Effective epilation of white and blond hair using combined radiofrequency and optical energy

Similar documents
Hair Removal Using a Combination of Electrical and Optical Energies Multiple Treatments Clinical Study Six Months Follow up

Laser Hair Removal: Results Of 2-Week Versus 6-Week Treatment Intervals

Evaluation of Safety and Efficacy of Variable Pulsed Light (VPL ) for the Treatment of Excess Hair in over 100 Volunteers

PLEASE SCROLL DOWN FOR ARTICLE

Study of Very Long-Pulsed (100 ms) High-Powered Diode Laser for Hair Reduction on All Skin Types

Light and Heat Energy (LHE ) Technology Review of a Novel Approach to Hair Removal

LASER HAIR REMOVAL: SCIENTIFIC PRINCIPLES AND PRACTICAL ASPECTS

Intense pulsed light for the treatment of hirsutism

The development of intense pulsed light photoepilation

Vider Itzhak MD2, Harth Yoram MD2,, Elman Monica MD, Gottfried Varda PhD3, Shemer Avner MD4, Beit Harofim

Simulated Consumer Use of a Battery-Powered, Hand-Held, Portable Diode Laser (810 nm) for Hair Removal: A Safety, Efficacy and Ease-of-Use Study

Evaluation of safety and efficacy of variable pulsed light in the treatment of unwanted hair in 77 volunteers

Tattoo Removal With an Electro-optic Q-Switched Nd:YAG Laser With Unique Pulse Dispersion COS DERM

STUDY. Comparison of Long-Pulsed Alexandrite and Nd:YAG Lasers, Individually and in Combination, for Leg Hair Reduction

Kufa Med. Journal Vol. 11. No.1

AESTHETIC PRECISION THE SAFEST AND MOST PRECISE LASER TREATMENT SOLUTION AVAILABLE FOR PIGMENTED LESIONS AND MULTI-COLOR TATTOO REMOVAL

Q-Plus Series. Taking care of people, our masterpieces. Q-Switched Laser Platform Tailored to Your Needs. Aesthetics

Scanner Optimized Efficacy (SOE) Hair Removal with the VSP Nd:YAG Lasers

FIBER OPTIC IRONING DIODE LASER EPILASION!

Nanosecond-domain Q-switched lasers have been

Client Training Guide

The skin is, in fact, protected by the capability that Epil kriolight. has, to keep the temperature constantly below 10 C, in order to

EFFECTS OF FLUENCE AND PULSE DURATION

A new generation of technology. For a new generation of patients. Elite MPX. Powered by MultiPlex

elase with Motif A New Picture in Pain Free Hair Removal Science. Results.Trust.

THE HIGH-TECH LABORATORY FOR HAIR REMOVAL EPILATION FACE BODY NOT FOR SALE IN THE U.S.A.

High power (600W) 808nm diode. Shall We THE Tango? Perfect Solution for Permanent Hair Removal

Springs of well-being

Lisa Chipps, MD, MS, FAAD Assistant Clinical Professor David Geffen School of Medicine at UCLA

Chapter 15: FotoFacial RF Pro Treatments

Pearl Fusion Technique

Current Standards in Light- Based Hair Reduction

Why treat pigmentation disorder in Asians? Softer and clearer skin is a key to looking younger and improved self satisfaction

GentleYAG Pro-U. Outstanding Results. Treating Multiple Indications. Upgradable. Science. Results.Trust.

MAXIMUM POWER TRIPLE MODE Q-SWITCHED, LP AND QLP ND:YAG LASER SYSTEM 3 PULSE DURATIONS 4 DISTINCTIVE WAVELENGTHS MULTIPLE INDICATIONS

The legacy behind Q-switched technology. MedLite C

lumenis one the power of performance

P NM DIODE LASER HAIR REMOVAL SYSTEM. Beijing Sanhe Beauty S & T Co., Ltd

MOTUS AY INNATE ABILITY. The All-In-One Simple Solution for Aesthetic Medicine and Dermatology

INNATE ABILITY MOTUS AX. The New Era of Hair Removal. Hair Removal Benign Pigmented Lesions

FIBER OPTIC IRONING DIODE LASER EPILATION!

ice Pretty. Cool. Virtually painless Proven safety record All skin types, even tanned skin Speed TM Applicator YAG Facial Tip ICE TM Tech

OBJECTIVE The objective was to quantify hair reduction in the axillae after treatment with a noninvasive microwave energy device.

