Testing Cold Protection According to EN ISO 20344: Is There Any Professional Footwear that Does Not Pass?

Similar documents
A Comparison of Two Methods of Determining Thermal Properties of Footwear

Development of Empirical Equations to Predict Sweating Skin Surface Temperature for Thermal Manikins in Warm Environments.

Interaction effects of radiation and convection measured by a thermal manikin wearing protective clothing with different radiant properties

The Use of Footwear Insulation Values Measured on a Thermal Foot Model

Published in: Proceedings of the 11th International Conference on Environmental Ergonomics

Clothing insulation From Wikipedia, the free encyclopedia

Testing Services for the Evaluation of. Fabric Systems, Clothing Systems, Sleeping Bag Systems, Bedding Systems, and Personal Cooling Systems (PCS)

A Comparative Introduction on Sweating Thermal Manikin Newton and Walter

The comparison of thermal properties of protective clothing using dry and sweating manikins

Parallel and Serial Methods of Calculating Thermal Insulation in European Manikin Standards

Prediction of Clothing Thermal Insulation and Moisture Vapour Resistance of the Clothed Body Walking in Wind

Research Article Artificial Neural Network Estimation of Thermal Insulation Value of Children s School Wear in Kuwait Classroom

Experimental Heated, Breathing and Sweating Manikins. Integrating radiant. Fatigue Lab constructs the. losses. military use. of human body heat

Heat Balance When Wearing Protective Clothing

Contact person:

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Tender Notice No. DGVCL/SP/10048/Ind. Safety Shoes, PVC Boot & Rain Coat. Item No. 1 : Specifications of Industrial Safety Shoes

The E ects of Wind and Human Movement on the Heat and Vapour Transfer Properties of Clothing

SCRUB SUITS VS CLEAN AIR SUITS A THERMAL PROPERTIES COMPARISON

Comfort of Clothing. Rajesh Mishra & Jiri Militky Technical University of Liberec Liberec, Czech Republic

The Use of 3D Anthropometric Data for Morphotype Analysis to Improve Fit and Grading Techniques The Results

Measurement Method for the Solar Absorptance of a Standing Clothed Human Body

Room Climate Standard. Thomas Wolf, CSES

FORCED VENTILATION OF PROTECTIVE GARMENTS FOR HOT INDUSTRIES. J.A. Gonzalez, L.G. Berglund, T.L. Endrusick*, M.A. Kolka

Defense Technical Information Center Compilation Part Notice

Simulation of perspiration in sweating fabric manikin-walter

CLI MATE PROTECTION SYSTE M S

Assessment of Hypothermia Blankets Using an Advanced Thermal Manikin John P. Rugh 1* and Khalid Barazanji 2

Impact of local clothing values on local skin temperature simulation

ISO INTERNATIONAL STANDARD

Storleksmärkning av kläder Del 3: Mått och intervall. Size designation of clothes Part 3: Measurements and intervals

The interaction of clothing. ventilation with dry and evaporative heat transfer of jackets: the effect of air and. vapor permeability

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Local air gap thickness model for realistic simulation of thermal effects in clothing

PPE/Foot protection/socks-knee pad

The basics of Flame retardant garments. Learn more about ISO 11612: Protection against heat and flame.

Effects of Working Experience of Patternmaker with a Designer on the Efficiency and Performance of Clothing Design

IGNITE The brand for modern durable safety footwear that will ignite your performance requirements.

8/2016. Protective clothing for firefighters TIGER MATRIX. 3rd category of Personal Protective Clothing

SBS5225 HVACR I Thermal Comfort. Ir. Dr. Sam C. M. Hui Faculty of Science and Technology

Improvement in Wear Characteristics of Electric Hair Clipper Blade Using High Hardness Material

Mongrel Boots Because what you do makes a difference to the boots you wear. How to order

Professor Alan Hedge, Cornell University 1/22

6. Leather Footwear. Fig. 1 Japan s leather footwear imports

Improving Men s Underwear Design by 3D Body Scanning Technology

Effects of Two Cooling Garments on Post-exercise Thermal Comfort of Female Subjects in the Heat

