, casual pants 15 O Oxford woven cotton long-sleeve army uniform, casual pants 16 P Two-layer design windbreaker comprised of nylon shell and PET mesh lining, casual pants 17 Q Dacron shell with PET bedding long-sleeve shirt, casual pants 18 R One-layer design PU coated windbreaker (leisure jacket), casual pants 19 C+S Vest and underwear brief, cotton short T-shirt, L size knitting jacket, casual pants 20 M+S Vest and underwear brief, cotton short T-shirt, PET napping jacket, casual pants 21 N+S Vest and underwear brief, cotton short T-shirt, Oxford woven cotton long-sleeve shirt, casual pants 22 O+S Vest and underwear brief, cotton short T-shirt, Oxford woven cotton long-sleeve army uniform, casual pants 23 G+S Vest and underwear brief, cotton short T-shirt, L size denim jacket, casual pants 24 K+S Vest and underwear brief, cotton short T-shirt, L size poplin jacket, casual pants 25 P+S Vest and underwear brief, cotton short T-shirt, Two-layer design windbreaker comprised of nylon shell and PET mesh lining, casual pants 26 Q+S Vest and underwear brief, cotton short T-shirt, Dacron shell with PET bedding long-sleeve shirt, casual pants 27 R+S Vest and underwear brief, cotton short T-shirt, one-layer design PU coated windbreaker (leisure jacket), casual pants 28 U+S Vest and underwear brief, cotton short T-shirt, PU coated breathable army outdoor leisure jacket, casual pants 29 V+S Vest and underwear brief, cotton short T-shirt, two-layer jacket comprised of 80% nylon/20%pet napping lining and PET poplin shell, casual pants 30 U+S +T+N Vest and underwear brief, cotton short T-shirt, Oxford woven cotton long-sleeve shirt, long cotton sweat pants, PU coated breathable army outdoor leisure jacket, casual pants 31 V+S +T+N Vest and underwear brief, cotton short T-shirt, Oxford woven cotton long-sleeve shirt, long cotton sweat pants, two-layer jacket comprised of 80% nylon/20% PET napping lining and PET poplin shell, casual pants 32 W+S Vest and underwear brief, cotton short T-shirt, long cotton sweat pants, nylon film leisure jacket S Vest and underwear brief and with short T-shirt, cotton T Sweat pants, cotton Note: CL_ID represents a clothing ensemble label denoting which clothing ensemble was clothed on manikin. BUILDING A NEW DIRECT REGRESSION PREDICTION MODEL Effect of wind velocity In the existing prediction models, the reduction of thermal insulation or moisture vapour resistance by wind was considered in very different forms. Spencer-Smith (1977a,b) used a linear relationship, Loten and Havenith (1991) used the square root function, whereas Holmer et al. (1999) and Nilsson et al. (2000) used a complex exponential function to model the effect of wind velocity. It is therefore necessary to investigate the best way to model the effect of wind velocity before an improved prediction model can be established. Figure 2a and b plot the clothing thermal insulation and moisture vapour resistance against the
4 836 X. Qian and J. Fan Table 2. Description of clothing ensembles tested in the present study CL_ID Label of clothing Style Thickness T 2 (mm) Permeability ap [l (s m 2 ) 1 Pa) 1 ] Fit index 1 A Jacket B C D E F G H I J K L M Jacket N Shirt O Uniform P Jacket_ Q Shirt R Jacket_ C+S Jacket M+S Jacket N+S Shirt O+S Uniform G+S Jacket K+S Jacket P+S Jacket_ Q+S Shirt R+S Jacket_ U+S Jacket_ V+S Jacket_ U+S+T+N Jacket_ V+S+T+N Jacket_ W+S Jacket_ Note: CL_ID represents a clothing ensemble label denoting which clothing ensemble was clothed on manikin. wind velocity for three clothing ensembles. It can be seen that there is a general trend that clothing thermal insulation or moisture vapour resistance decreases with the increase in wind velocity, but the rate of reduction decreases with the increase in wind velocity. The reduction ratios, F I and F R, for thermal insulation and for moisture vapour resistance can be expressed as: I st ¼ ð1 þ F I ÞI t ð5þ F I ¼ I st I t I t ð6þ R st ¼ ð1 þ F R ÞR t ð7þ F R ¼ R st R t R t ; ð8þ where, I st and I t are the total thermal insulation (m 2 CW 1 ) of garment in the case of body standing in still air and under any situations, respectively. R st and R t are the total moisture vapour resistance (m 2 Pa W 1 ) of garment in the case of body standing in still air and under any situations, respectively. The reduction ratios, F I and F R, are related to the wind velocity; they are plotted against the wind velocity for three clothing ensembles in Fig. 3a and b as examples. As can been seen, the reduction ratios, F I and F R, have approximately linear relations with the wind velocity. The slopes of F I and F R versus the wind velocity may vary with different types of clothing ensembles. Figure 4a and b plot the F I and F R versus the wind for all clothing ensembles tested in the present study. As can been seen, the approximate linear relationship between F I and F R and the wind velocity holds for all
5 Prediction of clothing thermal insulation 837 clothing ensembles tested and the slopes vary within certain ranges. Therefore, we can assume: F I ¼ K I ðv wind v 0 Þ ð9þ F R ¼ K R ðv wind v 0 Þ ð10þ where, K I and K R are the slopes of Fig. 4a and b, respectively; v 0 is the air current in the chamber under still air condition, i.e. the condition under which I st and R st are measured, in this study, v 0 = 0.22 m s 1 (In any climate chamber, even at still air condition, there is air current. This is essential for the operation of air conditioning system in the chamber). K I and K R can be obtained by linear regression for each clothing ensemble. The values are listed in Supplementary Table 4 in the on-line Supplementary Material. Fig. 1. Walter in walking motion. Effect of walking speed Figure 5a and b plot the clothing thermal insulation and moisture vapour resistance against walking speed for three clothing ensembles under two windy conditions. As can be seen, the clothing thermal (a) (b) Fig. 2. (a) Clothing thermal insulation versus wind velocity. (b) Clothing moisture vapour resistance versus wind velocity.
6 838 X. Qian and J. Fan (a) (b) Fig. 3. (a) F I versus wind velocity for three clothing ensembles and (b) F R versus wind velocity for three clothing ensembles. (a) (b) Fig. 4. (a) F I versus wind velocity for all clothing ensembles (the lines show the range of the variation of F I ) and (b) F R versus wind velocity for all clothing ensembles (the lines show the range of the variation of F R ).
