The issue of thermal comfort of medical clothing in the operating room 1

Development of Empirical Equations to Predict Sweating Skin Surface Temperature for Thermal Manikins in Warm Environments.

A Comparison of Two Methods of Determining Thermal Properties of Footwear

A Comparative Introduction on Sweating Thermal Manikin Newton and Walter

Interaction effects of radiation and convection measured by a thermal manikin wearing protective clothing with different radiant properties

Comfort of Clothing. Rajesh Mishra & Jiri Militky Technical University of Liberec Liberec, Czech Republic

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Clothing insulation From Wikipedia, the free encyclopedia

FORCED VENTILATION OF PROTECTIVE GARMENTS FOR HOT INDUSTRIES. J.A. Gonzalez, L.G. Berglund, T.L. Endrusick*, M.A. Kolka

Measurement Method for the Solar Absorptance of a Standing Clothed Human Body

Assessment of Hypothermia Blankets Using an Advanced Thermal Manikin John P. Rugh 1* and Khalid Barazanji 2

Research Article Artificial Neural Network Estimation of Thermal Insulation Value of Children s School Wear in Kuwait Classroom

The comparison of thermal properties of protective clothing using dry and sweating manikins

Room Climate Standard. Thomas Wolf, CSES

INVESTIGATION OF HEAD COVERING AND THERMAL COMFORT IN RADIANT COOLING MALAYSIAN OFFICES

PP protective gown. PP protective, disposable gown. Use. Features

SBS5225 HVACR I Thermal Comfort. Ir. Dr. Sam C. M. Hui Faculty of Science and Technology

Professor Alan Hedge, Cornell University 1/22

Impact of local clothing values on local skin temperature simulation

MEASUREMENT OF PHYSIOLOGICAL PROPERTIES OF MILITARY CLOTHING IN SIMULATION OF CLIMATIC CONDITIONS IN SELECTED AREAS OF THE WORLD

Headwear. Gowns. Shoe Cover. Aprons. Bed linen

CHAPTER 6 DESIGN AND DEVELOPMENT OF HOSPITAL BED LINEN

The Use of 3D Anthropometric Data for Morphotype Analysis to Improve Fit and Grading Techniques The Results

Simulation of perspiration in sweating fabric manikin-walter

LIGHTER WEIGHT MORE WARMTH ENHANCED FLEXIBILITY. A New Generation of Flame Resistant Outerwear Fabrics

Heat Balance When Wearing Protective Clothing

THE COMFORT, MEASURED BY MEANS OF A SWEATING MANIKIN (WALTER TM ), OF CLOTHING CONTAINING DIFFERENT FIBRE COMBINA- TIONS: A PRELIMINARY INVESTIGATION

Prediction of Clothing Thermal Insulation and Moisture Vapour Resistance of the Clothed Body Walking in Wind

EVALUATION OF PHYSIOLOGICAL PROPERTIES OF THE FIRST LAYER GARMENT FOR SPORT APPAREL

IDENTIFICATION OF PREPONDERANT FACTORS FOR WORK-WEAR DESIGN

Webinar December 8, 2015

Testing Services for the Evaluation of. Fabric Systems, Clothing Systems, Sleeping Bag Systems, Bedding Systems, and Personal Cooling Systems (PCS)

VWR Garments for Laboratories and Clean Rooms!

Determination of the Air Gap Thickness underneath the Garment for Lower Body Using 3D Body Scanning

Improving Men s Underwear Design by 3D Body Scanning Technology

An evaluation of the thermal protective clothing used by six Australian fire brigades

Published in: Proceedings of the 11th International Conference on Environmental Ergonomics

School of Health Sciences, University of Wollongong, Wollongong, Australia. Contact person:

CHAPTER 4 INFLUENCE OF LYOCELL FIBER BLENDS ON THE COMFORT CHARACTREISTICS OF HOSPITAL TEXTILES

VWR Garments for Laboratories and Clean Rooms!

