MicroVue C4d Fragment Safety Data Sheet Revision Date: October 2, Section 1 Product and Company Identification

Similar documents
MicroVue CICP Safety Data Sheet Revision Date: November 15, Section 1 Product and Company Identification

MicroVue Bb Plus EIA Safety Data Sheet Revision Date: November 15, Section 1 Product and Company Identification

Section 1 Product and Company Identification. Section 2 Hazards Identification

MicroVue DPD Safety Data Sheet Revision Date: November 15, Section 1 Product and Company Identification. Section 2 Hazards Identification

MicroVue BAP Safety Data Sheet Revision Date: June 8, Section 1 Product and Company Identification. Section 2 Hazards Identification

MicroVue YKL-40 Safety Data Sheet Revision Date: April 3, Section 1 Product and Company Identification. Section 2 Hazards Identification

MicroVue Helical Peptide Safety Data Sheet Revision Date: April 1, Section 1 Product and Company Identification

MicroVue Serum PYD Safety Data Sheet Revision Date: April 3, Section 1 Product and Company Identification. Section 2 Hazards Identification

C5a EIA Safety Data Sheet Revision Date: January 14, Section 1 Product and Company Identification. Section 2 Hazards Identification

SIGMA-ALDRICH. Material Safety Data Sheet Version 4.1 Revision Date 12/04/2012 Print Date 03/19/2014

: Buffer solution ph 4.0 (20 C) Product Safety - Americas Region

SIGMA-ALDRICH. Material Safety Data Sheet Version 5.1 Revision Date 12/03/2012 Print Date 01/23/2014

IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

SIGMA-ALDRICH. Material Safety Data Sheet Version 3.1 Revision Date 04/13/2011 Print Date 09/07/2011

May be harmful if inhaled. Causes respiratory tract irritation. Skin. May be harmful if absorbed through skin. Causes skin irritation.

SIGMA-ALDRICH. Material Safety Data Sheet Version 4.0 Revision Date 07/23/2010 Print Date 09/16/2011

MATERIAL SAFETY DATA SHEET 1. PRODUCT AND COMPANY IDENTIFICATION:

GELATIN SOLUTION, 5% ph 3.2

Component Classification Concentration Sodium carbonate CAS-No. EC-No. Index-No.

SIGMA-ALDRICH. Material Safety Data Sheet Version 5.6 Revision Date 05/30/2012 Print Date 07/08/2014

Safety Data Sheet 1. PRODUCT AND COMPANY IDENTIFICATION. Product name: Sodium hypochlorite solution (Bleach) Product Number:

Safety Data Sheet. 1. Product and Company Identification. 2. Hazards Identification. Version 3.0 Revision Date

SIGMA-ALDRICH. Material Safety Data Sheet Version 4.1 Revision Date 01/18/2011 Print Date 03/29/2011

CONGO RED, 0.5%, AQUEOUS

IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET

SODIUM CHROMATE, 10%

SAFETY DATA SHEET PHOSPHOMOLYBDIC ACID-ORANGE G SOLUTION

W ATSON INTERNATIONAL LTD

: Sodium phosphate dibasic

Safety Data Sheet. 1. Product and Company Identification. 2. Hazards Identification. Version 3.0 Revision Date

LITHIUM CARBONATE, 0.05% AQUEOUS

MATERIAL SAFETY DATA SHEET VERSION NO.: 1.0 DeNovix dsdna Broad Range Buffer MSDS DATE: 10/12/2015

LIFELINE CELL TECHNOLOGY MATERIAL SAFETY DATA SHEET

CRYSTAL VIOLET, 1% AQUEOUS

SIGMA-ALDRICH. Material Safety Data Sheet Version 3.1 Revision Date 01/17/2012 Print Date 07/03/2012

Section 1 - Chemical Product and Company Identification. Section 2 - Hazards Identification

GHS Classifications. Safety Data Sheet POTASSIUM HYDROXIDE. Health Hazards. Physical Hazards. Environmental Hazards

SIGMA-ALDRICH. Material Safety Data Sheet Version 4.3 Revision Date 01/05/2013 Print Date 01/14/2014

Safety Data Sheet GALLEGO S DIFFERENTIATING SOLUTION. GHS Classifications HEALTH HAZARDS. Section 1 - Chemical Product and Company Identification

Excelsior MS-700 Excelsior Modified Silane Wet Set Adhesive

SILVER NITRATE, 10% AQUEOUS

SAFETY DATA SHEET POTASSIUM PERMANGANATE, 1% AQ.

