Infrared Technology for Skin Tightening A Hot Topic Utilizing Deep Dermal Heating

Similar documents
Lisa Chipps, MD, MS, FAAD Assistant Clinical Professor David Geffen School of Medicine at UCLA

Vider Itzhak MD2, Harth Yoram MD2,, Elman Monica MD, Gottfried Varda PhD3, Shemer Avner MD4, Beit Harofim

Successful treatment of periorbital rhytides with non-ablative technique using a simple radiosurgery device

ALL IN ONE OMNIMAX S4. All the must haves in one system

Peri-Orbital Non-Invasive and Painless Skin Tightening-Safe and Highly Effective Use of Multisource Radio-Frequency Treatment Platform

It All Adds Up. The Pellevé Wrinkle Reduction System

Single-Treatment Skin Tightening By Radiofrequency and Long-Pulsed, 1064-nm Nd: YAG Laser Compared

SharpLight Technologies: Nd:YAG Q-Switched Laser For Tattoo Removal White Paper Dr. Betty Czajkowsky M.D., Medical Advisor

MAXIMUM POWER TRIPLE MODE Q-SWITCHED, LP AND QLP ND:YAG LASER SYSTEM 3 PULSE DURATIONS 4 DISTINCTIVE WAVELENGTHS MULTIPLE INDICATIONS

Skin Laxity of the Face and Neck: Treatment Approach with the Titan Device. LISA S. BUNIN, M.D. Allentown, Pennsylvania

Analytical Report TITAN. laser & light technology. Cutera, Inc. By David M. Cauger, Contributing Editor. sept. oct

Full Face & Body Skin Rejuvenation

FACETITE: SUBDERMAL RADIOFREQUENCY SKIN TIGHTENING AND FACE CONTOURING

Hair Removal Using a Combination of Electrical and Optical Energies Multiple Treatments Clinical Study Six Months Follow up

Study of noninvasive Radiofrequency combined with Mesotherapy for face tissue tightening

designed to stimulate collagen

FaceTite : A Revolution in Targeting and. Reducing Facial Fat and Sagging without Undergoing a Facelift.

Safety and Efficacy of a Novel Diffractive Lens Array Using a Picosecond 755 nm Alexandrite Laser for Treatment of Wrinkles

Lux2940 Laser Advances Resurfacing. September/October 2007 Circulation 18,000

Tattoo Removal With an Electro-optic Q-Switched Nd:YAG Laser With Unique Pulse Dispersion COS DERM

Profitable. AESTHETIC SOLUTIONS with Focused Tri-Polar RF. More even, efficient dermal heating with shorter treatment times.

THE ROLE OF QUADRIPOLAR RADIOFREQUENCY IN AESTHETIC SURGERY AND MEDICINE

A fresher face. without surgery.

Evaluation of Safety and Efficacy of Variable Pulsed Light (VPL ) for the Treatment of Excess Hair in over 100 Volunteers

A fresher face. without surgery.

Creates younger skin. 1 Profoundly.

PLEASE SCROLL DOWN FOR ARTICLE

Light and Heat Energy (LHE ) Technology Review of a Novel Approach to Hair Removal

In the last decade Energy based aesthetic treatments, using light, radiofrequency and ultrasound have gained scientific

Science. Results. Trust.

ice Pretty. Cool. Virtually painless Proven safety record All skin types, even tanned skin Speed TM Applicator YAG Facial Tip ICE TM Tech

The legacy behind Q-switched technology. MedLite C

MICRONEEDLING DEVICE (SKIN ROLLER) ENHANCES SKIN S ABSORPTION OF PRODUCTS

NEW 3 Wavelengths and Resolve Fractional. The Complete Picosecond Platform

cellulite breakthrough Cellulite is a skin condition that appears body

Pearl Fusion Technique

elaser Ultra-Fast & Powerful Aesthetic Solution Science. Results.Trust.

REF Rev. 4

The SilkPeel System: Histology Study on the use of a Dermalinfusion System for Dermatologic Conditions. Lawrence S. Moy, MD February 15, 2005

GentleYAG Pro-U. Outstanding Results. Treating Multiple Indications. Upgradable. Science. Results.Trust.

Module 1. Introduction to Aesthetic Medicine: Nonsurgical

elase with Motif A New Picture in Pain Free Hair Removal Science. Results.Trust.