Applicability of the Thermal Manikin for Thermal Comfort Investigations

AR E W RK O W TO ASC

Thermal comfort sustained by cold protective clothing in Arctic open-pit mining a thermal manikin and questionnaire study

This document is a preview generated by EVS

Minimising formaldehyde exposure through substitution of resins

School of Health Sciences, University of Wollongong, Wollongong, Australia. Contact person:

Determination of the Air Gap Thickness underneath the Garment for Lower Body Using 3D Body Scanning

EVALUATION OF PHYSIOLOGICAL PROPERTIES OF THE FIRST LAYER GARMENT FOR SPORT APPAREL

Inspired by your comfort, driven by innovation.

INFRA- STRUCTURE C LOT H ING S Y STEM S F O R TH E TO U GHEST CH A LLEN G ES

Performance Study of Protective Clothing against Hot Water Splashes: from Bench Scale Test to Instrumented Manikin Test

The Role of Tests and Manikin in Defining Fabrics Thermal Characteristics

Calculation of Clothing Insulation by Serial and Parallel Methods: Effects on Clothing Choice by IREQ and Thermal Responses in the Cold

HITECH PERSONAL PROTECTIVE EQUIPMENTS

Improvement of Grease Leakage Prevention for Ball Bearings Due to Geometrical Change of Ribbon Cages

Effect of Hair Style on Human Physiological Responses in a Hot Environment

MEASUREMENT OF PHYSIOLOGICAL PROPERTIES OF MILITARY CLOTHING IN SIMULATION OF CLIMATIC CONDITIONS IN SELECTED AREAS OF THE WORLD

This document is a preview generated by EVS

PPE Information Sheet Protective Clothing for the Body

This document is a preview generated by EVS

An evaluation of the thermal protective clothing used by six Australian fire brigades

12 FOOTWEAR. 120

* Nara Women's University, Nara, Japan Nofer Institute of Occupational Medicine, Lo&, Poland

FOOTWEAR DRAFT ETHIOPIAN STANDARDS FOR PUBLIC COMMENT

AS/NZS :2011. High visibility safety garments AS/NZS :2011. Part 1: Garments for high risk applications. Australian/New Zealand Standard

Supporting Material for TIA 1105 (2112)

RUB & RAIN CATALOGUE AW 17 RUB & RAIN AW 17

SAFETY FOOTWEAR. Quality PROTECTIVE FOOTWEAR FOR. comfort AND DURABILITY in THE WORKPLACE

THE NEW REFERENCE TECHNOLOGY FOR SLIDING SYSTEMS

Mongrel Boots Because what you do makes a difference to the boots you wear. How to order

Press information. All wrapped up. Warm outer layers for cold days. 22-Jan EN

UC Berkeley Indoor Environmental Quality (IEQ)

Fabrics. WL Gore & Associates An enterprise organized around four divisions. Medical Products. Industrial. Products. Electronic.

POWER TRANSFORMERS MVA kv. ISO 9001: Żychlin, ul. Narutowicza 70 ISO 14001:2004 PN-N-18001:

Prosafe International Pvt. Ltd.

Effect of hair characteristics on vaginal temperature under hot and humid conditions in an Angus-Brahman multibreed herd.

Tough clothing for professionals

FOOT PROTECTION. lowtronix.com

Laboratory assessment of cold weather clothing

OPTIMAL BOOT ENGINEERING

EMERGENCY PHONE: or (651) (24 hours)

Biomedical Research 2018; Special Issue: ISSN X Study on the effect of professional sports clothing on sports physiology.

CONTOURED GARMENTS FOR WOMEN WITH BIG BUSTS

Evaluation of the performance of elastic band used for ready made garment manufacturing

Snowplant Collection Workbook

Fabric Inspection Guideline

REDISCOVERED. REDESIGNED. REBUILT.

