SureCast Handcast System For preparation of handcast mini gels for use with the Mini Gel Tank and XCell Surelock systems

Similar documents
StainEase Gel Staining Tray

KERATIN CONTAMINATION

Mini Blot Module. For transfer of proteins using the Mini Gel Tank USER GUIDE. Online Specials. Catalog Number B1000

E-Blotter Operation. Technical Bulletin E-03 MATERIAL PROCEDURE

Western Blotting Systems CAT NO:EPS-B0015 & EPS-B0016

Vertical Gel Electrophoresis System. Instruction Manual

Hoefer SE615 and SE675

Optiblot SDS-PAGE Gel

EXERCISE 8C - Lab Procedures

Instruction Manual OmniPAGE Vertical Electrophoresis Units. Catalogue Numbers

Instruction Manual OmniPAGE Vertical Electrophoresis Units. Catalogue Numbers

Optiblot Non-Reducing Electrophoresis Kit

Wet/ Tank Blotting System

CosmoPage Dual Run & Blot System

Optiblot SDS-PAGE Gel

Comparative Proteomics Kit II: Western Blot Module Quick Guide

Optiblot SDS-PAGE Gel

iblot 2 Dry Blotting System

iblot Dry Blotting System

Glycoprotein Staining Kit

WHAT IS GEL ELECTROPHORESIS?

ROBOT PIN TOOL CLEANING AND LIQUID SAMPLE TRANSFER

Dual Cool Run & Blot Mini-Vertical PAGE System (DCX-700)

Protein Electrophoresis

Copper Stain & Destain Kit for Electrophoresis Instruction Manual. Catalog Number

TEO ClearPAGE Precast Gel Running Instructions for SDS PAGE and DNA/Native Gels. Table of Contents

Hair Clipper. User's manual

Lenis Needle-free Safety Syringe Device User Manual

i-twin Trim Dual Blade Rechargeable Trimmer

Become a Clarisonic Preferred Customer SONIC SKIN CLEANSING. One Speed. One-Year Warranty

VisPRO 5 Minutes Protein Stain Kit


Student Performance Guide. Student Performance Guide. Student Performance Guide. Student Performance Guide. LESSON 3-3 Bleeding Time

B-SERIES CONVERSION INSTRUCTIONS

3D Printing Guide: MakerBot Replicator 2X

28145_HKVAC_IB 9/1/05 10:14 AM Page 1 VACUUM TRIM. Use and Care Guide HKVAC-2000

OPERATING MANUAL Model S2 #

SHAVER 7300 S7370. Always here to help you. Rechargeable Cordless Tripleheader Shaver.

SHAVER 7500 S7720. Always here to help you. Rechargeable Cordless Tripleheader Shaver.

POP ACRYLIC NAILS. user guide

CORIAN SOLID SURFACE CARE AND MAINTENANCE FOR FACILITY MANAGERS

Student Manual SO 3 N N N + Blue 1 Yellow 5 N N. Yellow 6 Red 40. Fig. 3. Reference dyes used in this experiment. - O 3 S - OOC

Procedure 30 Collecting A Blood Specimen Using The Vacuum-Tube System. Procedure 31 Collecting A Blood Specimen Using A Needle And Syringe

Sterilization A Training Module

Vacuum 5 in 1 Grooming Kit

Acne Treatment USER GUIDE. Includes important safety information. Read all instructions before using device.

AT850. Always here to help you. Rechargeable Cordless/Cord Tripleheader Shaver. Register your product and get support at

Nose and Ear Hair Trimmer

EnglisH introduction general description (Fig. 1) Preparing for use Charging

Exfoliate, Enhance and Smooth. User Manual & Warranty Information Model ST257

BODY & BIKINI KIT 2 YEAR WARRANTY WPG4020AU USE & CARE MANUAL. To register your product go to PLEASE READ PRIOR TO USE

QuickCut Clipper. 10,000 prize draw. Register online for HC4250. EXTRA year guarantee FREE rewards gallery

HAIRCUT KIT. 2 YEAR WARRANTY HC1090 Series USE & CARE MANUAL. To register your product go to PLEASE READ PRIOR TO USE

Student Manual SO 3 N N N + Blue 1 Yellow 5 N N. Yellow 6 Red 40. Fig. 3. Reference dyes used in this experiment. - O 3 S - OOC

This bulletin gives specific instructions for application of Avery Dennison translucent film to recommended flexible-face signage material.