SILVER NITRATE, 5% AQUEOUS

SIGMA-ALDRICH. Material Safety Data Sheet Version 4.0 Revision Date 02/28/2010 Print Date 08/09/2011

SIGMA-ALDRICH. Material Safety Data Sheet Version 4.0 Revision Date 02/27/2010 Print Date 09/07/2010

Alizarin Red S, 1%, AQUEOUS ph 5.5

SIGMA-ALDRICH. Material Safety Data Sheet Version 5.0 Revision Date 12/17/2012 Print Date 11/19/2013

SODIUM BICARBONATE, 5% AQUEOUS

SIGMA-ALDRICH. Material Safety Data Sheet. 1. PRODUCT AND COMPANY IDENTIFICATION Product name : Hydrochloric acid solution

POTASSIUM FERROCYANIDE, 2%

May be harmful if inhaled. May cause respiratory tract irritation. Skin. May be harmful if absorbed through skin. May cause skin irritation.

SIGMA-ALDRICH. Material Safety Data Sheet Version 4.1 Revision Date 01/19/2012 Print Date 01/26/2012

SAFETY DATA SHEET LUGOL S IODINE (Weigert s Iodine)

GHS Classifications. Health Hazards. Physical Hazards:

Safety Data Sheet ACID FUCHSIN, 1% IN 1% ACETIC ACID

Material Safety Data Sheet POTASSIUM FERROCYANIDE

CAS-No. EC-No. Index-No. Concentration p-chlorocinnamic acid

SAFETY DATA SHEET Conforms with OSHA Hazard Communication Standard (CFR ) HazCom 2012

SAFETY DATA SHEET FERRIC CHLORIDE, 10%, AQUEOUS

MATERIAL SAFETY DATA SHEET Econix Silver Nanoparticles (AGPE)

Safety Data Sheet. (Choline Salicylate) Choline Salicylate DATE PREPARED: 6/26/2015. Section 1. Product and Company Identification

Material Safety Data Sheet

GHS07. H315 - Causes skin irritation. H320 - Causes eye irritation. H335 - May cause respiratory irritation.

Safety Data Sheet. Company: Ricca Chemical Company. 448 West Fork Drive Arlington, TX USA

monosodium salt hydrate

2-Amino-5-nitrothiazole

SECTION I PRODUCT & COMPANY IDENTIFICATION SECTION II HAZARD(S) IDENTIFICATION

SIGMA-ALDRICH. Material Safety Data Sheet Version 4.3 Revision Date 08/05/2011 Print Date 09/16/2011

SIGMA-ALDRICH. Material Safety Data Sheet Version 4.2 Revision Date 11/16/2012 Print Date 09/11/2013

IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

SAFETY DATA SHEET TOLUIDINE BLUE, 0.2% AQUEOUS

SAFETY DATA SHEET POTASSIUM HYDROXIDE 10%

CAS-No. EC-No. Index-No. Concentration Ethene, chloro-, homopolymer

MATERIAL SAFETY DATA SHEET

SAFETY DATA SHEET Woodstain Scarlet-Acid Fuchsin Sol n

SIGMA-ALDRICH. Material Safety Data Sheet Version 5.1 Revision Date 12/12/2013 Print Date 02/25/2014

SIGMA-ALDRICH. Material Safety Data Sheet Version 4.1 Revision Date 04/18/2011 Print Date 11/01/2011

SAFETY DATA SHEET. Ammonium Oxalate Solution Manufacture of other chemical products, professional, sc ientific, and technical activities. None known.