Discovery PICO Series

Autumn 2008 Circulation 25,000 PRSRT STD U.S. POSTAGE PAID PERMIT NO LONG BEACH, CA

PLEASE SCROLL DOWN FOR ARTICLE

STUDY. Skin Rejuvenation Using Intense Pulsed Light. A Randomized Controlled Split-Face Trial With Blinded Response Evaluation

Science. Results. Trust.

IPL hair removal. Our Beauty Our Beurer. Clinically tested technology for maximum safety at home. Safe, fast and reliable.

REF Rev. 4

IPL hair removal. Our Beauty Our Beurer. Clinically tested technology for maximum safety at home. Safe, fast and reliable. Beautiful and wellgroomed

Be an artist of the new era.

OLIVE. Top Hair Removal Diode Laser System

Long-pulsed ruby laser-assisted hair removal in male-to-female transsexuals

Introducing the new LUMINA Laser and IPL platform

Bibliography of Studies & Peer Reviewed Papers

P-808. Hair removal- Faster, painless and better

a revolution in Q-Switched technology

Micro-Fractional & Whole Beam Technology Ablative Vaporization + Non-Ablative Coagulation Multiple Profitable Indications

Ruby laser-assisted hair removal reduces the coarseness of regrowing hairs: fallacy or fact?

LHE TM CLINICAL CASEBOOK. Hair Removal. Lighting the Future of Skin Care

SYNCHRO QS4 MEDICINE AND AESTHETICS SYNCHRO QS4. Maximum Results and Safety in Treating Multicolored Tattoos and Pigmented Lesions

Premium Q-Switched Nd:YAG

Q-Plus EVO. Q-Switched Laser Platform Tailored to Your Needs TECHNICAL SPECIFICATIONS RESULTS BEFORE / AFTER ACCESSORIES. Rx Only.

THE UNMATCHED STARS FOR PROFESSIONAL HAIR REMOVAL. Brochure not for the U.S.

MORE PRO THAN EVER 2000W. High power DIODE LASER PLATFORM GUARANTEED QUALITY. by cocoon medical

EXTREMELY POWERFUL AND COMPACT Q-SWITCH Nd:YAG LASER

David J. Goldberg (Ed.) Laser Dermatology

Successful treatment of periorbital rhytides with non-ablative technique using a simple radiosurgery device

Clinical Studies Confirm Superior Tattoo Clearance with PicoSure

The Perfect All-In-One Tattoo Removal Laser. Science Engineering Design Versatility Ease-of-Use Practicality

ExQ-Laser. Q-Switched Nd:YAG Laser Therapy Systems

Characterization of Laser Tattoo Removal Treatment Using Pulsed Photothermal Radiometry

Casnigo, 21 December 2010 OPERATIVE PROTOCOLS FOR IPL STARLITE

2/2/18 AVOIDING LASER COMPLICATIONS AND MAXIMIZING RESULTS. Relative Absorption GOLD THERAPY GENERAL CONSIDERATIONS GENERAL CONSIDERATIONS

THE COMPLETE SOLUTION FOR LASER HAIR REMOVAL

It is under the author s own responsibility

Infrared Technology for Skin Tightening A Hot Topic Utilizing Deep Dermal Heating

ice THE COMPLETE SOLUTION FOR LASER HAIR REMOVAL Pretty.Cool. Virtually painless Proven safety record All skin types, even tanned skin

Think Outside the Eye. Treat Skin and Eyelid Inflammation. *

Full Face & Body Skin Rejuvenation

Lux2940 Laser Advances Resurfacing. September/October 2007 Circulation 18,000

elaser Ultra-Fast & Powerful Aesthetic Solution Science. Results.Trust.

cellulite breakthrough Cellulite is a skin condition that appears body

Single-Treatment Skin Tightening By Radiofrequency and Long-Pulsed, 1064-nm Nd: YAG Laser Compared

CLINICAL EVALUATION OF REVIVOGEN TOPICAL FORMULA FOR TREATMENT OF MEN AND WOMEN WITH ANDROGENETIC ALOPECIA. A PILOT STUDY

HKS909. Diode laser. User&Training Manual

Laser Hair Reduction and Removal

RevLite SI. Q-Switched Laser Technology

THE UNMATCHED STARS FOR PROFESSIONAL HAIR REMOVAL. Brochure not for the U.S.

