MeDioStar NeXT. - Innovation Made in Germany - MDS NeXT EN

Similar documents
THE HIGH-TECH LABORATORY FOR HAIR REMOVAL EPILATION FACE BODY NOT FOR SALE IN THE U.S.A.

THE UNMATCHED STARS FOR PROFESSIONAL HAIR REMOVAL. Brochure not for the U.S.

THE UNMATCHED STARS FOR PROFESSIONAL HAIR REMOVAL. Brochure not for the U.S.

LASER HAIR REMOVAL: SCIENTIFIC PRINCIPLES AND PRACTICAL ASPECTS

Q-Plus Series. Taking care of people, our masterpieces. Q-Switched Laser Platform Tailored to Your Needs. Aesthetics

AESTHETIC PRECISION THE SAFEST AND MOST PRECISE LASER TREATMENT SOLUTION AVAILABLE FOR PIGMENTED LESIONS AND MULTI-COLOR TATTOO REMOVAL

High power (600W) 808nm diode. Shall We THE Tango? Perfect Solution for Permanent Hair Removal

MAXIMUM POWER TRIPLE MODE Q-SWITCHED, LP AND QLP ND:YAG LASER SYSTEM 3 PULSE DURATIONS 4 DISTINCTIVE WAVELENGTHS MULTIPLE INDICATIONS

OLIVE. Top Hair Removal Diode Laser System

EXTREMELY POWERFUL AND COMPACT Q-SWITCH Nd:YAG LASER

GentleYAG Pro-U. Outstanding Results. Treating Multiple Indications. Upgradable. Science. Results.Trust.

One platform, endless solutions

P NM DIODE LASER HAIR REMOVAL SYSTEM. Beijing Sanhe Beauty S & T Co., Ltd

Q-Plus EVO. Q-Switched Laser Platform Tailored to Your Needs TECHNICAL SPECIFICATIONS RESULTS BEFORE / AFTER ACCESSORIES. Rx Only.

INNATE ABILITY MOTUS AX. The New Era of Hair Removal. Hair Removal Benign Pigmented Lesions

The legacy behind Q-switched technology. MedLite C

Micro-Fractional & Whole Beam Technology Ablative Vaporization + Non-Ablative Coagulation Multiple Profitable Indications

Introducing the new LUMINA Laser and IPL platform

Hair Removal Using a Combination of Electrical and Optical Energies Multiple Treatments Clinical Study Six Months Follow up

Portable IPL System. Principle and Application

NEW 3 Wavelengths and Resolve Fractional. The Complete Picosecond Platform

lumenis one the power of performance

SYNCHRO QS4 MEDICINE AND AESTHETICS SYNCHRO QS4. Maximum Results and Safety in Treating Multicolored Tattoos and Pigmented Lesions

P-808. Hair removal- Faster, painless and better

LUCID QY/Q-PTP. 1064nm/532nm Q-Switched Nd:YAG Laser

a revolution in Q-Switched technology

RevLite SI. Q-Switched Laser Technology

Discovery PICO Series

Premium Q-Switched Nd:YAG

Portable Picosecond Nd Yag Laser System

MOTUS AY INNATE ABILITY. The All-In-One Simple Solution for Aesthetic Medicine and Dermatology

What is Pico second laser?

M22. All you need. All in one. LUMENIS.COM/AESTHETIC

A new generation of technology. For a new generation of patients. Elite MPX. Powered by MultiPlex

What is Pico second laser?

Ellipse Plus Range - Operator s Manual

Science. Results. Trust.

M22. All you need. All in one. LUMENIS.COM/AESTHETIC

ALL IN ONE OMNIMAX S4. All the must haves in one system

Casnigo, 21 December 2010 OPERATIVE PROTOCOLS FOR IPL STARLITE

M22. All you need. All in one. AESTHETIC.LUMENIS.COM

FIBER OPTIC IRONING DIODE LASER EPILASION!

