HKS909. Diode laser. User&Training Manual

Similar documents
BLS801C Intense Pulse Light. User&Training Manual

HKS817C Radio Rrequency

P-808. Hair removal- Faster, painless and better

BLS820 Intense Pulse Light Radio Frequency. User&Training Manual

P NM DIODE LASER HAIR REMOVAL SYSTEM. Beijing Sanhe Beauty S & T Co., Ltd

Q-Plus EVO. Q-Switched Laser Platform Tailored to Your Needs TECHNICAL SPECIFICATIONS RESULTS BEFORE / AFTER ACCESSORIES. Rx Only.

OLIVE. Top Hair Removal Diode Laser System

THE HIGH-TECH LABORATORY FOR HAIR REMOVAL EPILATION FACE BODY NOT FOR SALE IN THE U.S.A.

Portable IPL System. Principle and Application

OPT SHR IPL. Skin & hair treatments. A must for patient to enjoy perfect skin without pain. Big spot size with 20HZ fast speed.

SYNCHRO QS4 MEDICINE AND AESTHETICS SYNCHRO QS4. Maximum Results and Safety in Treating Multicolored Tattoos and Pigmented Lesions

AESTHETIC PRECISION THE SAFEST AND MOST PRECISE LASER TREATMENT SOLUTION AVAILABLE FOR PIGMENTED LESIONS AND MULTI-COLOR TATTOO REMOVAL

Discovery PICO Series

MORE PRO THAN EVER 2000W. High power DIODE LASER PLATFORM GUARANTEED QUALITY. by cocoon medical

Introducing the new LUMINA Laser and IPL platform

Q-Plus Series. Taking care of people, our masterpieces. Q-Switched Laser Platform Tailored to Your Needs. Aesthetics

THE UNMATCHED STARS FOR PROFESSIONAL HAIR REMOVAL. Brochure not for the U.S.

Q: Switch ND: YAG Laser Skin Care System Model SQ-2

a revolution in Q-Switched technology

FIBER OPTIC IRONING DIODE LASER EPILASION!

M22. All you need. All in one. AESTHETIC.LUMENIS.COM

THE UNMATCHED STARS FOR PROFESSIONAL HAIR REMOVAL. Brochure not for the U.S.

EXTREMELY POWERFUL AND COMPACT Q-SWITCH Nd:YAG LASER

M22. All you need. All in one. LUMENIS.COM/AESTHETIC

FIBER OPTIC IRONING DIODE LASER EPILATION!

Prosonic TM. 790 cc. Type trimmer. off. eco. normal. clean. intensive. high. auto select. low. empty. reset

ExQ-Laser. Q-Switched Nd:YAG Laser Therapy Systems

Sash Open Area Module (SOAM)

ICOOL. ICOOL--- First Rate Air Cooling system.

Prosonic TM. trimmer. off. eco. normal. clean. intensive. high. auto select. low. empty. reset

Springs of well-being

Hair Clipper. User's manual

elase with Motif A New Picture in Pain Free Hair Removal Science. Results.Trust.

Wrinkle Reducer. Attachment USER MANUAL

Series7. Series 7. trimmer. Series 7. off. sensitive. intensive. clean. high. low. empty. reset

One platform, endless solutions

HKS777. Cavitation+RF+Vacuum User&Training Manual

Series 7. Series7. trimmer. Series 7. off. sensitive. intensive. clean. high. low. empty. reset

SyncroPro. Type 5492 Type

INNATE ABILITY MOTUS AX. The New Era of Hair Removal. Hair Removal Benign Pigmented Lesions

Prosonic BS washable clean. trimmer. off. eco. normal. intensive. high. auto select. low. empty. reset

The skin is, in fact, protected by the capability that Epil kriolight. has, to keep the temperature constantly below 10 C, in order to

Premium Q-Switched Nd:YAG

The new MÖ Laser Nd Yag 532nm & 1064nm uses the latest generation Pico technology. Powerful trillions of a seconds laser energy to grind the pigment

Series cc. Series 7. Type Series 7. trimmer. Series cc. off. sensitive. intensive. clean. high. low. empty.

Series7. Series 7. trimmer. Series cc. off. sensitive. intensive. clean. high. low. empty. reset

Instructions for Use DO105625B

GentleYAG Pro-U. Outstanding Results. Treating Multiple Indications. Upgradable. Science. Results.Trust.

Be an artist of the new era.

