POWER TRANSFORMERS MVA kv. ISO 9001: Żychlin, ul. Narutowicza 70 ISO 14001:2004 PN-N-18001:

Similar documents
OBIS LX/LS Laser Box. Laser Mount with Cooling, Interface and Power Supply FEATURES & BENEFITS

PARTS LIST FOR WC-150-0ME3 WATER CANNON. Copyright 2000, Mi-T-M Corporation Issue Date:

PARTS LIST FOR WC-100-0ME3 WATER CANNON. Copyright 2000, Mi-T-M Corporation Issue Date:

Operating Instructions

Operating Instructions

The Shard of London 19 June / 44 INTRODUCTION CONTENT - OPERATING WITH 50 COMPANIES IN 27 COUNTRIES

Assistance for finding the right locks and fittings PAGE Numerical index... A 4

Freedom Line RMN with INNOVATOR Doors or INNOVATOR III Doors Technical Data Sheet P/N _D NSF Certified December 2012

OBIS Galaxy Integrated System

CoolTec. CT6cc CT5cc CT4cc CT4s CT3cc CT2cc CT2s. Type 5676

Owner s Manual. Table of contents 2. Introuduction & Safty Standard 3. Important considerations 4. Identify Parts & Description 5.

STERN TUBE SEAL STERN KEEPER C-TYPE MANUAL

Cartridge Machine USER MANUAL

Part No Revised: June Sno-King. Instruction Manual Model #1888. Cincinnati, OH USA

OBIS LX/LS Single Laser Remote

STRING LINES. If the frame is not fitted straight plumb and level the doors will not function correctly.

Series 7. Series7. trimmer. Series 7. off. sensitive. intensive. clean. high. low. empty. reset

Series7. Series 7. trimmer. Series 7. off. sensitive. intensive. clean. high. low. empty. reset

INSTRUCTION MANUAL Washbasin lifts

Sash Open Area Module (SOAM)

V-Solder BON-7103/7203

Bringing STYLE to the High Street

Series7. Series 7. trimmer. Series cc. off. sensitive. intensive. clean. high. low. empty. reset

ISO Sharps injury protection Requirements and test methods Sharps containers

Series cc. Series 7. Type Series 7. trimmer. Series cc. off. sensitive. intensive. clean. high. low. empty.

Prosonic TM. 790 cc. Type trimmer. off. eco. normal. clean. intensive. high. auto select. low. empty. reset

OBIS LX/LS Single Laser Remote

Series 5. Series cc. Type Series 7. trimmer. Series 7. off. 760 cc. sensitive. intensive. clean. reset

Instructions and Safety notices

Electric Shaver User's manual

Prosonic TM. trimmer. off. eco. normal. clean. intensive. high. auto select. low. empty. reset

Model #7650 Instruction Manual Patent Pending

Cyclone Sand Pro Debris Blower. Parts Catalog. Form Number Model No and up.

MAKERBOT METHOD PAGE 1

ISO INTERNATIONAL STANDARD

HKS909. Diode laser. User&Training Manual

Charging base. Trimming head (30mm) on charging stand. Main body unit. On/Off switch. Indicated light. Connecting jack Connecting jack

135g (unit with the big epilation head) 130g (unit with the small epilation head / unit with the shaver head)

Operating Instructions

Owner s Manual. Maintenance for Pipeless (Sanijet ) 12, 13. Maintenance for Standard Pedicure Spa (Whirlpool Pump) 15, 16

Prosonic BS washable clean. trimmer. off. eco. normal. intensive. high. auto select. low. empty. reset

Bano washbasin / brackets / outflow pipe / height adjustable module

10XE AND 15XE Electric High-Pressure Washer

Vertical Sliding Sash Windows

OBIS Galaxy. Fiber Input, Fiber Output, Eight Channel Beam Combiner FEATURES

Part No Revised April Sno Konette. Instruction Manual. Deluxe Model #1002S Standard Model #1003S. Cincinnati, OH USA

