Disposable Cartridge NOSE Piercing System

Similar documents
Disposable Cartridge NAVEL Piercing System

Lenis Needle-free Safety Syringe Device User Manual

Procedure 30 Collecting A Blood Specimen Using The Vacuum-Tube System. Procedure 31 Collecting A Blood Specimen Using A Needle And Syringe

Table 6: Detailed Infection Prevention and Control Procedures for Tattooing and Micropigmentation. Use During Tattooing

Administering ORENCIA (abatacept): Your Step-by-Step Guide

Dangerous Things DIY RFID Implantation Guide Written by Amal Graafstra

Cartridge Machine USER MANUAL

Prosonic BS washable clean. trimmer. off. eco. normal. intensive. high. auto select. low. empty. reset

How to Give a Subcutaneous (SC) Injection to Your Child

MEDICATION AND INJECTION ADMINISTRATION EDUCATIONAL BOOKLET FOR OVULATION INDUCTION

Your Step-by-Step Guide

Nose and Ear Hair Trimmer

Revised 1/10. Copyright 2010 St. Jude Children's Research Hospital Page 1 of 5


Page 1 of 7. Hand-Held High Frequency C9220T

Series7. Series 7. trimmer. Series 7. off. sensitive. intensive. clean. high. low. empty. reset

Series 7. Series7. trimmer. Series 7. off. sensitive. intensive. clean. high. low. empty. reset

SHAVER 7300 S7370. Always here to help you. Rechargeable Cordless Tripleheader Shaver.

EnglisH introduction general description (Fig. 1) Preparing for use Charging

Hygienic requirements for tattoo and piercing studios

Series cc. Series 7. Type Series 7. trimmer. Series cc. off. sensitive. intensive. clean. high. low. empty.

Prosonic TM. 790 cc. Type trimmer. off. eco. normal. clean. intensive. high. auto select. low. empty. reset

Series7. Series 7. trimmer. Series cc. off. sensitive. intensive. clean. high. low. empty. reset

Series 5. Series cc. Type Series 7. trimmer. Series 7. off. 760 cc. sensitive. intensive. clean. reset

Table 5: Detailed Infection Prevention and Control Procedures for Body Piercing. drape the piercing site.

BODY ART FACILITY INFECTION PREVENTION AND CONTROL PLAN

Prosonic TM. trimmer. off. eco. normal. clean. intensive. high. auto select. low. empty. reset

TRANSGENDER HEALTH Injection Guide

Series cc 570 cc. Type on off. min. clean

Rechargeable Cordless Tripleheader Razor 8060X

Body Art Facility Infection Prevention And Control Plan Guideline

PHARMACY PRACTICE I LAB PHCY 280L

Coverings care guide 1

Prepared by Laurel Arrigona, Matt Bavougian, Michael Crea, John Johnson, Steve Joyner, Sarah Robbin, and KC Stevenson

CoolTec. CT6cc CT5cc CT4cc CT4s CT3cc CT2cc CT2s. Type 5676

State of Kuwait Ministry of Health Infection Control Directorate SAFE INJECTION

BODY ART FACILITY INFECTION PREVENTION AND CONTROL PLAN GUIDELINE

SHAVER 7500 S7720. Always here to help you. Rechargeable Cordless Tripleheader Shaver.

Coverings care guide PB

MASSAGE THERAPY & ACUPUNCTURE

S5280 S5210 S5205. Always here to help you. Rechargeable Cordless Tripleheader Shaver.

clean off auto select eco normal intensive cartridge full empty

Instruction of B108 Portable Diamond Dermabrasion Unit

#74 - CHANGING A MOIST TO DRY DRESSING (TEST)

Vacuum 5 in 1 Grooming Kit

Manual for Scorpion tattoo machine rev.2

THE WORLD S MOST INTELLIGENT FACIAL CLEANSING BRUSH

GOAL GATHER SUPPLIES CHANGE YOUR DRESSING CALL YOUR HEALTHCARE PROVIDER:

Grooming Gear Trimmer operating instructions

CONTENTS WORLD S LARGEST EAR PIERCING MANUFACTURER ABOUT US ADVANTAGES OF SYSTEM 75 STARTER KITS 14K 10K 18K GOLD 5-9 NOTES

7310XL 7315XL 7325XL 7340XL 7345XL 7349XL 7350XL. Rechargeable Tripleheader Cordless/Cord Razor

Sterilization A Training Module

BodyBare AquaSmooth. Instruction Booklet. wet & dry epilator AP17SR. Please read these instructions carefully and retain for future reference.