MAGAZINE. REASONS to Partner with SharpLight. Discover the latest and best in aesthetic innovation. Take a ride down our treatment optimization metro

Micro-Fractional & Whole Beam Technology Ablative Vaporization + Non-Ablative Coagulation Multiple Profitable Indications

Feel. Like A. New Person

Introducing the new LUMINA Laser and IPL platform

Laser Hair Removal: Results Of 2-Week Versus 6-Week Treatment Intervals

lumenis one the power of performance

Depth of Penetration by Wavelength (not to scale)

SISLOY FACELIFT SISLOY FACELIFT

a revolution in Q-Switched technology

Why treat pigmentation disorder in Asians? Softer and clearer skin is a key to looking younger and improved self satisfaction

Nd:YAG. Multi-Treatment System. Hair Removal. Photo Rejuvenation. Tattoos & Pigmented Lesions

SIGNIFICANTLY REDUCED TREATMENT TIME COMBINED TECHNOLOGIES FOR ENHANCED, LONG LASTING RESULTS CLINICALLY PROVEN IN EXTENSIVE STUDIES FAST, EASY TO

Feel. Like A. New Person

AESTHETIC PRECISION THE SAFEST AND MOST PRECISE LASER TREATMENT SOLUTION AVAILABLE FOR PIGMENTED LESIONS AND MULTI-COLOR TATTOO REMOVAL

Micro-fractional Laser Skin Rejuvenation : Enhanced Outcomes with Novel Multi-Modality and Multi-Wavelength Treatment Paradigms

STUDY. Skin Rejuvenation Using Intense Pulsed Light. A Randomized Controlled Split-Face Trial With Blinded Response Evaluation

Skin remodeling from the inside out CONSULTATION GUIDE

THE VENUS VIVA EXPERIENCE

LUCID QY/Q-PTP. 1064nm/532nm Q-Switched Nd:YAG Laser

Antiaging Treatments. Natalia Jiménez. Hospital Universitario Ramón y Cajal Grupo de Dermatología Pedro Jaén

TREATMENT OF ENLARGED PORES WITH THE QUASI LONG-PULSED VERSUS Q-SWITCHED 1064 nm Nd:YAG LASERS: A SPLIT-FACE, COMPARATIVE, CONTROLLED STUDY

An average of 6-10 treatments is recommended for best results.

The unique treatment that restores your skin s inner structure for a more youthful-looking appearance

High Intensity Focused Ultrasound System

LASER HAIR REMOVAL: SCIENTIFIC PRINCIPLES AND PRACTICAL ASPECTS

Think Outside the Eye. Treat Skin and Eyelid Inflammation. *

m3d Fractional Performance, All you desire, All in ONE! medaria Made in Italy The new Fractional pulsed crown Radio frequency About medaria

M22. All you need. All in one. LUMENIS.COM/AESTHETIC

One platform, endless solutions

Scanner Optimized Efficacy (SOE) Hair Removal with the VSP Nd:YAG Lasers

a noticeable difference in tattoo removal

Be an artist of the new era.

Illuminating Medical Aesthetics: Shining a Light on Low-Level Light Therapy In the Medical Esthetic Practice. Sam Shatkin, MD

OPT SHR IPL. Skin & hair treatments. A must for patient to enjoy perfect skin without pain. Big spot size with 20HZ fast speed.

M22. All you need. All in one. LUMENIS.COM/AESTHETIC

Be an artist of the new

PROFILE TM modular, multi-application aesthetic laser platform. The profile of precision.

4817 E Douglas, Suite 200 Wichita, KS Fax

M22. All you need. All in one. AESTHETIC.LUMENIS.COM

DERMATOLOGISTS DEBUNK MYTHS, OFFER ADVICE FOR CONDITIONS THAT HIT BELOW THE BELT

R avishing. by E vis. FDA Cleared Class II Medical Device for the treatment of Full Face Wrinkles

Results Clinical Photography

Nanosecond-domain Q-switched lasers have been

PRESS MATERIAL. Contents: Appendix: Backgrounder Q-Med 2 Backgrounder RESTYLANE 3 Questions and answers 5 Recommended reading 7

Genesis Biosystems DermaFrac TM Training Test

INJECTING SCIENCE INTO YOUR BEAUTY

Study of Very Long-Pulsed (100 ms) High-Powered Diode Laser for Hair Reduction on All Skin Types

Unique Technology Transforms RF-Based Microneedling. THE Aesthetic Show 2016 Preview Feminine Rejuvenation Update Most Influential Physicians

Through non-surgical procedures we can target facial concerns such as fine lines and wrinkles, lost volume, skin laxity, sun damage and scarring.