Operating Instructions

Operating Instructions. Model No. ES-LF70. (Household) AC/Rechargeable Shaver. English 17

care & maintenance Keep your windows looking and working great It s more than a window. It s a whole new point

Installation & Operations Manual for Energenics Multi Dryer Flat Mount (FM) Utility Free OPL Series Lint Filters

ISO INTERNATIONAL STANDARD. Protective clothing for protection against chemicals Classification, labelling and performance requirements

Portavant 60. twinline NEW! Brochure. The twin-track sliding door moves two sashes with the same gentle action as one! Glass fittings with logic

Fume Hood ECON VAV Controls

Hair Clipper. User's manual

Tilt Specify Tube Length & Bearing Color When Ordering Actual Diameter 9/16". Referred to as 5/8" in Trade. Tube. Bearing Rod.

Neon LED Signs. Created by John Park. Last updated on :11:09 PM UTC

Genesis Spa. Technician Comfort. G e n e s i s Pedicure Spa

KM-S824 Modern Salon Spa Pedicure Chair Plumbing Free

washable start stop washable Contour 5897 charge

Toy Car Speed Timer. Created by Kirby Griese. Last updated on :13:49 PM UTC

Architectural Information Page: Series 616 Magnum Awning Window Introduction

Luxury shows through details. Prostor. Program

Inductive Sensors BES.... the rugged Ones for extreme Applications

MEVA Stair Tower. Contents. Product List

8/2016. Protective clothing for firefighters TIGER MATRIX. 3rd category of Personal Protective Clothing

Oil & Gas. Simplified Frac Iron System

Adafruit Capacitive Touch Sensor Breakouts

3D Printed 20w Amplifier Box

10 PIECE LOW VOLTAGE GARDEN LIGHT SET

Hour Vision Manufacture Co-Axial

SyncroPro. Type 5492 Type

OBIS LX/LS Scientific Remote

BLE Light Switch with Feather nrf52840 and Crickit

Instructions for Use DO105625B

Assembly Instructions

LADY SHAVER WASHABLE LS 7140

Tender Notice No. DGVCL/SP/10048/Ind. Safety Shoes, PVC Boot & Rain Coat. Item No. 1 : Specifications of Industrial Safety Shoes

Safety Angel Instruction

OPT SHR IPL. Skin & hair treatments. A must for patient to enjoy perfect skin without pain. Big spot size with 20HZ fast speed.

FUME HOOD AUTO-SASH CONTROLLER

CosmoPage Dual Run & Blot System

Fabric Inspection Guideline

Calipers. Created by Ladyada

PR O ST YL E. Men s Foil Shaver. Model Number: AP Product Number: INSTRUCTION MANUAL. Version 5 - Issued 01/09/15

i-twin Trim Dual Blade Rechargeable Trimmer

THE NEW REFERENCE TECHNOLOGY FOR SLIDING SYSTEMS

Series 456 Commercial Awning Window

CARE & MAINTENANCE. Keep your windows looking and working great

08/2016. Protective clothing. FUN-COM Polo. Personal Protective equipment of category II

08/2016. Protective clothing. NOMEX underwear. Personal Protective equipment of category II

Topdresser 1800 Workman

ATS-SOI-5731 Page: 1 of 5. Approval Block. Prepared by: Signature Date Margaret Crouse 18 JUN Reviewed by: Signature Date

Portable IPL System. Principle and Application

Care & Maintenance. Keep your windows looking and working great.