Micro-fractional Laser Skin Rejuvenation : Enhanced Outcomes with Novel Multi-Modality and Multi-Wavelength Treatment Paradigms

Can I remove the hair from my nipples? Absolutely, the flash represents no risk. Caution is advised on dark nipples.

NEW 3 Wavelengths and Resolve Fractional. The Complete Picosecond Platform

ASIAN SKIN: ROLE OF UVA IN HYPERPIGMENTATION AND PREVENTION

HAIR REMOVAL PHOTOREJUVENATION ACNE. Pulsed light that charms

Selectivity (but, how?)

Forename Surname... SOPRANO ICE SHR LASER CONSULTATION FORM

ComplexCity Q-Switched Nd:Yag

One platform, endless solutions

M22. All you need. All in one. LUMENIS.COM/AESTHETIC

Transcription:

J Cosmet Laser Ther 2004; 6: 27 31 # J Cosmet Laser Ther. All rights reserved ISSN 1476-4172 DOI: 10.1080/14764170410029022 27 Effective epilation of white and blond hair using combined radiofrequency and optical energy Neil S Sadick & Sharyn A Laughlin Authors: Neil S Sadick, MD, FACP, FAACS Clinical Professor of Dermatology Weill Medical College of Cornell University, New York, NY, USA Sharyn A Laughlin, MD Assistant Professor Department of Medicine, Division of Dermatology, University of Ottawa, Ottawa, Ontario, Canada Received 4 September 2003 Accepted 29 January 2004 Keywords: photoepilation ELOS hair removal white hair OBJECTIVE: The present study examined the long-term photoepilatory effect on blond and white hair of a combined intense pulsed light (680 980 nm) device with a bipolar radiofrequency component producing electrical current at a depth of 4 mm. MATERIALS AND METHODS: Thirty-six adult women with white and blond hair (skin phenotypes I V) were included in the study. The chin and upper lip were treated with four treatment sessions over 9 12 months with long-term follow-up performed at month 18 (6 months after the last treatment). The level of RF energy was 20 J/cm 3, while optical fluences varied from 24 to 30 J/cm 2. Hair counts and photographic evaluation of some sites were obtained at baseline, months 1, 3 and 5 and the final treatment session. RESULTS: An average hair removal of 48% was observed at month 18 (6 months following the final treatment session). A slightly higher photoepilatory efficiency was noted for blond hair (52%) versus white hair (44%) treatment sites. CONCLUSION: Combined radiofrequency and optical energy technology may produce effective photoepilation of blond and white hair phenotypes. J Cosmet Laser Ther 2004; 6: 27 31 Introduction There has been a continued evolution of photoepilatory technology, which has improved the long-term efficacy of laser and intense pulsed light (IPL) source hair removal. These technologies vary from short wavelength ruby (694 nm) and alexandrite (755 nm) sources, which target lighter hair/light skin phenotypes, to longer wavelength diodes (800 900 nm), IPL sources (500 1200 nm) and 1064 nm Nd:YAG technologies for darker hair/dark skin phenotypes. 1 35 However, the major refractory hair phenotype targeted by these technologies has been red, blond and white hair due to Correspondence: Neil S Sadick, MD, 772 Park Avenue, New York, NY 10021, USA. Tel: (z1) 212 772 7242; Email: nssderm@sadickdermatology.com the low intensity of target melanin chromophore in hair follicles exhibiting the aforementioned phenotypes. In this regard, the present study examined the long-term photoepilatory effect on blond and white hair of a new technology which combines an IPL source (680 980 nm), producing optical energies as high as 30 J/cm 2 with pulse durations up to 120 ms, with a bipolar radiofrequency device, which can generate radiofrequency (RF) energy as high as 20 J/cm 3 with a pulse duration as long as 120 ms designed to deliver RF electrical current at a depth of 4 mm, which can target deeplying follicles capable of producing long-term photoepilation. The theory behind this technology is to deliver a relatively low level of optical energy that is safe for all skin types while compensation for the lack of high laser light intensity is achieved by utilizing an additive energy that is not optical and does not require melanin as a target chromophore, but is selectively absorbed by the hair structure.

