Assessment of Hypothermia Blankets Using an Advanced Thermal Manikin John P. Rugh 1* and Khalid Barazanji 2

Similar documents
Experimental Heated, Breathing and Sweating Manikins. Integrating radiant. Fatigue Lab constructs the. losses. military use. of human body heat

Interaction effects of radiation and convection measured by a thermal manikin wearing protective clothing with different radiant properties

Testing Services for the Evaluation of. Fabric Systems, Clothing Systems, Sleeping Bag Systems, Bedding Systems, and Personal Cooling Systems (PCS)

Comfort of Clothing. Rajesh Mishra & Jiri Militky Technical University of Liberec Liberec, Czech Republic

SCRUB SUITS VS CLEAN AIR SUITS A THERMAL PROPERTIES COMPARISON

Room Climate Standard. Thomas Wolf, CSES

Development of Empirical Equations to Predict Sweating Skin Surface Temperature for Thermal Manikins in Warm Environments.

INVESTIGATION OF HEAD COVERING AND THERMAL COMFORT IN RADIANT COOLING MALAYSIAN OFFICES

The Role of Tests and Manikin in Defining Fabrics Thermal Characteristics

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

A Comparison of Two Methods of Determining Thermal Properties of Footwear

A Comparative Introduction on Sweating Thermal Manikin Newton and Walter

8/2016. Protective clothing for firefighters TIGER MATRIX. 3rd category of Personal Protective Clothing

Clothing insulation From Wikipedia, the free encyclopedia

Supporting Material for TIA 1105 (2112)

FORCED VENTILATION OF PROTECTIVE GARMENTS FOR HOT INDUSTRIES. J.A. Gonzalez, L.G. Berglund, T.L. Endrusick*, M.A. Kolka

LIGHTER WEIGHT MORE WARMTH ENHANCED FLEXIBILITY. A New Generation of Flame Resistant Outerwear Fabrics

Research Article Artificial Neural Network Estimation of Thermal Insulation Value of Children s School Wear in Kuwait Classroom

School of Health Sciences, University of Wollongong, Wollongong, Australia. Contact person:

Impact of local clothing values on local skin temperature simulation

Measurement Method for the Solar Absorptance of a Standing Clothed Human Body

Published in: Proceedings of the 11th International Conference on Environmental Ergonomics

FIBER OPTIC IRONING DIODE LASER EPILATION!

An evaluation of the thermal protective clothing used by six Australian fire brigades

Applicability of the Thermal Manikin for Thermal Comfort Investigations

FIBER OPTIC IRONING DIODE LASER EPILASION!

CLI MATE PROTECTION SYSTE M S

Defense Technical Information Center Compilation Part Notice

SBS5225 HVACR I Thermal Comfort. Ir. Dr. Sam C. M. Hui Faculty of Science and Technology

The comparison of thermal properties of protective clothing using dry and sweating manikins

The effects of protective clothing on metabolic rate

Simulation of perspiration in sweating fabric manikin-walter

Webinar December 8, 2015

EVALUATION OF PHYSIOLOGICAL PROPERTIES OF THE FIRST LAYER GARMENT FOR SPORT APPAREL

Identifying a suitable method for studying thermal comfort in people s homes

CHAPTER 6 DESIGN AND DEVELOPMENT OF HOSPITAL BED LINEN

* Nara Women's University, Nara, Japan Nofer Institute of Occupational Medicine, Lo&, Poland

Dressing for the Outdoors Parents Information Pack

Outdoor Clothing Practitioners Guide

Professor Alan Hedge, Cornell University 1/22

The E ects of Wind and Human Movement on the Heat and Vapour Transfer Properties of Clothing

HASPI Medical Anatomy & Physiology 07c Lab Activity

KLOPMAN FABRICS WITH TENCEL COOLING EFFECT

An integrated approach to develop, validate and operate thermo-physiological human simulator for the development of protective clothing

EC Fabric Flammability and Clothing

TECHNICAL NOTE NO. TN16-1 DATE January 2016 ADA DEVELOPMENT OF MATLAB SCRIPTS FOR THE CALCULATION OF THERMAL MANIKIN REGIONAL RESISTANCE VALUES

ProCutiGen Hold Efficacy Data

Press information. All wrapped up. Warm outer layers for cold days. 22-Jan EN

Contact person:

Heat Balance When Wearing Protective Clothing

New Solder Attach Technologies Streamline Assembly in Application-Specific Designs

INTRODUCING NOMEX LIMITEDWEAR

Effect of Hair Style on Human Physiological Responses in a Hot Environment

To protect users or patients from infections

INFRA- STRUCTURE C LOT H ING S Y STEM S F O R TH E TO U GHEST CH A LLEN G ES

TopStyler User Manual

Manikin Design: A Case Study of Formula SAE Design Competition

Biomedical Research 2018; Special Issue: ISSN X Study on the effect of professional sports clothing on sports physiology.