Be an artist of the new

Casnigo, 10 th of July, 2012 OPERATIVE PROTOCOLS FOR IPL APOLLO SUPERCHARGED

ExQ-Laser. Q-Switched Nd:YAG Laser Therapy Systems

Be an artist of the new

EFFECTS OF FLUENCE AND PULSE DURATION

FIBER OPTIC IRONING DIODE LASER EPILATION!

Q: Switch ND: YAG Laser Skin Care System Model SQ-2

Scanner Optimized Efficacy (SOE) Hair Removal with the VSP Nd:YAG Lasers

Be an artist of the new era.

Cutera. September/October 2017 INNOVATIVE SOLUTIONS. Optimizing New Laser Technologies in Aesthetic Practices

Nd:YAG. Multi-Treatment System. Hair Removal. Photo Rejuvenation. Tattoos & Pigmented Lesions

Springs of well-being

The skin is, in fact, protected by the capability that Epil kriolight. has, to keep the temperature constantly below 10 C, in order to

HYBRID FRACTIONAL LASER RESURFACING FOR SKIN AND VAGINAL MUCOSA. Robert Aycock, MD, FACS

Pearl Fusion Technique

The Perfect All-In-One Tattoo Removal Laser. Science Engineering Design Versatility Ease-of-Use Practicality

Think Outside the Eye. Treat Skin and Eyelid Inflammation. *

7 Function Anti Aging and Skin Rejuvenation Device Safe for all skin types

OPT SHR IPL. Skin & hair treatments. A must for patient to enjoy perfect skin without pain. Big spot size with 20HZ fast speed.

The new MÖ Laser Nd Yag 532nm & 1064nm uses the latest generation Pico technology. Powerful trillions of a seconds laser energy to grind the pigment

7 Function Anti Aging and Skin Rejuvenation Device Safe for all skin types

THE VENUS VIVA EXPERIENCE

PROFILE TM modular, multi-application aesthetic laser platform. The profile of precision.

Client Training Guide

ComplexCity Q-Switched Nd:Yag

elaser Ultra-Fast & Powerful Aesthetic Solution Science. Results.Trust.

T R A I N I N G M O D U L E IPL 1

Ellipse Light SPT + and I 2 PL +

PLEASE SCROLL DOWN FOR ARTICLE

Lux2940 Laser Advances Resurfacing. September/October 2007 Circulation 18,000

ice Pretty. Cool. Virtually painless Proven safety record All skin types, even tanned skin Speed TM Applicator YAG Facial Tip ICE TM Tech

THE COMPLETE SOLUTION FOR LASER HAIR REMOVAL

MORE PRO THAN EVER 2000W. High power DIODE LASER PLATFORM GUARANTEED QUALITY. by cocoon medical

ice THE COMPLETE SOLUTION FOR LASER HAIR REMOVAL Pretty.Cool. Virtually painless Proven safety record All skin types, even tanned skin

Selectivity (but, how?)

Anthélia technical data(4)

Light and Heat Energy (LHE ) Technology Review of a Novel Approach to Hair Removal

Full Face & Body Skin Rejuvenation

Laser Hair Removal: Results Of 2-Week Versus 6-Week Treatment Intervals

Studies Book MeDioStar NeXT

HKS909. Diode laser. User&Training Manual

An average of 6-10 treatments is recommended for best results.

We are where you are!

Eq uip m en t Cat alo gue

elase with Motif A New Picture in Pain Free Hair Removal Science. Results.Trust.

TREATMENT GUIDELINES. September 2012 D0592 Rev. B Cutera 3240 Bayshore Boulevard Brisbane California PH:

2/2/18 AVOIDING LASER COMPLICATIONS AND MAXIMIZING RESULTS. Relative Absorption GOLD THERAPY GENERAL CONSIDERATIONS GENERAL CONSIDERATIONS

IPL hair removal. Our Beauty Our Beurer. Clinically tested technology for maximum safety at home. Safe, fast and reliable.