Comparison of Women s Sizes from SizeUSA and ASTM D Sizing Standard with Focus on the Potential for Mass Customization

Manikin Design: A Case Study of Formula SAE Design Competition

IMPROVING WORKING LIVES

ISO INTERNATIONAL STANDARD. Protective clothing for protection against chemicals Classification, labelling and performance requirements

Special textiles are the ideal solution for effective protection against harmful UV radiation. Hohenstein Institute

INDUSTRIAL SAFETY WORKWEAR

MEN S LEATHER WORK BOOTS. Welted Rigger. Welted Work Boot KWRG01 KGEO02 SAFETY FOOTWEAR. Men s Sizes: Whole 7-14 / Half

EMERGENCY PHONE: or (651) (24 hours)

Transcription:

Ann. Occup. Hyg., Vol. 53, No. 1, pp. 63 68, 2009 Ó The Author 2008. Published by Oxford University Press on behalf of the British Occupational Hygiene Society doi:10.1093/annhyg/men074 Testing Cold Protection According to EN ISO 20344: Is There Any Professional Footwear that Does Not Pass? KALEV KUKLANE 1 *, SATORU UENO 2, SHIN-ICHI SAWADA 2 and INGVAR HOLMÉR 1 1 The Thermal Environment Laboratory, Division of Ergonomics and Aerosol Technology, Department of Design Sciences, Faculty of Engineering, Lund University, SE-22100 Lund, Sweden; 2 International Center for Research Promotion and Informatics, Japanese National Institute of Occupational Safety and Health, 214-8585 Kawasaki, Japan Received 14 March 2008; in final form 27 August 2008; published online 14 November 2008 The present Comité Européen de Normalisation (CEN) and International Organization for Standardization (ISO) standards for safety, protective and occupational footwear EN ISO 20344 20347 classify footwear as cold protective by a pass/fail test where the limits are set for an allowed 10 C temperature drop inside the footwear during 30 min at a temperature gradient of 40 C. It is questionable if a simple pass/fail test of this kind provides approved footwear that really protects the feet from cooling in exposures ranging from temperatures at 118 C to as low as or even lower than 250 C. This study selected for testing some professional footwear that could certainly not be considered as cold protective. Some footwear that could be used in cold was selected with as low insulation as the not cold-intended footwear. Also, a boot intended for cold was selected to be tested according to a modified standard at a temperature gradient of 70 C. The footwear selection was based on insulation measurements with a thermal foot model. All footwear did pass the test. Although it is clear for the user that a sandal, a mesh shoe or a thin textile shoe is not cold protective, it is not as clear that an item of safety footwear, that has as low insulation as those mentioned above, could be classified as cold protective according to the present standards. Because of this, the user might have a deceptive feeling of safety and may be exposed to higher risks. As practically all professional footwear may pass this cold test, then the method/requirements should be radically changed or such a test should be removed from the standards. Keywords: cold-protective footwear; occupational safety; standard test method INTRODUCTION *Author to whom correspondence should be addressed. Tel: þ46-46-222-7833; fax þ46-46-222-4431; e-mail: kalev.kuklane@design.lth.se The temperature of the foot in dry conditions is determined by the balance between heat input from circulating blood and heat losses to the environment. Heat losses are three-dimensional and take place through sole, uppers and leg by conduction, radiation and convection and through openings by convection. The ability of footwear to affect this heat transfer is defined by its thermal insulation. This property can be measured on humans (Kuklane et al., 1999a) or on a thermal foot model (Kuklane and Holmér, 1998). The thermal insulation value allows a prediction of how well the footwear protects in different cold exposures (Kuklane, 2004). The present European (CEN) and international (ISO) standards for safety, protective and occupational footwear EN ISO 20345 20347 (2004) classify footwear as cold protective by a pass/fail criterion. A 10 C temperature drop inside the footwear during 30 min at an initial suggested temperature gradient of 40 C (EN ISO 20344, 2004) is allowed. The temperature change is measured with a sensor fixed onto the insole in the forepart of the footwear just above the point where the sole is in direct contact with the support platen. By this method, it is not possible to determine whether certain footwear that has passed the test will actually protect under certain cold conditions. A previous study (Kuklane et al., 1999b) expressed strong doubts 63