Skin Temperature and Predicted Discomfort of Women Wearing Sheer Empire Style Dress

Galactic City Costume Club B-Wing Pilot (Episode VI) Standard

Fire & Life Safety Education

ALU-SAFE HAS BEEN TESTED AGAINST THE FOLLOWING STANDARDS: Full technical details and further information can be found at

Champion System RUNNING INFORMATION PACK. #beyourownbrand

Fume Hood ECON VAV Controls

The Use of 3D Anthropometric Data for Morphotype Analysis to Improve Fit and Grading Techniques The Results

Defense Technical Information Center Compilation Part Notice

NTC Project S02-CD01 (formerly I02-E01)

MEASUREMENT OF PHYSIOLOGICAL PROPERTIES OF MILITARY CLOTHING IN SIMULATION OF CLIMATIC CONDITIONS IN SELECTED AREAS OF THE WORLD

AC MOISTURE-PLEX ADVANCED PF. Hyaluronic Acid Alternative + Potent Moisturizer + Improves Barrier Integrity

Collin's Lab: Solar. Created by Collin Cunningham. Last updated on :15:11 AM EDT

Special textiles are the ideal solution for effective protection against harmful UV radiation. Hohenstein Institute

This document is a preview generated by EVS

VERBUND. Energy Transition. Harald Wechselberger RWEA Conference Bucharest, 30th th of October VERBUND AG,

3M Reflective Clothing

Foot and Calf Massager Model Number: FCM1000

Collecting Textiles: Make It Work for Your Community

Current cotton fiber market in Russia

MORE FORYOU WINTER ISSUE UPSELL HOODIES: DON'T LET IT BE A COMMODITY OUTERWEAR TRENDS FOR 2013 BEANIES, HEADBANDS, SCARFS & BLANKETS

Appropriate Workwear for Flash Fire and Explosion Hazards

Superior Technology 1 2 T

AC Foaming Wheat PF Efficacy Data

Levan. A Natural Anti-Aging Humectant

BAUER PROTECTIVE BASE LAYER

JE SPOLUFINANCOVÁN EVROPSKÝM SOCIÁLNÍM FONDEM A STÁTNÍM ROZPOČTEM ČESKÉ REPUBLIKY

FORMALDEHYDE EXPOSURE CONTROL PLAN

Innovation: because it matters. Flex technology for longer wear time

Unit Overview: Salon Safety and Infection Control

Technology to Defend Against Cold Stress

PRODUCT CATALOG

CARE OF THE SKIN: GUIDELINES FOR ENSURING SKIN INTEGRITY LESSON PLAN

TopStyler User Manual

Effects of Saw Ginning, Roller Ginning, and Lint Cleaning on Fiber Length Uniformity Index

TECHNICAL SPECIFICATION

REDEFINE. AMP MD System For Firmer-Looking Skin

An Ancient Mystery UNIT 6 WEEK 4. Read the article An Ancient Mystery before answering Numbers 1 through 5.

Research or experimental laboratory; Office building and/or office for governmental, business, professional or general purpose;

Testing Cold Protection According to EN ISO 20344: Is There Any Professional Footwear that Does Not Pass?

FR Disposable Clothing Guide

RSU270 COOL RIDE ZIP INNER JACKET

Overview. SKABT7 - SQA Unit Code HF8G 04. Carry out waxing services

Transcription:

Assessment of Hypothermia Blankets Using an Advanced Thermal Manikin John P. Rugh 1* and Khalid Barazanji 2 1 U.S. Department of Energy National Renewable Energy Laboratory, Golden, Colorado, USA 2 U.S. Army Aeromedical Research Laboratory, Fort Rucker, Alabama, USA Contact person: john.rugh@nrel.gov INTRODUCTION The U.S. Army Aeromedical Research Laboratory (USAARL) and the U.S. Department of Energy s National Renewable Energy Laboratory (NREL) used NREL s thermal manikin, controlled by a human thermal physiological model, to assess various hypothermia blankets. These blankets are important during medical transport because environmental conditions, coupled with a patient s traumatic injury, can often lead to physiological thermal imbalance. High wind and low air temperatures during a medical evacuation can lead to excessive heat loss from the patient, resulting in hypothermia. This condition can complicate the treatment of the patient upon arrival at the hospital. NREL s thermal comfort tools consist of the thermal comfort manikin (ADAM, for ADvanced Automotive Manikin), a physiological model, and a psychological model linked together to assess comfort in a transient, nonhomogeneous environment (1, 2). In the integrated human thermal comfort system, ADAM is controlled by a finite-element physiological model of the human body. The thermal manikin is a surface sensor that measures the rate of heat loss at 120 independently controlled zones. The skin heat transfer rates are sent to the physiological model, which computes the skin and internal temperature distribution and surface sweat rates. This information is then sent back to the manikin, which generates the prescribed skin temperatures, surface sweat rates, and breathing rates. As the model steps forward in time, this loop provides a transient measurement tool. The psychological comfort model uses temperature data from the physiological model to predict local and global thermal comfort as a function of local skin and core temperatures and their rates of change. METHODS Testing was conducted in NREL s Manikin Environmental Chamber in Golden, Colorado. The test conditions were 15ºC air temperature and 50% to 60% relative humidity. Three portable fans provided 7 mph airflow over the manikin. Four hypothermia blanket configurations were tested in conjunction with a stretcher: (1) wool army blanket (heat retention), (2) electric heating blanket, (3) radiant heating blanket, and (4) chemical heating blanket. The Army blanket was a standard-issue brown rectangular blanket. The electric heating blanket consisted of a lightweight inner wrap and an outer shell blanket containing heating elements. The radiant heating blanket used resistive carbon fiber technology * An employee of the Alliance for Sustainable Energy, LLC under Contract No. DE-AC36-08GO28308 with the U.S. Department of Energy has authored this work. The United States Government retains and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a non-exclusive, paid-up, irrevocable, worldwide license to publish or reproduce the published form of this work, or allow others to do so, for United States Government purposes.

with a microprocessor-controlled temperature regulation system. The radiant blanket contained five woven carbon fiber warming panels, each measuring 9 by 14 inches, designed to distribute heat evenly from the shoulders to below the feet. The chemical heating blanket system consisted of a sheet next to the patient, a thin blanket containing the chemical, and an outer radiation shield. The sheet was a regular bed sheet placed between the manikin and the chemical blanket to protect the skin from excessive temperature. The chemical blanket layer had six pouches measuring 7 by 10 inches containing the chemical material that generated heat when exposed to air. The outer shield was 88 by 93 inches and had a reflective inner surface to reflect body heat back to the patient. Thermocouples were secured to the chemical blanket layer to assess potential hot spots. The manikin was placed on an actual medical evacuation stretcher made of a mesh material and a frame that allowed air flow under the patient. The manikin was unclothed under the thermal blankets, and the manikin s uncovered head extended beyond the edge of the blanket. Figure 1 shows ADAM testing the wool Army blanket. Figure 2 shows the electric and radiant heating blankets, and Figure 3 shows the chemical blanket. Figure 1. Test of a Wool Army Blanket Using the Thermal Manikin Figure 2. Electric and Radiant Heating Blankets

Figure 3. IR Image of the Chemical Blanket and Photo of the Outer Radiation Shield During the first part of the test, the steady-state heat loss from the manikin was measured at constant skin temperatures of 34ºC and 40ºC for each blanket configuration. We found that a skin temperature of 34ºC was not hot enough for active blanket configurations. When the zone skin temperature exceeded 34ºC, the heater turned off and there was no longer active control for that zone. Therefore, we had to increase to a skin control temperature of 40ºC for the steadystate tests to increase the number of segments with active control. Immediately after the steady-state constant skin temperature test, the manikin was controlled with the physiological model, and the metabolic rate was set at 95 W. The test was run until a steady-state core temperature was attained. Key outputs of skin and core temperature were compared for each blanket configuration. The core temperature was defined as a volume average temperature of the brain. This was useful for a run-to-run comparison, but it should not be used to define the onset of hypothermia. A different definition of core temperature would produce a different result. The average skin temperature was defined as an average of 16 skin temperatures distributed around the body. RESULTS The constant skin temperature steady-state results are shown in Figure 4. When wrapped in a wool blanket, the manikin measured a 205.5 W/m 2 heat loss. The test of the electric blanket resulted in a higher heat loss, and that of the radiant blanket produced a lower heat loss. The heat loss result for the chemical blanket was significantly lower, at 79.5 W/m 2. This finding was mainly due to the outer radiation shield of the chemical heating blanket system. Tests performed without having the radiation shield well wrapped and without the radiation shield altogether yielded higher heat losses.