Tattoo Removal With an Electro-optic Q-Switched Nd:YAG Laser With Unique Pulse Dispersion COS DERM

IPL hair removal. Our Beauty Our Beurer. Clinically tested technology for maximum safety at home. Safe, fast and reliable. Beautiful and wellgroomed

Ellipse MultiFlex + An innovative I 2 PL device and an outstanding Nd:YAG laser in one versatile platform the ultimate choice for vascular treatments.

a noticeable difference in tattoo removal

When everything works together perfectly, that s harmony. Speed Fast, Natural Results Globally-Recognized Brand

When everything works together perfectly, that s harmony.

HAIR REMOVAL PHOTOREJUVENATION ACNE. Pulsed light that charms

Chapter 15: FotoFacial RF Pro Treatments

Skin System. Vascular Blemish treatment system

Q-switched Nd:YAG Carbon Laser Facial Further treatment possible using your Tattoo Removal Laser

Transcription:

MeDioStar NeXT - Innovation Made in Germany -

Next Generation of High Power Diode Laser 1999 2005 2008 2011 MeDioStar HC MeDioStar XT/miXT MeDioStar Effect MeDioStar NeXT (with add. modules)

Specifications Laser: high power diode, class 4 Wavelength: Energy: Pulse width: Frequency: Display: 800 nm to 950nm maximum at 810nm for hair removal, maximum at 940nm for vascular treatments Up to 60 J Up to 400 ms Up to 12 Hz 8,4 LCD touch screen Fluence: STD: 44 J/cm 2, HP: 90 J/cm 2, VAS: 210 J/cm 2 Dimensions: 365 x 560 x 465 mm (w x d x h) Weight: 35 Kg (System), 300 g (Handpiece) MeDioStar NeXT with and without trolley Power Input: universal input power supply 100 240 VAC 50/60 Hz

Features Design Handpiece Beam Profile Skin Cooling Double Pulse Speed Display Device Modern, reliable laser technology Made in Germany Portable device, elegant design (optional trolley) Intuitive operation thanks to 8,4 Zoll touch screen Easy to use Before and after photos and videos at display

Features Design Handpiece Beam Profile Skin Cooling Double Pulse Speed Display Application High Fluence with large spots for effective treatments Fast treatment of large areas Homogeneous beam profile of the spots to minimize side effects Effective skin cooling intergrated in the handpiece with automatic control od the skin temperature for gentle and convenient treatment with high efficiancy Double pulse for additional safety No consumables

Features Design Handpiece Beam Profile Skin Cooling Double Pulse Speed Display Storage space for footswitch and power cord in trolley Easiest transportation on trolley or by hand Safe and quick release connection between the 2 modules Washable, removable rubber product placement area

Features Design Handpieces Beam Profile Skin Cooling Double Pulse Speed Display Specs of handpieces STD (standard): Spot size Fluence Frequency hair removal, acne, rejuvenation 14 x 10 mm², square shaped beam max. 44 J/cm² max. 4Hz, max. 12 Hz with SmoothPulse (dependent on Fluence) HP (high power): Spot size Fluence Frequency hair removal of finer hair (acne, rejuvenation) 6 x 8 mm², square shaped beam max. 90 J/cm² max. 4Hz, max. 12 Hz with SmoothPulse (dependent on Fluence) VAS (vascular): Spot size Fluence Frequency vascular treatments, lentigines 3 x 4 mm², square shaped beam max. 210 J/cm² max. 4 Hz

Features Design Handpieces Beam Profile Skin Cooling Double Pulse Speed Display MedioStar NeXT a perfect combination of 2 wavelenghts 810 nm: long term proved wavelength for hair removal, high absorption in Melanin, little absorption in oxyhemoglobine 940 nm: higher absorption in oxyhemoglobine (coagulation of blood vessels up to 2 mm of diameter, deeper penetration into skin, less discomfort on darker skin types The combination of both wavelength is most suitable for hair removal applications on all skin types Pure 940 nm vascular handpieces bring most efficious results on leg veins and facial vessels

Features Design Handpiece Beam Profile Skin Cooling Double Pulse Speed Display Homogenity of the laser spot Optimized profile generated by quartz fiber bundle (TAPER technology) Sapphire coated (to prevent in-burn of particles) Square shaped (no gaps between spots, no overlap) Most homogenious beam profiles Flat top profile same Fluence all over the spot (no hot spots ) Fiber bundle tapers for optimal light delivery No energy losses Beam profile Flat-Top Gaussian (NeXT) (other lasers) TAPER technology magnification of writing without distortion shows homogenity VS.