28 NS Sadick & SA Laughlin Materials and methods Thirty-six adult women with white and blond facial hair (aged 38 83 years; mean age 58 years) and skin phenotypes I V were included in the study (Table 1). Forty-one study sites were selected; 36 sites were on the chin and five sites were on the upper lip or moustache area. Twenty-one sites had blond hair while 20 exhibited white hair. 7 Patients were screened for endocrine disorders, recent Accutane 1 ingestion, recent sun exposure and scarring tendencies. Discontinuance of any epilatory or bleaching agents for 1 month was mandated prior to treatment. Patients with a history of previous laser, IPL or electrolysis treatment were excluded from the study. Informed consent from all participants was obtained and the body site to be treated was identified and photographed. No topical anesthetic agent was applied to treated body areas. The study group of patients received four treatment sessions over a period of 9 12 months and results were monitored 18 months after the first treatment or 6 months after the last treatment. The target area was shaved prior to treatment. Sequential digital photography using identical lighting, patient positioning and camera equipment (Fujifilm FinePix S2 Pro Digital SLR Camera, Tokyo, Japan) were obtained of all treatment sites at baseline and 1, 3 and 6 months after the last treatment. A thin layer of transparent gel was used for cooling and skin hydration. Light pressure was applied via the applicator to the treatment site in order to ensure good coupling of electrodes onto the skin surface. Contact cooling (x4 C) was provided via incorporation of a cooling chamber head in the treatment tip. The level of RF energy was set at 20 J/cm 3 in all study patients in a short pulse profile mode. The range of fluences used in the study protocol was 24 30 J/cm 2, depending upon skin phenotype. Test pulses were carried out on an area adjacent to the study site to determine the level of optical energy suitable for each patient. Pulses were placed in an adjacent minimally overlapping pattern over the entire study site. Multiple passes were carried out to a maximum of four passes unless there was persistent erythema that lasted more than a few minutes after each pass was completed. A baseline hair count was obtained manually by two independent observers marking terminal hairs under 66 magnification with an apochromatic optical loupe (Nikon) within a well-defined 3 cm 2 region. The following reference landmarks were utilized: lip (mid-philtrum), chin (midmandibular notch/mid-lower lip vermillion border) in order to achieve uniformity of sequential hair counts. Percentage hair reduction was defined as the average number of terminal hairs present at each defined time interval compared with the average number of terminal hairs at baseline. Hair counts were taken after each treatment session, at months 12 (following the last treatment) and 18 (6 months following the last treatment). Subjective patient reports and adverse effects were also recorded at each follow-up visit. A patient satisfaction scale was instituted at the last follow-up visit. The following scale was utilized: grade I no improvement; grade II mild improvement; grade III good improvement; grade IV excellent improvement. Results During the first week after the treatment, no significant hair reduction was observed. Maximum reduction in hair counts was observed at 6 8 weeks after each treatment. Hair density was decreased from treatment to treatment as noted by both patients and investigators. An average clearance of 48% was observed at month 18 (6 months following the final treatment session) (Figure 1). A slightly higher photoepilatory efficiency was noted for blond hair (52%) versus white hair (44%) treatment sites (Table 2). Upper lip and chin sites had comparable hair removal efficiency. Two patients had minimal response (less than Number of patients (n~36) Skin type I 2 II 16 III 12 IV 4 V 2 Anatomic location (n~41) Chin 36 Lip 5 Hair color Blond 21 (patient treatment sites) White 20 (patient treatment sites) Table 1 Demographic profile of the IPL/RF study population (36 patients). (A) Figure 1 (A) Before combined intense pulsed light (IPL)/radiofrequency (RF) white hair removal; (B) after combined IPL/RF white hair removal (four treatments; month 18 (6 months following last treatment); optical energy~26 J/cm 2 ; RF energy~20 J/cm 3 ). (B)