Home Care for Your Wound Drain

Device Performance Quick Guide 1

Current Status: Active PolicyStat ID: Original Policy: 10/1986 Last Reviewed: 01/2016 Last Revised: 01/2016 Next Review: 01/2019

S5390 S5370. Always here to help you. Rechargeable Cordless Tripleheader Shaver. Register your product and get support at

PLAN REVIEW APPLICATION PACKET BODY ART ESTABLISHMENTS

Be Spa Safe Your guide to PROTECTING yourself at the spa

Eyebrows Eyeliner Lips Colour Correction Trainings

Student Performance Guide. Student Performance Guide. Student Performance Guide. Student Performance Guide. LESSON 3-3 Bleeding Time

SM ART FAC IA L CLEANSING & MASSAGING BRUSH

SPECIMEN COLLECTION. A Study Guide

ROTARY PEN USER MANUAL

Rechargeable Tripleheader Cordless/Cord Razor 8240XL 8250XL 8251XL. Model 8240XL. Register your product and get support at

BIKINI TRIM WET/DRY BIKINI TRIMMING SYSTEM

FREQUENT REPLACEMENT CONTACT LENS. A Guide to Trouble-Free Contact Lens Wear (Instructions for Use)

Always check equipment to make sure it is in good shape. There should be no sharp edges or broken pieces.

$1,395 $2,795 $3,495. Simplicity

Cordless Ceramic Hair Cutting Set

BODY PIERCING AFTERCARE:

GENERAL ASSEMBLY OF NORTH CAROLINA SESSION 2001 H 1 HOUSE BILL 635. March 15, 2001

Material Safety Data Sheet

Figure A. Figure B To prevent premature activation of the needle safety guard, do not touch the NEEDLE GUARD ACTIVATION CLIPS at any time during use.

DICE-WITCH PRINCE CASTLE MODEL NO. 910-A Series

TATTOO AFTERCARE. Do not re-bandage the tattoo, as it could stick to the bandage and damage can occur!

Migraine Attack Abortive Treatment Medication Overuse Protocol Treatment Refractory Cluster Headache Treatment

washable start stop washable Contour 5897 charge

Procedure 19 Changing A Clean Dressing. Procedure 20 Applying A Bandage. Procedure 21 Applying A Sterile Dressing

MN250/251 MODELS BEARD/MUSTACHE TRIMMER

CHROME PLATINUM. Shavers. Double Edge

For Higher Education. Smarter Wellness

Home Care for Your Wound Drain After Breast Cancer Surgery


Type Syncro System Smart Logic

Holiday Twinkle Toes. Step-by-Step Guide

Professional Hair Removal System

SNS DIPPING POWDERS INSTRUCTIONS

Electric Shaver User's manual

New York State Department of Health. Body Art Program. Body Art: Tattooing and Body Piercing a public health regulatory program presented by the

PIERCING CONSENT RELEASE FORM PLEASE READ AND CHECK THE BOXES WHEN YOU ARE CERTAIN YOU UNDERSTAND THE IMPLICATIONS OF SIGNING THIS DOCUMENT

For Manufacturing. Smarter Protection

POP ACRYLIC NAILS. user guide

PT730 PT729 PT724. Always here to help you. Rechargeable Cordless/Cord Tripleheader Razor.

FlexCare Platinum. 5_020_9457_2_DFU-Luxury_A6_v1.indd 1 08/04/15 11:03

AT940, AT893, AT890, AT753, AT752, AT750

Shellac. Application & Removal. Fingernails. Step-by-Step

presents: A new orbital skin resurfacing technology with mechanical micropulsations

POWERGLIDE TITANIUM FEATURES

MINERAL LINE ALOE VERA RANGE

Transcription:

Disposable Cartridge NOSE Piercing System Operators Manual FINAL A001

Innovative. Safe. Professional. You have purchased the, the most innovative nose piercing system available today. Our engineers have designed the Medisept Nose Piercing System to provide piercing technicians and retailers with a safe and easy alternative to traditional nose piercing methods eliminating the costly expense of an autoclave and piercing needles. The patented design of the Medisept nose piercing instrument makes it easy to use, load and maintain. The Medisept sterilized nose piercing system offers touch free operation by using individually pre-sterilized cartridges for piercing. Each sealed cartridge contains one sterilized nose piercing stud designed to pierce the nose. The nose stud remains in place during the entire healing period. The Medisept Nose Piercing System is designed for piercing of the nostril only. It is not intended for piercing the septum or any other part of the nose or body. Sterilised Disposable Cartridge with Nose Piercing Stud Reusable Instrument Handle 1