GMT180WTPBCSC BEARD/MUSTACHE TRIMMER

Phenion FT Skin Model Histological processing Paraffin sections

MUSTACHE GROWING A BEARD AND. the manufacturer-to trim your beard and. For the best trimming results, your beard

Series 7. Series7. trimmer. Series 7. off. sensitive. intensive. clean. high. low. empty. reset

EasyClean 500 series

CoolTec. CT6cc CT5cc CT4cc CT4s CT3cc CT2cc CT2s. Type 5676

DOMINIQUE DUTSCHER SAS. Hoefer SE 400/SE 410. user manual. the Sturdier vertical slab gel electrophoresis units SE 400/SE 410

Philips Sonicare 2 series Plaque control plus

PrecisionCut Hair Clipper

Series7. Series 7. trimmer. Series 7. off. sensitive. intensive. clean. high. low. empty. reset

EasyClean 500 series

7310XL 7315XL 7325XL 7340XL 7345XL 7349XL 7350XL. Rechargeable Tripleheader Cordless/Cord Razor

Ultimate Body & Bikini Kit

Exfoliate & Cleanse. Instructions for Use & Warranty Information Model ST102

Rechargeable Tripleheader Cordless/Cord Razor 8240XL 8250XL 8251XL. Model 8240XL. Register your product and get support at

Charging base. Trimming head (30mm) on charging stand. Main body unit. On/Off switch. Indicated light. Connecting jack Connecting jack

UNIVERSITY OF SOUTHERN MAINE Office of Research Integrity & Outreach

Prosonic BS washable clean. trimmer. off. eco. normal. intensive. high. auto select. low. empty. reset

ULTIMATE HAIRCUT KIT 2 YEAR WARRANTY HC5005AU USE & CARE MANUAL PLEASE READ PRIOR TO USE

Series7. Series 7. trimmer. Series cc. off. sensitive. intensive. clean. high. low. empty. reset

8270XL. Rechargeable Tripleheader Cordless/Cord Razor. Register your product and get support at

Preparing the Gel Box and Pouring the Agarose Gel

10,000 prize draw. Register online for HC5800 HC5600 HC5400. EXTRA year guarantee FREE rewards gallery

BIO Lab 12: Bacteria. Materials Required:

Wrinkle Reducer. Attachment USER MANUAL

Standard Laboratory Practice for Consumer Applied Pet Stain and Odor Removal Chemical Evaluation on Pile Yarn Floor Coverings

ProCutiGen Vegan Thermal Shield Efficacy Data

2.6-1 SCIENCE EXPERIMENTS ON FILE Revised Edition. Cloud Chamber

Table 6: Detailed Infection Prevention and Control Procedures for Tattooing and Micropigmentation. Use During Tattooing

DOWSIL 9040 Silicone Elastomer Blend

Instructions For Use PRALUENT (PRAHL-u-ent) (alirocumab) Injection, for Subcutaneous Injection Single-Dose Pre-Filled Pen (75 mg/ml)

Page 1 of 7. Hand-Held High Frequency C9220T

Figure A. Figure B To prevent premature activation of the needle safety guard, do not touch the NEEDLE GUARD ACTIVATION CLIPS at any time during use.

