Tattoo Darkening and Nonresponse After Laser Treatment A Possible Role for Titanium Dioxide STUDY E. Victor Ross, MD; Sharam Yashar, BS; Norm Michaud, MS; Richard Fitzpatrick, MD; Roy Geronemus, MD; Whitney D. Tope, MPhil, MD; R. Rox Anderson, MD Objective: To examine relationships between chemical composition, biopsy findings, and clinical outcome in laser-treated tattoos. Design: Observational nonblinded retrospective study. Settings: University-based dermatology clinic and private practice. Participants: Twenty patients who underwent biopsy of laser-treated tattoos. Main Outcome Measures: Biopsy specimens were analyzed after laser treatment, and the depths of changed particles were recorded. Ultrastructure of the changed particles was examined by electron microscopy. Presence of inorganic chemicals was determined by x-ray diffraction. orrelation between x-ray diffraction, microscopy, and clinical response was attempted. Results: Of the 20 tattoos, 7 lightened, 9 failed to change, and 4 darkened after laser treatment. There was a significant association between presence of titanium dioxide and poor response to laser therapy. Microscopic studies showed variable changes in the ink particles, but there was a trend toward residual deep green pigment in the resistant tattoos. Also, round dark stippling was observed superficially in the darkened specimens. onclusions: Titanium is overrepresented in tattoos that respond poorly to laser treatment. Further studies are necessary to show whether this metal is the primary cause of this poor response. Arch Dermatol. 2001;137:33-37 From the Department of Dermatology, Naval Medical enter San Diego, San Diego, alif (Dr Ross and Mr Yashar); Wellman Laboratories of Photomedicine, Massachusetts General Hospital, Boston (Mr Michaud and Dr Anderson); Dermatology Associates, Encinitas alif (Drs Fitzpatrick and Tope); and Laser and Skin Surgery enter of New York, New York, NY (Dr Geronemus). Dr Tope is now with the Department of Dermatology, University of Minnesota, Minneapolis. MANY TATTOOS are resistant to laser treatment, particularly those containing blue, purple, yellow, green, and flesh-toned dyes. 1,2 For example, while some green tattoos clear completely after only 2 to 3 treatment sessions, others do not lighten or may even become darker. The mechanism by which tattoos darken after laser treatment is not completely understood. One factor may be the laser-induced reduction of metallic compounds used in certain dyes. A potential offender is titanium dioxide (TiO 2 ), which is an increasingly popular white ink used to enhance the brilliance of tattoos. 3 Titanium is most commonly found in green, white, and flesh-colored tattoos; however, it has been identified in tattoos of almost any color. 4 To explore a possible association between TiO 2 and tattoo response to laser treatment, we examined the metallic composition of a series of treated tattoos in this pilot study. RESULTS Tattoo colors and metal compositions are summarizedintable1.ofthe20tattoosstudied, 7 lightened significantly throughout the whole tattoo, 9 were at least partly resistant, and 4 became darker. Of the 13 tattoos that responded poorly, all except 2 contained titanium, whereas in the 7 tattoos that lightened considerably after laser treatment, only 2containedtitanium. WiththeuseofaFisher exact test, there was a significant association between the presence of titanium and a poor response to laser therapy (P=.02). In general, tattoos that failed to lighten showed higher ink density than those that responded favorably (Table 2). All samples of colored (nonblack) pigment appeared to be heterogeneous by light microscopy, showing mixtures of colored and indeterminate brown-black granules. Within the group of resistant green tattoos, 2 types of pigment granules were seen: (1) a large and rounded globular granule (2-5 µm in diameter; Figure 1A) 33
SUBJETS AND METHODS Biopsy specimens were obtained in this retrospective analysis from consenting patients participating in tattoo treatment protocols with the use of Q-switched ruby (Spectrum Medical Technologies, Natick, Mass) or Nd:YAG (on- Bio, Livermore, alif) lasers. Each patient was treated by an experienced dermatologist with a protocol expected to achieve an adequate clinical response. Green tattoos were treated with the ruby laser with fluences of 4 to 7 J/cm 2 and spot sizes of 5 to 6 mm. Red tattoos were treated with a frequency-doubled Nd:YAG laser with fluences of 2 to 4 J/cm 2 and spot sizes of 2 to 3 mm. Black tattoos were treated with an Nd:YAG laser at 1064 nm with fluences of 4 to 8 J/cm 2 and a spot size of 2 to 3 mm. Patients received at least 6 treatments with 1 or a combination of lasers before biopsy. Tattoo