Wet/ Tank Blotting System

Similar documents
Western Blotting Systems CAT NO:EPS-B0015 & EPS-B0016

E-Blotter Operation. Technical Bulletin E-03 MATERIAL PROCEDURE

CosmoPage Dual Run & Blot System

KERATIN CONTAMINATION

Comparative Proteomics Kit II: Western Blot Module Quick Guide

iblot Dry Blotting System

Mini Blot Module. For transfer of proteins using the Mini Gel Tank USER GUIDE. Online Specials. Catalog Number B1000

iblot 2 Dry Blotting System

WHAT IS GEL ELECTROPHORESIS?

Optiblot Non-Reducing Electrophoresis Kit

Optiblot SDS-PAGE Gel

EXERCISE 8C - Lab Procedures

Dual Cool Run & Blot Mini-Vertical PAGE System (DCX-700)

Optiblot SDS-PAGE Gel

SureCast Handcast System For preparation of handcast mini gels for use with the Mini Gel Tank and XCell Surelock systems

Optiblot SDS-PAGE Gel

Glycoprotein Staining Kit

VisPRO 5 Minutes Protein Stain Kit

TEO ClearPAGE Precast Gel Running Instructions for SDS PAGE and DNA/Native Gels. Table of Contents

Instruction Manual OmniPAGE Vertical Electrophoresis Units. Catalogue Numbers

StainEase Gel Staining Tray

Instruction Manual OmniPAGE Vertical Electrophoresis Units. Catalogue Numbers

Student Manual SO 3 N N N + Blue 1 Yellow 5 N N. Yellow 6 Red 40. Fig. 3. Reference dyes used in this experiment. - O 3 S - OOC

FULL USER MANUAL. About GLO-ME

Procedure 30 Collecting A Blood Specimen Using The Vacuum-Tube System. Procedure 31 Collecting A Blood Specimen Using A Needle And Syringe

Vertical Gel Electrophoresis System. Instruction Manual

Standard Laboratory Practice for Consumer Applied Pet Stain and Odor Removal Chemical Evaluation on Pile Yarn Floor Coverings

Student Manual SO 3 N N N + Blue 1 Yellow 5 N N. Yellow 6 Red 40. Fig. 3. Reference dyes used in this experiment. - O 3 S - OOC

Copper Stain & Destain Kit for Electrophoresis Instruction Manual. Catalog Number

Protein Electrophoresis

Preparing the Gel Box and Pouring the Agarose Gel

Operating Instructions & Warranty Information

Cartridge Machine USER MANUAL

ROBOT PIN TOOL CLEANING AND LIQUID SAMPLE TRANSFER

Bano washbasin / brackets / outflow pipe / height adjustable module

Epic zen ze i n thi h nt n er e io r rs io. rs c. o c m o

CARE & MAINTENANCE. Keep your windows looking and working great

Hoefer SE615 and SE675

Care & Maintenance. Keep your windows looking and working great.

zenithinteriors.com Epic MELBOURNE SYDNEY CANBERRA BRISBANE PERTH ADELAIDE AUCKLAND WELLINGTON SHANGHAI HONG KONG

This bulletin gives specific instructions for application of Avery Dennison translucent film to recommended flexible-face signage material.

Charging base. Trimming head (30mm) on charging stand. Main body unit. On/Off switch. Indicated light. Connecting jack Connecting jack

Sterilization A Training Module

PET Barrier Test PET- R- 02

PreShave Power Cleanser

Cleaning order for FunderMax panels

What is infection control?

Standard Operating Procedures

LADY SHAVER WASHABLE LS 7140

SYPRO Orange and SYPRO Red Protein Gel Stains

Series 7. Series7. trimmer. Series 7. off. sensitive. intensive. clean. high. low. empty. reset

Hand Care and Hand Hygiene

Table 6: Detailed Infection Prevention and Control Procedures for Tattooing and Micropigmentation. Use During Tattooing

Series7. Series 7. trimmer. Series cc. off. sensitive. intensive. clean. high. low. empty. reset

SPIFE TOUCH SPE Procedure

CoolTec. CT6cc CT5cc CT4cc CT4s CT3cc CT2cc CT2s. Type 5676

PERFORMANCE EVALUATION BRIEF

Phenion FT Skin Model Histological processing Paraffin sections

Series7. Series 7. trimmer. Series 7. off. sensitive. intensive. clean. high. low. empty. reset

2.6-1 SCIENCE EXPERIMENTS ON FILE Revised Edition. Cloud Chamber

Exfoliate, Enhance and Smooth. User Manual & Warranty Information Model ST257

ROTARY PEN USER MANUAL

Series 5. Series cc. Type Series 7. trimmer. Series 7. off. 760 cc. sensitive. intensive. clean. reset

