ROBOT PIN TOOL CLEANING AND LIQUID SAMPLE TRANSFER

Similar documents
KERATIN CONTAMINATION

Sterilization A Training Module

SureCast Handcast System For preparation of handcast mini gels for use with the Mini Gel Tank and XCell Surelock systems

StainEase Gel Staining Tray

WHAT IS GEL ELECTROPHORESIS?

WHOLESALE PRICE LIST Sales/Service: (800) Fax: (973) Order: Opening Orders Only

Wet/ Tank Blotting System

VisPRO 5 Minutes Protein Stain Kit

E-Blotter Operation. Technical Bulletin E-03 MATERIAL PROCEDURE

Maintenance Guidelines Scuba

zenithinteriors.com Epic MELBOURNE SYDNEY CANBERRA BRISBANE PERTH ADELAIDE AUCKLAND WELLINGTON SHANGHAI HONG KONG

TECHNICAL INFORMATION

Optiblot SDS-PAGE Gel

HAND CLEANER PROMOTION

PET Barrier Test PET- R- 02

Standard Laboratory Practice for Consumer Applied Pet Stain and Odor Removal Chemical Evaluation on Pile Yarn Floor Coverings

Tips On Proper Instrument Cleaning, Handling and Maintenance!

Maintenance Guidelines Bluff

Western Blotting Systems CAT NO:EPS-B0015 & EPS-B0016

Optiblot Non-Reducing Electrophoresis Kit

Cleaning Instructions for Humanscale Seating Products

Optiblot SDS-PAGE Gel

Copper Stain & Destain Kit for Electrophoresis Instruction Manual. Catalog Number

Stone & Tile Care Resource Guide

Chapter 25: Manicuring

Optiblot SDS-PAGE Gel

Lenis Needle-free Safety Syringe Device User Manual

Hand Hygiene & PPE Policy

Emergency Procedures Specific Biological Spill Clean-Up Guidelines

Table 6: Detailed Infection Prevention and Control Procedures for Tattooing and Micropigmentation. Use During Tattooing

LYMPHOCYTE ISOLATION

Prisma & Film Staining Workshop. Application Specialist Mea Pelkonen

Maintenance Guidelines Compound

Cleaning Information. Cleaning Codes W S

EXERCISE 8C - Lab Procedures

Maintenance Guidelines Stature

Maintenance Guidelines Bitmap

The Specialist's Free Guide to Stain Removal

Maintenance Guidelines Ellipsis

CosmoPage Dual Run & Blot System

We also have MIXED LASH TRAYs available in C-, J-, B-, and D-Curls. (C 0.05, 0.07, 0.15, 0.20 J 0.07, 0.15, 0.20 B 0.15, 0.20 D 0.15,

Epic zen ze i n thi h nt n er e io r rs io. rs c. o c m o

Hints & Tips for Stain Removal

TECHNICAL INFORMATION Adhesive-Side Powder Development Catalog Nos. ASP150, ASP50D, ASP50L, TRA20

DuPont StoneTech Professional Stone And Tile Care Resource Guide 2008/2009 EDITION

Clinical Environments Cleaning, Care, and Maintenance

Instrument Cleaning. Dental Clinics

Maintenance Guidelines Splay

LAB 3 CHARACTERIZING YOUR UNKNOWN BACTERIA AND USING MORE COMPLEX STAINS. Part I: Isolating Your Unknown Bacteria and Describing Colony Morphology

Mini Blot Module. For transfer of proteins using the Mini Gel Tank USER GUIDE. Online Specials. Catalog Number B1000

Please Read Before Applying General Directions: Note: You may want to print these for future use!

Comparative Proteomics Kit II: Western Blot Module Quick Guide

SECUROS Surgical. Instrument Care Guide. A guide to maintaining and protecting your surgical instruments

STANDARDIZED CLINICAL PROTOCOLS. Sterilization Protocols. Aravind Eye Care System 1, Anna Nagar, Madurai , Tamilnadu, India

Charging base. Trimming head (30mm) on charging stand. Main body unit. On/Off switch. Indicated light. Connecting jack Connecting jack

Series7. Series 7. trimmer. Series 7. off. sensitive. intensive. clean. high. low. empty. reset

Phenion FT Skin Model Histological processing Paraffin sections

ELDT - EasyLiner EasyLiner Locking Liner

Boat Maintenance. If you have an aversion to labor and don't like fixing things, you have no business owning a boat.