64 K. Kuklane et al. whether a simple pass/fail test is correct for thermal testing. For example, the same footwear that helps to keep a good thermal comfort at 10 C when walking may be too cold for standing at the same temperature or walking at 25 Candtoowarmtobeusedatþ10 C. It was also remarked that eventually any safety, protective or occupational footwear might pass the test. In that study, footwear for cool and cold conditions was studied. If the cold is defined just as a temperature below þ18 Cthen all those footwear would certainly be cold protective. During the past years, the standards have been reviewed; however, the test on cold protection has got only some cosmetic improvement, mainly directed towards making the testing procedure simpler and less time consuming. For example, the conditioning for 7 days was removed as well as the demand for specific conditioning humidity, and the temperature range was moved from þ20 2to 20 2toþ23 2to 17 2 C for conditioning and testing, respectively. The same conditioning temperature applies also for heat transfer media consisting of 4 kg of 5 mm ball bearings that are poured into footwear before testing. The aim of this paper is to demonstrate that the standard test method (EN ISO 20344, 2004) and the requirements (EN ISO 20345 20347, 2004) are neither relevant nor valid for testing and classification of cold-protective footwear. METHODS The footwear was chosen from 19 types of professional footwear that were measured with a thermal foot model for and in cooperation with Japanese National Institute of Occupational Safety and Health. The thermal foot model test results were presented elsewhere (Ueno et al., 2008). The footwear was tested in order to provide thermal insulation values as a basis for recommendation of footwear for different thermal environments (Kuklane, 2004). It is generally recognized that the thermal foot method is the most relevant and valid method to measure thermal insulation of whole products. The method is similar to that used for whole clothing (EN 342, 2004; EN ISO 15831, 2004) and gloves/mittens (EN 511, 2006). For this study, five types of footwear were selected that should not provide protection against cold due to their construction and low insulation value (Fig. 1, Table 1). Also, a cold-protective boot intended for cold (C) was included. With the exception of this one, none of the tested footwear had higher insulation than ordinary summer/indoor shoes according to thermal foot model tests. Tests were carried out according to EN ISO 20344. The standard allows increasing the upper height with a collar if the uppers are not enough high to support the heat transfer media. This was done with ordinary printer paper for footwear R and S. For footwear S, the printer paper was also taped in front of other openings (Fig. 2). The test procedure was the following. The temperature sensors were fixed in the footwear (Fig. 3) onto the insole, for measuring the temperature in the forepart of the footwear directly above the Fig. 1. Footwear. Table 1. Footwear from Cofra, Italy (C), and Midori Anzen, Japan (H, F, R, B and S), and the effective insulation values (I cle, m 2 CW 1 ), i.e. air layer insulation subtracted without considering clothing area factor (f cl ), of all foot zones (toes, mid-sole, heel and dorsal foot) and the mid-sole only Code Model Color Upper material Sole material Weight (g) Size I cle, foot I cle, sole C Thermic Orange SRC Yellow Low density polyurethane (PU) Middle density PU and nitrile rubber 1274 42/9 0.202 0.235 H SU561N White Synthesized leather Two layers of new 332 26.5 0.114 0.225 foaming polyurethane F V3901N Red Cow chrome leather One layer of synthesized 737 26.5 0.106 0.219 rubber R SU403 White Synthesized leather/mesh Two layers of new foaming 288 26.5 0.105 0.218 polyurethane B W2000 Black Polyvinyl chloride Polyvinyl chloride 839 26.5 0.090 0.181 S Elepass Lady WB Black Synthesized leather One layer of foaming polyurethane During thermal foot tests, a thin sock (I cle 5 0.013 m 2 CW 1 ) was used in combination with the footwear. 261 26.5 0.057 0.261