colors are summarized in Table 1. A total of 20 patients were included in the study. For most of the tattoos, only posttreatment biopsy specimens were available. Biopsy samples were handled in 1 of 2 ways. Some tissue was processed for paraffin embedding and stained with hematoxylin-eosin. Representative sections were left unstained and were used to assess the density of ink particles and depth of microscopic lightening induced by laser. The rest of the tissue was processed for electron microscopy. Specimens were fixed in 4% glutaraldehyde in 0.1-mol/L cacodylate buffer, dehydrated, and embedded in epoxy resin. Postfixation in osmium tetroxide was omitted to enhance the x-ray analysis. Sections 1 µm thick were examined either unstained or stained with toluidine blue O. Thin sections were stained with saturated uranyl acetate and Sato lead stain or left unstained and examined in an electron microscope (M10; Phillips, Hillsboro, Ore). All specimens underwent x-ray diffraction studies for detection of metallic elements. Paraffin-embedded specimens were cut at 10 µm and mounted directly on an aluminum stub for use in scanning electron microscopy. Paraffin was removed from the sample with xylene, and a layer of carbon was applied to the surface of the section. These samples underwent x-ray microanalysis on a scanning electron microscope (Amray 1400; Amray, Bedford, Mass) with an x-ray detector (Kevex, Valencia, alif). Samples processed in epoxy resin were cut at 90 nm and placed on a carbon and polyvinyl formal coated grid for examination with a transmission electron microscope (Philips Biotwin; Phillips) equipped with an x-ray detector. Both methods produced spectral signatures for elements present within the tissue. A Fisher test was used to determine if there was a significant correlation between presence of titanium and tattoo resistance and/or darkening. We excluded tattoos found to contain iron oxides from the data analysis, as they are known to darken with treatment. To observe the direct effects of laser irradiation on titanium, a 5% TiO 2 cream (Ti-Screen Natural; Pedinol, Farmingdale, NY) was irradiated with a Q-switched Nd:YAG laser (Schwartz Electro-optics, Orlando, Fla) with a fluence of 7 J/cm 2. Table 1. Summary of Tattoo Features Tattoo olor and onstituents (No. of Tattoos) Resistant (n = 9) Darkening (n = 4) Good Response (n = 7) Green, titanium (5) Green, titanium and chromium (1) Green, chromium (1) Black, titanium (1) Red, titanium (1) White/flesh, titanium (2) Red, mercury (1) Purple, titanium (1) Black, no peak (5) Black, titanium (1) Green, titanium (1) that tended to break down into smaller round particles of various sizes when treated (Figure 1B) and (2) crystalline granules (5-10 µm in diameter; Figure 1) that showed a tendency to splinter with therapy (Figure 1D). hanges in granule shape were less conspicuous with increasing depth of the samples. In both types of specimens after treatment, there was a transition from translucent brownish granules (0.5-1 µm) with small black inclusions (like a stippling) located superficially, to larger, more opaque bright-green granules (1-3 µm) appearing unchanged by the laser starting about 500 µm deep in the dermis (Figure 1A). Scattered among the deeper granules were stippled aggregates of smaller 1-µm granules similar to those noted in the superficial biopsy regions. The number of these smaller dark dots appeared constant from 500 to 1500 µm deep in the skin. However, more superficially, there was a progressive decrease in Table 2. Electron Microscopic Findings of Particle, Granule, and Density of Tattoos Resistant Darkening Good Response Granule depth, µm Range 200-1300 200-1000 200-1000 Mean 700 600 500 Particle size, nm Deep 200/1000-2000* 60-300 40 Superficial 15-250/50-150* 20-300 60 Granule size, µm Pretreatment 1-5 2-5 1-3 Posttreatment 1-2 2-5 1-3 Density of ink (light microscopy) 4+ 3+ 2+ *Globular/crystalline. their number such that they were rarely observed in the uppermost sections of the specimen (200 µm deep). By transmission electron microscopy, resistant green tattoos showed some cells with lysosomes containing pale material with a few dark particles in treated areas (Figure 1B). (Note: In this study, we defined particle as the smallest identifiable structure on electron microscopy. This is distinguished from granule, which we defined as the smallest structure observed on routine light microscopy, usually 0.5 to 10 µm in diameter, ie, the particlecontaining lysosome.) Other specimens showed more crystalline particles evenly distributed in the cytoplasm (Figure 1D). In both cases (globular and crystalline), 34