CHM111 Lab Physical Separations Grading Rubric

BIODEGRADABLE SCREEN PREPARATION CHEMICALS

Device Performance Quick Guide 1

Experiment #3. Physical Separations Candy Chromatography

CIRRUS AIRPLANE MAINTENANCE MANUAL

Bio-compatibility Requirements

Application Guide. Manual Applicators 16 Floor Coating Foam Pad, 18 Paint Tray, NylFoam Stain Pad, Foam Brush, Wiping Rags, Sponges.

Great System. New for Break Through Formula. Extremely Popular FOOD PLANT APPROVED PRODUCTS 20+ AVAILABLE IN ALL CATEGORIES

Clean-it Brick and Masonry

PROTOCOLS FOR ANATOMY/MICROMORPHOLOGY

This bulletin gives specific instructions for application of Avery Dennison translucent film to recommended flexible-face signage material.

Hand. Care. Hand Care. Contents. Hand Care order online at:

Stone & Tile Care Resource Guide

Prosonic TM. 790 cc. Type trimmer. off. eco. normal. clean. intensive. high. auto select. low. empty. reset

Series cc. Series 7. Type Series 7. trimmer. Series cc. off. sensitive. intensive. clean. high. low. empty.

REVOLUTION M SERIES MANUAL & PARTS GUIDE

2018 A&L Product Reference Guide

Exercise 6-D STAINING OF MICROORGANISMS ENDOSPORE STAINS, CAPSULE STAINS & FLAGELLA

BlephEx...A Revolutionary New Treatment for Blepharitis. Owner s Manual

BODY ART FACILITY INFECTION PREVENTION AND CONTROL PLAN GUIDELINE

EST March Esthetician All Trades Specialized Manicures

2009 Volkem Cleaning & Hygiene Solutions. Classic white 400ml Classic white 500ml Classic white 1300ml Classic white 1100ml Auto

SHELLAC Brand Application & Removal

Professional spotting guide from Prochem Europe

Prosonic BS washable clean. trimmer. off. eco. normal. intensive. high. auto select. low. empty. reset

Making a Bangle Bracelet using a Metal Core from Arizona Silhouette

ab Papanicolaou (PAP) Red Stain Kit (Cytology Stain)

SHEPROS. Baby Series BABY DISHWASHER - B-BD 001. Product Description:

Vertical Gel Electrophoresis System. Instruction Manual

Materials needed: MAYAMY long-term eyebrow styling set consisting of:

Procedures and Practices for Flexo News Inks

Best of Suite Style. bandeau baskerville domaine moxie stargaze stryker tom's garden tv land twirl

Biohazardous Waste. 1. Solid Biohazardous Waste (non-sharps) Storage

AIRCRAFT MAINTENANCE MANUAL

Durability Thanks to the unique technology, Viatera withstands most everyday stains, and is scratch and crack resistant.

Shellac. Application & Removal. Fingernails. Step-by-Step

Body Art Facility Infection Prevention And Control Plan Guideline

TECHNICAL DATA SHEET TECHNICAL DATA SHEET

INSTRUCTIONS FOR COLOUR

How to Use Guide. K o n j a c S p o n g e

Tips and Tricks - Quick Reference

Transcription:

OVERVIEW TECHNICAL NOTE 67B ROBOT PIN TOOL CLEANING AND LIQUID SAMPLE TRANSFER There are several key steps in the successful use of pin tools: 1. The first and most important step is to start with clean pins. It is strongly recommended that V&P s specially developed VP 110 Pin Cleaning Solution is used at the beginning and end of each day to keep the pins clean. http://www.vp-scientific.com/v&p_pincleaner.php 2. Another key step is blotting onto a lint-free blotting material after delivery to the last daughter (recipient) plate and between wash solutions. Blotting greatly reduces carry-over. Blotting with lint-free blotting paper ensures that the pins do not pick up lint which will affect the volume transferred. V&P carries several different formats of Lint-Free Blotting Media: http://www.vp-scientific.com/blotting_membranes_wicking_papers.htm 3. Three wash solutions are recommended. The wash solution in the first reservoir will depend on the type of sample being transferred: a. For nucleic acid and biological (cell) transfers, use 10% bleach. b. For peptide and protein transfers, use 0.1% SDS. c. For small molecule compound transfers, use 50:50 DMSO:distilled H 2 O or other solvent. The second solution can be distilled H 2 O, or 100% alcohol if transferring small molecule compound libraries. Alcohol is recommended for the last wash solution due to its solvent characteristics and fast evaporation rate. NOTE: Always use distilled H 2 O, not deionized H 2 O in all pin tool applications. Long term exposure to deionized H 2 O will damage the stainless steel pins. V&P offers a variety of wash reservoirs: static, flowing, disposable and fountain reservoirs. Combination wash and blot reservoirs are also available. Check out the options at the following webpage: http://www.vp-scientific.com/wash_and_blot_stations_for_robot.php 4. When dipping the pins into mother (source) or daughter (recipient) plates and wash solutions, it is important to triple-dip into each solution. This mixes the liquid, loads and washes the pins to give more reproducible results. The pins should be completely removed from the liquid prior to each dipping to achieve maximum effect. 5. The speed of pin withdrawal from the liquid during the final dip will determine the volume transferred. The speed of the pins during the first dipping (washing/mixing) steps can be fast (2-8 cm/sec). Please see the following webpage for more information: http://www.vp-scientific.com/replacement_pins.htm#factors_volume_delivered 9823 Pacific Heights Boulevard, Suite T, San Diego, CA 92121 (858) 455-0643 Fax: (858) 455-0703 email: sales@vp-scientific.com