Epilation of white and blond hair 29 Hair type Month 12 Month 18 Blond hair 54% 52% White hair 48% 44% Table 2 Mean hair removal efficiency in the IPL/RF study population (four treatment sessions). 10% mean hair reduction). These two patients were older and had coarser whiter hairs. A total of 67% of patients graded their improvement as good or excellent, with the majority noting good or no improvement. Side effect profiles noted in this study were minimal. Transient hyperpigmentation requiring no therapy was noted in 8% of patients; 14% of patients had mild persistent erythema, which resolved within 24 hours. Results showed no significant dependence on skin color, as lighter and darker skin types responded similarly to treatment. Discussion Hair color is genetically determined by the presence of the black-brown pigment melanin and the yellow-red pigment pheomelanin. There is no simple arithmetic relationship between eumelanin/pheomelanin ratio and hair color, but the highest levels of eumelanin occurs in black hair and the highest levels of pheomelanin are appreciated with red hair. Eumelanin absorbs red or infrared light more than pheomelanin and it is the black-brown pigment granules in the matrix cells and hair shaft that provide the primary target chromophores. Thus, it is not surprising that previously reported studies confirm that photoepilation is less effective for red, blond and white hair, where diminution of melanocytes is associated with a lower amount of target chromophore. The results of this study indicate that combined RF and optical energy is an effective method of photoepilation for white and blond hair (Figure 2). It is generally accepted that white hair is unresponsive to light systems operating in the red and near infrared spectrum. The thermal damage time (TDT) varies with the diameter of the hair shaft and follicle, and the temperature of the hair shaft or matrix. 1 For medium to coarse hairs (50 125 microns) the TDT is 170 1000 ms. 1,2 The use of super-elongated pulses should theoretically be a more efficient way to produce pan-trichodestruction. 25 This mechanism of injury may be advantageous for treating blond or red hair where optical coupling to lower levels of black-brown granules is diminished. Few such technologies with super-long pulses are presently available for clinical usage. For white hair without pigment for optical coupling, even a super-long pulse is likely to be effective. With any pulse width, optical energy targets melanin and heating of the hair follicle occurs from the inside and proceeds outwards. In contrast, RF energy heats the hair follicle from the outside in and requires no chromophore. For gray or white hair where there is little or no melanin, the optical component of the electromagnetic pulse plays a minor role. It is hypothesized that there is non-specific preheating of the follicle acting as a macroscopic structure absorbing light. The preheating reduces the impedance and facilitates the concentration of RF current within the outer layers of the follicle. This progression of outward to inward heat transfer is likely responsible for the injury ensuing to the germinative area of the hair follicle which results in the hair removal efficiency that is clinically noted in this setting. This mechanism of injury should also theoretically provide effective epilation when the target chromophore is reduced, as with blond or red hair as shown in the present study. Other lasers being studied based on this concept include the super-long pulsed 810 nm diode laser. 36,37 (A) (B) Figure 2 (A) After intense pulsed light (IPL) white hair removal (optical energy~20 J/cm 2 ; no radiofrequency (RF) energy); (B) after combined IPL/RF white hair removal (optical energy~20 J/cm 2 ; RF energy~20 J/cm 3 ).

