Device Performance Quick Guide 1

Similar documents
DERMABOND PRINEO Skin Closure Systems Discussion Guide

Procedure 19 Changing A Clean Dressing. Procedure 20 Applying A Bandage. Procedure 21 Applying A Sterile Dressing

STACK UP. See how we. Compare Cardinal Health LiquiBand OCTYL Topical Skin Adhesive to other leading products.

Kurt Ortwig NP NorthShore University Health System Department of Emergency Medicine

octylseal Tissue Adhesive The Next Generation 2-Octyl Cyanoacrylate

Topical skin adhesive products designed for effective wound closure

History of Cyanoacrylates in Medicine

Learning Objectives. Sutures and Staples. Training for Healthcare Professionals. Suture and Staple Removal

1. Wounds may be left exposed with some ointment applied to the stitch line:

LEUKOSAN ADHESIVE MSDS No. 189

LESSON ASSIGNMENT. After completing this lesson, you should be able to:

#74 - CHANGING A MOIST TO DRY DRESSING (TEST)

Procedure 30 Collecting A Blood Specimen Using The Vacuum-Tube System. Procedure 31 Collecting A Blood Specimen Using A Needle And Syringe

Care of your skin. Introduction. What can you do to help? Step 1 - Hygiene. Patient Information

3M Medipore Soft Cloth Surgical Tapes. Commonly Asked Questions

PROBLEMS THAT CAN CAUSE EXTENSIONS TO BREAK DOWN

Clozex Skin Closures. General Healthcare Users Training Guide * The Closure Goal. Wound Assessment. The Patient Exam.

Absorbents. Absorbents

Ventricular Assist Device (VAD) Exit Site Care Guidelines

Liquid & Powder Enhancements Sculpted on a Tip

Holiday Twinkle Toes. Step-by-Step Guide

ALLEVYN Gentle Border Lite Advanced Foam Wound Dressings

3M Cloth Adhesive Tapes. Commonly Asked Questions

EST March Esthetician All Trades Specialized Manicures

WOUND CARE/DRESSING CHANGE EBS localized, EBS generalized intermediate, EBS rare others, KINDLER SYNDROME

Contraindications Pre and Post Instructions

LEUKOSAN SKINLINK MSDS No. 182

Atopic Dermatitis (Eczema) Allergy and Immunology Awareness Program

BodyBare AquaSmooth. Instruction Booklet. wet & dry epilator AP17SR. Please read these instructions carefully and retain for future reference.

Table 5: Detailed Infection Prevention and Control Procedures for Body Piercing. drape the piercing site.

HI-TEC Alginate Wound Care Dressing

Implanting an Adult Rat with the Single-Channel Epoch Transmitter for Recording EEG. November 21, Epoch ECG Systems- Available from BIOPAC

Buy The Complete Version of This Book at Booklocker.com:

How To Care for Wounds

PharmChek Drugs of Abuse Sweat Patch Training Manual

BODY PIERCING AFTERCARE:

Skin Care During Radiation Therapy

Texas Department of Licensing & Regulation Health & Safety Sanitation Standards Topic Definitions

Alamo Hills Advanced Aesthetics & Laser

(NATO STANAG 2122, CENTO STANAG 2122, SEATO STANAG 2122)

Implanting an Adult Mouse with the Single-Channel Epoch Transmitter for Recording Local Field Potentials (EEG & Neural Signals)

TopClosure Tension Relief System

GOAL GATHER SUPPLIES CHANGE YOUR DRESSING CALL YOUR HEALTHCARE PROVIDER:

Surgical Gown. Tongue Depressor. A disposable gown worn by medical staff during surgery. A thin, flat, wooden stick rounded at both ends

Table 6: Detailed Infection Prevention and Control Procedures for Tattooing and Micropigmentation. Use During Tattooing

The fight against infection starts at home.

Jeffrey S. Epstein, M.D., FACS. Pre and Post Operative Instructions for FUE Hair Transplants

Disposable Cartridge NOSE Piercing System

Revised May Appendix B Dressing Selection

EXTENSION AFTERCARE. by Inanch Emir. Overview. Skill Level. Technical Skills

Tips On Proper Instrument Cleaning, Handling and Maintenance!

Infection Prevention and Joint Replacement

Pre & Post (BBL)Laser Hair Removal Treatment Instructions

Dangerous Things DIY RFID Implantation Guide Written by Amal Graafstra

Upper lid blepharoplasty

Home Care for Your Wound Drain

HAIR CONTACT. Manufactured for Propia Co., Ltd Nishishinjyuku Shinjyuku Tokyo, Japan Made in Japan

please be sure medications to the sun. of sedation to If If to Your hair in grafts being discuss this to poor wound days after.