Testing of cold protective footwear 65 Fig. 2. Footwear S with openings covered. Fig. 3. Placement of the sensors (footwear H). area where the sole contacts the support platen (Fig. 4), as specified by the section 5.13 Determination of the insulation against cold of the standard (EN ISO 20344, 2004). One of the sensors was a thermocouple fixed to a copper disc as specified by the standard. The data from this sensor was recorded with a logger Testo 177-T4 (accuracy 0.3 C). As this sensor showed a specific temperature increase (0.5 C) after lifting the footwear into the cold chamber (Fig. 5), then an extra sensor was added. It was an external precision sensor connected to a modular signal recorder (MSR) 145W logger (accuracy 0.1 C, Glattbrugg, Switzerland). The test pieces and heat transfer medium consisting of 4000 g of 5 mm diameter stainless steel balls were conditioned at 23.1 0.0 C until the temperature of the insole stayed constant (allowed by standard 23 2 C). Then the steel balls were poured into the footwear. The footwear stayed at the conditioning temperature for 30 min more in order to assure the constant temperature values. The air velocity during conditioning was 0.36 0.03 m s 1. After the temperature of the outsole became constant at 23.1 0.0 C, the test piece was placed into the cold chamber with an environmental temperature of 16.9 0.1 C (allowed by standard 17 2 C) on a support platen of copper for at least 40 min. During the modified tests with boot C, the temperature gradient was set to 70 C. This was achieved by keeping the conditioning temperature the same as in standard, i.e. þ23 C, while the testing temperature was lowered to 47 C instead of standard s 17 C. During the tests, the footwear collar was sealed with an insulating cover with an elongated hole that corresponded to the cover suggested by the standard (Fig. 4). The copper plate had the dimensions of 500 300 5 mm and in this way made the conditions more tough by adding more mass (thermal inertia) and contact area with cold air compared to standard plate (350 150 5 mm). In all cases, the air velocity in the test chamber at the ankle level Fig. 4. Placement of the footwear (F) in a cold chamber with an arrow pointing to sensor location. stayed low at 0.15 0.04 m s 1 (not specified in the standard). The temperature decrease during whole exposure was recorded and temperature decrease within 30 min was calculated. If the temperature drop did not exceed 10 C (EN ISO 20345 20347, 2004) then footwear passed the test and could be classified as cold-protective footwear. The standard (EN ISO 20344, 2004) does not define exactly the start point of the recording; however, it may be understood that after sealing the insulating cover the measurements could be started. In order to make the test tougher and exclude the initial effect of footwear mass (thermal inertia) and consider only relatively linear cooling curve, an additional start criterion was defined at a point where insole temperature passed 23 C for determining the temperature drop in footwear within 30 min. The temperature drop was considered to decide pass or fail according to the standard. The criteria for starting points are shown in Fig. 5. A real start criterion starts when the footwear is placed in the test position and the chamber was closed. This period includes thermal changes related to the footwear thermal inertia and development of

66 K. Kuklane et al. Fig. 5. Temperature profiles in a test (boot B) with start criteria for recording of the 30-min temperature drop: (1) real start footwear has been placed and the chamber closed, (2) the MSR sole sensor value drops,23 C and (3) the disc sensor (thermocouple) value drops,23 C. Initial temperature drop in MSR-ambient sensor depends on that it was moved together with footwear from warm to cold chamber. stable heat loss related to temperature gradient. The start time was checked after the experimenter had left the cold chamber and it applied for both sensors. The second start criterion was based on the last MSR sole sensor value which was.23 C. This period involved less initial cooling phase of the footwear. As the sensors behaved slightly differently, then the third start criterion was based on the last disc sensor value that was.23 C. This period was not in practice dependent on any of the initial cooling phase of the footwear. The initial temperature drop in MSR ambient sensor depended on the move together with footwear from warm to cold chamber. The mean ambient air temperature value (Table 2) was acquired based on the 10th to 30th minutes of each start criterion. During a pretest, the ambient sensor was placed in cold chamber during conditioning beforehand. The effect of entering the chamber to place the footwear raised the ambient air temperature values by,1 C for,2 min only, i.e. such a change could not affect the thermal mass of the support platen, and calculation of temperature change based on the start criteria 2 and 3 could not be affected by that change at all. Each item of footwear, except C, was tested twice (the standard requires testing two samples). RESULTS AND DISCUSSION The temperature decreases measured by EN ISO 20344 are ranked in Table 2. The calculation criteria for temperature drop ranked the footwear generally identically with just small differences, except for criterion 3 where initial mass related slower cooling was excluded. All footwear passed the test regardless of the start criterion. Thus, all tested footwear is approved and can be CE-marked (Comité Européen) as cold-protective footwear. As the test is a pass/fail test and does not indicate how well the footwear protects against cold, there is no recommendation to the user in what temperature they can be used. It should be remembered here that the thermal insulation values (Table 1) of the tested footwear, except for C, were similar to those of shoes for temperate weather. Footwear C is intended for cold protection. Its insulation value (I cle, foot ) was almost twice as high or higher than the other footwear. It also passed a modified standard test at a higher temperature gradient (70 C) with good margins (Table 2). When looking at insulation values of the lowinsulation footwear (Table 1), then F, H and R were very similar for both whole foot and sole insulation. B had a lower insulation for both foot and sole, and S had the lowest total foot insulation (S was measured on thermal foot model without paper covering the openings), while the sole insulation was the highest. As the temperature drop was measured at the sole and the openings of S were closed by paper, then this footwear managed the test very well compared to B, R and H. However, most probably it would have passed the test also if a thin sock or just mesh would have been used to keep the steel balls at place as the mesh shoe (R) did pass the test. On the other hand, if testing with

