BLEACHING AND Q-SWITCHING OF U 2+ :CaF 2 AT 1535nm

Similar documents
Highly efficient, narrow-linewidth, and singlefrequency actively and passively Q-switched fiber-bulk hybrid Er:YAG lasers operating at 1645 nm

Design and realization of a compact and multi-purpose passively Q-switched ND:YAG laser system

Comparison of CW Pumping and Quasi-CW Pumping for a Passively Q-switched Nd:YAG Laser

We are where you are!

Analysis of Passively Q-Switched Lasers With Simultaneous Modelocking

Stable Q-switched mode-locked Nd 3+ :LuVO 4 laser by Cr 4+ :YAG crystal

We are IntechOpen, the first native scientific publisher of Open Access books. International authors and editors. Our authors are among the TOP 1%

ExQ-Laser. Q-Switched Nd:YAG Laser Therapy Systems

Passively Q-switched Ytterbium doped fiber laser with mechanically exfoliated MoS 2 saturable absorber

Semiconductor saturable absorber mirror passively Q-switched 2.97 μm fluoride fiber laser

ComplexCity Q-Switched Nd:Yag

Wavelength-tunable, dual-wavelength Q-switched Ho 3+ -doped ZBLAN fiber laser at 1.2 µm

AESTHETIC PRECISION THE SAFEST AND MOST PRECISE LASER TREATMENT SOLUTION AVAILABLE FOR PIGMENTED LESIONS AND MULTI-COLOR TATTOO REMOVAL

Heriot-Watt University

HKS909. Diode laser. User&Training Manual

Lasers. Conditions of laser operation. Classification of lasers. Continuous wave lasers (He-Ne) Pulsed lasers (Nd-YAG, Ti:Sa)

FIBER OPTIC IRONING DIODE LASER EPILASION!

a revolution in Q-Switched technology

LUCID QY/Q-PTP. 1064nm/532nm Q-Switched Nd:YAG Laser

The legacy behind Q-switched technology. MedLite C

OBIS Galaxy. Fiber Input, Fiber Output, Eight Channel Beam Combiner FEATURES

Science. Results. Trust.

Passive Q-Switching of an All-Fiber Laser Using WS 2 -Deposited Optical Fiber Taper

EFFECTS OF FLUENCE AND PULSE DURATION

OBIS Galaxy Integrated System

Micro-Fractional & Whole Beam Technology Ablative Vaporization + Non-Ablative Coagulation Multiple Profitable Indications

FIBER OPTIC IRONING DIODE LASER EPILATION!

MAXIMUM POWER TRIPLE MODE Q-SWITCHED, LP AND QLP ND:YAG LASER SYSTEM 3 PULSE DURATIONS 4 DISTINCTIVE WAVELENGTHS MULTIPLE INDICATIONS

Scanner Optimized Efficacy (SOE) Hair Removal with the VSP Nd:YAG Lasers

P-808. Hair removal- Faster, painless and better

Discovery PICO Series

The first report of short intense pulses of laser light, called giant pulses at the time, was. By David Welford

Passively Q-switched photonic crystal fiber laser and intracavity optical parametric oscillator

OPT SHR IPL. Skin & hair treatments. A must for patient to enjoy perfect skin without pain. Big spot size with 20HZ fast speed.

Premium Q-Switched Nd:YAG

MORE PRO THAN EVER 2000W. High power DIODE LASER PLATFORM GUARANTEED QUALITY. by cocoon medical

Be an artist of the new era.

P NM DIODE LASER HAIR REMOVAL SYSTEM. Beijing Sanhe Beauty S & T Co., Ltd

Q-Plus Series. Taking care of people, our masterpieces. Q-Switched Laser Platform Tailored to Your Needs. Aesthetics

Hair Removal Using a Combination of Electrical and Optical Energies Multiple Treatments Clinical Study Six Months Follow up

The world s fastest SLT/YAG laser.

elase with Motif A New Picture in Pain Free Hair Removal Science. Results.Trust.