SAFETY DATA SHEET Phosphate Buffer, ph 6.5

SIGMA-ALDRICH. Material Safety Data Sheet Version 4.1 Revision Date 04/07/2011 Print Date 08/19/2011

YUFENG INTERNATIONAL CO., LTD Material Safety Data Sheet Version 4.0 Revision Date 02/10/2017 Print Date 03/10/2017

MATERIAL SAFETY DATA SHEET Revision Date: 16 MAR 2015

CAS-No. EC-No. Index-No. Concentration Isopropyl myristate

SAFETY DATA SHEET PONCEAU ACID FUCHSIN

Material Safety Data Sheet

SILVER FERN CHEMICAL

SAFETY DATA SHEET ALCIAN BLUE, 1%, Aqueous

Safety Data Sheet. Pictogram: 1. MATERIAL AND SUPPLIER IDENTIFICATION. HOSPECO Curtiss Wright Parkway Cleveland, OH TEL:(800)

Split! Carpet and Upholstery Cleaner SDS DATE: 5 /07 / 2015 SAFETY DATA SHEET

1. Identification of the substance/mixture and of the company/undertaking

TIGI Bed Head After Party Smoothing Cream SAFETY DATA SHEET. Product name : TIGI Bed Head After Party Smoothing Cream

Product: Surgical Instrument Cleaner and Lubricant Revision Date: 07/17/2015 SECTION 1 - IDENTIFICATION

SIGMA-ALDRICH. Material Safety Data Sheet Version 4.1 Revision Date 07/07/2011 Print Date 08/31/2011

Material Safety Data Sheet Version 2.0 Revision Date: 08/10/2015

GHS TSCA: No data available # Canoe Avenue

SIGMA-ALDRICH. Material Safety Data Sheet Version 3.1 Revision Date 04/07/2011 Print Date 08/30/2011

: MasonRE Heavy Duty Rust Remover

Product Name: CLEANSAFE 40

Transcription:

Manufacturer Information Quidel Corporation Phone: 1.800.874.1517 Web: quidel.com 2005 East State Street, Suite 100 Fax: 1.740.592.9820 E-mail: qehs@quidel.com Athens, OH 45701 Emergency #: 1.866.519.4752 Product Information Product Name: MicroVue C4d Fragment EIA kit (Catalog #: A008, A009) Intended Use: Components: Emergency Overview The MicroVue C4d Fragment Enzyme Immunoassay (EIA) for the quantitation of the C4d-containing fragments of activated C4 of Classical Complement Pathway. Cat: #A008: For In Vitro Diagnostic use. For export only. Not for sale or use in the United States or Canada. Cat. #A009: For Research Use Only in the United States. Not for use in diagnostic procedures. C4d Standards A E, Low Control (lyophilized), High Control (lyophilized), Coated Strips, Stop Solution, 20X Wash Solution Concentrate, Specimen Diluent, Substrate Diluent, Substrate Concentrate, C4d Conjugate and Hydrating Reagent. Kit Component OSHA Hazards Target Organs GHS Classification Stop Solution (<4% Oxalic Acid) Irritant Eyes and Skin 20X Wash Solution, Specimen Diluent, Hydrating Reagent (0.035% Proclin 300) GHS Classification and Label Elements Section 1 Product and Company Identification Section 2 Hazards Identification Skin Irritation (Category 2) Eye Irritation (Category 2) Irritant Skin Skin Sensitizer (Category 1) Component Pictogram Hazard Statements Precautionary Statements H315 Causes skin irritation. P264 Wash hands thoroughly after handling. Stop Solution (<4% Oxalic Acid) Warning H319 Causes serious eye irritation. P280 Wear protective gloves and safety glasses. P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. 20X Wash Solution, Specimen Diluent, Hydrating Reagent (0.035% Proclin 300) Warning Supplemental Hazard Statements H317 May cause an allergic skin reaction. P264 Wash hands thoroughly after handling. P303+P361+P353: IF ON SKIN (or hair): Remove immediately all contaminated clothing. Rinse skin with water. P333+P313: If skin irritation or rash occurs: Get medical attention. 1. Follow Universal Precautions when working with this kit. Refer to additional Universal Precautions information in Section 7, Handling and Storage. 2. Avoid release to the environment. Page 1 of 8