Table of Contents Operating Instructions Instrument and Cartridge Features. 3 Preparation...... 4 Hand Washing...... 4 Customer Care...... 4 Cleaning the Instrument..... 4 Loading the Instrument 5 Nose Piercing Procedures Prepare. 6 Cleanse. 6 Marking the Nose... 6 Piercing the Nose... 7 Cartridge Removal and Disposal.... 7 After Piercing Care 8 Troubleshooting... 9 Instrument Guarantee.... 9 2

Instrument Features The ergonomic contoured grip is designed to fit hands of all sizes. The smooth linear action of the instrument helps promote precise, accurate piercing. The patented shape of the instrument accurately pierces the nose without touching the customers face. The cartridge channel allows for easy touch free loading and disposal of the sterilized piercing cartridge. (fig. 1) (fig.1) Cartridge Features Each cartridge is individually sterilized for safety. The unique shape of the cartridge is designed to fit easily and comfortably into the nose for accurate, virtually pain-free piercing. Each sterilized cartridge is contained in its own individual blister package enabling the user to safely load and dispose of each cartridge without touching the cartridge or piercing stud. (fig. 2) (fig. 2) Loaded instrument with cartridge (fig. 3) (fig. 3) 3

Preparation 1. Before every new customer prepare a clean work surface for the set up of the piercing instrument and cartridge, etc. 2. Using an anti-bacterial/germicidal wipe or solution wipe and clean the work surface. Place a clean paper cloth on the work surface. 3. Greet the customer and have them make their jewelry selection. 4. With your customer, review the Medisept nose piercing release and after care procedure form. Have them read and sign the form. 5. On your clean work surface, arrange the piercing instrument, disposable gloves, alcohol prep pad, Medisept marking pen, hand held mirror, Medisept after piercing care gel and Medisept Nose Piercing Cartridge. (fig. 4) 6. Hand your customer the hand held mirror to be held for the duration of the piercing service. (fig. 4) Hand Washing 7. Using antibacterial/germicidal hand soap, wash and rinse hands thoroughly. Avoid touching the faucet handle and nozzle if possible when turning the water on and off. Dry your hands thoroughly. If a sink and water are not available, use an alcohol based waterless hand sanitizer to cleanse hands thoroughly before piercing. (fig. 5) 8. After drying or sanitizing your hands, immediately put your disposable gloves on each hand before proceeding with the piercing service. Customer Care 9. Check the piercing site for any skin irritations or scar tissue as these could require special care when piercing. DO NOT pierce through cysts or moles as these could be harmful. Also, be sure to inspect inside the nose for any blockages. (fig. 5) Cleaning the Instrument It is essential to clean the Medisept nose piercing instrument BEFORE and AFTER each use. 1. With gloved hands, clean the entire instrument. 2. Use a 70% Isopropyl Alcohol wipe to clean the instrument. Do not wash or immerse in water! (fig. 6) (fig. 6) 4

Loading the Instrument 1. Place the nose piercing instrument inside the disposable cover. 2. Take the Medisept sterilized cartridge and gently remove the protective backing paper from the blister package. Set the blister and cartridge down on the prepared work surface. Do not remove the cartridge from the blister package. (fig. 7) 3. In one hand take the Medisept nose piercing instrument and hold it parallel to the clean surface. With the other hand take the blister package containing the piercing cartridge and place it on top of the instrument. (fig. 8) 4. Insert the front channel of the cartridge into the front of the instrument (fig.9). Then click the back of the cartridge down into the instrument. This will lock the cartridge in place. (fig. 10) (fig. 7) 5. Remove the blister package before piercing. (fig. 11) Do not discard the blister package, set it down on the clean surface for use during the disposal of the used cartridge. (fig. 8) (fig. 9) (fig. 10) (fig. 11) 5

Nose Piercing Procedure Mark 1. Using the 70% isopropyl alcohol prep pad, gently clean the surface of the nose where the piercing will be placed. (fig. 12) 2. Before marking, ensure the nose is completely dry after cleansing. 3. Using the Medisept marking pen, gently mark the spot where the piercing will take place. Usually in the crease. (fig. 13) 4. Have your customer confirm that the mark on the nose is in the correct location by looking into the hand held mirror. Do not remove the mirror from your customer. (fig. 14) (fig. 12) (fig. 13) (fig. 14) 6