A new generation of technology. For a new generation of patients. Elite MPX. Powered by MultiPlex

My study in internship PMT calibration GATE simulation study. 19 / 12 / 13 Ryo HAMANISHI

AD-A ration PAGE ApBrov7d

Q-Plus EVO. Q-Switched Laser Platform Tailored to Your Needs TECHNICAL SPECIFICATIONS RESULTS BEFORE / AFTER ACCESSORIES. Rx Only.

Black phosphorus Q-switched large-mode-area Tm-doped fiber laser

INNATE ABILITY MOTUS AX. The New Era of Hair Removal. Hair Removal Benign Pigmented Lesions

Introducing the new LUMINA Laser and IPL platform

Fluorescence from Pearls of Freshwater Bivalves and Its Contribution to the Distinction of Mother Oysters Used in Pearl Culture

A Q-switched fibre laser operating in the 2 mu m region based on nonlinear polarization rotation technique

Q: Switch ND: YAG Laser Skin Care System Model SQ-2

Shell Microspheres for Ultrahigh-Rate Intercalation Pseudocapacitors

EXTREMELY POWERFUL AND COMPACT Q-SWITCH Nd:YAG LASER

SkinScience. Natural Skin Care In It s Purest Form. Now it can be used in the comfort of one s own home. SkinScience Co., Ltd.

GentleYAG Pro-U. Outstanding Results. Treating Multiple Indications. Upgradable. Science. Results.Trust.

Passively Q-switched erbium-doped fiber laser using evanescent field interaction with gold-nanosphere based saturable absorber

Selectivity (but, how?)

NEW 3 Wavelengths and Resolve Fractional. The Complete Picosecond Platform

Episode 504: How lasers work

Light and Heat Energy (LHE ) Technology Review of a Novel Approach to Hair Removal

The neov Perfect Nails without Medication. The neov surgical laser platform at 1064 nm

Laser Hair Removal: Results Of 2-Week Versus 6-Week Treatment Intervals

Springs of well-being

SATURABLE absorbers (SAs) are widely used in the passively

OLIVE. Top Hair Removal Diode Laser System

What is Pico second laser?

SYNCHRO QS4 MEDICINE AND AESTHETICS SYNCHRO QS4. Maximum Results and Safety in Treating Multicolored Tattoos and Pigmented Lesions

Article Compact Narrow Linewidth Actively Q-Switched Er Yb Double-Clad Fiber Laser

It is under the author s own responsibility

M22. All you need. All in one. AESTHETIC.LUMENIS.COM

M22. All you need. All in one. LUMENIS.COM/AESTHETIC

FORMATION OF NOVEL COMPOSITE FIBRES EXHIBITING THERMOCHROMIC BEHAVIOUR

LASER HAIR REMOVAL: SCIENTIFIC PRINCIPLES AND PRACTICAL ASPECTS

Passively Q-Switched Microchip Lasers and Applications

THE HIGH-TECH LABORATORY FOR HAIR REMOVAL EPILATION FACE BODY NOT FOR SALE IN THE U.S.A.

a noticeable difference in tattoo removal

Lasers Principles Types And Applications Borner

What is Pico second laser?

High power (600W) 808nm diode. Shall We THE Tango? Perfect Solution for Permanent Hair Removal

lumenis one the power of performance

C-Band Q-Switched Fiber Laser Using Titanium Dioxide (TiO 2 )As Saturable Absorber

How To Measure In Vivo UVA and UVB Blocking Sunscreens and Cosmetics on Human Skin

MOTUS AY INNATE ABILITY. The All-In-One Simple Solution for Aesthetic Medicine and Dermatology

Think Outside the Eye. Treat Skin and Eyelid Inflammation. *

Using ONYX Separation Control Tool. Contents: What is Separation Control? Using ONYX Separation Control Tool. Separation Control Tips and Tricks

Portable IPL System. Principle and Application

InnoLas Photonics GmbH. Company & Product Presentation

THE UNMATCHED STARS FOR PROFESSIONAL HAIR REMOVAL. Brochure not for the U.S.