Section 3 Composition / Information on Ingredients Kit Component Chemical Name CAS # EINECS # Conc. (%) Component Volume Stop Solution Oxalic Acid 6153-56-6 205-634-3 <4 6 ml 1. 20X Wash Solution 2. Specimen Diluent 3. Hydrating Reagent Mixture for Proclin 300: 5-Chloro-2-methyl-2, 3-dihydroisothiazol-3-one; 2-Methyl-2, 3-dihydroisothiazol-3-one (3:1) 55965-84-9 -- 0.035 1. 2x50 ml 2. 50 ml 3. 25 ml Substrate Diluent Hydrogen Peroxide 7722-84-1 231-765-0 <0.1 25 ml Section 4 First Aid Measures General Advice Move out of exposure area. Consult a physician. Show this safety data sheet to the doctor in attendance, as necessary. If inhaled: In case of skin contact: In case of eye contact: If swallowed: Note to Physicians: Move the person to fresh air and support breathing as required. Wash affected area with soap and water. Seek medical advice if irritation develops. Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists, get medical attention. Never give anything by mouth to an unconscious person. Rinse mouth with water (do not swallow). Seek medical advice if irritation develops. Stop Solution: Do not induce vomiting. Treat symptomatically. Section 5 Fire Fighting Measures General Advice Only individuals properly trained and issued appropriate personal protective equipment should respond and attempt to extinguish a fire. Extinguishing Media: General Fire Hazards: Hazardous Combustion Products: Fire Fighting Equipment: For small fires, use dry chemical, water spray, carbon dioxide or alcohol-resistant foam. The components within this kit will not significantly contribute to the intensity of a fire. Firefighters should wear full protective gear when responding to fires. Page 2 of 8

General Advice Only individuals properly trained and issued appropriate personal protective equipment should respond and attempt to clean up a spill or release. Large spills of the solutions, controls or reagents contained within this kit are unlikely. Personal Precautions: Materials and Methods for Clean-Up: Recovery and Neutralization: Section 6 Accidental Release Measures Use personal protective equipment, including protective gloves and safety glasses when cleaning up small spills of the solutions, controls or reagents within this kit. Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Keep all unnecessary personnel away from the spill area. Wipe up with inert absorbent material (e.g., paper towel, etc.). Thoroughly wash the area with soap and water after a spill or release clean-up. Collect spilled material and clean-up supplies and place in sealed container for disposal. Refer to Section 13 for disposal guidance. Environmental Precautions: Contain spill to prevent migration to drains, sewers or open water sources. Discharge into the environment must be avoided. Specific Use: Refer to product specific package insert. Not for use by the general public. Precautions for Safe Handling As with all chemical and biological substances, avoid getting the components within this kit ON YOU or IN YOU. Wash exposed areas thoroughly after using this kit. Do not eat or drink while using this kit. This kit should be handled only by qualified clinical or laboratory employees trained on the use of this kit and who are familiar with the potential hazards. Universal Precautions should be followed when handling and working with this kit. Keep out of reach of the general public. Universal Precautions Section 7 Handling and Storage No known test method can offer complete assurance that product(s) derived from human blood, serum or plasma used in components of this kit will not transmit infectious agents. All blood products should be treated as potentially infectious; use universal precautions. Users should ensure the use of proper personal protective equipment (PPE), covering of any cuts or abrasions on the skin (hands), and follow standard protocols for the decontamination of work surfaces when testing has been completed. Always wash hands thoroughly after handling the components within this kit. Conditions for Safe Storage: Incompatibilities To maintain efficacy, store according to the kit specific Package Insert instructions. To maintain efficacy, store according to the kit specific Package Insert instructions. Section 8 Exposure Controls and Personal Protection Exposure Limits: for the specific components within this kit. Exposure Controls: Engineering Measures Personal Protective Equipment Respiratory Protection: Hand Protection: Use with adequate ventilation. None needed under normal conditions of use. Handle with appropriately rated chemical resistant gloves. Gloves should be inspected prior to use. Use proper glove technique to remove gloves to avoid contact with skin. Wash hands after handling the components within this kit. Page 3 of 8