TECHNICAL INFORMATION

Prisma & Film Staining Workshop. Application Specialist Mea Pelkonen

SW6700. Tripleheader shaver. & Lucasfilm Ltd. Disney

Ember 3D Printer. Created by Ruiz Brothers. Last updated on :00:07 PM EDT

HAIRCUT KIT. 2 YEAR WARRANTY HC2000 Series USE & CARE MANUAL. To register your product go to PLEASE READ PRIOR TO USE

Series cc. Series 7. Type Series 7. trimmer. Series cc. off. sensitive. intensive. clean. high. low. empty.

PREPARATION OF BLOOD FILMS FOR MALARIA DETECTION

REVOLUTION M SERIES MANUAL & PARTS GUIDE

Prosonic TM. 790 cc. Type trimmer. off. eco. normal. clean. intensive. high. auto select. low. empty. reset

POWER TOOL HAIR CUT KIT

shave care HP 6337/6336 rechargeable cordless wet/dry razors instructions for use

Series 5. Series cc. Type Series 7. trimmer. Series 7. off. 760 cc. sensitive. intensive. clean. reset

Transcription:

Handcast System For preparation of handcast mini gels for use with the Mini Gel Tank and XCell Surelock systems USER GUIDE Catalog Numbers HC1000, HC1000S, and HC1000SR Publication Number MAN0014073 Revision B.0 For Research Use Only. Not for use in diagnostic procedures.

For Research Use Only. Not for use in diagnostic procedures. Information in this document is subject to change without notice. DISCLAIMER TO THE EXTENT ALLOWED BY LAW, LIFE TECHNOLOGIES AND/OR ITS AFFILIATE(S) WILL NOT BE LIABLE FOR SPECIAL, INCIDENTAL, INDIRECT, PUNITIVE, MULTIPLE OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH OR ARISING FROM THIS DOCUMENT, INCLUDING YOUR USE OF IT. IMPORTANT LICENSING INFORMATION These products may be covered by one or more Limited Use Label Licenses. By use of these products, you accept the terms and conditions of all applicable Limited Use Label Licenses. CORPORATE ENTITY Life Technologies Carlsbad, CA 92008 USA Toll Free in USA 1.800.955.6288 TRADEMARKS 2016 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. Handcast System User Guide 1

Contents Product Information... 3 Product description... 3 Kit contents... 3 Description of parts... 4 Product specifications... 6 Gel selection... 6 Methods... 7 Before starting... 7 Procedure... 7 Gel electrophoresis... 11 Removing the gel from the glass plate assembly... 12 Maintenance... 13 Appendix A... 14 Troubleshooting... 14 Appendix B... 15 Related products... 15 Technical support... 16 2 Handcast System User Guide

Product description Product Information The Invitrogen Handcast Station is used to cast your own polyacrylamide gels. Instructions are provided for casting gels using reagents, but reagents can be substituted with equivalent materials if following alternative recipies for resolving gel and stacking gel solutions. Gels prepared with this protocol can be used in the XCell SureLock Mini-Cell or Mini Gel Tank. Use buffers and run conditions designated for Novex Tris-glycine gels. Kit contents The components included with the Handcast System (Cat. no. HC1000) are listed below. See Description of parts (page 4) for more details. Components Catalog Number Storage Gel Handcast Station Glass Plates Sealing Pads 10-well Multi-Use Tool 12-well Multi-Use Tool 15-well Multi-Use Tool Gel Spacer Gel Combs, variety pack Reagents Stacking Buffer (1L), 2-pack Stacking Buffer (2.5L), 5-pack Resolving Buffer (1L), 2-pack Resolving Buffer (2.5L), 5-pack APS Acrylamide Solution - 40% TEMED HC1000 HC1001 HC1002 HC1010 HC1012 HC1015 HC1003 HC1005 HC2112 HC2115 HC2212 HC2215 HC2005 HC2040 HC2006 Room temperature Room temperature Handcast System User Guide 3