Features Design Handpiece Beam Profile Skin Cooling Double Pulse Speed Display Principle of Skin Cooling Contact skin cooling by cold metal probe Pre-cooling of epidermis (move handpiece in direction to cold metal probe) Aluminium has 8 times better cooling effect compared to Sapphire (used by others for skin cooling) Immediate readyness after switch - on Smallest volume Peltier elements in handpiece Heat Semiconductor Bismut-Tellurid Bi 2 Te 3 Silizium-Germanium SiGe Diode stack Laser tip Peltier elements Skin cooling Cold

Features Design Handpiece Beam Profile Skin Cooling Double Pulse Speed Display Safety by skin cooling Study by Fiskerstrand 2003: less side effects with MeDioStar compared to LightSheer Nemeth ASLMS 2004: 978 treatments (skin type I to VI), 5 transient hyperpigmentierungs = 0,5% o 31,3 C o 34,1 C Thermal image during treatment of a back (at the top: hip at the bottom: shoulder) Safe application, because of automatic control of cooling temperature Professional mode 35,2 C SmoothPulse mode O C Note: with same parameters higher temperature above bones (in this case: shoulder blade) compared to areas without bones caution above bones! Bones prevent the penetration of laser light / heat into the depth of the skin, more heat at epidermis! 40J/cm² - 2,1Hz - 1Pass 12J/cm² - 7,7Hz - 4 Passes : place of temperature measurement

Features Design Handpiece Beam Profile Skin Cooling DoublePulse Speed Display Safety by DoublePulse: Temp. Skin temperature DoublePulse Skin temperature single pulse Epidermis DoublePulse Epidermis single pulse Laser on time Safety thanks DoublePulse: rise in temperature is dependent on Melanin content of the hair and of the Epidermis. The cold metal probe of the handpiece cools especially the Epidermis.

Features Design Handpiece Beam Profile Skin Cooling DoublePulse Speed Display Fast treatments MeDioStar vs. MeDioStar NeXT Spot size (STD) + 13% Frequency at 30 J/cm² + 40% Frequency at 35 J/cm² + 60% Frequency at 40 J/cm² + 100 % Treatment time of a back: Profesional/Basic: about 5.5min (1 pass with 2.1Hz / 40J/cm²) SmoothPulse: about 7.5min (4 passes with 7.7Hz / 12J/cm²)

Features Design Handpiece Beam Profile Skin Cooling DoublePulse Speed Display Large colored, easy-to-use touch-screen Windows XP based Logically placed menu structure Touch screen pen Pre & post treatment picture library Video library Pre & post treatment suggestion The Asclepion Effect learn more about Asclepion

MedioStar NeXT applications hair removal ascular lesions acne skin rejuvenation skin tightening removal of pigmentations skin whitening a large applicator for all skin rejuvenation procedures is still under R&D

Indications For all areas (besides directly around the eyes) For all skin types (extra care with skin type V and VI) For all colours of hair (besides white/grey, light blond, red Pheomelanin)

HIGH ABSORPTION in (Eu)melanin: By absorption of the laser light the hair is heated and damages the cells in the surrounding, which are responsible for hair regrowth. (Cooling of Epidermis necessary, especially for dark skin, which also contains melanin!!) LOWER ABSORPTION in blood and water: The blood and the skin (which contains water) absorb a bit light only and is therefore not much heated. That s why the risc of side effects is low.