PROTOCOLS For Cleaning and Liquid Sample Transfer with V&P Scientific Robot Floating Pin Tools THREE CLEANING/TRANSFER PROTOCOLS: I. Routine or Daily Cleaning (page 2). i. Before starting an experiment and after finishing an experiment. II. Liquid Sample Transfer and Cleaning Between Transfers (page 3). i. Example of liquid sample transfer protocol from one mother plate to one daughter plate. ii. Recommended cleaning after sample transfer for prevention of sample cross-contamination during an experiment. III. Heavy Duty Cleaning for Neglected Pin Tools (page 4). i. When the pins have a buildup of material after extensive use without cleaning. Appendix 1. V&P Scientific Pin Tool Cleaning Accessories (page 5). I. ROUTINE OR DAILY CLEANING: Before starting an experiment and after finishing an experiment. A. Set up three wash reservoirs: Use VP 540-1 Wash Reservoirs or other appropriate reservoirs. 1. Fill wash reservoir #1 with 1:5 dilution of VP 110 Pin Cleaning Solution (please see Technote 40 for more information about VP 110). 2. Fill wash reservoir #2 with distilled H 2 O. 3. Fill wash reservoir #3 with alcohol (ethanol, isopropanol or methanol). 4. Adjust the level of wash solution in each reservoir as follows (example volumes are for VP 540-1): a. The first reservoir should wash slightly higher on the pins than the high water mark which results from dipping into microplates during an experiment (195 ml). b. The second wash reservoir should be slightly higher than the first reservoir (200 ml). c. The third wash reservoir should be slightly higher than the second reservoir (205 ml). 5. Next to each wash reservoir place a VP 540DB Heavy Duty Blotting Station. B. Washing pins: It is critical for the tip of the pin to move up and down through the meniscus with each dip into the wash solutions. 1. Dip pins into a 1:5 dilution of VP 110 Pin Cleaning Solution 3 times through the meniscus. Blot pins on VP 540DB Blotting Station. 2. Repeat wash and blot with VP 110 Pin Cleaning Solution. 3. Dip into distilled H 2 O wash, 3 times through the meniscus. Blot pins on VP 540DB Blotting Station. 4. Repeat wash with distilled H2O. 5. Dip into alcohol wash, 3 times through the meniscus. Blot pins on VP 540DB Blotting Station. 6. Repeat wash with alcohol. C. Drying pins: If pin tool is cleaned while installed on a workstation, the pins can be air dried for a few minutes or dried over a fan or vacuum station for one minute. See this link for the VP 904 Pin Dryer: http://www.vp-scientific.com/pin_tool_robot.php#vp904. Solid pins do not need to be dried with a fan or vacuum if they are blotted as the alcohol will evaporate very quickly. Slot pins will require a little longer time to dry without a fan or air movement. V&P Scientific, Inc. 2 Technical Note 67B. Rev. 06/08