Description of parts Introduction The parts of the Handcast System are described in the following section. See page 14 for ordering information. Handcast Station The Handcast Station consists of a plastic base in which glass plates and a gel spacer are held in position with a cam plate to allow casting of polyacrylamide gels. Cam Plate Sealing Pad Handle Handcast Station Base Heel Glass Plates Glass Plates consist of a front plate and a back plate. The front plate has a notch at the top of the plate for placement of the gel comb when casting gels. The back plate has a slot at the bottom, and a printed fill line to indicate the level to which resolving gel solution is poured when casting gels. When assembled, the lettering on the back plate should be readable, indicating that the plate is in the correct orientation. Notch Fill Line Slot Front Plate Back Plate 4 Handcast System User Guide

Sealing Pad The Sealing Pad is attached to the cam plate, and ensures that the slot in the back plate is sealed against leakage when pouring the resolving gel. The pad also holds the glass plates firmly in place for casting. Gel Spacer The Gel Spacer is a 1 mm thick silicone spacer that is placed between front and back Glass Plates when casting gels. The spacer is matched with the gel combs to cast 1 mm thick gels. Gel Combs The Gel Combs are plastic combs with 1 mm thick teeth, used to cast 10-well, 12-well, and 15-well gels. 10-well 12-well 15-well Multi-use Tool The Multi-use Tool can be used for several purposes: Gel loading guide for 10-well, 12-well, or 15-well gels Gel cassette opening tool Gel cutting tool Gel spatula 10-well 12-well 15-well Reagents The solution are provided to pour high quality gels, and can be stored at room temperature. Resolving Buffer Stacking Buffer Acrylamide Solution 40% APS TEMED Handcast System User Guide 5

Product specifications Handcast Station specifications Dimensions: Material: Glass Plate Size: 10 10 10 cm Plastic 10 cm 10.5 cm The Handcast Station is compatible with alcohols, but not compatible with chlorinated hydrocarbons (e.g., chloroform), aromatic hydrocarbons (e.g., toluene, benzene) or acetone. Gel selection General guidelines Choose the polyacrylamide percentage and type of well for your application based upon the expected molecular weight of your protein of interest and the volume of your sample. Resolve large molecules with low percentage gels and small molecules with high percentage gels. If the molecular weight of the molecule is unknown, or the sample contains a wide range of molecules, use a mid-range percentage gel. Recommended loading volumes The maximum recommended loading volumes and protein load per band are provided in the table below. Note: To ensure the highest band resolution, do not exceed the maximum load volume. Well Types Gel Thickness Maximum Recommended Volume Maximum Protein Load Per Band* 1.0 mm 25 µl 0.5 µg/band 1.0 mm 20 µl 0.5 µg/band 1.0 mm 15 µl 0.5 µg/band * Protein load values are for purified proteins that are western blotted subsequent to electrophoresis. For direct Coomassie staining (e.g. SimplyBlue Safestain), protein loads should be increased 10-fold. 6 Handcast System User Guide

Before starting Methods Prepare resolving and stacking buffers Prepare 10% APS (fresh) If required, prepare resolving and stacking buffer solutions according to the instructions printed on the packaging. 1. Dissolve the contents of one Resolving Buffer pack in deionized water to a final volume of 500 ml. 2. Dissolve the contents of one Stacking Buffer pack in deionized water to a final volume of 500 ml. The reconstituted buffers can be stored at room temperature for at least 3 months. To ensure proper polymerization of Gels, prepare fresh 10% APS before casting gels. Dissolve 0.3 g of APS in 3 ml of deionized water. Procedure Set up the Handcast Station 1 2 3 4 Notch Slot 1. Set the handcast station on a level surface. 2. Place the back glass plate on the benchtop so that the print is in the correct orientation for reading. 3. Place the silicone spacer on the back plate, and align it to the slot. 4. Place the front glass plate on the stack with the notch on top. 5 6 7 Notch Slot 5. Hold the glass plate assembly so that all the outer edges are flush and place it in the handcast station. The bottom edge of the glass plate assembly should make contact with the base of the handcast station. 6. Hold the glass plate assembly to prevent shifting, and close the handle to secure the glass plates in the handcast station. 7. Verify that the parts are properly aligned before pouring the gel. Improper assembly can result in leakage of acrylamide solution. Handcast System User Guide 7

