PARTS LIST FOR WC-150-0ME3 WATER CANNON
Congratulations on the purchase of your new Mi-T-M Water Cannon! This parts listing has been complied for your benefit. You can be assured your Mi-T-M Water Cannon was constructed and designed with quality and performance in mind. Each component has been rigorously tested to insure the highest level of acceptance. The contents of this parts listing are based on the latest product information available at the time of publication. Mi-T-M reserves the right to make changes in price, color, materials, equipment, specifications or models at any time without notice. WARNING THIS IS A PROFESSIONAL Cleaning system. CAUTION SHOULD BE OBSERVED WHEN USING OR REPAIRING THIS UNIT! READ AND FOLLOW THE SAFETY WARNINGS LISTED BELOW BEFORE ATTEMPTING ANY REPAIRS ON THIS Water Cannon! SAFETY WARNINGS 1. Serious injury or death could occur if the Water Cannon (Power Supply) is not properly grounded. Your Water Cannon is powered by electricity and may cause electric shock or electrocution if not installed properly. Installation to this unit, including all electrical connections, must comply with all local, state and national codes. Any electrical wiring or repairs performed on this Water Cannon should be done by Authorized Service Personnel in accordance with National and Local electrical codes. 2. NEVER alter or modify the equipment. Use only genuine Mi-T-M parts for repair of your Water Cannon. Failure to do so can cause hazardous operating conditions and will VOID warranty. 3. Know how to stop and bleed pressures quickly. Be thoroughly familiar with controls. Do not operate without protective gear. Follow the maintenance instructions specified in your operator's manual. 4. Before servicing, ALWAYS shut off the water and the unit. NEVER assume the Water Cannon is safe to work on just because it is not operating. It could restart at any time! ALWAYS disconnect from the power source. 2
Table of Contents MAIN ASSEMBLY...4 CENTRIFUGAL PUMP (3-2002)...6 CONTROL PANEL (208V/230V)...8 ELECTRICAL SCHEMATIC (208V/230V)...10 ELECTRICAL DIAGRAM (208V/230V)...11 WX-0003 VOLTAGE OPTION (460V)...12 WX-0003 ELECTRICAL SCHEMATIC (460V)...13 WX-0003 ELECTRICAL DIAGRAM (460V)...13 WC-150-0ME3 ACCESSORIES...14
MAIN ASSEMBLY WC-150-0ME3-051999-DCE 4
WC -50-0ME-05999-D C E MAIN ASSEMB LY REF. # D ESCRIPTION PART# QTY. REF. # D ESCRIPTION PART# QTY. REF. # D ESCRIPTION PART# QTY. Frame Assembly 5-04A0 25 Ni pple 24-02 49 Bushing 24-024 2 Bolt 27-028 4 26 Uni on 24-020 2 50 Tee 24-022 leveler Foot 20-0502A0 4 27 Nipple 24-020 5 Decal- Number 4-0968 4 Washer 28-002 20 28 Ball Valve 22-0289 2 52 Decal- Clear Laminate N/A 5 lock Washer 29-0008 8 29 Decal- Number 2 4-0967 2 5 Decal- Serial Number N/A 6 Bolt 27-08 4 0 Clamp (Includes -) 42-00 54 Decal- Data Plate N/A 7 Uni on 24-02 Bolt 27-007 55 Decal- Mi -T-M Stripew/ Logo 4-0725 8 Nipple 24-020 2 2 Clamps (See 42-00) n/a sep. 2 56 Logo- Mi -T-M Gold 62-0087 9 Tee 24-0225 Nut 0-055 57 Decal- Mi -T-M Stripe 4-0502 0 Nut 0-059 6 4 Union 24-0228 2 58 Decal- American Flag 4-052 Plumbing support Bracket 20-0504A0 5 Nipple 24-0208 2 59 Decal- Warning/Caution/Operation 4-0970 2 Edging *(One Foot Required) -0020 6 soleniod Valve 55-009 60 Control Panel assembly (see pg. 8) n/a sep. Centrifugal Pump -2002 7 Union 24-0227 6 Bolt 27-8898 5 4 Pipe 24-026 8 