R E S I D E N T I A L S E R I E S

3D Printed 20w Amplifier Box

INTERRUTTORI CREPUSCOLARI ASTRONOMICI. Manuale d Uso. memo AST2. Astronomical twilight switches: User Manual

Hammer Time Mini Golf Hazard with Crickit

PrecisionCut Hair Clipper

Con Badge with Circuit Playground Express

Transcription:

ISO 9001:2000 99-320 Żychlin, ul. Narutowicza 70 ISO 14001:2004 PN-N-18001:2004 www.ftz.pl Secretary s Office Tel.: +48 24 285 46 05, Fax: +48 24 285 46 31 zarzad@ftz.pl Sales and Marketing Department Tel.: +48 24 285 18 53, Fax: +48 24 285 47 53 marketing@ftz.pl Technical Department Tel.: +48 24 285 47 85, Fax: +48 24 285 46 31 technika@ftz.pl Quality Management Department Tel.: +48 24 285 48 31, Fax: +48 24 285 47 45 kontrola@ftz.pl Logistics Office Tel.: +48 24 285 47 52, Fax: +48 24 285 46 30 logistyka@ftz.pl POWER TRANSFORMERS 2.5-80 MVA 6-132 kv

Applications Power transformers are mainly used for reduction in power grids from high HV to medium MV (transformer/switching stations) or for transmission of MV/HV electric energy in combined heat and power stations and wind farms (unit transformers). In addition, power transformers are built for the purpose of MV/MV power switching and transmitting in power grids. Operating conditions The transformers in standard version are designed for operation in the conditions of moderate climate. Maximum installation height for the transformer: 1000 m a.s.l. Operating place: Open space or the room with sufficient ventilation; atmosphere free of dust and chemically active or explosive gases. Ambient temperature range: Rated frequency: -25 C up to +40 C (248 K up to 313 K), average annual temperature not exceeding +20 C (293 K). 50 Hz The transformers are designed for continuous operation and load conditions comply with the PN-EN 60076-1 and PN-EN 60076-2 standards. NOTE: Special versions of transformers complying with other requirements are available on request. Design Transformer cores: Three-legged cores made of cold-rolled, low power loss transformer plates covered with inorganic insulating material. Stepped cross-section of the core leg is nearcircular with optimal structure designed with the aid of computer software, taking into account the cross-section filling factor and suitable flux density. Both leg and yoke sheets made in the form of strips with chamfered ends are carefully assembled in packets, thus ensuring reduction of no-load losses and noise level. In the splicing area several sheets are mutually offset by several millimeters and form so called Step-Lep cycles.

Transformer windings: Regulation: Tanks: Oil conservator: Radiators: The windings of transformers are made of electrolytic copper with paper insulation consisting of several up to a dozen or so parallel conductors. The cooling system is usually made in the form of wedges and inserts made of insulating pressboard. The transformer is equipped with in-built on-load tap changer on the HV side. The tap changer is operated by 3x400/230 V, 50 Hz electric motor. Control is 230V, 50 Hz. The tap changer drive can be electrically controlled, both remotely and locally. Moreover the tap changer can be operated manually by using a crank. The tap changer drive is equipped with tap position indicator. The tank with no additional equipment can withstand the pressure difference between inner and outer pressure equal to ±500 hpa. The tank design allows lifting the transformer by using hydraulic jacks or by overhead travelling cranes or other types of cranes. The tank is coated with lacquer resistant to atmospheric conditions. The conservator may consist of one or two chambers (in the latter case the separate chamber is designed for onload tap changer). Radiators are installed on transformer tank i detachable manner, so they can be removed if a need be. The radiators are equipped with oil draining plugs and deaerating plugs. Since the radiators are mounted to the tank through gate valves, oil in transformer s tank can be separated from radiators. The radiators are available in galvanised or painted version. Undercarriages and housings: Transformers are mounted on standard undercarriage with railway gauge of 1505 mm (1435 mm between rails). On Customer request the transformer can be equipped with undercarriage with other rail gauge or be mounted on skids. Equipment of the transformer sample taking valves for testing of oil from top and bottom part of the tank; oil draining and filling valves on the tank and conservator and valves for oil filtering; plugs in the tank bottom for draining of deposit and oil residues; earthing terminals on the tank; brackets and lugs for lifting and pulling the transformer; adjustable flanged wheels in undercarriage for moving the transformer in two directions; wheel track of 1505/3010 mm.