7 Prediction of clothing thermal insulation 839 (a) (b) Fig. 5. (a) Total thermal insulation versus walking speed for three clothing ensembles and (b) total moisture vapour resistance versus walking speed for three clothing ensembles. insulation and moisture vapour resistance decrease with increasing walking speed, and the ratio of reduction decreases with increasing walking speed and wind velocity. This is similar to the effect of wind velocity on clothing thermal insulation and moisture vapour resistance. Therefore, we can use an equivalent wind velocity to take into account the effect of walking speed. By analogy with the definition of effective wind velocity v eff for the surface thermal insulation and surface moisture vapour resistance (Lotens and Havenith, 1991; Qian and Fan, 2005), let us define: v F ¼ V wind þ b F V walk ð11þ where, b F is an equivalent factor of walking speed. Using the values of K I and K R listed in Supplementary Table 3 in the on-line Supplementary Material, b F can be obtained by fitting equations (9) and (10), using v F from equation (11) instead of the wind velocity. b F ¼ 1:8 ð12þ with a correlation coefficient of fit (R 2 ) of This means the effect of walking speed on the thermal insulation and moisture vapour resistance is stronger than the effect of wind velocity. The new regression model Substituting equations (6) and (8) with equations (9) (12) and rewritten as below: I t I st ¼ R t R st ¼ 1 1 þ K I ðv wind þ 1:8V walk v 0 Þ 1 1 þ K R ðv wind þ 1:8V walk v 0 Þ ð13þ ð14þ When the body is walking in wind, according to the equations (13) and (14), the K I and K R for each clothing ensembles can be calculated by fitting the data; K I and K R are listed in Supplementary Table 4 in the on-line Supplementary Material in the on-line edition of this issue.
8 840 X. Qian and J. Fan In Supplementary Table 4 in the on-line Supplementary Material, it can be seen that K I may vary from 0.24 to 0.31, and K R may vary from 0.23 to 0.42, depending on the clothing characteristics such as fabric air permeability, garment style, garment fitting and clothing construction. Using the average values of K I and K R, we have: I t I st ¼ 1 1 þ 0:27ðV wind þ 1:8V walk v 0 Þ ð15þ (a) R t R st ¼ 1 1 þ 0:32ðV wind þ 1:8V walk v 0 Þ ð16þ With equations (15) and (16), the clothing thermal insulation and moisture vapour resistance under windy conditions and walking motion can be predicted from those measured when the manikin is standing in still air condition. Figure 6a and b plot the predicted clothing thermal insulation and moisture vapour resistance against the measured values. As can been seen, the model can fit the measured data very well with a correlation coefficient of fit (R 2 ) of (b) VALIDATION OF THE MODELS The models are based on the experimental data of 32 sets of clothing ensembles, including tight and loose fit garments, jackets, shirts and uniforms with permeable and impermeable outer fabrics. These clothing assembles were tested on the walking-able sweating manikin Walter in a climate chamber under 20 C and 50% RH, with the wind velocity and walking speed varying from 0.22 to 4.04 m s 1 and 0 to 0.69 m s 1, respectively. The static total thermal insulation and moisture vapour resistance of the clothing ensembles ranged clo ( m 2 C W 1 ) and m 2 Pa W 1, respectively. Although this has been a systematic experimental investigation, the models developed based on these limited experimental data were validated with experimental data from other sources. The database used to validate the models includes those reported in the published literatures. Some of these data were obtained from manikins (Hong, 1992; Holmer et al., 1996; Bouskill et al., 2002; Adair, 2005) and some were from measurements on human subjects (Nielsen et al., 1985; Lotens and Havenith, 1988; Havenith 1990a,b). Figure 7 plots the measured dynamic thermal insulation against the values predicted using the new direct regression model developed in the present study with all database. As can be seen, the new direct regression model predicts the measured thermal insulation from both our experiments on the sweating manikin, Walter, and those reported in the literature quite well. There is however some Fig. 6. (a) Measured thermal insulation versus predicted values using the new model and (b) measured moisture vapour resistance versus predicted values using the new model. underestimation for clothing ensembles with high thermal insulation, particularly for the two winter ensembles tested by Holmer et al. and one winter ensemble tested by Bouskill et al. (2002). This may be due to the fact that, in the experimental data used for establishing the new direct regression model, there is no winter clothing ensemble as warm as those two tested by Holmer et al. and that tested by Bouskill et al. (2002). Figure 8 plots the measured clothing moisture vapour resistance against the values predicted using the new direct regression model. With the exception for the data of the impermeable rain coverall tested by Havenith et al. on human subjects using the tracer gas method, the new direct regression model provides very good prediction. The squared correlation coefficient of the new direct regression model would be 0.91, if the data of the impermeable rain coverall tested by Havenith et al. on human subjects using the trace gas method was omitted in the analysis.
9 Prediction of clothing thermal insulation 841 Fig. 7. Measured thermal insulation with all data versus the values predicted using the new direct regression model. Fig. 8. Measured clothing moisture vapour resistance with all data versus the values predicted using the new direct regression model. CONCLUSIONS From the experimental investigation, it was shown that clothing thermal insulation and moisture vapour resistance decrease with increasing wind velocity and walking speed. The effects of walking speed for the total thermal insulation and moisture vapour resistance of clothing system are equivalent to 180% of the wind velocity. Based on an improved understanding of the effects of wind and walking motion on the clothing thermal insulation and moisture vapour resistance, a simple, but effective regression model was developed for predicting the dynamic clothing thermal insulation and moisture vapour resistance under walking motion and windy conditions from the values of the clothing thermal insulation and moisture vapour resistance measured under person standing in the still air. For the prediction parameters, K I and K R, it was found that different clothing ensembles have different values of K I and K R, and they are significantly affected by the air permeability of the outer fabric, fit index and garment style as well as whether or not there is underwear on the body. Generally, the average values of K I and K R can be selected to predict I t and R t.