A B D Figure 1. A, Light micrograph of an unstained 6-µm paraffin section showing the presence of large globular green pigment (original magnification 100). B, Electron micrograph of a treated region of the same tattoo shown in A. There are large lysosomal structures that contain round pigment particles (arrowheads) of varying sizes. Most of these particles are much smaller than the pigment particles found in the untreated areas (bar indicates 0.2 µm). All particles retain a round shape., Light micrograph of an unstained 6-µm paraffin section showing large green crystalline structures (original magnification 100). D, Electron micrograph of a treated region of the tattoo shown in. Note the large electron-dense structures as well as the smaller similarly dense structures around them (arrowheads). indicates crystal (bar indicates 0.2 µm). areas from the deeper dermis, the presumed untreated regions, showed larger, more homogeneous particles. In the 4 tattoos that underwent darkening, light microscopy showed large granules (1-3 µm) deeper in the dermis that appeared unaltered by laser treatment. Exclusively in a thin band (about 100 µm thick; Figure 2A) in the superficial parts of the specimens (about 200-300 µm in depth), smaller (1 µm), darker round bodies appeared as stippling within these granules. In the more superficial ( treated ) areas of the specimens, these small bodies were more loosely distributed, as compared with a more aggregated, denser, clumped distribution in the untreated deeper regions of the sections. By transmission electron microscopy, the appearance was similar, with more heterogeneity seen superficially, where specimens showed a mixture of apparently unchanged particles (approximately 500 nm in diameter on electron microscopy) and smaller (50-100 nm) and changed darkened particles (Figure 2B and ). Mercury was found in the one red specimen that darkened. The histologic findings were similar to those of the other 3 darkened tattoos, with the exception that in the superficial (ie, treated) dermis there were both larger reddish granules and smaller, presumably changed, granules. 35
A B E Figure 2. Micrographs from a biopsy specimen of a treated tattoo that changed from flesh color to black on treatment. A, Light micrograph of an unstained 6-µm section (unseen epidermis [E] at top) showing changed pigment in the upper dermis and unchanged pigment in the deeper dermis (bar indicates 20 µm). B, Electron micrograph of an unstained (osmium tetroxide only) thin section from superficial dermis showing great variability in the size of the pigment particles (arrowheads) within the lysosomes. Most are, however, much smaller than the particles seen in (bar indicates 0.2 µm)., Electron micrograph of the tattoo pigment from the deeper dermis showing unchanged pigment particles (bar indicates 0.2 µm). Microscopically, in treated tattoos that lightened considerably (most of which were black), there was smudging and a light-brown color superficially, with little or no peppering. Deeper in the dermis, homogeneous black granules were noted. By transmission electron microscopy, treated parts of the specimens showed a mixture of electron-dense and electron-lucent particles, with many of the electron-lucent (changed) particles showing slightly increased size (60-100 vs 40 nm) compared with their unchanged electron-dense (native) counterparts. Laser irradiation of the 5% TiO 2 cream resulted in a dramatic immediate color transformation from bright white to bluish-black. OMMENT Mechanisms for tattoo removal after Q-switched laser irradiation are not clearly understood. It is presumed that the absorption of short-pulse energy produces high temperatures in the ink particles, resulting in death of inkladen phagocytic cells. 5 Tattoo clearing may occur via particle fragmentation, phagocyte cell death and subsequent egress via lymphatics, transepidermal elimination, or intrinsic optical property changes in the pigment granules. 6-8 Resistance to laser treatment may be related to early rephagocytosis of particles by fibroblasts, excessive amounts of ink, depth of particles, failure of temperature and pressure stresses to alter particles, and electrochemical changes in the valence state of inorganic dyes subjected to highpower laser irradiation, as described below. Tattoos containing ferric oxide, a brown-red ingredient widely used in red, pink, and flesh-colored tattoos, have been reported to result in a black discoloration when treated with the Q-switched ruby laser. The mechanism is thought to involve the reduction of ferric oxide, which is rust colored, to ferrous oxide, which is jet black. 9 A similar phenomenon may be involved in white and other iron-free inks that contain titanium. In the untreated tattoo, titanium is in the TiO 2 form, which is bright white. High-intensity laser irradiation has been shown to result in the reduction of Ti 4+ to Ti 3+, which is responsible for the blue color. 