Bushings: The following bushings are installed in the transformer cover: three upper side line bushings, one upper side neutral bushing and three lower side bushings. Control and measuring devices: Buchholz relay with contacts for signalling and transformer de-energizing; pressure relay for on-load tap changer; one or two magnetic indicators for oil level in the conservator (for transformer and tap changer) with signalling contacts operating when oil is below the minimum allowable level; two air dehumidifiers; dial-type contact thermometer for measuring of oil temperature, with maximum temperature indicator and contacts for signalling and de-energising of the transformer; resistance thermometer with indicator, for installation in switching station. safety valve with triggering contacts; control circuits for protecting devices are connected to terminal box installed on the transformer. Tolerances: no-load losses +15% load losses +15% total losses +10% no-load current +30% short-circuit +10% International standards and requirements: PN-EN 60076-6 PN-EN 60076-1 PN-EN 60076-2 PN-EN 60076-2 PN-EN 60076-8 PN-EN 60076-10 PN-EN 60296 - Power transformers. Reactors) - Power transformers - Part 1. General requirements - Power transformers - Part 2. Temperature rise for liquid-immersed transformers - Power transformers - Part 3. Insulation levels, dielectric tests and external clearances in air - Power transformers - Part 8. Application guide - Power transformers - Part 10. Determination of sound levels - Fluids for electrotechnical applications. Unused mineral insulating oils for transformers and switchgear NOTE: It is possible to build transformers according to other specified standards and requirements.

Exemplary specifications: Transformers with on-load regulation Power Upper side Lower side Regulation Short-circuit Vector group No-load losses On-load losses Item Type kva V V % % - W W kg kg 1. TORc 4000/16,5 4000 16500 6300 ±10/±8st 6 YNd11 4000 25000 12000 3300 2. TORc 6300/16,5 6300 16500 6300 ±12/±8st 7 YNyn0 5500 40000 14800 3800 3. TORc 6300/115 6300 115000 16500 ±10/±8st 7,5 YNd11 7500 37000 18200 4500 4. TORc 8000/10,5 8000 10500 6300 ±11 7 Yy0 6000 50000 22000 7000 5. TORc 10000/30 10000 31500 6300 ±2x2,5 7 YNd11 11500 59000 16500 3200 6. TORc 10000/115 10000 115000 16500 ±10/8st 10,5 YNd11 7000 65000 24600 6900 7. TORc 16000/10,5 16000 10500 6300 ±10/8st 8 Yy0 10000 80000 28700 6800 8. TORc 16000/30F 16000 31500 6300 ±10/6st 8 YNd11 11000 95000 31200 7500 9. TORc 16000/115 16000 150000 16500 ±10/8st 12 YNd11 11000 95000 31000 7500 10. TOTRc 16000/115 16000/16000/10000 115000 16500 ±10/9st 11/16/18 YNy0d11 15000 90000/30000/50000 41000 10800 11. TORc 20000/31,5 20000 31500 6300 ±10/8st 8 YNd11 11000 95000 31600 7100 12. TORc 20000/115 20000 115000 10500 ±10/8st 11 YNd11 13900 119000 32500 7500 13. TORc 25000/13,8 25000 13800 6300 ±10/6st 15 Yy0 12000 175000 39800 9800 14. TORc 25000/115 25000 115000 16500 ±10/8st 12 YNd11 14000 130000 42000 9500 15. TORc 25000/115F 25000 115000 15750 ±15/12st 11 YNd11 12000 155000 39000 9000 16. TORc 31500/115 31500 115000 6300 ±10/8st 12 Ynd5 19000 145000 42000 9500 17. TORc 31500/115F 31500 115000 16500 ±10/8st 18 YNd11 15000 155000 41000 9700 18. TORc 32000/115 32000 115000 15750 ±10/8st 16 YNd11 14000 160000 51200 9500 19. TORc 40000/115 40000 115000 22000 ±15/10st 13 YNd11 21000 180000 50000 12400 20. TORc 40000/115F 40000 115000 21000 ±10/8st 11 YNd11 21000 158000 46600 11000 21. TOTRc 40000/115 40000/25000/40000 115000 6300/15750 ±15/12st 18/11/6 YNd11d11 13100 171000 61000 12500 22. TOTRc 40000/115F 40000/20000/20000 115000 10500/10500 ±16/9st 10,5/10,5/25 YNd11d11 21500 150000 58000 13100 23. TORc 45000/110F 45000 110000 6300 ±10/8st 15,75 YNd11 26000 193000 57200 12400 24. TOTRc 50000/15 50000/25000/25000 15750 6300/6300 ±10/8st 8/8/16,5 Yy0y0 21000 120000/120000/280000 66500 17200 25. TOTRc 50000/115 50000/50000/16670 115000 15750(10500) ±15/10st 18 YNyn0(d5) 17500 245000 67000 19000 26. TORc 53000/110 53000 110000 20000 ±15/10st 14,5 YNd11 25000 230000 65000 14500 27. TORc 60000/115F 60000 115000 15750 ±10/8st 18 YNd11 23000 235000 61000 12500 28. TORc 69000/112F 69000 112000 20000 ±12,5/10st 11,5 Yd11 28000 300000 75000 16200 29. TORc 80000/121 80000 121000 10500 ±10/8st 13,5 YNd11 33000 310000 74500 15000 Mass, total Oil mass