10 842 X. Qian and J. Fan Acknowledgements The authors wish to thank the University Grant Council of Hong Kong SAR for funding the project through a CERG grant no. PolyU5148/01E. APPENDIX Variables b F = an equivalent factor of walking speed for the total clothing thermal insulation and moisture vapour resistance. l=evaporative heat of water at the skin temperature, l=0.67 W h g 1 (35 o C). A p = the air permeability [l (m 2 s) 1 ] of clothing fabrics. A s = the body (manikin) surface area in m 2. F I = the reduction ratio for the total thermal insulation of clothing ensembles [defined by equation (8)]. F it = the garment fit index. F R = the reduction ratio for the total moisture vapour resistance of clothing ensembles under an equivalent wind velocity related to standing in still air situation. H a = the energy required to heat the water supplement to manikin s body temperature in W. H d = the dry heat loss from the manikin in W. H e = the evaporative heat loss from skin to the environment in W. H p = the heat generated from the pump in W. H s = the heat generated from the heating elements in the manikin in W. I st = the total thermal insulation of garment in the case of body standing in still air (m 2 CW 1 ). I t = the total thermal insulation (m 2o CW 1 ) of clothing ensembles under any situation. K I = the slopes of the curve of F I versus the wind velocity. K R = the slopes of the curve of F R versus the wind velocity. p sa = the saturated moisture vapour pressure at environment temperature in Pa. p ss = the saturated moisture vapour pressure at the skin temperature in Pa. Q = the water loss (or perspiration rate) from the manikin (g h 1 ). R es = the moisture vapour resistance of the manikin skin (8.6 Pa m 2 W 1 ). RH a = the relative humidity of the environment in %. R st = the total moisture vapour resistance of garment in the case of body standing in still air (Pa m 2 W 1 ). R t = the total moisture vapour resistance (Pa m 2 W 1 ) of clothing ensembles under any situation (Pa m 2 W 1 ). T a = the environmental temperature in C. T s = the area weighted mean skin temperature in C. v 0 = the air current in the still air condition. In this study, v 0 = 0.22 m s 1. v F = an equivalent wind velocity (m s 1 ). V walk = walking speed (m s 1 ). V wind = wind velocity (m s 1 ). REFERENCES Adair ER. (2005) RF protective garments as a countermeasure to field strengths in excess of IEEE C Standard, _thermal_evaluation.pdf. ASTM Book of Standards. (2004) Textiles (I). Vol , November pp. D Bouskill LM, Havenith G, Kuklane K et al. (2002) Relationship between clothing ventilation and thermal insulation. AIHA J; 63: Fan J, Chen YS. (2002) Measurement of clothing thermal insulation and moisture vapor resistance using a novel perspiring fabric thermal manikin. Meas Sci Technol; 13: Fan JT, Qian XM. (2004) New functions and applications of Walter, thesweatingfabricmanikin. Eur J Appl Physiol; 92: Holmer I, Nilsson G, Havenith I et al. (1999) Clothing convective heat exchange. Ann Occup Hyg; 43: Holmer I, Nilsson H, Meinander H, (1996) Evaluation of clothing heat transfer by dry and sweating manikin measurements. In Johnson JS and Mansdorf SZ, editors. Performance of protective clothing. 5th Vol. West Conshohoken, PA: American Society for Testing and Materials, STP Hong S. (1992) A database for determining the effect of walking on clothing insulation. Doctoral dissertation, Department of Clothing, Textiles, and Interior Design, College of Human Ecology, Kansas State University, Manhattan. ISO (1995) Ergonomics of the thermal environment estimation of the thermal insulation and evaporative resistance of a clothing ensemble. ISO Geneva: International Organization for Standardisation. Lotens WA, Havenith G. (1988) Ventilation of rainwear determined by a trace gas method. In Environmental ergonomics. London: Taylor & Francis. pp Lotens WA, Havenith G. (1991) Calculation of clothing insulation and vapor resistance. Ergonomics; 34: Nielsen R, Olesen BW, Fanger PO. (1985) Effect of physical activity and air velocity on the thermal insulation of clothing. Ergonomics; 28: Nilsson HO, Anttonen H, Holmer I. (2000) Method for cold protective clothing evaluation. Ergonomics of protective clothing. In Proceedings of Nokobetef 6and 1st European conference on protective clothing, May 7 10, 2002, Stockholm, Sweden. Qian X, Fan J. (2005) Surface thermal insulation and moisture vapour resistance of human body under varying environmental conditions and walking speeds. In 11th International Conference on Environmental Ergonomics, ICEE2005, May 22 26, 2005, Ystad, Sweden. SiroFAST. (1989) Fabric assurance by simple testing. CSIRO instruction manual. Sydney, Australia: Division of Wool Technology. Spencer-smith JL. (1977a) The physical basis of clothing comfort, Part 2. Cloth Res J; 5: Spencer-smith JL. (1977b) The physical basis of clothing comfort, Part 3. Cloth Res J; 5:
A Comparative Introduction on Sweating Thermal Manikin Newton and Walter
A Comparative Introduction on Sweating Thermal Manikin Newton and Walter Wang, Faming Published: 2008-01-01 Link to publication Citation for published version (APA): Wang, F. (2008). A Comparative Introduction
More informationThe comparison of thermal properties of protective clothing using dry and sweating manikins
The comparison of thermal properties of protective clothing using dry and sweating manikins Gao, Chuansi; Holmér, Ingvar; Fan, Jintu; Wan, Xianfu; Wu, John YS; Havenith, George Published in: [Host publication
More informationThe interaction of clothing. ventilation with dry and evaporative heat transfer of jackets: the effect of air and. vapor permeability
Loughborough University Institutional Repository The interaction of clothing ventilation with dry and evaporative heat transfer of jackets: the effect of air and vapor permeability This item was submitted
More informationDevelopment of Empirical Equations to Predict Sweating Skin Surface Temperature for Thermal Manikins in Warm Environments.
Development of Empirical Equations to Predict Sweating Skin Surface Temperature for Thermal Manikins in Warm Environments. Wang, Faming; Kuklane, Kalev; Gao, Chuansi; Holmér, Ingvar Published: 2010-01-01
More informationClothing insulation From Wikipedia, the free encyclopedia
Page 1 of 9 Clothing insulation From Wikipedia, the free encyclopedia Clothing insulation is the thermal insulation provided by clothing. [1][2] Even if the main role of clothing is to protect from the
More informationSimulation of perspiration in sweating fabric manikin-walter
Design and Nature III: Comparing Design in Nature with Science and Engineering 221 Simulation of perspiration in sweating fabric manikin-walter J. Fan Institute of Textiles and Clothing, The Hong Kong
More informationThe E ects of Wind and Human Movement on the Heat and Vapour Transfer Properties of Clothing
PII: S0003-4878(99)00061-7 Ann. occup. Hyg., Vol. 43, No. 5, pp. 347±352, 1999 # 1999 British Occupational Hygiene Society Published by Elsevier Science Ltd. All rights reserved Printed in Great Britain.