Collagen

Zeolight RF manual. Introduction. 2 Getting Started 3 Operation. 4 Operation Steps 5 Skin care after treatment 9 Maintenance of machine 9

SYNCHRO QS4 MEDICINE AND AESTHETICS SYNCHRO QS4. Maximum Results and Safety in Treating Multicolored Tattoos and Pigmented Lesions

Clinical Studies Confirm Superior Tattoo Clearance with PicoSure

EYEBROW MID FACE JAW LINE PATIENT SELECTION NECK

Effective epilation of white and blond hair using combined radiofrequency and optical energy

Evaluation of human allogeneic collagen gel for correction of nasolabial folds using non-invasive measurement techniques

Instructions for Use DO105625B

It is under the author s own responsibility

Transcription:

Infrared Technology for Skin Tightening A Hot Topic Utilizing Deep Dermal Heating Dr. Betty Czajkowsky, M.D., Nov. 2012 M.D. Sharplight s Medical Advisor Introduction A non coherent, selectively filtered IR (infrared) device emitting infrared light in multi-second cycles has been developed with the intention to provide dermal heating. Water, as the target chromospheres, allows uniform heating of the targeted skin tissue volume. A tailored wavelength spectrum from 850 to 1,750 nm nm on one hand sufficiently absorbed by intracellular and extracellular water allows a penetration depth of 5 mm into the skin which is ideal for targeting the reticular dermis. A multi second exposure is used with sufficient energy to create the desired combination of time and temperature for collagen contraction. The epidermis is protected through contact cooling. This allows for heating of the treated tissue without epidermal damage. Collagen is a polymer that exists as a triple helix with chains held together by hydrogen bonds. These molecules are aggregated and organized as fibrils with tensile properties attributable to intermolecular cross-links. When collagen is denatured by heat, the intra molecular hydrogen bonds rupture and the triple helices unwind to produce a gel of random-coil molecules. Tissue tension in human skin increases because, although the fibers become shorter, the heatstable cross-links between molecules are maintained, thus increasing the rubber-elastic properties of the collagen polymer. The heat-modified tissues then undergo remodeling associated with fibroplasias and new collagen deposition. When denaturation is complete, further increases in temperature result in additional fiber shortening, probably because of peptide bond hydrolysis. The mechanism of collagen shrinkage has been described in detail. The temperature at which collagen shrinkage occurs is often quoted as 65 C. According to this equation, shrinkage of collagen depends on time, as well as temperature, and collagen contraction occurs at a variety of time-temperature combinations rather than at a specific temperature. That said, it has been suggested that for millisecond exposures, collagen shrinkage will occur only at temperatures exceeding 85 C, whereas for exposures of several seconds, shrinkage will occur at 60 to 65 C. Collagen contraction begins to occur at approximately 55 C. This is caused by the spread of heat to the deeper reticular dermis. The IR infrared spectrum is both predictable and easily understood based on the known coefficients to the target chromospheres of water. SLT uses a unique spectral profile between 850 nm to 1750 nm. This IR source outputs from 20J/ cm2 to 35J/cm2, based on the area being treated, resulting in heating at depths from 1-3 mm. The epidermal temperature is kept at a safe level of below 40 C by an integrated thermoelectrically cooled sapphire window which also assists in maintaining patient comfort during the treatment. This unique IR spectrum creates a dual clinical effect of immediate skin tightening together with long term new dermal collagen formation. The primary function of this device is tightening of skin laxity on the face, cheeks and neck areas. Pain levels are reported to be well tolerated. The device is also intended for smoothing of facial wrinkles as a result of the neocollagenesis phenomenon. 1