SHR Beauty Equipment. User Manual

Series 5. Series cc. Type Series 7. trimmer. Series 7. off. 760 cc. sensitive. intensive. clean. reset

OBIS Galaxy. Fiber Input, Fiber Output, Eight Channel Beam Combiner FEATURES

R avishing. by E vis. FDA Cleared Class II Medical Device for the treatment of Full Face Wrinkles

LUCID QY/Q-PTP. 1064nm/532nm Q-Switched Nd:YAG Laser

The neov Perfect Nails without Medication. The neov surgical laser platform at 1064 nm

M22. All you need. All in one. LUMENIS.COM/AESTHETIC

Instructions for Use Model EP

MOTUS AY INNATE ABILITY. The All-In-One Simple Solution for Aesthetic Medicine and Dermatology

Use and Care Guide. Register Your New Product Today! IPL6000USA IPL6000COS

Science. Results. Trust.

CoolTec. CT6cc CT5cc CT4cc CT4s CT3cc CT2cc CT2s. Type 5676

OBIS Galaxy Integrated System

Anthélia technical data(4)

Electric Shaver User's manual

ComplexCity Q-Switched Nd:Yag

Can I remove the hair from my nipples? Absolutely, the flash represents no risk. Caution is advised on dark nipples.

Portable Picosecond Nd Yag Laser System

Type Syncro System Smart Logic

The legacy behind Q-switched technology. MedLite C

Phone No.:

E-light System PRODUCT DESCRIPION

Safety. Laser Safety Accessories. Accessories. Protective equipment for working safely with ALPHA LASER s open systems of laser class 4

Operating Instructions. Model No. ES-LF70. (Household) AC/Rechargeable Shaver. English 17

By Paul Aylett at 3:58 pm, Jul 16, 2012

We are where you are!

Welcome to SMOOTHSKIN BARE

Think Outside the Eye. Treat Skin and Eyelid Inflammation. *

Model #7650 Instruction Manual Patent Pending

What is Pico second laser?

USER GUIDE. powered by

washable start stop washable Contour 5897 charge

High power (600W) 808nm diode. Shall We THE Tango? Perfect Solution for Permanent Hair Removal

PULSED LIGHT HAIR REMOVAL

elaser Ultra-Fast & Powerful Aesthetic Solution Science. Results.Trust.

Q-Switched ND: YAG Laser Tattoo Removal Machine. Model: TITAN2. User Guide

The Perfect All-In-One Tattoo Removal Laser. Science Engineering Design Versatility Ease-of-Use Practicality

Hair Removal Using a Combination of Electrical and Optical Energies Multiple Treatments Clinical Study Six Months Follow up

DEEP FACIAL CLEANSING WITH MICRO-FOAM

7 Function Anti Aging and Skin Rejuvenation Device Safe for all skin types

Always be on the safe side.

A new generation of technology. For a new generation of patients. Elite MPX. Powered by MultiPlex

What is Pico second laser?

Unit B: Safety in Agricultural Mechanics. Lesson 2: Using Personal Safety in Agricultural Mechanics

Operating Instruction GENTLEray 982 Bleaching. Always be on the safe side.

SkinScience. Natural Skin Care In It s Purest Form. Now it can be used in the comfort of one s own home. SkinScience Co., Ltd.

Scanner Optimized Efficacy (SOE) Hair Removal with the VSP Nd:YAG Lasers

washable start stop washable Contour 5888

Advanced infrared laser technology. Model No.: EP Instruction Manual

7 Function Anti Aging and Skin Rejuvenation Device Safe for all skin types

Client Training Guide

Transcription:

HKS909 Diode laser

HKS909 Safety Guidelines The Following information is provided for the correct utilization of IPL Skin treatment system.the Information includes not only the accident protection regulations the products comply with,but also the effective regarding proper use of the products. 1)Electric safety regulation The EMC Directive 89/336/EEC amended by 92/31/EC &93/68/EECEN55015:2000+A1+A2/LUM200704025/ EMCEN61000-3-2:2000+A2/LUM200704025/EMCEN 61000-3-3:1995+A1+A2/LUM200704025/EMCEN61547: 1997+A1/LUM200704025/EMC 2)Material ROHS test2002/95/ec Restriction of use of certain Hazardous Substance in Electrical&electronics Equipment/ROHS. 3)Electromagetic radiation safety regulation LVD/ EN60601-1:2006/AGC10430904GZ05E3EMC/EN60601-1-2:2001+A1:2006/AGC10430904GZ05E1 4)ISO13485:2003 MEDICAL/33021200005459 5)ITC MEDICAL CE IPL SKIN TREATMENT SYSTEM belongs to a according to MDD directive,it designed according to EN 980:2003; EN 1041:1998; EN ISO 14971:2007; EN 60601-1-2:2007; EN 61000-3-2:2006;EN 61000-3-3:1995+A1:2001+A2: 2006; EN 60601-2-22:1996; EN 60601-1-4-1996+A1-1999; EN 60601-1:2006. 01