Transformers with off load regulation Power Upper side Lower side Regulation Short-circuit Vector group No-load losses Load losses Item Type kva V V % % - W W kg kg 1. TOc 4000/35 4000 35000 6300 ±2x2,5 6,5 YNd11 4300 28000 11600 2250 2. TOc 6300/20 6300 21000 6300 ±2x2,5 7 YNyn0 6500 42000 14000 2750 3. TOc 7500/15 7500 15750 11000 ±2x2,5 7 Dd0 6500 46000 15300 3600 4. TOc 8200/15 8200 15750 15750 ±2x2,5 6 Dd0 7500 43000 14500 2900 5. TOc 10000/15 10000 15750 10500 ±2x2,5 7 YNd11 11000 63000 16000 3700 6. TOc 10000/30 10000 31500 6300 ±2x2,5 7 YNd11 11500 59000 16500 3200 7. TOc 12500/33 12500 32950 1050 ±5,335/2st 8 YNd5 6000 67500 23500 3900 8. TOc 16000/20 16000 21000 10500 ±2x2,5 8 YNyn0 17000 100000 32400 6700 9. TOc 16000/22 16000 22000 22000 ±2x2,5/5st 8,5 YNd11 9500 85000 20000 3500 10. TOc 16000/30 16000 31500 6300 ±2x2,5/2st 8 YNd11 9500 85000 22500 3900 11. TOc 25000/30 25000 31500 6300 ±2x2,5 8 YNd11 18000 120000 37000 7500 12. TOc 30000/110 30000 110000 10500 ±10/8st 11 YNd11 21000 145000 42500 8900 13. TOc 40000/115 40000 150000 10500 ±10/4st 12,5 YNd11 20000 140000 68000 16000 14. TOc 63000/30 63000 33000 10500 ±2x2,5 13 YNd11 28000 280000 71000 13600 Mass, total Oil mass NOTE: The transformer can be made for the complying with the standard: 6, 10, 15, 20kV or other (from the range of 1-37.5 kv), as well as for various short-circuit s, no-load losses and on-load losses. It is also possible to build the transformer with other, previously agreed additional equipment.