More informationContact person:
APPARENT TOTAL EVAPORTAIVE RESISTANCE AND CLOTHING ADJUSTMENT FACTORS AT DIFFERENT HUMIDITIES AND METABOLIC RATES Thomas E. Bernard 1, Victor Caravello 1, Elizabeth A. McCullough 2, Candi D. Ashley 1 1
More informationDefense Technical Information Center Compilation Part Notice
UNCLASSIFIED Defense Technical Information Center Compilation Part Notice ADP012413 TITLE: Prediction of Wind Effects on Cold Protective Clothing DISTRIBUTION: Approved for public release, distribution
More informationInteraction effects of radiation and convection measured by a thermal manikin wearing protective clothing with different radiant properties
Loughborough University Institutional Repository Interaction effects of radiation and convection measured by a thermal manikin wearing protective clothing with different radiant properties This item was
More informationHealthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland
Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland Paper ID 0113 ISBN: 978-83-7947-232-1 Measurements of local clothing resistances and local area factors under various conditions Stephanie Veselá
More informationHeat Balance When Wearing Protective Clothing
PII: S0003-4878(99)00051-4 Ann. occup. Hyg., Vol. 43, No. 5, pp. 289±296, 1999 # 1999 British Occupational Hygiene Society Published by Elsevier Science Ltd. All rights reserved Printed in Great Britain.
More informationA Comparison of Two Methods of Determining Thermal Properties of Footwear
INTERNATIONAL JOURNAL OF OCCUPATIONAL SAFETY AND ERGONOMICS 1999, VOL. 5, NO. 4, 477-484 A Comparison of Two Methods of Determining Thermal Properties of Footwear Kalev Kuklane Department of Occupational
More informationFORCED VENTILATION OF PROTECTIVE GARMENTS FOR HOT INDUSTRIES. J.A. Gonzalez, L.G. Berglund, T.L. Endrusick*, M.A. Kolka
Abstract FORCED VENTILATION OF PROTECTIVE GARMENTS FOR HOT INDUSTRIES J.A. Gonzalez, L.G. Berglund, T.L. Endrusick*, M.A. Kolka Biophysics and Biomedical Modeling Division U.S. Army Research Institute
More informationPublished in: Proceedings of the 11th International Conference on Environmental Ergonomics
Using 3D whole body scanning to determine clothing area factor Gao, Chuansi; Kuklane, Kalev; Holmér, Ingvar Published in: Proceedings of the 11th International Conference on Environmental Ergonomics 2005
More informationExperimental Heated, Breathing and Sweating Manikins. Integrating radiant. Fatigue Lab constructs the. losses. military use. of human body heat
Assessment of the Thermal Environment Experimental Heated, Breathing and Sweating Manikins George Havenith Professor of Environmental Physiology and Ergonomics Environmental Ergonomics Research Centre
More informationParallel and Serial Methods of Calculating Thermal Insulation in European Manikin Standards
International Journal of Occupational Safety and Ergonomics (JOSE) 2012, Vol. 18, No. 2, 171 179 Parallel and Serial Methods of Calculating Thermal Insulation in European Manikin Standards Kalev Kuklane
More informationComfort of Clothing. Rajesh Mishra & Jiri Militky Technical University of Liberec Liberec, Czech Republic
Comfort of Clothing Rajesh Mishra & Jiri Militky Technical University of Liberec Liberec, Czech Republic Comfort Physical comfort - Mechanical Physiological comfort - Transmission Psychological comfort
More informationSCRUB SUITS VS CLEAN AIR SUITS A THERMAL PROPERTIES COMPARISON
SCRUB SUITS VS CLEAN AIR SUITS A THERMAL PROPERTIES COMPARISON Isabel ABREU; Patrícia RIBEIRO & Maria José ABREU Abstract: In operationg room (OR), the health professionals are exposed to stress situations
More informationMeasurement Method for the Solar Absorptance of a Standing Clothed Human Body
Original Article Journal of the Human-Environment System Vol.19; No 2; 49-55, 2017 Measurement Method for the Solar Absorptance of a Standing Clothed Human Body Shinichi Watanabe 1) and Jin Ishii 2) 1)
More informationProfessor Alan Hedge, Cornell University 1/22
1 2 3 4 5 6 7 8 9 Thermal Comfort DEA 3500 - Human Factors: Ambient Environment Thermal comfort scales Thermal comfort and thermal sensation are not the same Thermal sensation depends on skin temperature
More informationResearch Article Artificial Neural Network Estimation of Thermal Insulation Value of Children s School Wear in Kuwait Classroom
Artificial Neural Systems Volume 25, Article ID 4225, 9 pages http://dx.doi.org/.55/25/4225 Research Article Artificial Neural Network Estimation of Thermal Insulation Value of Children s School Wear in
More informationHealthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Local air gap thickness model for realistic simulation of thermal effects in clothing
Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland Paper ID 0238 ISBN: 978-83-7947-232-1 Local air gap thickness model for realistic simulation of thermal effects in clothing Agnes Psikuta*,
More informationPerformance Study of Protective Clothing against Hot Water Splashes: from Bench Scale Test to Instrumented Manikin Test
Ann. Occup. Hyg., 2015, Vol. 59, No. 2, 232 242 doi:10.1093/annhyg/meu087 Advance Access publication 27 October 2014 Performance Study of Protective Clothing against Hot Water Splashes: from Bench Scale
More informationThe effects of protective clothing on metabolic rate
Loughborough University Institutional Repository The effects of protective clothing on metabolic rate This item was submitted to Loughborough University's Institutional Repository by the/an author. Citation:
More informationSBS5225 HVACR I Thermal Comfort. Ir. Dr. Sam C. M. Hui Faculty of Science and Technology
SBS5225 HVACR I http://ibse.hk/sbs5225/ Thermal Comfort Ir. Dr. Sam C. M. Hui Faculty of Science and Technology E-mail: cmhui@vtc.edu.hk Aug 2016 Contents What is Thermal Comfort? Thermal Environment and
More informationThe Role of Tests and Manikin in Defining Fabrics Thermal Characteristics
Ghada Ahmad Mohamad Assistant Professor, Spinning, Weaving, and Knitting Department, Faculty of Applied Arts, Helwan University, Egypt. Abstract: Testing plays an important role in maintaining the competitiveness
More informationRoom Climate Standard. Thomas Wolf, CSES
Thomas Wolf, CSES The Challenge TW, CSE 2/ 19 The Motivation Energy vs. room climate conditions 1 C = 1 kj/kg 1 g/kg = 2.5 kj/kg TW, CSE 3/ 19 The Definition Thermal Comfort: That condition of mind which
More informationTesting Services for the Evaluation of. Fabric Systems, Clothing Systems, Sleeping Bag Systems, Bedding Systems, and Personal Cooling Systems (PCS)
Testing Services for the Evaluation of Fabric Systems, Clothing Systems, Sleeping Bag Systems, Bedding Systems, and Personal Cooling Systems (PCS) Kansas State University Meredith Schlabach Testing Coordinator
More informationTHE COMFORT, MEASURED BY MEANS OF A SWEATING MANIKIN (WALTER TM ), OF CLOTHING CONTAINING DIFFERENT FIBRE COMBINA- TIONS: A PRELIMINARY INVESTIGATION
THE COMFORT, MEASURED BY MEANS OF A SWEATING MANIKIN (WALTER TM ), OF CLOTHING CONTAINING DIFFERENT FIBRE COMBINA- TIONS: A PRELIMINARY INVESTIGATION Anton F Botha*, Marguerite E Stoffberg & Lawrance Hunter
More informationTesting Cold Protection According to EN ISO 20344: Is There Any Professional Footwear that Does Not Pass?