Anatomy of the Hair Skin structures, which are responsible for hair growth: Bulge: Germinative follicle cells of the outer root sheath Hair Bulb: Matrix cells contain Melanin BULGE HAIR BULB

MedioStar NeXT the workhorse for hair removal Selective light absorption in Melanin Convertion into heat in shaft and bulb Thermal damage of hair roots and all structure responsible for hair growth Leaving epidermis intact Coagulation of micro vessels feeding roots

Hair is sensitive to laser treatment in the anagen phase only Hair Growth Cycle In human beings the hair cycle is NOT synchronized different hair follicles are in different phases: Multiple treatments are necessary Duration of the phases is dependent on location: interval between treatments ca. 4 weeks for face ca. 6-8 weeks for body 1. Epidermis 2. Infundibulum 3. Sebaceous gland 4. M. arrector pili 5. Hair shaft 6, Matrix cells 7. Capilliary 8. Follicular papilla

Clinical results: E.-J. Fiskerstrand, Trondheim/Norway (LasersSurgMed 2003;32:399-404): 34 patients, skin type II III, 3 treatments, light brown to dark hair, upper lip + 3 patients Bikini line side by side comparison LightSheer (9x9) vs. MeDioStarPRO(12mm), Fluence 35J/cm² efficiency the same (after 3 trx reduction of 49% MeDioStar vs. 48% LightSheer) no pigment changes, no scars less erythema and burned hair with MeDioStar A.J. Nemeth, Clearwater/Florida (presentation at EADV 2004): 200 patients, 978 sessions in total Fluence 10 36J/cm², 12mm spot size Skin type I VI, 84% II III 3-8 trx ( 4,9) 64% hair reduction after 3rd treatment after 5 treatments (0,5%) transient hyperpigmentation N.S. Sadick, New York/USA (DermSurg 2003;29:30-34): 24 patients, skin type I IV, 3 trx Axilla, Bikini line, hair colour: light dark brown 70% clearing 6 months after 3rd treatment 1 transient hyperpigmentation lasting 2 weeks

T. Ilknur, Uni Izmir/Türkei (LasersMedScience 2010; Okt.): 31 patients, skin type II IV, Axilla comparison of biophysical skin properties before/after 1 treatment vs. untreated efficiency: 48% hair reduction 6 weeks after 1 treatment, statistical significant reduktion of hair thickness erythema index different up to 2 weeks after treatment no change of: Melanin index, water content of skin, ph-value, secretion of sebum A. Steps (2011): Comparison of MeDioStar NeXT to MeDioStar mixt 12 patients, skin type I III, Axilla MeDioStar NeXT: 49% hair reduction after 3 trx (17 91%) result of MeDioStar NeXT a bit better compared to MeDioStar mixt

BASIC-Mode/ For standard treatments easy and fast To set FLUENCE (energy density) and SPEED In this mode always double pulse with shortest possible pulse duration (automatically) Normally 1 pass per area and session PROFFESSIONAL-Mode/ For individual treatments To set FLUENCE, SPEED and TIME (pulse duration) In this mode you can choose between double pulse (more safe) and single pulse (more effective for thin hair) Normally 1 pass per area and session SMOOTHPULSE-Mode/ Fast, effectiv and more pleasant for large areas To set low FLUENCE and high SPEED (up to 12Hz and 12J/cm²) In this mode always single pulse with shortest possible pulse duration (automatically) Multiple passes per area and session are necessary!!

Clinical Results Axilla By courtesy of A. Nemeth, Florida

Clinical Results Upper lip By courtesy of A. Nemeth, Florida

Clinical Results Facial hair of a woman after 6 trx By courtesy of P. Wood, Bad Homburg, Germany

Clinical Results Back CAVE: never treat a tattoo!! (damages the tattoo and can cause scarring) By courtesy of A. Nemeth, Florida

Clinical Results Back By courtesy of P. Wood, Bad Homburg, Germany

Clinical Results Bikini line By courtesy of A. Nemeth, Florida

Clinical Results comparison After 3 trx MeDioStar mixt 35 J/cm 2 @ 1,5 Hz MeDioStar NeXT 35 J/cm 2 @ 1,5 Hz By courtesy of André Steps, stepbysteps, Jena, Germany