Nipple 24-0205 62 switch- Blue 2-0528 5 Decal- Number 4-0966 2 9 Decal- Number 4 4-0969 6 Switch- Red 2-050 6 Reducer Coupling 24-095 40 Ball Valve 22-0279 64 Switch- Stop 2-0608 7 Nipple 24-020 4 Clamp (Includes 42-44) 42-002 2 65 Legend- Stop 2-0609 8 Ball Valve 22-0288 42 Bolt 27-08 2 66 Electrical Cover 2-0605 9 Pipe 24-02 4 Clamp (See 42-002) n/a sep. 4 67 Switch- Start 2-0606 20 Bushi ng 24-092 44 Nut 0-059 2 68 Legend- Start 2-0607 2 Drain "T" 24-022 2 45 Filter 9-2002 69 Check Valve 55-887 22 Bushi ng 24-089 2 46 Nipple 24-0202 70 Filter Screen 9-2004 2 Bushi ng 2-0056 2 47 Condulet 2-0642 *Must Order in One Foot Lengths 24 Guage 22-0292 2 48 adjustable Flow switch 2-064 5
CENTRIFUGAL PUMP (3-2002) 3-2002-070199-DCE 6
-2002-07099-DCE CENTRIFUGAL PUMP (3-2002) REF. # DESCRIPTION PART # QTY. REF. # DESCRIPTION PART # QTY. Motor- 5HP 2-004 9 O-ring 25-0487 2 O-ring 25-0484 0 Impeller 46-0855 O-ring sleeve 25-0485 Impeller Washer 28-06 4 seal sleeve 46-0865 2 square Key 4-0082 5 Bolt 27-895 8 Bolt 27-895 6 Bolt 27-8955 4 4 Case 46-0858 7 Bracket 46-086 Kit- Pump End (includes 2-14) 70-0285 8 Mechanical Seal 46-0860 7
CONTROL PANEL (208V/230V) WC-60AMP-ISO-051999-DCE 8
WC 60AMP ISO-05999-D C EE C ON TR OL PAN EL (208V/230V) REF. # D ESCRIPTION PART# QTY. REF. # D ESCRIPTION PART# QTY. Swi tch- Start 2-054 24 Timer 2-04 2 Swi tch- Stop 2-060 25 Base socket 2-02 Legend- Start 2-062 26 Relay 2-020 4 Legend- Stop 2-06 27 Over load Relay 2-0490 5 Control Box 2-04620 28 Cable 2-002 5 6 Bolt 27-8898 29 Mounting Base 2-062 6 7 Nut 0-022 2 0 Decal- 208 Volt 4-0896 8 Control Panel 20-0507A4 - Decal- 230 Volt 4-0895 9 D ecal- Phase 4-0965 Bolt 27-890 2 0 D ecal- Ground 4-0889 2 Terminal Block 2-064 Din Rail *(One Foot Required) 2-06 Decal- Terminal Strip -0 4-0958 2 Washer 28-000 7 4 Decal- 24 Volt 4-0894 Washer 28-009 5 Conduit- Straight 2-0255 4 Bolt 27-885 9 6 Conduit- Flexible *(Two Feet Required) -025 5 Power Distribution Block 2-06 7 Heat shrink 2-029 6 Terminal Block anchor 2-066 2 8 Conduit- Straight 2-0488 7 Terminal Block End 2-067 9 Conduit- Flexible *(Two Feet Required) 2-0486 8 Terminal Block 2-065 40 Conduit Elbow 2-0487 9 Transformer 2-068 4 Washer 2-060 2 20 Fuse- 600 Volt 2-0469 2 42 Conduit- Flexible *(Four Feet Required) 2-025 2 Fuse- 125 Volt 2-069 4 Conduit Elbow 2-0254 2 22 Contactor 2-0598 *Must Order in One Foot Lengths 2 Base socket 2-05 9
ELECTRICAL SCHEMATIC (208V/230V) WC-SCHEMATIC-A-042600-JJ 10
ELECTRICAL DIAGRAM (208V/230V) WC DIAGRAM-A-042600-JJ 11
WX-0003 VOLTAGE OPTION (460V) WX-000-06099-D C E WX-0003 VOLTAGE OPTION (460V) REF. # D ESCRIPTION PART# QTY. Terminal Block anchor 2-066 2 2 Terminal Block End 2-067 Terminal Black 2-065 4 Transformer 2-0 5 Fuse- 600 Volt 2-025 2 6 Fuse- 250 Volt 2-02 WX-0003-060399-DCE 7 C ontactor 2-0597 8 Over load Relay 2-048 9 D ecal- 460 Volt 4-0898 12
WX-0003 ELECTRICAL SCHEMATIC (460V) WX-0003 ELECTRICAL DIAGRAM (460V) WC-SCHEMATIC-B-051999-DCE WC-DIAGRAM-B-051999-DCE 13
WC-150-0ME3 ACCESSORIES WC-150 ACCESSORIES-020999-DCE 14
WC -00 AC C ESSORIES-020999-D C E WC -100-0ME3 AC C ESSOR IES REF. # D ESC R IPTION PART# QTY. Hose 5-200 2 Nozzle- 60 PSI Twi st Shut Off 8-200 Ball Valve (Bale) 8-2007 4 nozzle- smooth Bore 8-2008 5 Hose Reel 50-200 15
Manufactured by Mi-T-M 8650 Enterprise Drive, Peosta IA 52068 563-556-7484/ Fax 563-556-1235 16