Design and Construction of a Q-switched Laser

M22. All you need. All in one. LUMENIS.COM/AESTHETIC

STUDY OF MANUFACTURING THERMOCHROMIC WOOD. Zhijia Liu. Fucheng Bao* Feng Fu*

Portable Picosecond Nd Yag Laser System

The Perfect All-In-One Tattoo Removal Laser. Science Engineering Design Versatility Ease-of-Use Practicality

Think Before you Ink: Modeling Laser Tattoo Removal

SHORT pulse fiber lasers, because of their short duration and

IPL hair removal. Our Beauty Our Beurer. Clinically tested technology for maximum safety at home. Safe, fast and reliable.

Tattoo Removal With an Electro-optic Q-Switched Nd:YAG Laser With Unique Pulse Dispersion COS DERM

IPL hair removal. Our Beauty Our Beurer. Clinically tested technology for maximum safety at home. Safe, fast and reliable. Beautiful and wellgroomed

ProCutiGen Hold Efficacy Data

Transcription:

Part of combined papers presented at Photonics West, SPIE Vol. 2379, Solid State Lasers and Nonlinear Crystals, 1995 BLEACHING AND Q-SWITCHING OF U 2+ :CaF 2 AT 1535nm Yasi Jiang', Ruikun Wu, Daniel L. Rhonehouse, Michael J. Myers, John D. Myers and Scott J. Hamlin Kigre, Inc. 100 Marshland Road Hilton Head Island, SC 29926 Phone: (803)-681-5800 Fax: (803)-681-4559 *Shanghai Institute of Optics & Fine Mechanics, Chinese Academy Of Science, P.O. Box 80021 1, Shanghai 201800. P. R. of China Phone: 86-21-953-4540 Fax: 86-21-952-8812 ABSTRACT Divalent uranium doped CaF 2 Q-switch has been tested as a saturable absorbing Q-switch. Laser output at 1535nm with l0mj of energy and a 60ns pulse width was demonstrated at 8.5Hz by using U 2+ :CaF 2 as a saturable absorbing Q-switch. The laser media is QE7S and an experimental Er:glass designated QX/ER. INTRODUCTION Laser emission at 1535nm, due to the 4 I 13/2-4 I 15/2 transition in Er 3+ :glass, is attractive due to its eyesafe wavelength and ability to transmit with low attenuation through the atmosphere and commercial silica fibers. Additionally, the long fluorescent lifetime (6 l0ms) makes Er 3+ :glass an attractive candidate for laser diode pumping. 1535nm lasers are particularly useful for rangefinding, lidar, communications, and atmospheric data measurements. High repetition rate, high peak power Q-switched pulses are often required for many applications. Mechanical devices, such as rotating mirrors, porro prisms and frustrated total internal reflection (FTIR), are common methods of Q-switching lower repetition rate Er 3+ :glass lasers. Electro-optical Q-switched Er 3+ :glass lasers are also available for use at various repetition rates [1]. Passive Q-switching using a saturable absorber may provide a simple, compact, reliable and more economical alternative when compared to these active switching methods. Using the characteristics of the self-absorption of Er 3+ in a solid state host, Danker demonstrated passive Q- switching using Er 3+ :phosphate glass [2] and a low 4 I 13/2 fluorescent lifetime Er 3+ :borosilicophosphate glass [3]. Q-switched pulses were also experimentally obtained by researchers at the Center for Laser Studies of the University of Southern California using Er 3+ doped 1