Clinical Results comparison MeDioStar NeXT SmoothPulse-Mode 10 J/cm 2 @ 20ms @ 9,4 Hz Controll Plazebo By courtesy of André Steps, stepbysteps, Jena, Germany

Skin reaction directly after treatment (end-point) Normal- redness highest level perifollicular edema (to see specially in case of thick, dark hair CAUTION: keep optics clean!) By courtesy of P. Steiner, Germany

Side effects directly after treatment upper line ok lower line dirt at optics (which is in contact with skin) By courtesy of P. Steiner, Germany

Indications Ectatic vessels with diameter ca. 0.5 2mm (e.g. medium size leg veins) Hemangiomas Venous Lake Spider Naevi Lymphangiomas Granuloma pyogenicum

HIGHER ABSORPTION in Blood: By absorption of the laser light the blood in the vessel is heated and damages the tunica intima (disappearing of vessel or is coagulated sometimes (slight darkening of the vessel). The damaged tissue is resorbed by the lymphatic system and this takes some time. That s why sometimes one sees the successful treated vessel for some weeks check the blood flow by pressure with finger.

Anatomy of the Blood Vessels KTP Dye Diode Nd:YAG nm 532 577/585 940 1064 Port wine stains Telangiectasia Haemangioma Spider naevi Venous lakes Fine reticular veins Large reticular veins

Clinical results V. Tsepkolenko, Odessa/Ukraine (2003): 106 patients, vessel size up to 3mm Fluence 80 160 J/cm², 6 mm spot size 75% of vessels disappeared, 20% clearly better, 4% better, 1% unsatisfying K. Kykalova, Prague/Czechia 24 patients, vessel size 1 up to 4mm Fluence 90-100 J/cm² (higher values used in the beginning, but same results with less side effects with lower Fluence and overlap up to 2 pulses at the same spot area) 2-5 treatments results up to 2mm: 70% disappearence, 2-3mm : 50%, 4mm: 30% with 3 trx A. Steps, Jena/Germany (2011): 21 patients comparison of MeDioStar NeXT to MeDioStar mixt shorter pulse duration with same Fluence possible less side effects with MeDioStar NeXT

Clinical Results Leg Veins - before and 3 months after 1 treatment, 6mm, 80-100 J/cm ², non-contact By courtesy of Dr. Paul Wood, Proderma, Bad Homburg, Germany

Clinical Results Telangiectasia - before and 6 weeks after, 90 J/cm 2, 60ms, 6mm, non-contact By courtesy of Dr. Paul Wood, Proderma, Bad Homburg, Germany

Clinical Results Spider Naevi - 90 J/cm 2, 60ms, 6mm, non-contact By courtesy of Dr. Paul Wood, Proderma, Bad Homburg, Germany

Clinical Results Venous lake - before and 3 months after 1 treatment, 6mm, 80J/cm ², 75ms, 3 pulses, non-contact By courtesy of Dr. Paul Wood, Proderma, Bad Homburg, Germany

Clinical Results Lymphangiom - before and 2 months after, 6mm, 90J/cm ², non-contact By courtesy of Dr. Paul Wood, Proderma, Bad Homburg, Germany

Clinical Results Angiofibrom - before and 3 months after, 6mm, 90 J/cm ², 75m,s non-contact By courtesy of Dr. Paul Wood, Proderma, Bad Homburg, Germany

Clinical Results Hämangiom (tuberous) - before and 6 weeks and 3 months after, 6mm, 90J/cm ² 75ms, non-contact By courtesy of Dr. Paul Wood, Proderma, Bad Homburg, Germany

Clinical Results comparison 2 weeks after 2 veins look like each other 120 J/cm 2 @100ms (MeDioStar mixt) By courtesy of André Steps, stepbysteps, Jena, Germany 120 J/cm 2 @ 75ms (nur beim MeDioStar NeXT) By courtesy of André Steps, stepbysteps, Jena, Germany

Skin reaction directly after treatment (end-point) 2 min. after 10 min. after By courtesy of André Steps, stepbysteps, Jena, Germany By courtesy of André Steps, stepbysteps, Jena, Germany

Indications Acne vulgaris Acne inversa Treatment procedure like Hair Removal but longer pulses (more general heating of skin), 3-4 passes 4-5 treatments with 1 week interval

RATHER HIGH ABSORPTION in Blood and Water: By absorption of the laser light the blood of the inflamed area as well as the water of the skin is heated and affects the infected sebaceous glands. Because of less specific absorption (vs. hair and medium size blood vessels) multiple passes are nessesary. CAUTION with treatments of male beart: In areas with hair it will be removed!!