Piercing the Nose 1. Take the blister off the cartridge. Position the cartridge end of the nose piercer into the nostril. Gently pull the instrument towards you so that the cartridge creates pressure on the inside of the nostril. Support the customer s head with your other hand. Ask your customer to close their eyes as this promotes relaxation for accurate piercing. (fig. 15) 2. Holding the instrument perpendicular to the nose at a 45º angle; gently squeeze the instrument until the point of the stud is positioned exactly over the piercing mark. You are now ready to pierce. (fig. 16) 3. With the stud positioned over the mark, squeeze the instrument handle firmly and evenly to a full stop. Hold this position for 2 seconds. (fig. 17) (fig. 15) 4. Release the handle, the cartridge will automatically disengage from the piercing stud. Slide the cartridge and instrument downward and away from the nose. (fig. 18) 5. Be sure that the piercing stud head is sitting flat against the nose. If required gently tap or push the piercing stud to this position on the nose with a gloved finger. Removing the Cartridge After the Piercing (fig. 16) 1. Take the empty blister package and place on top of the used cartridge while still in the instrument. 2. With your thumb and index fingers, pinch both sides of the cartridge firmly. 3. With the instrument in your hand, gently squeeze the handle to partially compress the instrument. Slide the cartridge forward while lifting it off and dispose of both the cartridge, cover and blister into an approved receptacle. (fig. 19) (fig. 17) (fig. 18) (fig. 19) 7

After Piercing Care 1. Take the Medisept after piercing care gel and apply 1-2 drops on to the outside of the piercing stud. (fig. 20) Do not allow the tip of the gel tube to touch the piercing. 2. Give the aftercare instructions to your customer and advise that they must use the Medisept after piercing care gel as part of their daily after care regimen. 3. Medisept professional piercing after care products are an essential part of a successful nose piercing. Medisept after piercing care gel and lotion are manufactured using the finest ingredients including Benzalkonium Chloride and Aloe Vera and are ph balanced for healthy skin. (fig. 20) MediSept After Piercing Lotion 4 FL.OZ. / 100mL MediSept After Piercing Care Gel.20 FL.OZ. / 6mL 8

Troubleshooting In a normal nose piecing procedure the nose stud will pierce through the nostril and sit flat on the outside of the nose. If the nose stud does not sit flat against the outside of the nose then gently tap the head of the stud with your gloved finger until it sits flat. In a normal nose piecing procedure the nose stud will pierce completely through the nostril. If the piercing instrument is not completely squeezed to the end then the nose stud may protrude and not completely pierce the nostril. If this is the case: Use your gloved finger and thumb to gently push the nose stud completely through the nostril and into place. In a normal nose piercing procedure there will be no blood. If there is a slight spot of blood on the outside of the nose then use an absorbent cloth and have the customer apply pressure on the outside of the nose for approximately one minute. To prevent or decrease the likelihood of fainting you should: Ask the customer if they have eaten within the last hour. If not suggest they have a sugary drink, juice or small snack. Engage the client in conversation to keep them preoccupied. Work quickly and confidently. Allow them to sit for a few minutes or until they are OK and they are up to walking. For any irregularities the customer must always consult their doctor before piercing! Lifetime Guarantee Medisept Professional Piercing Systems are made in the USA to meet or exceed US Food and Drug Administration and EC European medical standards for quality and hygiene. The Medisept Nose Piercing Instrument is backed by a limited lifetime guarantee to the original purchaser. This instrument is made in the U.S.A. and created using the highest quality materials and workmanship. Each Medisept Nose Piercing System component is subject to rigorous quality and safety standards regulated by the USFDA (food and drug administration) and EU (European Union). Visit www.medisept.com This guarantee is void if the instrument is misused or dropped, or is used with anything other than genuine Medisept piercing products. Copyright notice This manual and its content is copyright of MediSept - 2011. All rights reserved. Any redistribution or reproduction of part or all of the contents in any form is prohibited other than the following: you may print or download to a local hard disk extracts for your personal and non-commercial use only you may copy the content to individual third parties for their personal use, but only if you acknowledge the company name and website (www.medisept.com) as the source of the material You may not, except with our express written permission, distribute or commercially exploit the content. Nor may you transmit it or store it in any other website or other form of electronic retrieval system. 9