Materials and Methods An IR halogen lamp hand piece for the Sharplight Formax Plus and Omnimax devices has been tested on twenty (20) volunteers, all females, aged between 45 and 65, with various degrees of lax skin in the face, neck and arms. The twenty (20) volunteers received six (6) treatments, twice a week for 3 months. Standardized photographs were taken at baseline, and after the 6th treatment. 6 months follow-up visit was also assessed. Patient satisfaction scores were recorded at the final visit. Each session s data was recorded for future evaluation. Hand pieces come in 2 spot sizes: 3.4 cm² and 6.4 cm². Fluence values are up to 35 J/ cm². It quickly became clear that a greater amount of collagen denaturation can be induced with multiple passes, 3 or more, depending on the severity of the laxity of the skin. Passes are performed over the entire designated treatment area, with additional passes over the areas of more concern. The neck is treated directly in the sub mental area. At these settings, the procedure is very well tolerated. It is recommended to lower fluences over bony areas. These areas have been found to be especially sensitive in many patients and treatment of this area is often avoided.on certain more sensitive areas the fluences are usually lowered due to discomfort. If the patient mentions an immediate burning sensation after the pulse, a cold pack should be applied immediately to prevent tissue burns. Immediately after treatment, diffused mild erythema with slight edema is evident in the area, but it usually fades within 1 hour. Physicians are currently using IR in two distinct treatment approaches. One method is to use the highest tolerable fluences. The second method is to use lower fluences with a higher number of pulses in concentrated areas. Physicians are currently using IR in two distinct treatment approaches. One method is to use the highest tolerable fluences. The second method is to use lower fluences with a higher number of pulses in concentrated areas. In this comparative conclusion, IR is effective for the following reasons: 1. Greater safety profile, more predictable. 2. Equal or near equal in dermal heating capability. 3. Superior epidermal cooling method. 4. Scalable platform. Patient selection Best results are often seen in patients with a minimum of excess fat in the area of concern and with thinner skin that is easily moved with a gentle touch. Patient s should be able to tolerate the treatment with no more than a moderate level of discomfort. Treatments are commonly performed twice a month; every 3-4 weeks is also effective, but visible results are not as fast. Maintenance should be done every 6 months to keep the skin tightening results. usually fades within 1 hour. Redness and heat sensation lasting for about 30 minutes after the session SLT IR 6.4 handpiece. Also available with a 3.4 spot size. 2

Results At 1 month after the last treatment, 70% of the subjects exhibited moderate to significant improvement in skin laxity and skin texture of face and neck. Patients reported high overall satisfaction with the treatment. No serious complications were recorded. Face and neck had a positive subjective evaluation after 8 treatments. Patient satisfaction scores: Very satisfied 70% Satisfied 20% Not satisfied 10% Conclusion The IR treatment has demonstrated to be highly effective and safe for non-invasive face skin tightening. Quantitative and qualitative results were documented in the treatment of face and neck skin laxity and improved texture and of sagging of arms. Very high patient satisfaction was achieved. The procedure is easy to apply, involves no discomfort to the patient and requires no downtime whatsoever. Periodic maintenance sessions may be administered as required or desired by each individual patient. The availability of IR treatment significantly enhances the capabilities of Sharplight s Formax Plus and Omnimax devices, broadening its clinical indications to increase results of skin tightening. Treatment phases Full cycle lasts approximately 10 seconds. OFF Pulse Pre-Cooling, through the sapphire window is regulated at around 10 C, and is achieved without pressing the pedal. ON Pulse Dermal heating with infrared light, with simultaneous and continue epidermal cooling, is achieved with a continuous pressing the pedal. Treatment phases Full cycle lasts approximately 10 seconds. OFF Pulse Pre-Cooling, through sapphire window regulated at around 10 C, is achieve without pressing the pedal ON Pulse Dermal heating with infrared light, with simultaneous and continue epidermal cooling, is achieve with a continuous pressing the pedal Post-Cooling is achieved without pressing the pedal B/A PHOTOS Before Before After 8 sessions After 4 sessions 3