Prepare resolving gel solution WARNING: Before handling, read all applicable Safety Data Sheets (SDS) at thermofisher.com/support 1. Prepare resolving gel solution according to the volumes in the following table. The volumes provided in the table are for a single gel. Scale volumes proportionally based on the number of gels to be cast. Note: Solutions do not require degassing. Solution Polyacrylamide % 4% 6% 8% 10% 12% 14% 16% 18% 20% Acrylamide (40%) Resolving Buffer 0.8 ml 1.2 ml 1.6 ml 2.0 ml 2.4 ml 2.8 ml 3.3 ml 3.6 ml 4.0 ml 2.0 ml 2.0 ml 2.0 ml 2.0 ml 2.0 ml 2.0 ml 2.0 ml 2.0 ml 2.0 ml Distilled water 5.1 ml 4.7 ml 4.3 ml 3.9 ml 3.5 ml 3.1 ml 2.7 ml 2.3 ml 1.9 ml 10% APS 80 μl 80 μl 80 μl 80 μl 80 μl 80 μl 80 μl 80 μl 80 μl Total 8 ml 8 ml 8 ml 8 ml 8 ml 8 ml 8 ml 8 ml 8 ml 2. Add 8 μl of TEMED for every 8 ml of resolving gel solution. Mix well (but gently) and proceed immediately to Pour resolving gel, page 9. 8 Handcast System User Guide

Pour resolving gel 1 2 3 Heel 1. Tilt the handcast station to recline on the heel. 2. Add resolving gel solution to the gap between the glass plates until the solution reaches the level of the fill line. 3. (Optional) Carefully overlay the resolving gel solution with 0.5 1.0 ml of watersaturated 2-butanol, degassed water, or isopropanol. 4 5 6 4. Set the handcast station back to the upright position. 5. Allow the resolving gel to polymerize (5 10 min). The interface becomes more distinct as the gel polymerizes. 6. Verify polymerization by examining left over acrylamide in the tube. 7 8 7. If overlay was used, pour off the overlay solution and rinse with water (dispose of butanol waste in the appropriate manner for organic chemicals). 8. Wick out any remaining liquid with a piece of blotting paper, and proceed to Prepare stacking gel solution, page 10. Handcast System User Guide 9

Prepare stacking gel solution 1. Prepare stacking gel solution according to the following table. The volumes provided in the table are for a single gel. Scale volumes proportionally based on the number of gels to be cast. Note: Solutions do not require degassing. Solution 4% Acrylamide (40%) Stacking Buffer Distilled water 0.30 ml 0.75 ml 1.92 ml 10% APS 30 μl Total 3 ml 2. Add 3 μl of TEMED for every 3 ml of resolving gel solution. Mix well and proceed immediately to Pour stacking gel. Pour stacking gel 1 2 3 Heel 1. Tilt the handcast station to recline on the heel. 2. Add the stacking gel solution until it reaches the upper edge of the front glass plate. 3. Insert the comb slowly by starting at one end and sliding it between the glass plates until both ends are in place. 4 5 6 4. Set the handcast station back to the upright position. 5. Allow the stacking gel to polymerize (~10 minutes). 6. Verify polymerization by examining left over acrylamide in the tube. Remove plate from casting station Release the clamp and remove the glass plate assembly containing the polymerized gel. The gel can be used immediately, or wrapped in a damp paper towel and stored at 4 C for future use. 10 Handcast System User Guide