30 NS Sadick & SA Laughlin Other techniques used to target white hair include photodynamic therapy utilizing a photosensitizer such as 5 amino-levulinic acid, which also leads to non-chromophore targeting of pilosebaceous structures. 38 Melanin encapsulated liposomes (Meladyne) have also been studied as an exogenously introduced target for non-pigmented white, grey and light blond hair. Six-month follow-up studies utilizing the diode laser showed 75 100% hair reduction after three treatment sessions in 90% of treated patients. However, these results have never been substantiated by other investigators (Personal communication). The 48% hair removal efficiency observed 6 months following a third monthly treatment session reported in the present study population suggests that combined RF and optical energy offers a favorable alternative to this previously difficult to treat patient management subgroup. However, it should be noted that the epilatory efficiency of this technology, as demonstrated in the present study, is not as advantageous as pure laser sources utilized for the removal of darker hair skin phenotypes. The slightly higher photoepilatory efficiency of 52% noted for blond hair versus 44% noted for white hair might be expected based upon the potential synergistic effect of combined chromophore targeting and non-selective RF heating. The poorer response noted in two elderly patients with coarse white hair may be expected in view of the larger surface area of heating required for this phenotypic population. Conclusions Further comparative studies looking at the effect on hair RF alone versus light and RF are needed. Integrated RF and optical energy technology represent a new effective photoepilatory technology for the long-term removal of blond and white hair phenotypes. It is hypothesized that this technology in this patient population is based primarily on thermal damage induced by the RF component. Although results may not be quite as efficient as with chromophore-targeting primarily light-based technologies, it does offer a new approach to this previously refractory group of photoepilatory individuals. Acknowledgement Dr Sadick is a research consultant for Syneron. References 1. Altshuler G, Anderson R, Manstein D, et al. Extended theory of selective photothermolysis. Lasers Surg Med 2001; 29: 416 32. 2. Sadick NS, Shea CR, Burchette JL, Prieto VG. Highintensity flashlamp photoepilation: a clinical, histological and mechanistic study in human skin. Arch Dermatol 1999; 135: 668 76. 3. Anderson RR, Parrish JA. Selective photothermolysis: precise microsurgery by selective absorption of pulsed radiation. Science 1983; 220: 524 6. 4. Lask G, Elman, Slatkine M, et al. Laser-assisted hair removal by selective photothermolysis. Dermatol Surg 1997; 23: 737 9. 5. Dierickx CC, Grossman MC, Farinelli WA, et al. Permanent hair removal by normal-mode ruby laser. Arch Dermatol 2000; 134: 837 42. 6. Laughlin SA, Dudley DK. Long-term hair removal using a 3-millisecond alexandrite laser. J Cut Med Surg 2000; 4: 83 8. 7. Williams R, Havoonjian H, Isagholian K, et al. A clinical study of hair removal using the long-pulsed ruby laser. Dermatol Surg 2000; 24: 837 42. 8. Bencini P, Luci A, Galimberti M, Ferranti G. Long-term epilation with long-pulsed neodymium:yag laser. Dermatol Surg 1999; 25: 175 8. 9. Lorenz S, Brunnberg S, Landthaler M, Hohenleutner U. Hair removal with the long-pulsed Nd:YAG laser: a prospective study with one year follow-up. Lasers Surg Med 2002; 30: 127 34. 10. Herzberg J, Gusek W. Das Ergrauen Des Kopfhaares. Arch Klin Exp Dermatol 1970; 236: 368 84. 11. Lask G, Elman M, Noren P, et al. Hair removal with the Epitouch ruby laser a multicenter study. Lasers Surg Med 1997; 9 (suppl): 32. 12. McDaniel DH, Lord J, Ash K, et al. Laser hair removal: a review and report on the use of the long-pulsed alexandrite laser for hair reduction of the upper lip, leg, back, and bikini region. Dermatol Surg 1999; 25: 425 30. 13. Nanni CA, Alster TS. Long-pulsed alexandrite laserassisted hair removal at 5, 10, and 20 millisecond pulse durations. Lasers Surg Med 1999; 24: 332 7. 14. Dierickx CC, Grossman MC, Farinelli WA, et al. Hair removal by a pulsed, infrared laser system. Lasers Surg Med 2000; 10 (suppl): 42. 15. Dierickx CC, Grossman MC, Farinelli WA, et al. Comparison between a long-pulsed ruby laser and a pulsed infrared laser system for hair removal. Lasers Surg Med 2000; 10 (suppl): 42. 16. Grossman M, Dierickx C, Quintana A, et al. Removal of excess body hair with an 800 nm pulsed diode laser. Lasers Surg Med 2000; 10 (suppl): 42. 17. Weiss RA, Weiss MA, Marwaha S, Harrington A. Hair removal with a non-coherent filtered flashlamp intense pulsed light source. Lasers Surg Med 1999; 24: 128 32. 18. Nanni CA, Alster TS. A practical review of laser-assisted hair removal using the Q-switched Nd:YAG, long-pulsed ruby, and long-pulsed alexandrite lasers. Dermatol Surg 2000; 24: 1399 405. 19. Grossman MC, Dierickx C, Farinelli W, et al. Damage to hair follicle by normal mode ruby laser pulses. J Am Acad Dermatol 1996; 35: 889 94. 20. Gold MH, Bell MW, Foster TD, Street S. Long-term epilation using the Epilight broadband, intense pulsed light hair removal system. Dermatol Surg 1997; 23: 909 13. 21. Bencini PL, Luci A, Galimberti M, Ferranti G. Longterm epilation with long-pulsed Nd:YAG laser. Dermatol Surg 1999; 25: 175 8. 22. Nururkar V. The safety and efficacy of the long-pulsed alexandrite laser for hair removal in various skin types. Lasers Surg Med 1997; 10 (suppl): 189. 23. Ross EV, Ladin Z, Kreindel M, Dierickx C. Theoretical considerations in laser hair removal. Dermatol Clin 1999; 17: 333 55.