References 1. Clinical and histopathological results following TriPollar radiofrequency skin treatments. Kaplan H, Gat A. J Cosmet Laser Ther. 2009 Jun;11(2):78-84. 2. Nonsurgical nonablative treatment of aging skin: radiofrequency technologies between aggressive marketing and evidence-based efficacy. Atiyeh BS, Dibo SA. Aesthetic Plast Surg. 2009 May;33(3):283-94. Epub 2009 May 13. 3. Monopolar radiofrequency treatment of human eyelids: a prospective, multicenter, efficacy trial. Biesman BS, Baker SS, Carruthers J, Silva HL, Holloman EL. Lasers Surg Med. 2006 Dec;38(10):890-8. 4. Is topical anesthesia useful in noninvasive skin tightening using radiofrequency? Kushikata N, Negishi K, Tezuka Y, Takeuchi K, Wakamatsu S. Dermatol Surg. 2005 May;31(5):526-33. 5. Non-ablative skin tightening with radiofrequency in Asian skin. Kushikata N, Negishi K, Tezuka Y, Takeuchi K, Wakamatsu S. Lasers Surg Med. 2005 Feb;36(2):92-7. 6. Selective electro-thermolysis in aesthetic medicine: a review. Sadick NS, Makino Y. Lasers Surg Med. 2004;34(2):91-7. Clinical applications of radiofrequency: nonsurgical skin tightening Hodgkinson DJ. Clin Plast Surg. 2009 Apr;36(2):261-8, viii. 7. The nonablative radiofrequency for rejuvenation. Sukal SA, Geronemus RG. Clin Dermatol. 2008 Nov-Dec;26(6):602-7. 8. Tissue tightening: a hot topic utilizing deep dermal heating. Gold MH. J Drugs Dermatol. 2007 Dec;6(12):1238-42 Clinical, laboratory, and MRI analysis of cellulite treatment with a unipolar radiofrequency device. Goldberg DJ, Fazeli A, Berlin AL. Dermatol Surg. 2008 Feb;34(2):204-9; discussion 209. Epub 2007 Dec 17. 9. Bipolar radiofrequency in the treatment of dermatologic imperfections: clinicopathological and immuno histochemical aspects. Montesi G, Calvieri S, Balzani A, Gold MH. J Drugs Dermatol. 2007 Sep;6(9):890 6. 10. Nonablative cutaneous remodeling using radiofrequency devices. Alster TS, Lupton JR. Clin Dermatol. 2007 Sep-Oct;25(5):487-91. 11. Nonsurgical tightening of skin laxity: a new radiofrequency approach. Rusciani A, Curinga G, Menichini G, Alfano C, Rusciani L. J Drugs Dermatol. 2007 Apr;6(4):381-6. 12. Monopolar radiofrequency skin tightening. Abraham MT, Mashkevich G. Facial Plast Surg Clin North Am. 2007 May;15(2):169-77, v. 13. Skin tightening with a combined unipolar and bipolar radiofrequency device. Mayoral FA. J Drugs Dermatol. 2007 Feb;6(2):212-5. 14. The role of deep heating for noninvasive skin rejuvenation Dierickx CC. Lasers Surg Med. 2006 Oct;38(9):799-807. 15. Monopolar radiofrequency facial tightening: a retrospective analysis of efficacy and safety in over 600 treatments. Weiss RA, Weiss MA, Munavalli G, Beasley KL. J Drugs Dermatol. 2006 Sep;5(8):707-12. 4

16. Monopolar radiofrequency. Burns JA. Aesthet Surg J. 2005 Nov-Dec;25(6):638-42. Nonablative radiofrequency treatment of facial laxity. Fisher GH, Jacobson LG, Bernstein LJ, Kim KH, Geronemus RG. Dermatol Surg. 2005 Sep;31(9 Pt 2):1237-41; discussion 1241. 17. Multipass vector (mpave) technique with nonablative radiofrequency to treat facial and neck laxity. Finzi E, Spangler A. Dermatol Surg. 2005 Aug;31(8 Pt 1):916-22. 18. Current concepts in nonablative radiofrequency rejuvenation of the lower face and neck. Abraham MT, Vic Ross E. Facial Plast Surg. 2005 Feb;21(1):65-73. 19. Radiofrequency nonablative tissue tightening. Koch RJ. Facial Plast Surg Clin North Am. 2004 Aug;12(3):339-46, vi. 20. Improvement of neck and cheek laxity with a nonablative radiofrequency device: a lifting experience. Alster TS, Tanzi E. Dermatol Surg. 2004 Nov;30(11):1430; author reply 1430. 21. Non-surgical radiofrequency facelift. Narins DJ, Narins RS. J Drugs Dermatol. 2003 Oct;2(5):495-500. 22. The medical face lift: a noninvasive, nonsurgical approach to tissue tightening in facial skin using nonablative radiofrequency. Ruiz-Esparza J, Gomez JB. Dermatol Surg. 2003 Apr;29(4):325-32; discussion 332. 23. Circumference reduction and cellulite treatment with a TriPollar radiofrequency device: a pilot study. Manuskiatti W, Wachirakaphan C, Lektrakul N, Varothai S. J Eur Acad Dermatol Venereol. 2009 Jul;23(7):820-7. Epub 2009 Apr 8. 5

MRK-00064 WW rev 2 SharpLight Technologies Ltd. All rights reserved. Specifications subject to change without notice. SharpLight, DPC, Beamax, Formax, Omnimax, Bizmax, Formaxplus and the SharpLight logo are registered trademarks of SharpLight Technologies. All other brand or product names are trademarks of their respective holders. *Caution: federal law restricts this device to sale by or on the order of a physician. 33 Lazarov St., Rishon Le Zion 7565435, Israel. Tel: 972 (0)3 961 1969 Fax: 972 (0)3 952 8890 info@sharplight.com www.sharplight.com 6