Ann. Occup. Hyg., Vol. 53, No. 1, pp. 63 68, 2009 Ó The Author 2008. Published by Oxford University Press on behalf of the British Occupational Hygiene Society doi:10.1093/annhyg/men074 Testing Cold Protection
More informationINVESTIGATION OF HEAD COVERING AND THERMAL COMFORT IN RADIANT COOLING MALAYSIAN OFFICES
INVESTIGATION OF HEAD COVERING AND THERMAL COMFORT IN RADIANT COOLING MALAYSIAN OFFICES Neama, S.* Department of Architecture, Faculty of Design and Architecture, Universiti Putra Malaysia, 43400 UPM Serdang,
More information* Nara Women's University, Nara, Japan Nofer Institute of Occupational Medicine, Lo&, Poland
THERMOREGULATORY AND CIRCULATORY REACTIONS IN SUBJECTS EXPOSED TO THE SUN AND WEARING WHITE AND BLACK CLOTHING K. Blazejczyk', H. Tokuraz, A. Bortkiewic2, M. Katoz and W. Szymczak3 Institute of Geography
More informationNon-evaporative effects of a wet mid layer on heat transfer through protective clothing
Loughborough University Institutional Repository Non-evaporative effects of a wet mid layer on heat transfer through protective clothing This item was submitted to Loughborough University's Institutional
More informationPrediction of WBGT-based clothing adjustment values from evaporative resistance
Original Article PREDICATION Industrial Health OF 2017, WBGT 55, CAVS 549 554 549 Prediction of WBGT-based clothing adjustment values from evaporative resistance Thomas E. BERNARD 1 *, Candi D. ASHLEY
More informationDetermination of the Air Gap Thickness underneath the Garment for Lower Body Using 3D Body Scanning
Determination of the Air Gap Thickness underneath the Garment for Lower Body Using 3D Body Scanning Emel MERT 1,2, Sonja BÖHNISCH 1,3, Agnes PSIKUTA* 1, Marie-Ange BUENO 2, Rene M. ROSSI 1 1 Empa, Swiss
More informationSchool of Health Sciences, University of Wollongong, Wollongong, Australia. Contact person:
AN EVALUATION OF THE THERMAL PROTECTIVE CLOTHING USED BY SIX AUSTRALIAN FIRE BRIGADES. Pete Kerry, Anne M.J. van den Heuvel, Martin van Dijk, Gregory E. Peoples and Nigel A.S. Taylor School of Health Sciences,
More informationThermal comfort sustained by cold protective clothing in Arctic open-pit mining a thermal manikin and questionnaire study
Original Article THERMAL Industrial Health COMFORT 2017, 55, AND 537 548 PROTECTION IN ARCTIC MINING 537 Thermal comfort sustained by cold protective clothing in Arctic open-pit mining a thermal manikin
More informationCLOTHING REAL EVAPORATIVE RESISTANCE DETERMINED BY MEANS OF A SWEATING THERMAL MANIKIN: A NEW ROUND-ROBIN STUDY
CLOTHING REAL EVAPORATIVE RESISTANCE DETERMINED BY MEANS OF A SWEATING THERMAL MANIKIN: A NEW ROUND-ROBIN STUDY Wang, Faming; Havenith, George; Mayor, Tiago Sotto; Kuklane, Kalev; Leonard, Jean; Zwolinska,
More informationImpact of local clothing values on local skin temperature simulation
Proceedings of 9 th Windsor Conference: Making Comfort Relevant Cumberland Lodge, Windsor, UK, 7-10 April 2016. Network for Comfort and Energy Use in Buildings, http://nceub.org.uk Impact of local clothing
More informationImproving Men s Underwear Design by 3D Body Scanning Technology
Abstract Improving Men s Underwear Design by 3D Body Scanning Technology V. E. KUZMICHEV* 1,2,3, Zhe CHENG* 2 1 Textile Institute, Ivanovo State Polytechnic University, Ivanovo, Russian Federation; 2 Institute
More informationAssessment of Hypothermia Blankets Using an Advanced Thermal Manikin John P. Rugh 1* and Khalid Barazanji 2
Assessment of Hypothermia Blankets Using an Advanced Thermal Manikin John P. Rugh 1* and Khalid Barazanji 2 1 U.S. Department of Energy National Renewable Energy Laboratory, Golden, Colorado, USA 2 U.S.