The Role of Tests and Manikin in Defining Fabrics Thermal Characteristics

Identifying a suitable method for studying thermal comfort in people s homes

The E ects of Wind and Human Movement on the Heat and Vapour Transfer Properties of Clothing

* Nara Women's University, Nara, Japan Nofer Institute of Occupational Medicine, Lo&, Poland

ISO INTERNATIONAL STANDARD. Protective clothing for protection against chemicals Classification, labelling and performance requirements

Effect of Hair Style on Human Physiological Responses in a Hot Environment

SURGICAL GOWN REQUIREMENTS CAPTURE: A Design Analysis Case Study

Influence of Undergarment Structure on the Parameters of the Microclimate under Hermetic Protective Clothing

Comparison of Women s Sizes from SizeUSA and ASTM D Sizing Standard with Focus on the Potential for Mass Customization

The Fiber Society 2016 Spring Conference. May 25 27, Conference Chairs

8/2016. Protective clothing for firefighters TIGER MATRIX. 3rd category of Personal Protective Clothing

UC Berkeley Indoor Environmental Quality (IEQ)

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Local air gap thickness model for realistic simulation of thermal effects in clothing

Protective Clothing and Medical Devices

Investigation into Fit, Distribution and Size of Air Gaps in Fire-Fighter Jackets to Female Body Form

International Journal of Fiber and Textile Research. ISSN Original Article NEW POSSIBILITIES IN KHADI DESIGNING

Single-use vs. reusable garment solution

Contact person:

HARTMANN Folio Surgical Solutions. Providing optimum infection prevention for your surgery

International Journal of Modern Trends in Engineering and Research. Effects of Jute Fiber on Compaction Test

Defense Technical Information Center Compilation Part Notice

Testing Cold Protection According to EN ISO 20344: Is There Any Professional Footwear that Does Not Pass?

Press information. All wrapped up. Warm outer layers for cold days. 22-Jan EN

Surgical Product Catalogue

ISSN: [Hanan* et al., 7(7): July, 2018] Impact Factor: 5.164

DuPont Personal Protection. Chemical Protective Clothing Solutions

HI-TEC Alginate Wound Care Dressing

e ISSN Open Access -

KLOPMAN FABRICS WITH TENCEL COOLING EFFECT

FR Disposable Clothing Guide

UC Berkeley Indoor Environmental Quality (IEQ)

Services for Personal Protective Equipment Testing and certification

Subject : Apparel Merchandising. Unit 1 Introduction to apparel merchandising. Quadrant 1 e-text

Biomedical Research 2018; Special Issue: ISSN X Study on the effect of professional sports clothing on sports physiology.

FORMATION OF NOVEL COMPOSITE FIBRES EXHIBITING THERMOCHROMIC BEHAVIOUR

Experimental Heated, Breathing and Sweating Manikins. Integrating radiant. Fatigue Lab constructs the. losses. military use. of human body heat

Applicability of the Thermal Manikin for Thermal Comfort Investigations

Parallel and Serial Methods of Calculating Thermal Insulation in European Manikin Standards

MAKING SURE YOU ARE COMPLETELY. COVERALL: HABETEX Micronplus

HKRITA Garners Admirable Accolades in the International Exhibition of Inventions of Geneva

INTRODUCING NOMEX LIMITEDWEAR

Disposable Apparel Performance and Selection Guide

ALU-SAFE HAS BEEN TESTED AGAINST THE FOLLOWING STANDARDS: Full technical details and further information can be found at

A Novel Approach for Fit Analysis of Protective Clothing Using Three-Dimensional Body Scanning

To protect users or patients from infections

The effects of protective clothing on metabolic rate

This document is a preview generated by EVS

The interaction of clothing. ventilation with dry and evaporative heat transfer of jackets: the effect of air and. vapor permeability

PROFESSIONAL WORKWEAR FOR THE CLEANROOM

DUST-FREE. MAKING SURE YOU ARE COMPLETELY

ETSA requirements for workwear garments

Wearing Effectiveness of the Nowire Mold-Bressiere Design

OPTIMIZATION OF MILITARY GARMENT FIT

Performance Study of Protective Clothing against Hot Water Splashes: from Bench Scale Test to Instrumented Manikin Test

Clinical Disposables Range

OWN BRANDS AND PRIVATE LABEL IN THE PORTUGUESE FASHION INDUSTRY

International Journal of Science, Technology & Management Volume No 04, Special Issue No. 01, March 2015 ISSN (online): TEXTILES IN SPORTS

Laboratory assessment of cold weather clothing

CLOTHING REAL EVAPORATIVE RESISTANCE DETERMINED BY MEANS OF A SWEATING THERMAL MANIKIN: A NEW ROUND-ROBIN STUDY

This document is a preview generated by EVS

Transcription:

SCRUB SUITS VS CLEAN AIR SUITS A THERMAL PROPERTIES COMPARISON Isabel ABREU; Patrícia RIBEIRO & Maria José ABREU Abstract: In operationg room (OR), the health professionals are exposed to stress situations that can influence their physical and psychological performance. The thermal properties are an important requirement for the best performance of OR medical clothing, that plays a crucial role in thermal comfort of the user, that involve the regulation of heat and mass transfer between a clothed body and the environment. In this way, the aim of this work was comparison of thermal properties between scrub and clean air suits. The test was performed on a thermal manikin and Alambeta to measure clothing insulation and to evaluate the thermal comfort. These tests provide a good estimate of the total dry heat loss from the body and the distribution of heat flow between body surface and textile materials. Keywords: Scrub suit, clean air suit, comfort, thermal properties, thermal manikin, Alambeta 1. Introduction Over the last years, surgical scrub suits (SS) have been worn by health care workers in the operation room (OR) and for many other applications in healthcare outside the OR. They are used by health professionals as uniform. However, scrub suits are not considered a medical device, so there is no defined regulation nether scientific studies support the practice of using scrub suits as a means for preventing transmission of infection [1]. On the other hand, clean air suits (CAS) are considered Class I medical devices according to the definition and classification rules of the Medical Devices Directive 93/42/EEC, amended by 2007/47/EC [2]. Clean air suit is defined as a suit intended and shown to minimize contamination of the operating wound by the wearer's skin scales carrying infective agents via the operating room air thereby reducing the risk of wound infection by EN 13795:2011+A1:2013 [3]. In Figure 1 can be seen the appearance of a scrub suit and a clean air suit. The standard EN 13795 presents general performance requirements concerning properties which require assessment in CAS like resistance to microbial penetration, microbial and particle matter cleanliness, linting, bursting strength and tensile strength [3]. As further characteristic of medical clothing, EN 13795 takes in consideration the comfort of the users. Inside of OR, thermal comfort of medical clothing apparel is a very important parameter, since the lack of comfort can lead to thermal stress that influence the physic and psychological conditions of the surgeon, as the ability to maintain constant vigilance and concentration, which the correct surgical procedure is dependent. Thermal comfort of the user of medical apparel depends on thermal properties and its adjustment to the environmental conditions in the OR during the surgery, among many other factors like design, size and fabric characteristics [4]. Extremely insulating and low absorbent medical apparel will results in an increase of skin temperature, leading to a greater moisture accumulation between professional skin and clothing. To overcome this situation, surgical clothing needs to satisfy some requirements; they should be comfortable, breathable, loose fitting, keep the user in cool conditions and allow heat changes between the body and environment [5]. For health professional can achieve thermal comfort, the mean skin temperature should be between 33 C and 34 C and sweating or chills should not occur. Studies have determined that surgeons experience thermal comfort when OR temperature is between 20 C and 24 C and if their clothing ensemble were consisted by shoes, cotton socks, nonwoven surgical clothing with viscose fiber and good air and water vapour permeability [6]. In this way, the aim of the presented study was to compare thermal properties between scrub and clean air suits. 337

7th INTERNATIONAL TEXTILE, CLOTHING & DESIGN CONFERENCE Magic World of Textiles October 05th to 08th 2014, DUBROVNIK, CROATIA a b Figure 1: Scrub suits (a) and clean air suits (b). 2. Materials and Methods 2.1 Clothing ensemble Disposable and reusable scrub and clean air suits were used in this study, Table 1. The clothing was stabilized on adiabatic chamber before each test. Table 1: Description of clothing ensemble tested. Reference A B C D 2.2 Clothing ensemble Single-use scrub suit Reusable scrub suit Single use clean air suit Reusable clean air suit Composition Non-woven SMS 67% PES/ 33% cotton Non-woven SMS 99% PES/ 1% carbon fibre Alambeta Alambeta measuring device (Figure 2) is the fast measuring of transient and steady state thermo-physical properties (thermal insulation and thermal contact properties) [7], which simulates, during a very small initial contact, the heat flux between skin and fabrics. Alambeta measures thermal parameters like, thermal conductivity, resistance, diffusivity and absorbance. Figure 2: Alambeta equipment for thermal properties measurement. 338