10 We demonstrated this color change by irradiating a titanium-enriched sunscreen. Tope et al 11 studied tattoo ink gels containing TiO 2 and iron oxide and found that changes were both wavelength and pulse duration dependent. Most important, they were unable to induce tattoo ink darkening in tattoos with pulse durationsgreaterthan1millisecond, suggestingthatathreshold power density is required for tattoo ink darkening. Interestingly, there is evidence to support spontaneous bleaching of ink darkening in tattoos containing titanium. 12 This observation is supported in vitro, where, on exposure to air, there is bleaching of the blue discoloration after 3 to 4 months. 10 White ink, composed of about 95% TiO 2, is commonly used to brighten green, blue, yellow, and purple tattoos. The resulting mixtures are made such that green inks, for example, are typically composed of about 30% to 40% TiO 2. (These data were obtained in a recently completed pilot study with a newer energy dispersive x-ray microanalysis device. [A. L. Timko, MD,. H. Miller, MD, F. B. Johnson, MD, E.V.R., unpublished data, 1999]). Therefore, it is possible that tattoos with a large titanium fraction turn deeply black with Q-switched laser treatment, whereas other tattoos with smaller titanium burdens darken so little with laser irradiation that they appear grossly not to lighten. With repeated treatments of green tattoos, one possible scenario is that that the green organic portion, at least superficially, is being eliminated, whereas the titanium portion is darkening. One of the difficulties in this study is correlating the electron microscopy and light microscopy results with the clinical findings. For example, we have noted that, in resistant green biopsy specimens, there is considerable remaining green ink at the base of the gross specimen, with less gross green color superficially. This was confirmed his- 36
tologically, as we saw more large green granules deeper in the treated specimens. This observation suggests that simply the application of more surface fluence would remove the remaining deep green pigment. Higher fluences would presumably overcome depth-related attenuation of the laser beam, as well as any competition for light absorption by the TiO 2 intermixed in the deeper remaining green pigment. Accordingly, the deeper green pigment would be eliminated while any mild ink darkening (graying) should be grossly undetectable. Presumably, whatever is responsible for ink darkening would tend to occur higher in the specimen, where the subsurface fluence is greatest. In the tan tattoo that darkened, we did note increased stippling on light microscopy, which might explain the gross darkening; perhaps this was TiO 2 being altered, as we did not find this stippling deeper in the specimen. On the other hand, we were unable to determine a reliable histologic correlate for resistance in green tattoos, as stippling was noted in both superficial and deep areas of the specimen and was more prevalent deeper in the specimen. Without knowing where the TiO 2 is ultrastructurally (and, just as important, its ultrastructural appearance before and after treatment), one can only speculate as to actual physical changes occurring within the specimen during laser irradiation. The limitations of the study are several. First, the tattoos were not all subjected to the same treatment protocol; however, every tattoo was treated by a highly experienced dermatologist with a protocol expected to result in optimal clearing. Second, tattoos were not matched for anatomic site or age of the patient, skin type, age of tattoo, depth of pigment, density of pigment, or ink color. Third, although our analysis detected the presence of all constituent metals in each tattoo, it was not designed to find the relative amount of metal present in each specimen. Optimally, one would search for matched controls between the 3 groups (resistant, darkening, and lightening) with respect to location, age, and, most important, ink color. In this retrospective study, we initially limited enrollment to tattoos that were either resistant or darkened with treatment. Subsequently, we added a good responder group to serve as a control. Unfortunately, the good responder group could not be matched for color, as we observed that a disproportionate number of green tattoos responded poorly and that black tattoos generally responded well. Thus, color is a confounding variable; unfortunately, most green tattoo inks contain TiO 2.Itisinteresting that clinicians generally note that green tattoos are the most difficult to treat. Often