1.Laser Shaving HKS909 Use high-power laser to shave hairs, reduce hair length to 1/8 inches. If the hair is too long, it may produce carbon dust, so the handpiece should be cleaned regularly. Put the handpiece above the skin, turn on the switch, move laser around until all hairs are carbonized. Carbon reagent can be used to improve heat switch reaction. Notice that the handpiece may cause danger even when it is away from skin. 2.Laser Radiation After the hairs are shaved by razor, this step starts laser radiation. The skin should be fully cleaned, if there exists dirt, it can cause danger as well as reduce the efficacy. Put the handpiece above the skin, (the laser output should not touch the skin and hair, or it may damage the laser). Set laser pulse to 10 pulse/sec and turn on the laser move handpiece around, but do not repeat over ten times on one tissue(1/2 inch circle), 30 or more pulses on one tissue can cause serious burn hurt. Reactions can be seen from the beginning, it is various on different patients. 02

3.Product Information 1.PRODUCT INFORMATION APPLICATION *Hair removal *Pigmentation troubles HKS909 FEATURES *laser wavelength: 808nm *maximum output power: 2W *spot diameter: 1.5mm *energy density: 10-40j/cm2 *frequency: 1-12HZ *pilot beam wavelength: 650nm *pilot beam output power: 5mv *pilot beam spot diameter: <1mm *operating mode : pulse *duty ratio: 1:1 *input current: AC100-240V 50/60HZ *operating environment: *temperature: 5-40 *humidity: 80% *Certifications:CE/ROHS *weight:6kg *Package size:58*50*35cm 03

HKS909 4.Installation Alignment and operation procedures 4.1 Open the Package and checking all parts. Diode laser handle foot Switch Laser glasses Goggle 4.2 Connect well the diode laser probe socket to device. 4.3 Connect well the foot switch to Device. 04

3.Operate the Device HKS909 Socket for probe LED Key Switch Adjust energy and frequency Display Urgency 3.1. Turn the key on the key switch and urgency Buttom to power on the machine, and the led on the screen will display. 3.2. Press or to adjust energy of power. 3.3. Press or to adjust frequency of laser emit. 3.4. Press ON button and the machine will be get ready. 3.5. Aim the handpiece to treatment area, press the emit button on the handpiece, the laser will emit, release the button to stop emit. 3.6.The Handle buttom can adjust the energy and frequency. 3.7. When you finish your treatment, please turn back your key to power off the machine, the key should be keep by doctor. 3.8. Press emergency stop button to stop the working of machine in case of emergency. 05

4.Treatment procedure HKS909 4.1 Cleanse, shave, and towel-dry the skin, then wipe the area with a cool towel,for the best results, the hair should be no longer than 1 or 2 mm in length. Wipe the area with a cool towel before you use the Epila Home Laser Hair Removal Kit. This will help to keep your overall skin temperature down, so that you can endure the heat from the laser for a longer period of time. 4.2.Setting comfort level Select the highest setting that suits your personal comfort level. There are five levels to choose from Level 1 (low), Level 2 (low-medium), Level 3 (medium), Level 4 (mediumhigh) and Level 5 (high). The Level 5 is most effective for hair removal but also the most painful.between probe to Skin is around 2-3cm. 4.3.Apply and over laser treatment Apply the Diode laser to the area of the skin you want to treat. Wait for the beep, then reapply by slightly overlapping the previous area. If there are a buzzing noise indicates that it failed, and you must retreat the area. Use the system for no longer than 30 minutes at a time. Take a 5 minute break, soothe your skin. 4.4.Future treatments Since hair grows in cycles, not every hair can be treated at the same time. Keeping this in mind, you will need one laser treatment every other week for the first 3 months then one treatment per month for 3-5 months afterwards to achieve the best hair-free results possible. After eight months of treatment, the hair follicles will be disabled and the hair will not regrow. You can keep using Tria laser system until you find your skin completely hair-free and smooth. 06

HKS909 5.Our Device superiority 5.1.Whole ABS Plastic Mould. 5.2.It does not present any contagious risk 5.3.stable laser energy output 5.4.Good energy and effect 5.5.Super treatment effect We Are Looking for Sale agent over the world. 07