7th INTERNATIONAL TEXTILE, CLOTHING & DESIGN CONFERENCE Magic World of Textiles October 05th to 08th 2014, DUBROVNIK, CROATIA 2.3 Thermal Manikin The thermal insulation of clothing ensemble was measured using a thermal manikin (Figure 3) with controlled skin surface temperature. This thermal manikin called has a woman s body; its size and configurations are similar to an adult woman. It is divided in 20 thermally independent sections and only sense dry heat transfer. Thermal manikin, positioned 0.1 m from the floor, was kept standing with their legs and arms held in vertical position without any motion. The skin temperature was set, and during the test period maintained at 33 ± 0.1 C. The tests were conducted in a climatic chamber where ambient conditions characteristic of an operating theatre were simulated, 20 C ± 2 C and 60% Rh. The climatic chamber can achieve temperatures around 15 C to 35 C and relative humidity around 35% to 85%. a b Figure 3: Thermal manikin: photo of nude thermal manikin used on tests(a) and software body picture of thermal manikin and color legend of body segments temperature (b). Heat flux lost was recorded and thermal insulation calculated according to global method, Equation 1, where 2 [ C] is the mean skin temperature, [ C] is the room temperature, [W/m ] the sensible heat flux of the manikin and fi the relationship between the surface area of segment i of the manikin [8]. This is the general formula for defining the whole body resistance and the one that best fits the definition of thermal insulation expressed [9]. Furthermore, global method is less susceptible to significant variations to calculate thermal insulation (1) The effective clothing insulation (Icle), consisting of the difference between IT and Ia are calculated by the Equation 2, considering Ia is measured by operating the manikin nude: (2) 3. Results 3.1 Alambeta Figure 4 shows thermal properties of tested clothing. Scrub suits have higher conductivity than CAS. SS B has cotton in its composition; which has higher conductivity than polyester, reason why it has higher conductivity than CAS D. Scrub suits have higher diffusivity than clean air suits. This property represents heat propagation velocity of material, so SS will diffuse the heat faster than CAS. Thermal absorptivity is a warm-cool feeling parameter and represents instantaneous heat flow that appends when two bodies, with different temperatures, come into contact. The higher is the thermal absorptivity, the 339

higher is the thermal flow and the worse is the initial contact sensation, because it corresponds to a cooler surface. This property is also related with structure and fabric composition. Single-use scrub suit and clean air suit have the same absorptivity value and it is lower than for reusable SS and CAS. Each material that can absorbs and conducts heat well, will easily remove the heat from the skin and make the user feels fresher [10]. a b Figure 4: Thermal properties of clothing measured on Alambeta: condutivity (a), diffusitivity (b) and absoptivity (c). 3.2 Thermal Manikin c Figure 5 shows the heat loss from manikin body segments. According to Hensel citated in [10], the higher is the heat loss from the skin to the environment, the faster the temperature will drops and more intense is the freshness feeling. So, as said earlier, the material that could absorb and conduct heat well, will remove heat from the skin and give the sensation of being a coolest garment. Hence, heat loss is closely related to thermal insulation, they are inversely proportional parameters. In this particular case, as expected, unclothed parts like feet, hands, forearms and face have higher heat loss. The differences of heat loss between SS and CAS are not significant. Figure 5: Heat loss from body section of manikin dressed with CAS (a) and SS (b). 340