Epilation of white and blond hair 31 24. Orf RJ, Dierickx C. Laser hair removal. Semin Cutan Med Surg 2002; 21: 129 44. 25. Sadick NS. Laser and flashlamp photoepilation: a critical review of modern concepts bridging basic science and clinical applications. J Aesthetic Dermatol Cos Surg 1999; 1: 95 101. 26. Goldberg DJ. Unwanted hair evaluation and treatment with lasers and light pulse technology. Adv Dermatol 1999; 14: 115 39. 27. Bencini PL, Luci A, Galimberti M, et al. Long-term epilation with long-pulsed neodimium:yag laser Dermatol Surg 1999; 25: 175 8. 28. Alster TS, Bryan H, Williams CM. Long-pulsed Nd:YAG laser-assisted hair removal in pigmented skin: a clinical and histological evaluation. Arch Dermatol 2001; 137: 885 9. 29. Goldberg DJ, Silapunt S. Hair removal using a longpulsed Nd:YAG laser: comparison at fluences of 50, 80 and 100 J/cm 2. Dermatol Surg 2001; 27: 434 6. 30. Ross EV, Cooke LM, Timko AL, et al. Treatment of pseudofolliculitis barbae in skin types IV, V and VI with a long-pulsed neodymium:yttrium aluminum garnet laser. J Am Acad Dermatol 2002; 47: 263 70. 31. Chan HH, Ying SY, Ho WS, et al. An in vivo study comparing the efficacy and complications of diode laser and long-pulsed Nd:YAG laser in hair removal in Chinese patients. Dermatol Surg 2001; 27: 950 4. 32. Fournier N, Aghajan-Nouri N, Barneon G, et al. Hair removal with an Athos Nd:YAG 3.5 ms pulse laser: a 3-month clinical study. J Cutan Laser Ther 2000; 2: 125 30. 33. Rogachefsky AS, Becker K, Weiss G, et al. Evaluation of a long-pulsed Nd:YAG laser at different parameters: an analysis of both fluence and pulse duration. Dermatol Surg 2002; 28: 9342 96. 34. Tanzi EL, Alster TS. Long-pulsed 1064 nm Nd:YAG laser-assisted hair removal in all skin types. Dermatol Surg 2004; 30: 13 17. 35. Anvari B, Tanenbaum BS, Milner TE, et al. Selective cooling of biological tissues: application for thermally mediated therapeutic procedures. Phys Med Biol 1995; 40: 241 52. 36. Rogachefsky AS, Silapunt S, Goldberg DJ. Evaluation of a super long pulse 810-nm diode hair removal in suntanned individuals. J Cutan Laser Ther 2001; 3: 57 62. 37. Rogachefsky AS, Silapunt S, Goldberg DJ. Evaluation of a new super-long-pulsed 810 nm diode laser for the removal of unwanted hair: The concept of thermal damage time. Dermatol Surg 2002; 28: 410 14. 38. Dierickx G. Hair removal by lasers and intense pulsed light sources. Dermatol Clin 2002; 20: 135 46.