More informationIdentifying a suitable method for studying thermal comfort in people s homes
Identifying a suitable method for studying thermal comfort in people s homes Vireen Limbachiya 1, 2, Keyur Vadodaria 1, Dennis Loveday 1, Victoria Haines 3 1 School of Civil and Building Engineering, Loughborough
More informationComparison of Women s Sizes from SizeUSA and ASTM D Sizing Standard with Focus on the Potential for Mass Customization
Comparison of Women s Sizes from SizeUSA and ASTM D5585-11 Sizing Standard with Focus on the Potential for Mass Customization Siming Guo Ph.D. Program in Textile Technology Management College of Textiles
More informationAn evaluation of the thermal protective clothing used by six Australian fire brigades
University of Wollongong Research Online Faculty of Health and Behavioural Sciences - Papers (Archive) Faculty of Science, Medicine and Health 2009 An evaluation of the thermal protective clothing used
More informationThe Use of 3D Anthropometric Data for Morphotype Analysis to Improve Fit and Grading Techniques The Results
The Use of 3D Anthropometric Data for Morphotype Analysis to Improve Fit and Grading Techniques The Results Abstract Joris COOLS 1*, Alexandra DE RAEVE 1, Peter VAN RANSBEECK 2, Simona VASILE 1, Benjamin
More informationComparisons of Thermal and Evaporative Resistances of Kapok Coats and Traditional Down Coats
Comparisons of Thermal and Evaporative esistances of Kapok Coats and Traditional Down Coats Wang, Faming Published in: Fibres & Textiles in Eastern Europe Published: 2010-01-01 Link to publication Citation
More informationClothing insulation as a behavioural adaptation for thermal comfort in Indian office buildings
Proceedings of 9 th Windsor Conference: Making Comfort Relevant Cumberland Lodge, Windsor, UK, 7-10 April 2016. Network for Comfort and Energy Use in Buildings, http://nceub.org.uk Clothing insulation
More informationLaboratory assessment of cold weather clothing
Loughborough University Institutional Repository Laboratory assessment of cold weather clothing This item was submitted to Loughborough University's Institutional Repository by the/an author. Citation:
More informationEvaluation of the performance of elastic band used for ready made garment manufacturing
Alexandria Engineering Journal (2011) 50, 291 295 Alexandria University Alexandria Engineering Journal www.elsevier.com/locate/aej www.sciencedirect.com ORIGINAL ARTICLE Evaluation of the performance of
More informationApplicability of the Thermal Manikin for Thermal Comfort Investigations
Szent István University Applicability of the Thermal Manikin for Thermal Comfort Investigations Thesis of PhD Work Zoltán Magyar Gödöllő, Hungary 2011 Doctoral School Denomination: Mechanical Engineering
More informationCalculation of Clothing Insulation by Serial and Parallel Methods: Effects on Clothing Choice by IREQ and Thermal Responses in the Cold
International Journal of Occupational Safety and Ergonomics (JOSE) 2007, Vol. 13, No. 2, 103 116 Calculation of Clothing Insulation by Serial and Parallel Methods: Effects on Clothing Choice by IREQ and
More informationCHAPTER 6 DESIGN AND DEVELOPMENT OF HOSPITAL BED LINEN
186 CHAPTER 6 DESGN AND DEVELOPMENT OF HOSPTAL BED LNEN 6.1 NTRODUCTON The bed sheets used in hospitals are made of cotton or polyester cotton blended fabrics, which seems to date from the past centuries.
More informationInvestigation into Fit, Distribution and Size of Air Gaps in Fire-Fighter Jackets to Female Body Form
Investigation into Fit, Distribution and Size of Air Gaps in Fire-Fighter Jackets to Female Body Form Nazia NAWAZ, Olga TROYNIKOV*, Kate KENNEDY School of Fashion and Textiles, RMIT University, Melbourne,
More informationSnowplant Collection Workbook
Snowplant Collection Workbook Edition 170201 SKI SCHOOL, CLUB AND UNIFORM CLOTHING 2 SNOWPLANT COLLECTION DEVELOPED FOR PROFESSIONAL USE Quality Extraordinary durability for everyday use Top performance
More informationSupporting Material for TIA 1105 (2112)
Supporting Material for TIA 1105 (2112) This study was carried out by a task group under the direction of the technical committee to investigate and the safety of various cold weather insulation materials
More informationUC Berkeley Indoor Environmental Quality (IEQ)
UC Berkeley Indoor Environmental Quality (IEQ) Title Thermal adaptation and insulation opportunities provided by different drapes of Indian saris Permalink https://escholarship.org/uc/item/8f10n38d Journal,
More informationCHAPTER 4 INFLUENCE OF LYOCELL FIBER BLENDS ON THE COMFORT CHARACTREISTICS OF HOSPITAL TEXTILES
83 CHAPTER 4 INFLUENCE OF LYOCELL FIBER BLENDS ON THE COMFORT CHARACTREISTICS OF HOSPITAL TEXTILES This chapter deals with the production of blended yarns, analysis of the yarn characteristics, selection
More informationThe Use of Footwear Insulation Values Measured on a Thermal Foot Model
International Journal of Occupational Safety THE USE andof Ergonomics FOOTWEAR (JOSE) INSULATION 2004, Vol. IN10, PRACTICE No. 1, 79 86 The Use of Footwear Insulation Values Measured on a Thermal Foot
More informationSkin Temperature and Predicted Discomfort of Women Wearing Sheer Empire Style Dress
Fibers and Polymers 2016, Vol.17, No.6, 963-970 DOI 10.1007/s12221-016-5911-3 ISSN 1229-9197 (print version) ISSN 1875-0052 (electronic version) Skin Temperature and Predicted Discomfort of Women Wearing
More informationEffect of Hair Style on Human Physiological Responses in a Hot Environment
Effect of Hair Style on Human Physiological Responses in a Hot Environment Myung-Ju Kim 1, Jeong-Wha Choi 1,2,, Hyung-Kook Lee 3 1 Seoul National University, Seoul, Korea 2 Institute of Human Ecology,
More informationEffects of Two Cooling Garments on Post-exercise Thermal Comfort of Female Subjects in the Heat
Fibers and Polymers 2015, Vol.16, No.6, 1403-1409 DOI 10.1007/s12221-015-1403-0 ISSN 1229-9197 (print version) ISSN 1875-0052 (electronic version) Effects of Two Cooling Garments on Post-exercise Thermal
More informationHeat stress in chemical protective clothing: porosity and vapour resistance
Jan 19 2011 Final version Heat stress in chemical protective clothing: porosity and vapour resistance George Havenith 1, Emiel den Hartog 2 and Svein Martini 3 1) Environmental Ergonomics Research Centre,
More informationA Novel Approach for Fit Analysis of Protective Clothing Using Three-Dimensional Body Scanning
A Novel Approach for Fit Analysis of Protective Clothing Using Three-Dimensional Body Scanning Yehu LU a,b, Guowen SONG c *, Jun LI a,b a Protective Clothing Research Center, Fashion Institute, Donghua
More informationTECHNICAL NOTE NO. TN16-1 DATE January 2016 ADA DEVELOPMENT OF MATLAB SCRIPTS FOR THE CALCULATION OF THERMAL MANIKIN REGIONAL RESISTANCE VALUES
TECHNICAL NOTE NO. TN16-1 DATE January 2016 ADA DEVELOPMENT OF MATLAB SCRIPTS FOR THE CALCULATION OF THERMAL MANIKIN REGIONAL RESISTANCE VALUES DISCLAIMER The opinions or assertions contained herein are
More informationInfluence of Undergarment Structure on the Parameters of the Microclimate under Hermetic Protective Clothing
Grażyna Bartkowiak Central Institute for Labour Protection - National Research Institute, Department of Personal Protective Equipment ul. Wierzbowa 48, 90-133 Lódź, Poland e-mail: grbar@ciop.lodz.pl Influence
More informationSHIRTS / JACKETS / VEST SHORTS / TIGHTS THE FUNCTIONS: S M L XL XXL 3XL. S M L XL XXL 3XL Lycra fabric Wrinkle recovery S M L XL XXL
SHIRTS / JCKETS / VEST 32-37 SHORTS / TIGHTS 28-31 THE FUNCTIONS: Breathable Stretch Shape retention Lycra fabric Wrinkle recovery Flexibility Breathable Heat exchange CoolDry Fast drying Microstructure
More informationBiomedical Research 2018; Special Issue: ISSN X Study on the effect of professional sports clothing on sports physiology.