Airbrush Cleaning Manual. 1. Do's and Don'ts of Airbrush Cleaning

Introductory Chemistry

Instruction Booklet FOR AGES 6 AND UP Conforms to ASTM D-4236 No VISIT OUR WEBSITE:

PREPARATION OF BLOOD FILMS FOR MALARIA DETECTION

SYPRO Orange and SYPRO Red Protein Gel Stains

Exfoliate & Cleanse. Instructions for Use & Warranty Information Model ST102

Prosonic TM. trimmer. off. eco. normal. clean. intensive. high. auto select. low. empty. reset

2 in 1Hydro peel machine

The MiniOne TM Reagent Kit: Crime Scene Invesitigation

5 in1. Hair & Beard Trimmer. with accessories. Instruction Manual V

Instructions and Safety notices

V-Solder BON-7103/7203

CHM111 Lab Physical Separations Grading Rubric

Lab Safety & Volume Measurement. Virtual Science University

Experiment #3. Physical Separations Candy Chromatography

Prosonic TM. 790 cc. Type trimmer. off. eco. normal. clean. intensive. high. auto select. low. empty. reset

Series cc. Series 7. Type Series 7. trimmer. Series cc. off. sensitive. intensive. clean. high. low. empty.

Experiment 11 Identification of Food Colors in Candies

Remove most stains with one of the following steps:

Student Performance Guide. Student Performance Guide. Student Performance Guide. Student Performance Guide. LESSON 3-3 Bleeding Time

Prosonic BS washable clean. trimmer. off. eco. normal. intensive. high. auto select. low. empty. reset

GENTLE SKINCARE & HAIR REMOVAL SYSTEM

Metal And Canvas Double Robe

FAST FACTS ABOUT GNLD

Operating Instructions

WASHABLE NOSE, EAR & EYEBROW TRIMMER

Care and Operation of Preservation Premium Windows H I G H - P E R F O R M A N C E W I N D O W S

Congratulations on your purchase of a. airbrush. CN GRAVITY-FEED DUAL-ACTION AIRBRUSH. color cup. main lever. needle cap. nozzle cap.

LAB 5 Blood Collection

TopStyler User Manual

Certificate of Manufacturer s Warranty

Standard Operating Procedures

Market Hog Identification

Aseptic Milk Sampling for Bacteriology

Cleaning Instructions

BODY & BIKINI KIT 2 YEAR WARRANTY WPG4020AU USE & CARE MANUAL. To register your product go to PLEASE READ PRIOR TO USE

Tips On Proper Instrument Cleaning, Handling and Maintenance!

Transcription:

A Geno Technology, Inc. (USA) brand name Wet/ Tank Blotting System Cat. No. BT301 1-800-628-7730 1-314-991-6034 info@btlabsystems.com

SPECIAL NOTE: Thanks for choosing BT Lab Systems BT301 Wet/ Tank Blotting System. To insure the best performance from our Wet/ Tank Blotting System, please become fully acquainted with these operating instructions before using the cell. We recommend that you should first read these instructions carefully. Then assemble and disassemble the cell completely without transferring a gel. After these preliminary steps, you should be ready to run and transfer a gel. We recommend that all the components and accessories of the Wet/ Tank Blotting System be cleaned with a suitable laboratory cleaner, and rinsed thoroughly with distilled water before use. BT301 Wet/ Tank Blotting Systems are for laboratory use only. Please don t use it for purposes other than those for which they are intended. INTRODUCTION The Wet/ Tank Blotting System is used together with electrophoresis power supply and BT201 Wet/ Tank Blotting System, it accommodates two gel holder cassettes for electrophoresis transfer of both gels generated by BT201. The instrument is useful for blotting either protein or nucleic acid samples from both agarose and acrylamide gels and can identify their homology. The important part of the Wet/ Tank Blotting System is its main body, which has the capacity to hold two gel holder cassettes for electrophoresis transfer between the parallel electrodes that are only 4.5 cm apart. The driving force for blotting applications is the voltage applied over the distance between the electrodes. This short 4.5 cm electrode distance allows generation to produce efficient protein transfers. Other features of the instrument includes latches on the gel holder cassettes for easy handling and main body for transfer (electrode assembly) comprised of red and black color parts and red and black electrodes to ensure proper orientation of the gel during the transfer. It also includes an efficient design which simplifies insertion and removal of the gel holder cassettes from the supporting body for transfer (electrode assembly). When the lid is open the power is off. The result of these features is an electrophoresis transfer system which is easy to use and safe to the end user. It produces excellent blotting results. The main body for transfer (electrode assembly) together with gel holder cassettes for electrophoresis transfer is compatible with the lid and external tank (buffer tank) of BT201. OVERVIEW The Wet/ Tank Blotting System consists of main body for transfer (electrode assembly), gel holder cassettes for electrophoresis transfer, supporting fiber sheet, lid, leads and external tank (buffer tank). Please refer to the figure below for part identification. Page 2 of 5