Table 2. Conditioning and test temperatures, mean gradients and footwear ranked by temperature drop ( C) for each start criterion (see Fig. 5): (1) real start footwear has been placed and the chamber closed (both sensors), (2) the last MSR sole sensor value is.23 C and (3) the last disc sensor (thermocouple) value is.23 C Code Conditioning Mean test air Initial Temperature drop after 30 min for start criteria temperature temperature gradient 1 (Disc) 1 (MSR) 2 (MSR 23) 3 (Disc 23) F 23.0 16.8 39.7 5.6 0.0 6.2 0.7 7.4 0.4 8.5 0.3 S 23.0 17.0 40.1 6.6 0.3 7.2 0.0 7.8 0.2 7.7 0.3 B 23.1 16.8 39.9 7.3 0.5 7.1 0.2 8.1 0.4 9.5 0.1 R 23.1 17.0 40.2 8.8 0.4 8.5 a 8.8 a 9.3 0.9 H 23.0 16.9 39.9 9.5 0.0 9.4 0.0 9.6 0.1 9.6 0.3 C b 22.9 47.8 70.7 6.9 7.3 a Sensor error in one test, data lost. b Just one test carried out. Testing of cold protective footwear 67 wind, e.g..0.40 m s 1, then both these shoes (R and S) might have failed. However, the EN ISO 20344 (2004) does not define air velocity during testing. The test at lower temperature gradient that is still allowed by the standard according to conditioning (23 2 C) and test conditions ( 17 2 C),e.g.the gradient of 37 C at21.5 0.5 and 15.5 0.5 C for conditioning and testing, respectively (Kuklane et al., 1999b), would allow even less insulated footwear than used in this study to pass the test and be classified as cold-protective footwear. Comparing temperature drop ranking (Table 2) with insulation values (Table 1), the values seem not to be correlated as they were in an earlier study (Kuklane et al., 1999b). Such a difference may be related to the fact that in the previous study all footwear were calf high boots with airtight outer layer and their insulation differed considerably. In this study, the footwear had a different grade of open structures in the footwear uppers and apparently different air permeability of footwear surface material but also relatively similar thermal insulation. The main issue, however, is not that a sandal (S), a shoe with mesh uppers (R) or a thin textile shoe for clean rooms (H) did pass the test. With such footwear, it is clear for everybody that these are not for protection against cold. The problem is that the footwear (B and F) that has as low insulation as S, R and H may be classified as cold protective and in this way giving the user a deceptive safety feeling and exposing him/her to higher risks. Footwear F is in the catalogue classified as heat-protective footwear. As insulation is non-directional, then it protects both against cold and heat. It might be questionable if F actually does protect the user and raises a question if it was tested according to heat insulation test of the same standard (section 5.12, EN ISO 20344, 2004) that exploits the same test principles. All tested low insulation footwear are more or less suitable for temperatures down to þ10 C, but certainly not below 10 C. Even if it is possible to improve the standard method with extra ranking criteria, one is still not able to estimate without a major study how these ranks fit with the combination of: (i) ambient and ground temperature, (ii) different activity levels of the users and (iii) the use of different types of socks and insocks. Big organizations may have a chance to test a few samples in the field before purchase of their equipment, but smaller enterprises would need to rely on standard testing and proper labelling. A field study in dairy farms (Kuklane et al., 2001) at ambient temperatures generally between 10 and 20 C showed that most of the farmers used rubber boots type B. The toe temperatures shifted 20 C. In some cases, even the average toe temperature stayed,20 C and could reach even down to 13 C. Such a chronic cold exposure may cause various types of health trouble later in life. The thermal insulation of the footwear is the most important property determining heat exchange in the cold. However, under certain conditions, the moisture handling properties of the footwear become important as well. Sweating may take place, in particular during higher activities. Very little moisture and vapour pass through the relatively thick material. Ventilation of the tight-fitting shoe via the leg opening takes place but is limited (Kuklane et al., 2000). Socks and soles may be used as moisture absorbers. The best solution to the problem, however, is to stay dry and this is much of a disciplinary and behavioural question. Proper routines to take care of the feet and footwear with information on the insulation value would give both military and industrial leaders what is required to choose and recommend the required protection level of footwear and the best combination of footwear sock system for their subordinates. CONCLUSIONS All tested footwear passed the test, i.e. most professional footwear would pass the test. It is clear for the user that a sandal, a mesh shoe and a thin textile shoe are not cold protective. The problem is that the professional footwear, that has as low insulation as those mentioned above, may be classified as