II. LIQUID SAMPLE TRANSFER AND CLEANING BETWEEN TRANSFERS: A. Set up three wash reservoirs in VP 540-1 Wash Reservoirs or other appropriate reservoirs: 1. Wash solution in reservoir #1 will depend on the sample being transferred: a. For nucleic acid and biological (cell) transfers, use 10% bleach. b. For peptide and protein transfers, use 0.1% SDS. c. For small molecule and compound transfers, use 50:50 DMSO:distilled H 2 O. 2. Fill wash reservoir #2 with distilled H 2 O (or 100% alcohol, if transferring compound libraries.). 3. Fill wash reservoir #3 with alcohol (ethanol, isopropanol or methanol). 4. Adjust the level of wash solution in each reservoir as follows (example volumes are for VP 540-1): a. The first reservoir should wash slightly higher on the pins than the high water mark which results from dipping into microplates during the experiment (195 ml). b. The second wash reservoir should be slightly higher than the first reservoir (200 ml). c. The third wash reservoir should be slightly higher than the second reservoir (205 ml). NOTE: The VP 565 Reagent Dispenser can be used to maintain the liquid levels in the wash reservoirs. See http://www.vp-scientific.com/reagent_dispenser.htm for more information. 5. Place a VP 540DB Heavy Duty Blotting Station next to the daughter (recipient) plate and each wash reservoir. B. Example of liquid sample transfer from mother plate to daughter plate: 1. Dip pins into mother plate: a. Dip pins into mother plate to desired depth at maximum speed b. Move stage or pin tool (at maximum speed) so the pins are just barely out of the mother plate solution. c. Repeat dipping into mother plate two more times at maximum speed. d. Change the speed of the pin movement to one that results in the desired transfer volume. e. Raise pins out of mother plate. 2. Transfer pins to daughter plate: a. Dip pins into daughter plate to desired depth at maximum speed. b. Move stage or pin tool (at maximum speed) so the pins are just barely out of the daughter plate solution. c. Repeat dipping into daughter plate two more times at maximum speed. d. Change the speed of the pin movement to the same withdrawal speed as the mother plate. e. Raise pins out of daughter plate. f. Blot the pins on the VP 540DB Blotting Station at maximum speed so the pins float up 2mm. g. Let the pins dwell 2 seconds on the Blotting Station. C. Washing after each mother-to-daughter plate transfer: 1. Dip pins into first wash reservoir. a. It is critical that during each dip the tip of the pin is moved up and down through the meniscus. b. Move pins up and down through the meniscus 3 times. c. Blot pins on VP 540DB Blotting Station. 2. Dip pins into second wash reservoir. b. Blot pins on VP 540DB Blotting Station. 3. Dip pins into third wash reservoir. b. Blot pins on VP 540DB Blotting Station. 4. Allow pins to air-dry or use a drying station as mentioned below. D. Drying pins: If pin tool is cleaned while installed on a workstation, the pins can be air-dried for a few minutes or dried over a fan or vacuum station for one minute. See this link for the VP 904 Pin Dryer: http://www.vp-scientific.com/pin_tool_robot.php#vp904. Solid pins do not need to be dried with a fan or vacuum if they are blotted as the alcohol will evaporate very quickly. Slot pins will require a little longer time to dry without a fan or air movement. V&P Scientific, Inc. 3 Technical Note 67B. Rev. 06/08

III. HEAVY DUTY CLEANING FOR NEGLECTED OR INFREQUENTLY USED PIN TOOLS A. Clean pins in 65 o C Ultrasonic Cleaning Bath (Off-line) 1. Use 1:100 dilution of Micro90 Ultrasonic Cleaning Solution in an ultrasonic bath. 2. Immerse the lower 9 mm of pins in bath for 1 minute. 3. Rinse pin tips under hot, running tap water for 30 seconds. 4. Rinse pin tips with distilled H 2 O squirt bottle. a. If liquid has splashed on float plate, rinse float plate with distilled H 2 0 squirt bottle. 5. Rinse pin tips with alcohol squirt bottle. a. If liquid has splashed on float plate, rinse float plate with alcohol squirt bottle. 6. Blot excess liquid with VP 522 Lint-Free Blotting Paper that is on top of a stack of paper towels. The paper towels should be stacked so that the layers are even across the area where the pin tool will be blotted. 7. Dry pin tool briefly with portable hot-air dryer or continue with Cleaning with Pin Cleaning Solution below. B. Drying steps: Dry pins with portable hot-air dryer. 1. Hold pin tool in working position with pins pointing down. 2. Blow warm air, from below, up towards the pin tips. a. Move air from portable dryer across all of the pin tips. 3. Gently turn pin tool upside-down with pins pointing up. a. All of the floating pins should move through the float holes and rest on the top plate. b. Blow warm air, from the sides, between the float plates and top plate. 4. Turn pin tool back to working position with pins pointing down. a. If no pins remain stuck in the up position, then pin tool is ready to use. b. If a few pins move slowly or remain stuck in the up position, repeat blowing warm air from below and sides while gently rocking the pin tool upside-down to right-side up until all pins are moving freely. C. Clean pins in 1:3 dilution of VP 110 Pin Cleaning Solution. 1. Set up wash reservoirs as in Routine/Daily Cleaning (page 2) except that the VP 110 is diluted 1:3. Also set up an additional VP 522 Lint-Free Blotting Paper with a stack of paper towels. 2. Immerse the lower 9 mm of pins in VP 110. Move pins up and down through the meniscus 3 times. 3. Blot on VP 522 Lint-Free Blotting Paper. a. Check wet spots on Blotting Paper for uniformity. b. If spots are not uniform in size, continue to dip and blot a few more times until spots are uniform. 4. If spots are still not uniform after multiple dips and blots, slot pins may have dust or debris in the slots. a. Rinse the pin tips under hot, running tap water. b. Scrub the pin tips with VP 425 Pin Cleaning Brush or VP 426 Pin Tip Cleaning Pad. c. Rinse again with hot, running tap water. d. Repeat Step 3. e. If necessary, examine pins under a dissecting microscope to check for lint or debris on the pins or in the slots. 5. Dip pins into VP 110 again and blot to check spot size. 6. Once spot sizes are uniform, dip again in VP 110 by moving up and down through the meniscus 3 times. 7. Immerse the lower 9 mm of pins in VP 110. Soak pins in VP 110 for 30 minutes. 8. Rinse pin tips under hot, running tap water briefly. 9. Blot the pins briefly on piece of Lint-Free Blotting. 10. Dip pins into first wash reservoir. 11. Dip pins into second wash reservoir. 12. Dip pins into third wash reservoir. 13. Dry pins with portable hot-air dryer as described above. V&P Scientific, Inc. 4 Technical Note 67B. Rev. 06/08