FAP and CaF 2 [4]. Intracavity focusing was necessary to raise the intracavity power density in order to optimize Q-switching in the low absorption cross section Er 3+ doped glass and crystal Q-switch materials. The results typically revealed a Q-switched giant pulse followed by a train of free running spikes or multiple Q-switched pulses. Passively Q-switched pulses of 3mJ and 60ns pulse width were successfully obtained using tetravalent uranium doped strontium fluoride (U 4+ :SrF 2 ), by R. D. Stultz et al. [5]. In this paper, we report on the bleaching of divalent uranium doped calcium fluoride (U 2+ :CaF 2 ), and the results of passively Q-switching an Er 3+,Yb 3+ :phosphate glass laser at 1535nm. SPECTRA AND BLEACHING Uranium has an outer electronic shell of 5f 3 6d7s 2 and has been found to exhibit various valence states, (U 2+, U 3+ and U 4+ ) in fluoride crystals. The absorption and fluorescence of uranium in a number of experimental fluoride crystals were measured and reported by W.A. Hargreaves [6,7,8]. Divalent uranium exhibits a broad absorption band centered at 1580nm. This corresponds to a metastable energy level at 5 L7 with a fluorescence emission at 2600nm. A CaF 2 sample doped with 0.5 atom percent U 2+ revealed absorption bands at 2530, 1580, 1190, 1100, 650, 540 and 480nm The absence of any appreciable absorption in the 2100 to 2300nm region or the UV (Caused by U 3+ and U 4+ ) indicates the presence of a nearly pure U 2+ valence. The U 2+ exhibits a relatively 2

large absorption cross section at a 1535nm. This in combination with a moderate metastable lifetime are important characteristics for a saturable absorbing Q-switch. The absorption spectra in the vicinity of the 1580nm peak region for U 2+ :CaF 2 is illustrated in Figure 1. The absorption cross section at 1535nm was calculated to be 7.0 x 10-20 cm 2. This value is appreciably larger than the stimulated emission cross section of 0.8 x 10-20 cm 2 for Er 3+ in phosphate glass. Bleaching experiments were conducted by measuring the transmittance of the samples at various energy densities using a Kigre QE7S Er 3+ :C 3+ :Yb 3+ :phosphate glass pulsed laser. A focusing lens and filters were utilized to increase or attenuate the incidence fluence to the sample. A beam splitter was used to monitor the incidence fluence. Figure 2 illustrates the transmittance as a function of incidence energy. The curve with square symbols represents experimental results while the sohd line is a curve fitted according to the equation by Frantz and Nodvik [9]: T=(F sat /F in )ln(t 0 (Exp(F in /F sat )-1) + 1). Where F sat is the saturation fluence, F in is the incident fluence and T 0 is the initial transmittance of the sample. The saturation fluence is 57J/cm 2 calculated from experimental data. This is only an approximate value due to the long pumping pulse duration. 3

Q-SWITCHINGDue to the large absorption cross section at 1535nm of U2:CaF 2 in comparison to the stimulated emission cross section of Er 3+ in phosphate glass, intra-resonator focusing was not necessary The first Q-switch experiment was conducted using a normal Er:glass laser resonator, in which the HR mirror is 60cm concave and output coupler is 300cm concave. The 0.5mm diameter of the TEM 00 mode was nearly constant over the entire cavity length. Q-switch sample #l had an initial transmission of 82.9%. Output energies of 2mJ and about 60ns pulse widths were obtained in both TEM 10 and TEM 30 modes with 33J of pumping. Decreasing the initial transmission to 64% in sample #2 yielded a higher output energy of 6.9mJ with higher transverse modes and a pulsewidth of 27ns with an 87J pump. Adjusting the resonator alignment produced very clear mode patterns such as TEM 00, TEM 10, TEM 20, TEM 30, TEM 40, TEM 50, TEM 60, as well as some cylindrical modes. For certain modes, the output energy was found to be quite stable; for example 1.6mJ in TEM 00 and 2.5mJ in TEM 10. The maximum output energy was achieved with a combination of TEM 00 and cylindrical TEM 08 modes. This combination of modes has a maximum mode volume and produced output energies up to 6.9mJ. An interesting observation was that the bleaching time for the TEM 00 and the cylindrical TEM 08 modes are slightly different and a double pulse output was observed. The delay between the two pulses varied from 50ns to 400ns. We are convinced, this kind of double pulse behavior is completely different from the normal meaning of "double pulse" in saturable absorber Q-switch lasers. Table 1. Summarized Data of Q-switch Experiments BEAM@ INPUT REP. OUTPUT PULSE MODE CAVITY SAMPLE SIZE RATIO* ENERGY RATE ENERGY WIDTH STRUCTURE 82.9% 0.5 1:1 33J 1HZ 2.Omj 55ns TEM30 1 64.0% 0.5 1:1 33 1 1.6 27 TEM00 64.0% 0.5 1:1 87 1 6.9 27 TEM00+ High 82.9% 1.04 1.08 53 1 6.4 60 CYL01 82.9% 0.9 1.21 53 1 8.2 55 CYL01 II 82.9% 0.92 1.21 36 1.5 7.5 65 CYL01 82.9% 0.53 1.37 33 3.0 6.2 65 MIXED MODE 82.9% 0.72 1.41 40 1.5 7.6 65 CYL01 82.9% 0.75 1.47 38 8.5 10 60 MIXED MODE III 82.9% 0.88 1.25 38 8.5 5 65 CYL01 @ Beam size was calculated according TEM 00 mode. Ratio of beam size (TEM 00 mode) in rod to absorber 4