Gel electrophoresis Insert Gel 1. Use a pipette to gently wash the wells with 1X running buffer. Invert the gel and shake to remove buffer. Repeat twice. Fill the sample wells with running buffer. 2. Place the Gel into a XCell SureLock Mini-Cell or Mini Gel Tank according to the instructions provided in their respective manuals. Load wells Use the Multi-use Tool to visualize the location of the wells when loading samples. 1 2 1. Slide the Multi-use Tool onto the glass plate. 2. Load samples and markers into wells. Run conditions Gels prepared with this protocol can be used in the XCell SureLock Mini-Cell or Mini Gel Tank. Use buffers and run conditions designated for Novex Tris-glycine gels. Run gels as described in the following table: Running Buffer Constant Voltage Run Time* Tris-Glycine Running Buffer 125 V 80 140 min * Run time varies depending upon the percentage of the gel, the type of gel tank, and the power supply used for electrophoresis. Handcast System User Guide 11

Removing the gel from the glass plate assembly Open the glass plate assembly 1 2 3 1. Slide the Multi-use Tool into the gap between the front and back glass plates. 2. Use the Multi-use Tool to pry the glass plates apart. 3. Separate the two pieces of glass. Remove the wells and foot of the gel 1 2 1. Use the blade of the Multi-use Tool to cut off the portions of the gel that form the wells. 2. Use the blade of the Multi-use Tool to cut off the portion of gel in the slot. Make the cut just above the slot. Alternately, see Remove the gel from the glass plate, page 13. Remove the gel from the front plate using the Multi-use Tool 1 2 3 1. Slide the Multi-use Tool under the gel, and gently separate the gel from the glass plate. 2. Carefully lift the gel from the glass plate, while holding one edge against the Multiuse Tool to prevent the gel from sliding off. 3. Transfer the gel into a tray of water. 4. Proceed to gel staining or other downstream application (e.g., western transfer). 12 Handcast System User Guide

(Optional) Remove the gel from the glass plate 1 3 2 3 1. Wet your glove with water to prevent the gel from sticking to the glove. 2. Hold the glass plate over a tray containing water. 3. Insert the blade of the Multiuse Tool through the slot, and push gently to release the gel from the glass plate. 4. Allow the gel to slide from the glass plate, and onto your hand. 5. Lower the gel into the tray of water. 6. Proceed to gel staining or other downstream application (e.g. western transfer). Maintenance General guidelines After casting gels, dispose of the waste materials in an appropriate manner. o Polymerized polyacrylamide is not considered hazardous and can be disposed of in regular trash. o Waste butanol used for overlaying the resolving gel, must be disposed of as an organic solvent. Rinse and wipe the handcast station to remove any residual liquids and solidified polyacrylamide. Clean the surface of the glass plates by rinsing and rubbing gently under a water stream. Do not use harsh detergents or solvents. Use the blade of the Multi-use Tool to scrape out any residual gel material stuck in the slot of the back plate. Rinse and wipe the Multi-use Tool to remove any residual liquids and residual gel material. Sealing Pads may wear out and need to be replaced. See page 15 for ordering information. Handcast System User Guide 13

Appendix A Troubleshooting The following table provides some solutions to possible problems that may be encountered when casting polyacrylamide gels. Observation Cause Solution Resolving or stacking gel polymerizes too quickly Resolving or stacking gel does not polymerize Resolving gel solution leaking from glass plate assembly Improper addition of TEMED Incorrect amount of APS used in gel solution Problem with 10% APS solution TEMED not added to resolving or stacking gel solution Glass plate assembly not properly seated in handcast station Damage to silicone spacer Make sure that TEMED is added to resolving or stacking gel solutions just before pouring. Make sure that 10% APS is used to prepare gel solutions Ensure that fresh 10% APS is used to prepare resolving and stacking gel solutions. Make sure that TEMED is added to resolving or stacking gel solution just before pouring. Ensure that glass plates and silicone spacer are properly aligned and placed in the handcast station with the bottom edge of the glass plate assembly in contact with the base of the handcast station (page 7). Replace damaged spacer. See page 15 for ordering information. Irregular surface between resolving gel and stacking gel Wells not properly formed Sealing pad on cam plate worn out Residual gel material stuck on glass plates, spacer, or handcast station Solution not level in glass plate assembly after being poured Insufficient stacking gel solution added to glass plate assembly Bubbles trapped between teeth of gel combs Replace worn out sealing pad. See page 15 for ordering information. Clean plates, spacer, and handcast station after every use. See page 13 for maintenance guidelines. Rock the handcast stand side-to-side after adding resolving gel solution until the surface becomes level. Add overlay solution on top of resolving gel solution (page 9). Ensure that stacking gel solution is filled to the upper edge of the front glass plate. Make sure that bubbles do not become trapped between the teeth of the gel comb during insertion. 14 Handcast System User Guide