Endoscopic Brow Lift Post Op

BodyBare Diva. Instruction Booklet. facial & delicate area epilator AP14D. Please read these instructions carefully and retain for future reference.

Practical Ophthalmic Procedures Vol.3

Advice for patients after removal of a pilonidal sinus

Scar management. Patient Information Service. Southend University Hospital NHS Foundation Trust. Rehabilitation department Hand therapy

Synthetic Hair Care Natural Hair Care CARE INSTRUCTIONS

Pre Treatment Advice and Procedures

Sterilization A Training Module

ADVANCED WOUND CARE SL070450

Dressings Range Healthcare Ltd

SHELLAC Brand Application & Removal

Looking after your own feet

HAND HYGIENE QUIZ. 1. Why is hand hygiene so important? (1 point) a. It is one of the single most effective measures for

EPILATOR LE 8820 ENGLISH WITH INTERCHANGEABLE SHAVING HEAD

Creams and Lotions. Ointment/Special Creams. Soaps to be used With or Without Water

Wound Care.

3M Tegaderm High Performance. Foam Adhesive Dressing. Application. and Removal. Pocket Guide

Scar Revision and Skin Surgery

Brick winding technique

CREATIVE PLAY Gel Polish Application & Removal

Training Manual. For the Application, Removal and Transport of the PharmChek Drugs of Abuse Patch. (The Sweat Patch is For Professional Use Only)

Basic section perm winding

Battery compartment 2AA To Reach Stibbar for supplies on your Tattooer:

Service Manual _ (YY_MM_DD) Philips Consumer Lifestyle. SERVICE POLICY Product will be serviced for 3 years after End of Life.

MEDICATION AND INJECTION ADMINISTRATION EDUCATIONAL BOOKLET FOR OVULATION INDUCTION

Home Care for Your Wound Drain After Breast Cancer Surgery

EduCare Demo Skill Assessment Personal Cares

Natural skin care

Personal Care Caregiving Series: Volume 8

Coverings care guide PB

PMD Personal Microderm Device Manual Contents

Informed Consent For Facial Rejuvenation/Collagen Remodel

Revised 1/10. Copyright 2010 St. Jude Children's Research Hospital Page 1 of 5

Hand Hygiene & PPE Policy

Skin Care During Radiation Therapy

ENHANCED CONTACT AND DROPLET PRECAUTIONS PPE CHECKLIST. Trained Observer: Unit: Date: [ ] the floor. 2 Engage Trained Observer and Assistant [ ]

ELDT - EasyLiner EasyLiner Locking Liner

ACETOCAUSTIN 0,5 ml, Cutaneous solution

BRISA Gel Enhancements Sculpted on a Tip

BodyBare Perfection. Instruction Booklet. cordless epilator & shaver with manual precission tweezers AP17LTR

Range. AU-3528 Oct 16. Page 1

Chapter 25: Manicuring

Transcription:

Device Performance 1 Patient Selection DO NOT use on patients with known hypersensitivity to cyanoacrylate, formaldehyde, benzalkonium chloride, or pressuresensitive adhesive. Use of DERMABOND PRINEO System on patients with hypersensitivity to one of these components may lead to skin reaction. Do not use on mucosal surfaces or across mucocutaneous junctions (e.g., oral cavity, lips), or on skin that may be regularly exposed to body fluids or with dense natural hair (e.g., scalp). Wound The skin edges must be closely approximated prior to application of the mesh, so that no significant manual approximation is required during mesh application. When used in high-tension areas, ensure skin tension has been removed by application of another wound-closure device (e.g., sutures or skin staples) prior to application of DERMABOND PRINEO System, or ensure that the area will be immobilized during the skin-healing period. Knee Position the mesh so one half is on either side of the incision, ensuring that at least 1 cm of mesh extends from each end of the incision. Press gently to ensure intimate contact of the mesh to the side of the incision. Gently pull the mesh perpendicularly over the incision while adjusting with fingers or forceps to achieve skin-edge approximation, and affix the remainder of the mesh to the other side of the incision. Apply the liquid adhesive using short strokes and moving from one end of the mesh to the other, making sure that the mesh is saturated as the liquid adhesive is applied. Spread the adhesive smoothly and evenly over the entire length of the mesh using the flexible applicator tip. DO NOT APPLY A SECOND COAT. During a total knee arthroplasty, best practice is to apply the DERMABOND PRINEO System while the knee is at the same angle of flexion as the joint capsule closure, without relaxing the knee.

1 The application of DERMABOND PRINEO System requires thorough wound cleansing. Follow standard surgical practice for wound preparation before application of DERMABOND PRINEO System (i.e., cleanse, irrigate, debride, obtain hemostasis, and close deep layers such that there is no tension on the skin edges). The skin edges must be closely approximated prior to application of the mesh, so that no significant manual approximation is required during mesh application. When used in high-tension areas, ensure skin tension has been removed by application of another wound-closure device (e.g., sutures or skin staples) prior to application of DERMABOND PRINEO System, or ensure that the area will be immobilized during the skin-healing period. Pat the wound dry with dry, sterile gauze to ensure direct tissue contact for adherence of the mesh and the liquid topical skin adhesive to the skin.