Through heat loss values, total (I T ) and effective clothing thermal insulation (I cle ) can be calculated. In Figure 6 can be seen that SS A have the lower thermal insulation, the difference between single use scrub and clean air suits (A and C) is around 15% and for disposable ones (B and D) it is around 6%. However, the difference between SS and CAS is significant when we compare SS A with CAS C, and there is also a significant difference between scrub suits A and B. Despite of being made of same fabric, disposable SS and CAS (A and C) have different insulation behaviour. This can be possibly due to the design and lining of CAS. CAS openings for head, arms, waist and feet are closed by tightly fitting cuffs and the heat loss through these openings is lower and the thermal insulation increases. Moreover, this CAS has lining in upper part of shirt and trousers, which can also result in increased insulation. When the effect of air layer thermal insulation is removed (I cle ), clothing thermal insulation decreases but show the same behaviour. For A suit, can be observed a decrease around 73%, about 58% and 57% for B and C, respectively, and 61% for D. Figure 6: Total thermal insulation and effective clothing insulation of scrub and clean air suits. Thermal insulation of clothing can also be expressed in Clo. The higher the value of Clo, the greater is thermal insulation. Clo value of 1 is defined as the amount of clothing required to a human being at rest to be comfortable at room temperature of 21 C [10]. In this way, A suits has the closer Clo value from being thermal comfortable. Figure 7: Total thermal insulation of scrub and clean air suits. 4. Conclusion This study was performed to compare thermal properties between scrub suits and clean air suits made of woven and nonwoven fabric. Thermal properties of fabric were measured on Alambeta and thermal insulation of clothing was carried on a thermal manikin. Regarding to fabric thermal properties there is no suit with all ideal properties. Reusable SS and CAS have similar conductivity, but in terms of diffusivity they are almost the opposites. Concerning to the thermal insulation of clothing, it is dependent upon their specific design, size and fabric characteristics, particularly air space between skin and clothing that represents the main percentage of thermal insulation, always above 55%. 341

Acknowledgments The financial funding from QREN, POFC, Vale Inovação Project Nº 2012/24228 is also gratefully acknowledged. References [1] Abreu, M. J.: Prevention of airbone disposal from staff in the O.R. reducing the risk of infection: What are the benefits of using clean air suits or scrub suits? Proceeding book of International Symposium on Occupational Safety and Hygiene. ISBN: 978-972-99504-9-0, Guimarães, February 2012, Portuguese Society of Occupational Safety and Hygiene (SPOSHO), Guimarães, (2012). [2] Council Directive 93/42/EEC of the European Parliament and of the Council of 14 June 1993 concerning medical devices. Official Journal L 169, 12.7.1993, pp. 1. [3] EN 13795:2011+A1:2013, Surgical drapes, gowns and clean air suits, used as medical devices for patients, clinical staff and equipment General requirements for manufacturers, processors and products, test methods, performance requirements and performance levels. [4] Cho, J. S.; Tanabe, S. I.; Cho, G.: Thermal Comfort Properties of Cotton and Nonwoven Surgical Gowns with Dual Function Finish. Applied Human Science, Vol. 16 (1997), No. 3, pp. 87-95. [5] Fanger P.O.: Assessment of man's thermal comfort in practice. British Journal of Industrial Medicine Vol. 30 (1973), pp. 313-24. [6] ISO 9920:2007, Ergonomics of the thermal environment -- Estimation of thermal insulation and water vapour resistance of a clothing ensemble. [7] Bogdan A., Sudol-Szopinska I., Szopinski T.: Assessment of Textiles for Use in Operating Theatres with respect to the Thermal Comfort of Surgeons. Fibres & Textiles in Eastern Europe, Vol. 19 (2011), pp. 65-69. [8] Devanand U.: Objective Measurement of Heat Transport through Clothing, International Journal of Engineering Research and Development, Vol. 2 (2012), Issue 12, pp. 43-47, e-issn: 2278-067X. [9] Oliveira AV, et al.: Measuring thermal insulation of clothing with different manikin control methods. Comparative analysis of the calculation method., Proceedings Book of 7th International Thermal Manikin and Modelling Meeting, Coimbra, Portugal, September 2008. [10] Song, G.: Improving Comfort in Clothing. Woodhead Publishing. ISBN: 978-1-84569-539-2. (2011). Author(s): Isabel ABREU, MSc 2C2T - Centre of Textile Science and Technology; Department of Textile Engineering; University of Minho; Campus de Azurém Alameda da Universidade; 4800-058 Guimarães; Portugal E-mail: isabelabreu15@hotmail.com Patrícia RIBEIRO, B 2C2T - Centre of Textile Science and Technology; Department of Textile Engineering; University of Minho; Campus de Azurém Alameda da Universidade; 4800-058 Guimarães; Portugal E-mail: patricia.ri1990@gmail.com Prof. Maria José ABREU, Ph.D. 2C2T - Centre of Textile Science and Technology; Department of Textile Engineering; University of Minho; Campus de Azurém Alameda da Universidade; 4800-058 Guimarães; Portugal Tel. +351-253510274 E-mail: josi@det.uminho.pt 342