Gel holder cassette for electrophoresis transfer Lid Latch Supporting body for transfer (Electrode assembly) External tank TECHNICAL SPECIFICATIONS Dimensions of gel holder cassettes: 95x87 (mm); Max. voltage: 150 V; Max. power: 40W; Continuous working time: 24 hours; Electrodes are pure platinum (the purity quotient of the noble metal 99.95 The main body (electrode assembly) is macromolecule engineered plastics Gel holder cassette is polycarbonate Ambient temperature: 0 ~ 40 (32 104 F); Relative humidity 80%; Size (L XWX H): 150 x 100 x 140 (mm); Buffer volume: 400 ~ 450(ml); Weight: about 1.0 kg. OPERATION Safety tips Do not connect the Wet/ Tank Blotting System with electrophoresis power supply before starting the experiment. Electric current to the Wet/ Tank Blotting System, from the power supply, enters the unit through the lead and lid assembly, providing a safety interlock to the user. Electric current to the Wet/ Tank Blotting System is stopped when the lid is opened and removed. Please don t attempt to use the Wet/ Tank Blotting System without the lid. Always turn the electrophoresis power supply off before opening and removing the lid. 1. Cut six pieces of filter paper and one piece of membrane like PVDF membrane whose dimensions are the same as that of the gel. Please don t make the sizes of the filter paper and membrane bigger than that of the gel. Remember to wear gloves when you handle membranes to prevent contamination. Page 3 of 5

2. First, dip the PVDF membrane in 100% methanol for 10 seconds; Second, dip it in deionized water for 5 minutes; and then dip it in transferring buffer solution for 10 minutes. 3. Soak the filter paper in the transferring buffer solution for 10 minutes. 4. Assembling the gel holder cassettes: The order from cathode (black pore plate ) to anode (white pore plate) is as follows: black pore plate, supporting fiber sheet (for gel), 3 X filter papers, gel (cut off concentrated gel), membrane, 3 X filter papers, supporting fiber sheet (for gel), white pore plate. (Note: Air bubbles are not conductive, and therefore, interfere with protein transfer, you can get rid of air bubbles by gently rolling it out with glass tube). Then close the gel holder cassette, please be more careful not to move the gel and filter papers, and then lock the gel holder cassette with the white latch. Repeat in the other gel holder cassette. Then put them into the main body for transfer. Please note that the direction of the cathode and anode should be corresponding with those of the main body for transfer. Put the main body into the external tank (buffer tank), and fill the external tank with the buffer solution, then cover the lid. Connect the Wet/ Tank Blotting System with the power supply, set the voltage, electric current and then start running. Black pore plate (Cathode) Supporting fiber sheet (for gel) 3 X filter papers Gel (cut off concentrated gel) PVDF membrane 3 X filter papers Supporting fiber sheet (for gel) White pore plate (Anode). 5. The principle for determining electric current: If the dimension of the filter membrane is (7x6) cm, the constant electric current should be 7x6x2=84mA. Transferring period: within 2 hours. 6. After completing the experiment, disassemble the blotting system and remove the membrane for development. Clean the Wet/ Tank Blotting System, the supporting fiber sheets and the gel holder cassettes with laboratory detergent and rinse well with the deionized water. MAINTENANCE The product should be stored under the following conditions: Ambient temperature: - 40 degrees C ~ 55 degree C (-40 ~ 131 degrees F) Relative humidity: 93% No corrosive gas Not drafty Page 4 of 5

Clean the Wet/ Tank Blotting System after you finish an experiment. Use mild soap and warm water to clean the electrodes, gel holder cassettes and external tank. Be careful when you clean the main body. (electrode assembly). Avoid stretching or breaking the platinum wires. Avoid scratching or marring the platinum plates. Do not use abrasives or strong detergents to clean the Wet/ Tank Blotting System, and then wash the tank with deionized water. Air-dry it for the next use. Rinse the supporting fiber sheets with hot water and then in distilled or deionized water. Note: The main body of the Wet/ Tank Blotting System and some of its accessories are fragile. Do not drop or bump it. The platinum installed in the Wet/ Tank Blotting System is easy to break off. Please pay attention to this, especially when you clean the cell. TECHNICAL SUPPORT BT Lab Systems offers technical support for all of its products. If you have any questions about the product s use or, operation, please contact BT Lab Systems at the following: E-Mail: info@btlabsystems.com Page 5 of 5