Dimensional drawing : 1. Upper bushing 2. Lower bushing 3. Neutral bushing 4. Tap changer 5. Tap changer drive 6. Tank 7. Cover 8. Undercarriage 9. Oil conservator 10. Conservator oil filling cap 11. Conservator lifting lugs 12. Oil drain from conservator 13. Magnetic oil level indicator 14. Safety valve 15. Buchholz relay 16. Tap changer air dehumidifier 17. Transformer air dehumidifier 18. Ball valve 19. Radiators 20. Radiator gate valve 21. Residual oil drain from radiator 22. Electric junction box 23. Dial type contact thermometer 24. Contact thermometer sensor 25. Maximum reading thermometer 26. Resistance thermometer socket 27. Residual oil drain 28. Oil filler ball valve 29. Bolts for oil tests 30. Ball valve for oil filling and filtering 31. Earthing bolt 32. Deaerating bolt 33. Pins for lifting the transformer 34. Lugs for pulling the transformer 35. Manholes for lifting of transformer removable part 36. Brackets for lifting the transformer 37. Rating plates 38. Fans 39. Buchholz relay

Approximate dimensions: Transformers with on-load regulation Item Type A B C H mm mm mm mm 1. TORc 4000/15 2560 4150 1505 2730 2. TORc 6300/16,5 2740 4150 1505 2890 3. TORc 6300/115 2810 4995 1505 3350 4. TORc 8000/10,5 2630 4535 1505 3844 5. TORc 10000/30 2880 3715 1505 3270 6. TORc 10000/115 2900 5500 1505/3010 3715 7. TORc 16000/10,5 2900 5410 1505 3935 8. TORc 16000/30F 2730 5200 1505 3800 9. TORc 16000/115 3090 5400 1505/3010 3900 10. TOTRc 16000/115 3365 5960 1505/3010 5165 11. TORc 20000/31,5 3115 5080 1505/3010 4030 12. TORc 20000/115 3090 5320 1505/3010 4050 13. TORc 25000/13,8 3150 5620 1505/3010 4035 14. TORc 25000/115 3350 6180 1505/3010 4200 15. TORc 25000/115F 2900 5700 1505/3010 4180 16. TORc 31500/115 3110 5730 1505/3010 4320 17. TORc 31500/115F 3360 6100 1505/3010 4230 18. TORc 32000/115 3225 6185 1505/3010 4290 19. TORc 40000/115 3430 6210 1505/3010 4450 20. TORc 40000/115F 3030 6010 1505/3010 4470 21. TOTRc 40000/115 3150 6100 1505/3010 4750 22. TOTRc 40000/115F 3080 5730 1505/3010 4670 23. TORc 45000/110F 4060 6260 1505/3010 4990 24. TOTRc 50000/15 3940 7040 1505/3010 4515 25. TOTRc 50000/115 3440 6550 1505/3010 4850 26. TORc 53000/110 3800 6300 1505/3010 4660 27. TORc 60000/115F 3500 6120 1505/3010 4700 28. TORc 69000/112F 3905 6510 1505/3010 5225 29. TORc 80000/121 3950 6480 1505/3010 5265 Transformers with off load regulation Item Type A B C H mm mm mm mm 1. TOc 4000/35 2400 3135 1505 3040 2. TOc 6300/20 2180 3240 1505 3485 3. TOc 7500/15 2630 3620 1524 3350 4. TOc 8200/15 2890 3435 1505 2815 5. TOc 1000/15 2460 3860 1505 3610 6. TOc 10000/30 2880 3715 1505 3270 7. TOc 12500/33 2750 4000 1505 3300 8. TOc 16000/20 3010 4720 1505 4065 9. TOc 16000/22 2380 4040 1505 3580 10. TOc 16000/30 2750 3910 1505 3280 11. TOc 25000/30 2940 4450 1505 4430 12. TOc 30000/110 3670 5435 1505/3010 4325 13. TOc 40000/115 3920 6570 1524/2000 5100 14. TOc 63000/30 4170 5980 1505/3010 4800

NOTE: The manufacturer reserves the right to change specifications presented in the catalogue and resulting from product modernisation. Other versions can be agreed with the factory. The Factory is providing in-warranty and post-warranty service, inspections and repairs of its products.