Section 8 Exposure Controls and Personal Protection (cont d) Eye Protection: Skin and Body Protection: Hygiene Measures: Wear safety glasses with side shields or goggles to prevent eye contact. Use body protection appropriate for the task. A laboratory coat is recommended. Wash hands before and after use and at the end of the workday. Environmental Exposure Controls No special environmental controls are required. Section 9 Physical and Chemical Properties Characteristic Stop Solution 20X Wash Solution Specimen Diluent Hydrating Reagent Boiling Point ( C) N/A N/A N/A N/A Melting Point ( C) N/A N/A N/A N/A Specific Gravity (H 20 = 1) N/A N/A N/A N/A Vapor Pressure (mm Hg) N/A N/A N/A N/A Vapor Density (Air = 1) N/A N/A N/A N/A Evaporation Rate (Ether = 1) N/A N/A N/A N/A ph 2 6.1 to 6.6 Neutral Neutral Solubility in Water Soluble Soluble Soluble Soluble Appearance and Odor Clear liquid, mild odor Clear liquid, odorless N/A = Do data available Slightly brown liquid, odorless Clear liquid, odorless Section 10 Stability and Reactivity Characteristic Stop Solution 20X Wash Solution Specimen Diluent Hydrating Reagent Component Stability Stable Stable Stable Stable Hazard Reaction Potential Conditions to Avoid Materials to Avoid Hazardous Decomposition Products Page 4 of 8

Acute Toxicity Component Analysis LD50 / LC50 / Irritation ( for specific kit components) Chemical Name CAS # RTECS # Information Oxalic Acid 6153-56-6 RO2450000 Mixture for Proclin 300: 5-Chloro-2-methyl-2, 3- dihydroisothiazol-3-one; 2-Methyl-2, 3-dihydroisothiazol-3-one (3:1) Section 11 Toxicological Information 55965-84-9 Not available Oral LD 50 Rat 1080 mg/kg Inhalation LC 50 Dermal LD 50 Oral LD 50 Rat 53 mg/kg Inhalation LC 50 Dermal LD 50 Hydrogen Peroxide 7722-84-1 MX0887000 Oral LD 50 Rat 376 mg/kg Inhalation LC 50 2 g/m 3 (4-hr) Dermal LD 50 >2000 mg/kg Potential Health Effects: Stop Solution, 20X Wash Solution, Specimen Diluent, and Hydrating Reagent Skin Corrosion/ Irritation: Inhalation: May cause respiratory tract irritation. Serious Eye Damage / Irritation: Skin: May cause skin irritation upon contact. Respiratory or Skin Sensitization: Eyes: May cause serious eye irritation. Generative Cell Mutagenicity: Ingestion: May be harmful if swallowed. Carcinogenicity No component of this kit present at levels greater than or equal to 0.1% is identified as probable, possible or confirmed human carcinogen by the ACGIH, IARC, NTP or OSHA. Reproductive Toxicity Stop Solution: Possible risk of congenital malformation in the fetus (oxalic acid). Teratogenicity Specified Target Organ General Toxicity (GHS) Single Exposure (GHS): Repeated Exposure (GHS): Aspiration Respiratory Organs Hazard None anticipated under product use conditions. Signs and Symptoms of Exposure To the best of our knowledge, the chemical, physical, and toxicological properties have not been thoroughly investigated for the components contained within this kit. Synergistic Effects Additional Information Stop Solution: Substrate Diluent: Sensitization: Stomach Irregularities Based on Human Evidence (oxalic acid) Stomach Irregularities Based on Human Evidence (hydrogen peroxide) Contains a small volume of a very dilute, sensitizing preservative (Proclin 300). Though the potential for an allergic response is greatly reduced by the dilution, sensitization threshold is unknown; thus, handle accordingly. Page 5 of 8