Appendix B Related products Additional products Many of the components of the Handcast System, as well as additional reagents that may be used for electrophoresis of proteins are available separately from ThermoFisher Scientific. Ordering information is provided below. For details, visit thermofisher.com or call Technical Support (page 15). Apparatus Quantity Cat. no. Mini Gel Tank 1 unit A25977 XCell SureLock Mini-Cell 1 unit EI0001 PowerEase 90W Power Supply 1 PowerEase 300W Power Supply 1 PS0090 PS0091 PS0092 PS0300 PS0301 PS0302 Replacement Parts Quantity Cat. no. Glass Plates 2 pair HC1001 Sealing Pads 2 pads HC1002 Gel Spacers 10 spacers HC1003 10-well Multi-Use Tool 1 HC1010 12-well Multi-Use Tool 1 HC1012 15-well Multi-Use Tool 1 HC1015 Gel Runner Tank 1 B4478641 Cassette Clamp (Left) 1 B4478593 Cassette Clamp (Right) 1 B4478592 Mini Gel Tank Lid 1 B4478591 Mini Gel Tank Base 1 B4478640 Empty Gel Cassette Combs, mini, 1.0 mm, 10 well 25 combs NC3010 Empty Gel Cassette Combs, mini, 1.0 mm, 12 well 25 combs NC3012 Empty Gel Cassette Combs, mini, 1.0 mm, 15 well 25 combs NC3015 Novex Power Supply Adapters 1 set ZA10001 Pipette Tips for Gel Loading Quantity Cat. no. Gel Loading Tips (Standard Round) 200/pk LC1001 Flat Gel Loading Tips 200/pk LC1002 Gel Loading Tips (Eppendorf Round) 200/pk LC1010 Pre-Mixed Buffers Quantity Cat. no. Novex Tris-Glycine SDS Sample Buffer (2X) 20 ml LC2676 NuPAGE Sample Reducing Agent (10X) Novex Tris-Glycine SDS Running Buffer (10X) 250 µl NP0004 10 ml NP0009 500 ml LC2675 4 1 L LC2675-4 5 L LC2675-5 Handcast System User Guide 15

Technical support Obtaining support For the latest services and support information for all locations, go to thermofisher.com At the website, you can: Access worldwide telephone and fax numbers to contact Technical Support and Sales facilities Search through frequently asked questions (FAQs) Submit a question directly to Technical Support (techsupport@lifetech.com) Search for user documents, SDSs, vector maps and sequences, application notes, formulations, handbooks, certificates of analysis, citations, and other product support documents Obtain information about customer training Download software updates and patches Safety Data Sheets (SDS) Safety Data Sheets (SDSs) are available at thermofisher.com/support. Certificate of Analysis The Certificate of Analysis provides detailed quality control and product qualification information for each product. Certificates of Analysis are available on our website. Go to thermofisher.com/support and search for the Certificate of Analysis by product lot number, which is printed on the box. Limited product warranty Life Technologies Corporation and/or its affiliate(s) warrant their products as set forth in the Life Technologies General Terms and Conditions of Sale found on Life Technologies website at www.lifetechnologies.com/termsandconditions. If you have any questions, please contact Life Technologies at www.lifetechnologies.com/support. 16 Handcast System User Guide

For support visit thermofisher.com/support or email techsupport@lifetech.com thermofisher.com 25 January 2016