APPENDIX 1 V&P PIN TOOL CLEANING ACCESSORIES: Our VP 110 Concentrated Pin Cleaning Solution is used to clean the pin tips, removing any buildup or residue. Dilute 1:5 before using. See http://www.vp-scientific.com/v&p_pincleaner.htm The VP 540DB Heavy Duty Blotting System is used to blot the pin tips after each daughter plate transfer and each wash station. It is a Nunc Omni Tray with a VP 540DB1 Super Absorbent Polypropylene Pad inside and a piece of 540D Lint-Free Blotting Paper on top of the pad. The heart of the system is the absorbent pad which will hold up to 27ml of liquid before it is saturated. The blotted liquid is transferred from the Lint-Free Paper to the Pad and a barrier holds it in the pad. This super absorbent pad means you don't have to change Blotting Stations frequently, just replace the VP 540D Lint-Free Blotting Paper at the end of each day (or as needed). See http://www.vp-scientific.com/wash_and_blot_stations_for_robot.php#vp540db The VP 540D Lint-Free Blotting Paper is cut to fit inside an Omni Tray for refills of the VP 540DB Heavy Duty Blotting System. See http://www.vp-scientific.com/blotting_membranes_wicking_papers.htm#vp540db The VP 540DB1 Super Absorbent Polypropylene Pad is cut to fit inside an Omni Tray for refills of the VP 540DB Heavy Duty Blotting System. See http://www.vp-scientific.com/blotting_membranes_wicking_papers.htm#vp540db The VP 540S Polypropylene Wash Reservoir is designed to hold the VP 426 Pin Cleaning Pad for gently cleaning debris or agar from pin tips. Includes an SBS feature on the bottom for workstation deck placement. See http://www.vp-scientific.com/pin_cleaning_accessories.php#vp540s The VP 426 Pin Cleaning Pad has soft, 4 mm long nylon bristles. It is placed in the bottom of the VP 540S Polypropylene Wash Reservoir for cleaning pin tips during the wash sequence between pin tool transfers. See http://www.vp-scientific.com/pin_tool_robot.php#vp904 The VP 425 Pin Cleaning Brush is used to manually keep the replicator pins clean so they will carry the same amount of liquid each time. 2.4 cm nylon bristles. See http://www.vp-scientific.com/pin_cleaning_accessories.htm The VP 425A Pin Cleaning Brush is used to manually keep the replicator pins clean so they will carry the same amount of liquid each time. For long pins, 8.5 cm nylon bristles. See http://www.vp-scientific.com/pin_cleaning_accessories.htm The VP 904 Pin Dryer is used to speed the drying time of the pins and decrease assay cycle time. See http://www.vp-scientific.com/pin_tool_robot.php#vp904 V&P Scientific, Inc. 5 Technical Note 67B. Rev. 06/08