Ecotoxicity Mobility in Soil Persistence / Degradability PBT and vpvb Assessment Bioaccumulation Section 12 Ecological Information Other Adverse Effects An environmental hazard cannot be excluded in the event of unprofessional handling or disposal. Avoid release to the environment. Waste Disposal Instructions Proclin 300 is very toxic to aquatic life with long lasting effects. Utilize appropriate personal protective equipment and spill control when handling wastes generated from using this kit. Do not discharge any of the solutions, reagents or controls into drains, water courses or onto the ground. Disposal of Product and Contaminated Packaging Section 13 Disposal Considerations Dispose of waste materials, unused components and contaminated packaging in compliance with country, federal, state and local regulations. If unsure of the applicable regulatory requirements, contact a licensed professional waste disposal service to dispose of this material. Section 14 Transportation Information U.S. Department of Transportation (DOT) International Air Transportation (IATA) International Maritime Dangerous Goods (IMDG) This kit is not regulated for transport. This kit is not regulated for transport. This kit is not regulated for transport. Regulatory Information U.S. Federal Regulations OSHA Hazards Stop Solution: Irritant Section 15 Regulatory Information 20X Wash Solution, Sample Diluent, and Hydrating Reagent: Sensitizer SARA 302 The following chemicals are subject to reporting levels established by SARA Title III, Section 302: Hydrogen Peroxide CAS #: 7722-84-1 Revision Date: 1993-04-24 SARA 313 The following chemicals are subject to reporting levels established by SARA Title III, Section 313: No chemicals in this kit are subject to the reporting requirements of SARA Title III, Section 313. SARA 311/312 Oxalic Acid CAS#: 6153-56-6 Acute Health Hazard, Chronic Health Hazard Proclin 300 CAS#: 55965-84-9 Acute Health Hazard Hydrogen Peroxide CAS #: 7722-84-1 Acute Health Hazard, Chronic Health Hazard, Reactivity Hazard Page 6 of 8

State Regulations Section 15 Regulatory Information (cont d) The following chemical(s) appear on one or more of the following state hazardous substances lists: Chemical Name CAS # CA MA MN NJ PA RI Oxalic Acid 6153-56-6 No Yes No Yes Yes No Mixture for Proclin 300: 5-Chloro-2-methyl-2, 3-dihydroisothiazol-3-one; 2-Methyl-2, 3-dihydroisothiazol-3-one (3:1) 55965-84-9 No No No Yes Yes No Hydrogen Peroxide 7722-84-1 Yes Yes Yes Yes Yes Yes California Prop 65: This product does not contain any chemicals known to the State of California to cause cancer, birth defects, or any other reproductive harm. Canadian WHMIS Classification (Raw Material) Chemical Name CAS # Classification Oxalic Acid 6153-56-6 D2A Very toxic material causing other toxic effects (teratogen) Mixture for Proclin 300: 5-Chloro-2-methyl-2, 3-dihydroisothiazol-3-one; 2-Methyl-2, 3-dihydroisothiazol-3-one (3:1) 55965-84-9 Hydrogen Peroxide 7722-84-1 D2B Toxic material causing other toxic effects (severe eye irritant) Additional Regulatory Information Safety, Health and Environmental regulations/legislation specific for the mixture: Not completed for the components contained within this kit. Chemical Safety Assessment: Not completed for the components contained within this kit. NFPA Kit Classification: Health Hazard (blue): 1 Fire Hazard (red): 0 Reactivity (yellow): 0 Special Hazards (white): None Page 7 of 8

Section 16 Other Information PREPARED BY: Quidel Corporation SUPERCEDES: March 2, 2017 12544 High Bluff Drive, Suite 200 San Diego, CA 92130 REVISIONS: Section 1, addition of Catalog #A009 and associated supporting text. Section 15, removed HMIS classification. The information above is provided in good faith. It is believed to be accurate and represents the best information currently available to us. However, we make no warranty of merchantability, fitness for a particular purpose or of any other type, expressed or implied, with respect to products described or data or information provided, and we assume no liability resulting from the use of such products, data or information. Users should make their own investigations to determine the suitability of the information for their particular purposes, and the user assumes all risk arising from their use of the material. The user is required to comply with all laws and regulations relating to the purchase, use, storage and disposal of the material, and must be familiar with and follow generally accepted safe handling procedures. In no event, shall Quidel be liable for any claims, losses, or damages of any individual or for lost profits or any special, indirect, incidental, consequential or exemplary damages of any kind, howsoever arising, even if Quidel has been advised of the possibility of such damages. SDA008002EN00 (10/17) Page 8 of 8