Biomedical Research 2018; Special Issue: ISSN 0970-938X www.biomedres.info Study on the effect of professional sports clothing on sports physiology. Zhiwei Li 1*, Yong Wang 2 1 Department of Physical Education,
More informationSTUDY OF MANUFACTURING THERMOCHROMIC WOOD. Zhijia Liu. Fucheng Bao* Feng Fu*
STUDY OF MANUFACTURING THERMOCHROMIC WOOD Zhijia Liu PhD Student Fucheng Bao* Professor Feng Fu* Professor Research Institute of Wood Industry Chinese Academy of Forestry Xiangshan Road, Beijing, China,
More informationPerformance of Protective Clothing: Global Needs and Emerging Markets: 8 th Symposium
STP 1462 Performance of Protective Clothing: Global Needs and Emerging Markets: 8 th Symposium Portia Yarborough and Cherilyn N. Nelson, Editors ASTM Stock Number: STP1462 @ ASTM International 100 Barr
More informationCLI MATE PROTECTION SYSTE M S
CLI MATE PROTECTION SYSTE M S CLOTHING SYSTEMS ENGINEERED ACCORDING TO PEOPLE S INNATE CHARACTERISTICS AND CLIMATIC FACTORS OUR JOB IS MAKING SURE YOU CAN DO YOURS When Taiga was founded in 1982, the company
More informationHeat Gain From Thermal Radiation Through Protective Clothing With Different Insulation, Reflectivity and Vapour Permeability
International Journal of Occupational Safety and Ergonomics (JOSE) 2010, Vol. 16, No. 2, 231 244 Heat Gain From Thermal Radiation Through Protective Clothing With Different Insulation, Reflectivity and
More information8/2016. Protective clothing for firefighters TIGER MATRIX. 3rd category of Personal Protective Clothing
8/2016 Protective clothing for firefighters TIGER MATRIX 3rd category of Personal Protective Clothing 1 2 3 Used materials and their technical parameters: Construction No. 1: Outer shell material: Fabric
More informationChapman Ranch Lint Cleaner Brush Evaluation Summary of Fiber Quality Data "Dirty" Module 28 September 2005 Ginning Date
Chapman Ranch Lint Cleaner Evaluation Summary of Fiber Quality Data "Dirty" Module 28 September 25 Ginning Date The following information records the results of a preliminary evaluation of a wire brush
More informationINTRODUCING NOMEX LIMITEDWEAR
INTRODUCING NOMEX LIMITEDWEAR PERFORM WHEN THE HEAT S ON The safety and security of NOMEX in low-cost, limited-use FR garments TOTAL PREDICTED BODY BURN (%) 100 80 60 40 20 THERMAL MANIKIN TEST RESULTS
More informationImprovement in Wear Characteristics of Electric Hair Clipper Blade Using High Hardness Material
Materials Transactions, Vol. 48, No. 5 (2007) pp. 1131 to 1136 #2007 The Japan Institute of Metals EXPRESS REGULAR ARTICLE Improvement in Wear Characteristics of Electric Hair Clipper Blade Using High
More informationEVALUATION OF PHYSIOLOGICAL PROPERTIES OF THE FIRST LAYER GARMENT FOR SPORT APPAREL
EVALUATION OF PHYSIOLOGICAL PROPERTIES OF THE FIRST LAYER GARMENT FOR SPORT APPAREL Antonín Havelka 1, Ladislav Nagy 1 1 Technical University of Liberec, Faculty of Textile Engineering, Department of Clothing
More informationALU-SAFE HAS BEEN TESTED AGAINST THE FOLLOWING STANDARDS: Full technical details and further information can be found at
ALU-SAFE HAS BEEN TESTED AGAINST THE FOLLOWING STANDARDS: O MOLTEN ALUMINIUM PER ISO 9185: 2007 AT 960 C (853,664,676) MOLTEN CRYOLITE PER ISO 9185;2007 AT 1120 C (664,676) IPAI TEST METHOD, PROCEDURE
More informationMILITARY TEXTILE MATERIALS FOR EXTREME WEATHER CONDITIONS
MILITARY TEXTILE MATERIALS FOR EXTREME WEATHER CONDITIONS TSOUTSEOS Athanasios 1, PRINIOTAKIS Georgios 2 1 Hellenic Naval Forces, Naval Base of Salamis, Directorate DNX, 18900 Salamis, Greece, E-Mail:
More informationBenchmarking functionality of historical cold weather clothing: Robert F. Scott, Roald Amundsen, George Mallory
Loughborough University Institutional Repository Benchmarking functionality of historical cold weather clothing: Robert F. Scott, Roald Amundsen, George Mallory This item was submitted to Loughborough
More informationStudy of the required thermal insulation (IREQ) of clothing using infrared imaging. Tanveer Ahmad, Taimur Rashid, Hassan Abbas Khawaja
Study of the required thermal insulation (IREQ) of clothing using infrared imaging Tanveer Ahmad, Taimur Rashid, Hassan Abbas Khawaja Department of Engineering and Safety, UiT The Arctic University of
More informationLIGHTER WEIGHT MORE WARMTH ENHANCED FLEXIBILITY. A New Generation of Flame Resistant Outerwear Fabrics
LIGHTER WEIGHT MORE WARMTH ENHANCED FLEXIBILITY A New Generation of Flame Resistant Outerwear Fabrics LIGHTER WEIGHT MORE WARMTH ENHANCED FLEXIBILITY 3M Thinsulate Insulation FR Quilted to Westex Westex,
More informationDefense Technical Information Center Compilation Part Notice
UNCLASSIFIED Defense Technical Information Center Compilation Part Notice ADP012411 TITLE: A Sweating Agile Thermal Manikin [SAM] Developed to Test Complete Clothing Systems Under Normal and Extreme Conditions