Temperature ( o C) Heat Loss from ADAM (W/m 2 ) USAARL Test with ADAM, Tair=15 o C, Tskin = 40 o C 300 263.3 250 200 205.5 182.0 150 100 79.5 50 0 Wool Blanket Electric Blanket Radiant Blanket Chemical/radiation shield with double sheet Figure 4. Steady-State Heat Loss with 40 C Skin Temperature Controlling the manikin with the physiological model yielded results that were similar to those of the constant skin temperature tests. Figure 5 shows that the wool blanket produced a manikin core temperature of 33.9 C. The test of the electric blanket resulted in the lowest core temperature, and that of the chemical blanket produced the highest core temperature of 35.4 C. The skin temperatures were consistent with the core temperature results, except for the electric blanket. In that case, the average skin temperature was warmer than the wool blanket, while the core temperature was cooler. The chest and leg temperatures were warmer, but there was greater heat loss and lower skin temperatures on the manikin s sides and back. The average skin temperature calculation was constrained to 16 points and missed these cool spots. The manikin with physiological model control responded to the environment with higher fidelity and measured a lower core temperature. USAARL The Test with chemical ADAM, Tair=15 blanket test resulted in the warmest skin o C, Model Control temperatures, although this blanket produced hot spots up to 70ºC on the surface of the blanket. 36 35 Core Temperature Skin Temperature (16 point average) 35.4 35.9 34 33.9 34.1 34.4 33 33.4 32 32.0 32.6 31 30 29 Wool Blanket Electric Blanket Radiant Blanket Chemical/radiation shield with double sheet Figure 5. Average Skin and Core Temperatures during Physiological Model Control

Heat Loss from ADAM (W/m 2 ) For the wool, electric, and radiant blanket tests, placing a wool blanket between the manikin and stretcher significantly reduced heat loss (Figure 6). For the wool blanket case, placing a wool blanket under the manikin resulted in a 30% reduction in heat loss, to 144.4 W/m 2. This was a better result than those for the regular electric and radiant blankets. The chemical blanket was not impacted by placing the wool blanket underneath it because it was already well wrapped and insulated because of the radiation shield. Placing a radiation shield around a wool blanket with wool underneath resulted in an additional 30% drop in heat loss, from 144.4 to 101.8 W/m 2 USAARL Test with ADAM, Tair=15 o C, Tskin = 40 o C. 300 250 263.3 Manikin directly on stretcher Manikin on wool blanket on stretcher 200 205.5 182.0 150 144.4 125.5 100 106.4 79.5 86.3 50 0 Wool Blanket Electric Blanket Radiant Blanket Chemical/radiation shield with double sheet CONCLUSIONS Figure 6. Impact on Heat Loss of Placing a Wool Blanket under the Manikin The thermal manikin was successfully used to assess thermal blankets. The chemical blanket showed the best thermal performance, specifically, the lowest heat loss and the highest skin and core temperatures. Care providers should not place a chemical heating blanket directly on the patient s skin, however. The electric blanket showed the highest heat loss and coolest core temperature. Placing a wool blanket between the manikin and the stretcher significantly reduced heat loss when the wool, electric, and radiant blankets were used. Wrapping a radiation shield around a conventional wool blanket and using a wool blanket underneath the patient further reduced heat loss. REFERENCES 1. Rugh, J.; Bharathan, D. "Predicting Human Thermal Comfort in Automobiles." Seventh Vehicle Thermal Management Systems Conference Proceedings; May 10-12, 2005, Toronto, Canada. SAE Paper No. 2005-01-2008. 2. Rugh, J.; Lustbader, J. "Application of a Sweating Manikin Controlled by a Human Physiological Model and Lessons Learned." Sixth International Meeting on Thermal Manikins and Modeling (613M) Proceedings; October 17-18, 2006.