1 Step 1 Remove the mesh patch from the mesh carrier and dispose of the mesh carrier. Step 2 Flatten the mesh patch at the crease gently. Place the mesh patch flat on a surface so the mesh is facing down. Remove the center paper liner by peeling from the tab while the patch is flat, with the mesh side facing downward. Step 3 Hold the mesh by the proximal (closest to you) corners of the backing paper, ensuring the pressure-sensitive adhesive will be on the mesh side that will be adhered to the patient s skin. Step 4 Position the mesh so one half is on either side of the incision, ensuring that at least 1 cm of mesh extends from each end of the incision. Press gently to ensure intimate contact of the mesh to the selected side of the incision. Gently pull the mesh perpendicularly over the incision while adjusting with fingers or forceps to achieve skin-edge approximation, and affix the remainder of the mesh to the other side of the incision. Step 5 Use sterile scissors to trim any excess mesh, if necessary. Remove the remaining paper backing/frames.

1 Ensure the mesh is in intimate contact with the skin prior to application of the liquid adhesive. The liquid adhesive should be applied over the mesh immediately after the mesh has been placed. Step 6 Activate the liquid adhesive applicator by twisting the purple dial until a snap is heard. Step 7 Position the applicator tip straight down and away from the application area. Pinch the tip of the applicator, and squeeze the flexible bulb one time. Once the pressure in the bulb is released, it will partly or completely fill with liquid topical skin adhesive. Step 8 Spread the liquid adhesive smoothly and evenly over the entire length of the mesh using the flexible applicator tip. Apply the liquid adhesive using short strokes and moving from one end of the mesh to the other, making sure that the mesh is saturated as the liquid adhesive is applied along the entire length. Step 9 The adhesive should also be applied slightly over the edge of the mesh, covering a small margin of surrounding skin. Any excess liquid adhesive can be wiped off quickly with sterile gauze. DO NOT APPLY A SECOND COAT. Although not necessary, a protective, dry wound dressing such as gauze may be applied only after the liquid adhesive has completely polymerized (approximately 60 seconds), and the DERMABOND PRINEO System is no longer tacky to the touch.

1 Once polymerized, DERMABOND PRINEO System provides a flexible microbial barrier with 99% protection in vitro for 72 hours against organisms commonly responsible for surgical site infections (SSIs). 2 Patients should be advised that DERMABOND PRINEO System will need to remain in place until the wound/incision is properly healed (typically 7 to 14 days). During this time, DERMABOND PRINEO System should be kept dry. If directed by the health care practitioner, the wound may be briefly wet in a shower or bath, if dried immediately thereafter by gently blotting with a soft towel. The wound should not be soaked or scrubbed. Patients should not swim or otherwise immerse the wound in water for prolonged periods. If a protective wound dressing is being used over DERMABOND PRINEO System, it should be replaced with a dry dressing after showering or bathing. Patients should also be instructed not to scratch, rub, or pick at the DERMABOND PRINEO System and reminded not to apply topical ointments, lotions, or liquids to the wound while DERMABOND PRINEO System is in place. This may loosen the DERMABOND PRINEO System, causing it to peel away from the skin before the wound has fully healed. Patients should be instructed not to engage in strenuous physical activity that may cause tension on the wound or cause perspiration to wet the DERMABOND PRINEO System.

1 DERMABOND PRINEO System is designed to naturally slough off, or it can be removed by following the removal instructions below. Gently grasp the edge of the DERMABOND PRINEO System at one end of the wound. If the edge of the device is still adhered to the skin, gently pick at the edge until it begins to peel away from the skin. Slowly peel the DERMABOND PRINEO System away from the skin along the line of the wound, close to the skin. Do not pull the mesh straight up from the skin. Use the other hand to stabilize the wound as the mesh is peeled off. If required, petroleum jelly may be applied to aid in removal. Any residual adhesive and/or dried wound exudate can be cleaned from the skin according to usual practice. Please refer always to the for Use / Package Insert that come with the device for the most current and complete instructions. References 1. for Use. 2 Ethicon Inc, 06TR071, Study Report for in vitro evaluation of microbial barrier properties of DERMABOND ProTape, Dec 2006, Data on File Ethicon Endo Surgery (Europe) GmbH Hummelsbütteler Steindamm 71 22851 Norderstedt, Germany www.ethicon.com Ethicon Endo Surgery (Europe) GmbH 2017, 072540-170509 EMEA