68 K. Kuklane et al. cold protective according to the present EN ISO 20344 20347 (2004). In this way, the user might be provided with a deceptive safety feeling and may be exposed to higher risks. The test results give no information to the wearer how well the footwear protects against cold. The present test is neither relevant nor valid. Testing the footwear according to this test is a waste of resources for both test houses and manufacturers. Therefore, the test method in its present form should be withdrawn and replaced with a more discriminating, relevant and valid method. FUNDING Lund University; Japanese National Institute of Occupational Safety and Health. Acknowledgements The authors thank Cofra, Italy, for allowing publishing the results of a special test. REFERENCES EN 342. (2004) Protective clothing ensembles and garments for protection against cold. Brussels, Belgium: European Committee for Standardization. EN 511. (2006) Protective gloves against cold. Brussels, Belgium: European Committee for Standardization. EN ISO 15831. (2004) Clothing physiological effects measurement of thermal insulation by means of a thermal manikin. Brussels, Belgium: European Committee for Standardization. EN ISO 20344. (2004) Personal protective equipment test methods for footwear. Brussels, Belgium: European Committee for Standardization. EN ISO 20345. (2004) Personal protective equipment safety footwear. Brussels, Belgium: European Committee for Standardization. EN ISO20346. (2004) Personal protective equipment protective footwear. Brussels, Belgium: European Committee for Standardization. EN ISO 20347. (2004) Personal protective equipment occupational footwear. Brussels, Belgium: European Committee for Standardization. Kuklane K. (2004) The use of footwear insulation values measured on a thermal foot model. Int J Occup Saf Ergon; 10: 79 86. Kuklane K, Holmér I. (1998) Effect of sweating on insulation of footwear. Int J Occup Saf Ergon; 4: 123 36. Kuklane K, Afanasieva R, Burmistrova O et al. (1999a) Determination of heat loss from the feet and insulation of the footwear. Int J Occup Saf Ergon; 5: 465 76. Kuklane K, Holmér I, Afanasieva R. (1999b) A comparison of two methods of determining thermal properties of footwear. Int J Occup Saf Ergon; 5: 477 84. Kuklane K, Holmér I, Giesbrecht G. (2000) One week sweating simulation test with a thermal foot model. In: Nilsson HO and Holmér I, (eds) 3IMM, the third international meeting on thermal manikin testing. 106 13Arbete och Hälsa 2000:4. Stockholm, Sweden: National Institute for Working Life. Kuklane K, Gavhed D, Fredriksson K. (2001) A field study in dairy farms: thermal condition of feet. Int J Ind Ergon; 27: 367 73. Ueno S, Kuklane K, Holmer I et al. (2008) Thermal resistance of occupational footwear used in Japan. Local Organizing Committee of the 18 th International Congress on Biometeorology, 22 26 September 2008, Tokyo, Japan.