In order to further increase the Q-switched output a new laser resonator was designed with a variable diameter of mode volume along the axis of the resonator. In this resonator, the influence of the mode size upon the saturable absorber could be easily observed. 8.2mJ of energy with a 55ns pulsewidth was obtained when the saturable absorber sample #1 was moved to the proper beam position with a pump of 53J at l Hz. Table 1 summarizes the results of this experiment illustrating that the control of the beam size in the saturable absorber is very important Finally, with Kigre's newly developed QX/ER high average power Er:glass exhibiting a maximum thermal loading three times greater than standard QE-7S or about 37OW for a 3X75mm rod, we were able to operate the laser at 10Hz with a 35J pump. The thermal lensing produced by pumping the rod at repetition rates was matched in the resonator design to optimize the spot size in the U 2+ :CaF 2 passive Q-switch for a single pulse output. Accounting for the thermal lensing in the laser rod, the resonator design produce a high order mode output of l0mj at 8.5Hz utilizing Q-switch sample #l. This resonator is illustrated in figure 3. All Q-switch samples were not anti-reflection coated and exhibited poor surface figure and optical quality. We believe that considerable performance improvements are possible; however, this is the first reported operation of a flashlamp pumped, Q-switched, Er:Glass laser operating in excess of 4Hz. CONCLUSION Bleaching thresholds for the U 2+ :CaF 2 crystal have been qualitatively measured and reported. Repetitive passive Q-switching of an E 3+ :phosphate glass laser using intracavity U 2+ :CaF2 saturable absorber has been realized for the first time. The results of this work suggest that passive Q-switching of Er:glass lasers is a practical alternative to active Q-switching and may satisfy the demands of numerous eye-safe 1.54m laser applications. 5

ACKNOWLEDGEMENTS The authors would like to thank W.A- Hargreaves for his spectroscopists studies of Uranium Crystals. REFERENCES [1]S.J. Hamlin, J.D. Myers and M.J. Myers, SPIE Processing 1419,100 (1991) [2]B.I Denker, G.V. Maksimova, V.V. Osiko et al., Sov. J. Quantum Electron. 20,877 (1990) [3]B.I.Denker, G.V. Maksimova, V.V. Osiko et. al., Sov. J. Quantum Electron. 21, 774 (1991) [4]M.B. Camargo, R.D.Stultz, M. Bimbum and K Spariosu, CLEO '94 Technical Digest, 115 (1994) [5]R.D. Stultz, M.B. Camargo, S.T. Montgomery, M. Birnbum and K Spariosu, Advanced Solid State Lasers, 1994 Technical Digest, 348 (1994) [6]W.A. Hargreaves, Physical Rev. 156, 331 (1967) [7]W.A. Hargreaves, Physical Rev. B2, 2273 (1970) [8]W.,k Hargreaves, Private communication, (1992) [9]L. Frantz and J. Nodvik, J.Appl. Phys. 34,2346 (1963) 6