Clinical Results of Acne Inversa Treatments C. Passos-Pereira (Dermaforum Sept. 2003): Results of treatments of Acne inversa 20 patients Clinical presentation: recurrent formation of abscess up to monthly surgery under general anesthetic Fluence 30 40 J/cm², 12 mm spot size, treatment like hair removal all patients respond to the treatment the treatment should be done best in the early stage (without scars) in case of advanced couse: clear improvement of the findings and of the general condition dispensation with primarily radical surgery restriction to minimal procedures, which improves the situation of the patient as a secondary finding reduction of odor formation Scientific study is running with 60 patients in Bochum, Germany

Clinical Results A: Before laser treatment (HS-score 15) B: After 7 laser treatments (HS-score 2) Acne inversa By courtesy of Falk Bechara, M.D., Head of Dermatologic Surgery Unit, Ruhr-University Bochum, Germany

Indikationen Haarentfernung Gefäße Akne Rejuvenation Clinical Results A: Before laser treatment (HS-score 14) B: After 7 laser treatments (HS-score 3) Acne inversa By courtesy of Falk G. Bechara, M.D., Head of Dermatologic Surgery Unit, Ruhr-University Bochum, Germany

Clinical Results Acne vulgaris - before and 2 weeks after, 25 J/cm 2, 150 ms, single pulse By courtesy of Taiwan

Clinical Results Acne vulgaris - before and 2 weeks after, 28 J/cm 2, 175 ms, single pulse By courtesy of Taiwan

Indications Improvement of fine wrinkles Improvement of pore size Improvement of texture Skin whitening Improvement of darker benign age spots Treatment procedure like Hair Removal but longer pulses (more general heating of skin), 3 passes 3 treatments with 1 month interval

Clinical Results Wrinkles, pore size, texture, spots Dr. Dai et al., Taipei/Taiwan: (2008) Objective measurement of improvement of skin quality after treatment for rejuvenation Fluence 30 40 J/cm², pulse duration 300 400ms, 12 mm spot size, 3 passes, 1 treatment measurement of wrinkles, pore size, texture and age spots in % before/after 1 treatment improvement of texture: 22-31%, wrinkles: 33-39%, pore size 10-19%, spots:15% Lentigines vascular spot, non-contact. no skin cooling before treatment S. McCoy, Adelaide/Australia: 12 patients with many lentigines Fluence 25 50 J/cm², spot size first 12 mm, change to 6mm (shorter pulse duration) result less dependent on Fluence, but on color of lentigines (the darker the better)

Results 980 nm histology before after Zone of denaturated collagen underneath epithelium Epithelium is intact

Reduction of pore sizes, skin whitening

150 ms, single impulse, 25 J/cm2, 14 days after treatment

pore size improvement (32 to 51), immediately after 1st treatment meassured with Canfield Visia system (100 equals best condition)

wrinkle improvement (60 to 99), immediately after 1st treatment meassured with Canfield Visia system (100 equals best condition)

skin texture improvement (29 to 51), immediately after 1st treatment meassured with Canfield Visia system (100 equals best condition)

Lentigines / seborrhoic Keratosis - before and 6 weeks after, 6mm, 35J/cm ² 20ms, non-contact By courtesy of Sue McCoy, Laser Skin and Vein Clinic, Adelaide, Australia

Lentigines - before 2 weeks 6 weeks after Parameter: 6mm, 30J/cm ² 17ms, non-contact By courtesy of Sue McCoy, Laser Skin and Vein Clinic, Adelaide, Australia