Owner s Manual Table of contents 2 Introuduction & Safty Standard 3 Important considerations 4 Identify Parts & Description 5 Massage System 6 Toepia Chair Assembly 7 Toepia LX Armrest Assembly Toepia Spa Specifications 9 Toepia LX Spa Specifications 10 Testing & Cleaning 11 Maintenance for (Genijet) 12 Maintenance for (Whirlpool Pump) 13, 14 Optional Discharge Pump installation guide 15 Lubrication on Chair 16 Light System 17 Disinfection your pedicure spa 1 User recommendation 19 UL 20 Back Flow Prevention Device 21 Trouble Shooting Guide 22 Warranty Statement 23 2
Introduction Thank you for purchasing the Toepia Whirlpool Pedicure Spa. This finest Whirlpool Pedicure Spa has been developed by J&A USA, Inc. to operate dependably for many years when used properly. Please take time to read this entire manual thoroughly before installation and use. PLEASE READ AND FOLLOW INSTRUCTIONS CAREFULLY! Important Precautions J&A USA requires that you contact your local, qualified electrician and plumber to install your Toepia Whirlpool Pedicure Spa. It cannot operate efficiently or safely unless it is provided with adequate electrical power, sufficient water pressure, proper water temperature and required drain facilities. Information on these important subjects contained in this manual. We urge you to read it carefully to make sure these requirements are met. Precautions 1 Excessive water temperature is dangerous and should be checked before use. Maximum water temperature should not exceed 100 deg. F. (3 deg. C.). 2 Always enter and exit the Whirlpool Pedicure Spa slowly and carefully. 3 Never bring and/or operate any electrical devices into or near the Whirlpool Pedicure Spa. 4 Do not stand in the whirlpool tub! 5 This Whirlpool Pedicure Spa has a weight capacity of 250lb. WARNING Do Not use if you are diabetic, have poor blood circulation, or if any area of your feet or legs are inflamed or have open wounds. Consult a physician before using if you have any kind of fungal infection, swelling, fracture, or persistent pain. Massage should be pleasant and comfortable. IF YOU EXPERIENCE PAIN OR DISCOMFORT, DISCONTINUE USE IMMEDIATELY AND CONSULT A PHYSICIAN. This product in whole is in compliance with the applicable UL LISTED standards and requirements for the US and Canada by Underwriters Laboratories Inc. Some of the components of this product are also in compliance with the applicable safety standards of the following: 3
Important Considerations Please read the following instructions thoroughly Inspection Please take time to inspect each pedicure spa shipment thoroughly for damages immediately upon delivery. If damages are found, it is very important to notify the freight driver and indicate extent of the damages on the bill of lading. If you fail to do so, J&A USA will not be responsible for the damages and may not be able to make appropriate claims to the freight carrier. Any damage claims must be filed directly by receiver to the freight carrier. Electrical Service Each Foot spa must have its own dedicated 115V, 60 Hz, 15 Amp GFCI protected grounded circuit. Water Supply Water supply to the Toepia pedicure spa should consist of a system that will provide both adequate water pressure and water temperature. All plumbing connections must conform to local codes. Water Pressure Normal water pressure of 30 to 120 P.S.I. is required to correctly fill the tub to the proper level. Back Flow Prevention Device - For following states: AZ, CA, CT, IL, MI, MN, NE, NV, OR, TX, WA, and WI; All Toepia pedicure spa are equipped with factory installed Dual Check Back Flow Preventer. Specification: Tested and certified to meet ANSI/ASSE standard 1024. CSA certified to standard No.B64.6 Pressure / Temperature Maximum pressure: 150 psi (10 bars) Minimum pressure: 10 psi (69kPa) Working temperature: 33F to 140F constant; intermittent to 10F (0.6C to 60C sustained; intermittent to 2.2C) Maximum recommended flow: 15 gpm (571pm) -For all other states: As an option, the Dual Check Back Flow Preventer will be factory installed. * Inquire with governing authorities for local installation requirements. Drain Facilities Connect the Foot spa drain to meet local plumbing codes. Please refer to the installation drawings on pages 9~11 Foot spa is recommended securely fastened to the floor Fasten the Foot spa with at least two fasteners. Installation Summary The installation must comply with local, state, and federal building, plumbing and electrical codes, where applicable. A licensed plumber should complete the plumbing of the pedicure spa. Note: Failure to comply with federal, state or local codes and ordinances will result in warranty being null and void. 4
Toepia Identify Parts on Toepia Series Sliding armrest Massage Remote Faucet Air controller Dual functional shower head Footrest On/Off switch Pipe-less Jet Cover One Jet - 5
TOEPIA Single Remote Control System Massage + Chair ON/OFF Tapping Seat cushion vibration on/off Recline Forward Slide Forward Recline Backward Slide Backward Kneading 6
Toepia Series Chair Assembly Toepia & Toepia LX WITH WHIRLPOOL JETS IMPORTANT ASSEMBLY INSTALLATION PRIOR TO USE BEFORE ASSEMBLY AFTER ASSEMBLY 5 6 7 1 2 3 1) WHIRLPOOL PUMP POWER CORD 2) LIGHT BOX POWER CORD 3) CHAIR MASSAGE POWER CORD CHAIR ASSEMBLY FOR PETRA 700 & 500 SERIES 1) REMOVE HITCH PIN AND CLEVIS PIN FROM RECLINING PISTON 2) LIFT THE CHAIR AND PLACE THE RECLINING PISTON ON SUPPORT ARM BRACKET 3) INSERT CLEVIS PIN 4) SECURE WITH HITCH PIN CLIP Toepia & Toepia LX WITH PIPE-LESS (ONE JET) GENIJET Toepia & Toepia LX WITH PIPELESS (TWO JETS) SANIJET 1 2 3 4 1 2 3 1) LIGHT BOX POWER CORD 2) GENIJET POWER CORD 3) CHAIR MASSAGE POWER CORD 4) ONE OUTLET CONTROL PLUG IN BOX 1) LIGHT BOX POWER CORD 2) SANIJET CONTROL BOX POWER CORD 3) CHAIR MASSAGE POWER CORD 7