a green tattoo lightens about 50% after 2 to 4 treatments, only to fail to lighten considerably more with even up to 20 additional treatments. The lack of response in green tattoos is interesting, as there is evidence that red light (alexandrite or ruby laser) is well absorbed by green inks. 13 It is unknown, however, whether TiO 2 is playing a role in resistance or, alternately, whether there is simply a higher damage threshold for the organic azo-dyes commonly used as green tattoo inks. Green tattoos are not singularly resistant to treatment; other ink colors are also characteristically resistant. For example, we have found that purple and yellow inks are difficult to treat, even though they, too, show at least fair absorption of one or another commonly used Q-switched laser; these ink colors also usually contain TiO 2. Probably, green has become such a nuisance color largely because of its prevalence. It is our experience that the 3 most common tattoo colors are black, green, and red. Of these, red and black respond well in most instances, and these inks typically contain no titanium. The ultimate test of TiO 2 as an independent risk factor for resistance would be a comparison of green inks with and without TiO 2. However, although our study incorporated6colors,webelievethattheoverrepresentationoftio 2 inpoorrespondersanddarkeningtattoosisdueatleastpartly to elemental composition and not solely tattoo color. Moreover, at least for the darkening tattoos, the microscopic correlation (increased stippling and heterogeneity of granules after treatment) and presence of TiO 2 make a compelling argument for titanium s role in the gross observations. The results of this study should encourage other investigations of tattoo ink composition and its relation to laser treatment success. A larger, more systematic study is necessary to individuallyassesstherolesoftitanium, inkdensities, inkdepth, and ink color. Experiments in animal models with the placement of controlled tattoos with known concentrations of inks and metal components would be invaluable. If additional compounds are identified that darken with laser irradiation, it may be prudent for manufacturers to search for alternative dyes so that permanent but laser-friendly tattoos might be available in the future. Accepted for publication July 27, 2000. orresponding author and reprints: E. Victor Ross, MD, Department of Dermatology, Naval Medical enter, 34800 Bob Wilson Dr, Suite 5, San Diego, A 92134-1005 (email: evross@nmcsd.med.navy.mil). REFERENES 1. Ferguson JE, August PJ. Evaluation of the Nd/YAG laser for treatment of amateur and professional tattoos. Br J Dermatol. 1996;135:586-591. 2. Ferguson JE, Andrew SM, Jones J, August PJ. The Q-switched neodymium: YAG laser and tattoos: a microscopic analysis of laser-tattoo interactions. Br J Dermatol. 1997;137:405-410. 3. Lehmann G, Pierchalla P. Tattooing dyes [in German]. Dermatosen Beruf Umwelt. 1988;36:152-156. 4. Slater DN, Durrant TE. Tattoos: light and transmission electron microscopy studies with x-ray microanalysis. lin Exp Dermatol. 1984;9:167-173. 5. Zelickson BD, Mehregan DA, Zarrin AA, et al. linical, histologic, and ultrastructural evaluation of tattoos treated with three laser systems. Lasers Surg Med. 1994;15:364-372. 6. Taylor R, Anderson RR, Gange RW, Michaud NA, Flotte TJ. Light and electron microscopic analysis of tattoos treated by Q-switched ruby laser. J Invest Dermatol. 1991;97:131-136. 7. Taylor R, Gange RW, Dover JS, et al. Treatment of tattoos by Q-switched ruby laser: a dose-response study. Arch Dermatol. 1990;126:893-899. 8. Ross V, Naseef G, Lin G, et al. omparison of responses of tattoos to picosecond and nanosecond Q-switched neodymium:yag lasers. Arch Dermatol. 1998; 134:167-171. 9. Anderson RR, Geronemus R, Kilmer SL, Farinelli W, Fitzpatrick RE. osmetic tattoo ink darkening: a complication of Q-switched and pulsed-laser treatment. Arch Dermatol. 1993;129:1010-1014. 10. Torimoto T, Fox R III, Fox M. Photoelectric electrochemical doping of TiO 2 particles and the effect of charged carrier density on the photocatalytic activity of microporous semiconductor electrode film. J Electrochem Soc. 1996;143:3712-3717. 11. Tope W, Tsoukas M, Farinelli W, Anderson R. Tattoo ink darkening: the effect of wavelength, fluence, and pulse duration [abstract]. Lasers Surg Med. 1996 (suppl 8):40. 12. Narurkar V, Stevenson T. Paradoxical darkening of areolar pigmentation from post-mastectomy areolar reconstruction by the Q-switched double frequency ND- YAG laser [abstract]. Lasers Surg Med. 1997(suppl 9):58. 13. Hodersdal M, Bech-Thomsen N, Wulf H. Skin reflectance guided laser selections for treatment of decorative tattoos. Arch Dermatol. 1996;132:403-407. 37