More informationUNIFORM CATALOGUE 2016
UNIFORM CATALOGUE 2016 Thanks again for considering us for your 2016 Uniform Program. It has been a pleasure to work with Pepsi these many years and we appreciate the confidence and trust you place in
More informationShell Microspheres for Ultrahigh-Rate Intercalation Pseudocapacitors
Supplementary Information Nanoarchitectured Nb2O5 hollow, Nb2O5@carbon and NbO2@carbon Core- Shell Microspheres for Ultrahigh-Rate Intercalation Pseudocapacitors Lingping Kong, a Chuanfang Zhang, a Jitong
More informationMass Customization Methodology for Footwear Design
Mass Customization Methodology for Footwear Design Yifan Zhang 1, Ameersing Luximon 1, Xiao Ma 1, Xiaoling Guo 2, and Ming Zhang 3 1 Institute of Textiles and Clothing, The Hong Kong Polytechnic University,
More informationStaying safe and seen -
An Expert Advice Sheet Staying safe and seen - Hi-Vis Hazardwear EN Standards for Hi-Vis Clothing EN ISO 20471:2013 High-Visibility Clothing Test Methods and Requirements Professional clothing must withstand
More informationPRODUCT CATALOG
PRODUCT CATALOG 877.364.0070 WWW.SAFETYSUPPLYFACTORY.COM ALL PURPOSE MESH VESTS A1200 / A1200J (Jumbo size) / A1204 ORANGE A1201 / A1201J (Jumbo size) LIME 1 wide vertical reflective stripes All purpose
More informationMEASUREMENT OF PHYSIOLOGICAL PROPERTIES OF MILITARY CLOTHING IN SIMULATION OF CLIMATIC CONDITIONS IN SELECTED AREAS OF THE WORLD
MEASUREMENT OF PHYSIOLOGICAL PROPERTIES OF MILITARY CLOTHING IN SIMULATION OF CLIMATIC CONDITIONS IN SELECTED AREAS OF THE WORLD J. Švecová 1, A. Havelka 2 and L. Nagy 2 1 Department of Logistics, University
More informationWORK TROURSERS. Is also available in 100% cotton only black (style 626)
WORK TROURSERS Style 625 Work trousers in 65% polyester and 35% cotton with detachable pockets designed for nails and knee pad pockets in Cordura. 290 g/m2 Waist: 28-50 inches Length: 32 or 34 inches.
More informationPress information. All wrapped up. Warm outer layers for cold days. 22-Jan EN
Press information All wrapped up Warm outer layers for cold days 22-Jan-2015 452-EN BÖNNIGHEIM (ri) "There's no such thing as bad weather - just the wrong clothing". Every year, sudden changes in the weather
More informationUC Berkeley Indoor Environmental Quality (IEQ)
UC Berkeley Indoor Environmental Quality (IEQ) Title Versatile Indian sari: Clothing insulation with different drapes of typical sari ensembles Permalink https://escholarship.org/uc/item/1wp225b2 Authors
More informationTHE ERGONOMIC FACTORS: A STUDY ON ACTIVE WEAR. Kushanee Jayasinghe, 2 Niromi Seram. 2
THE ERGONOMIC FACTORS: A STUDY ON ACTIVE WEAR 1 Kushanee Jayasinghe, 2 Niromi Seram 1,2 Department of Textile & Clothing Technology, University of Moratuwa, Sri Lanka 1 kushaneej@gmail.com, 2 niromis@uom.lk
More informationPPE Information Sheet Protective Clothing for the Body
PPE Information Sheet Protective Clothing for the Body Introduction Certain work activities and situations may put workers at a risk of harm to their body and legs. Therefore, protective clothing will
More informationDiscover K&K Antistatic Garments Collection
Discover K&K Antistatic Garments Collection ESD Smock UX Design Comfortable and breathable static dissipative smock for use in EPA-Electrostatic Protective Area 3/4 length Easy snap fastening, hidden nickel-free
More informationInteraction of clothing and thermoregulation
Loughborough University Institutional Repository Interaction of clothing and thermoregulation This item was submitted to Loughborough University's Institutional Repository by the/an author. Citation: HAVENITH,
More informationInternational Journal of Fiber and Textile Research. ISSN Original Article NEW POSSIBILITIES IN KHADI DESIGNING
Available online at http://www.urpjournals.com International Journal of Fiber and Textile Research Universal Research Publications. All rights reserved ISSN 22777156 Original Article NEW POSSIBILITIES
More informationThink Before you Ink: Modeling Laser Tattoo Removal
Think Before you Ink: Modeling Laser Tattoo Removal BEE 453 May 1, 2008 Katherine Cumnock, Leigh Gerson, Jacqueline Stroncek, and Sarah Yagerman Table of Contents 1.0 Executive Summary. 3 2.0 Introduction..
More information1300 HIFLEX HRS - 7 DAYS
HIFLEX HI-VISIBILITY 3913 & 3911 Hivis D/N Cool-Breathe Polo Shirt With 3M 8906 R/Tape - Long Sleeve Fabric: 175gsm 100% polyester mircomesh, Two tone front and back. 3M 8906. COLOUR: ORANGE/NAVY 3992
More information3D Body Scanning Technology for Virtual Design of System "Body-Clothes"
3D Body Scanning Technology for Virtual Design of System "Body-Clothes" Victor E. KUZMICHEV* 1a, Natalia A. SAHAROVA a, Gregory I. CHISTOBORODOV a a Ivanovo State Textile Academy, Russia Abstract New systematic
More information