Installation Guide. Product Code: SFM800ORG. P: F: Page 1 of 13

Similar documents
BEFORE OPERATING THE UNIT, MUST CAREFULLY READ AND UNDERSTAND THIS MANUAL RETAIN THIS MANUAL FOR FUTURE REFERENCE IBEAR PEDICURE SPA OWNER S MANUAL

Owner s Manual. Maintenance for Pipeless (Sanijet ) 12, 13. Maintenance for Standard Pedicure Spa (Whirlpool Pump) 15, 16

Owner s Manual. Table of contents 2. Introuduction & Safty Standard 3. Important considerations 4. Identify Parts & Description 5.

KM-S824 Modern Salon Spa Pedicure Chair Plumbing Free

MAESTRO PEDICURE SPA OWNER S MANUAL

OWNER S MANUAL ECHO / VANTAGE BRAVO VISION MODELS

ECHO /VANTAGE ECHO PLUS /VANTAGE PLUS

Artesian Pedicure System

MAESTRO PEDICURE SPA OWNER S MANUAL

OWNER MANUAL PLEASE SAVE THIS MANUAL FOR FUTURE REFERENCE

PEDICURE SPA USER MANUAL

O W N E R S M A N U A L I N S T A L L A T I O N G U I D E

OWNER S MANUAL INSTALLATION GUIDE

Continuum Pedicure Spas

Simplicity /Simplicity Plus

Professional Manicure & Pedicure Kit

Model #7650 Instruction Manual Patent Pending

European Touch - Limited Conditional Warranty

L E N O X OWNER S MANUAL. Please read user s Manual thoroughly before using pedicure spa. Product of J&A Copyright 2010 by J&A USA Inc.

Genesis Spa. Technician Comfort. G e n e s i s Pedicure Spa

PETRA. User s Manual Please read user s Manual thoroughly before using pedicure spa. Pedicure Spa. Copyright 2010 by J&A USA Inc.

User s Manual Please read user s Manual thoroughly before using pedicure spa

User s Manual. Please read user s Manual thoroughly before using pedicure spa. USA Inc. Copyright 2010 by J&A USA Printed in USA

Important Safety WARNING

PEDICURE SPA USER MANUAL

Foot and Calf Massager Model Number: FCM1000

i-twin Trim Dual Blade Rechargeable Trimmer

LX / LXP EPISODE. Pedicure Spa. WHIRLPOOL PEDICURE SPA User s Manual. Please read user s Manual thoroughly before using pedicure spa

Operating Instructions

CERTIFICATE OF COMPLIANCE

Charging base. Trimming head (30mm) on charging stand. Main body unit. On/Off switch. Indicated light. Connecting jack Connecting jack

GENTLE SKINCARE & HAIR REMOVAL SYSTEM

Operating Instructions

INSTALLATION AND ROUGH-IN INFORMATION

Surface Materials Cleaning & Maintenance

Part No Revised: June Sno-King. Instruction Manual Model #1888. Cincinnati, OH USA

Operating Instructions

Haircut kit IMPORTANT SAFETY INSTRUCTIONS. DANGER Any appliance is. WARNING To reduce the risk PIECE

Instructions and Safety notices

Page 1 of 7. Hand-Held High Frequency C9220T

PrecisionCut Hair Clipper

PDOB-II-GRM-NSF Ice Shaver. Specially designed for making shaved snow! User s Manual. Brought to you by SAC Food Supplies

10,000 prize draw. Register online for HC5800 HC5600 HC5400. EXTRA year guarantee FREE rewards gallery

Sonic Skincare Cleansing System

POWERGLIDE TITANIUM FEATURES

CARE AND MAINTENANCE

Galleria area. North. West Richmond Ave. Houston, TX P. (713) F. (832) E.

YOU MAY SAFELY USE: Formula 409R Dow Tub and Tile CleanerR Mr. CleanR

L E N O X. Owner s Manual. Pedicure Spa WHIRLPOOL PEDICURE SPA. Please read user s Manual thoroughly before using pedicure spa

CoolTec. CT6cc CT5cc CT4cc CT4s CT3cc CT2cc CT2s. Type 5676

MUSTACHE GROWING A BEARD AND. the manufacturer-to trim your beard and. For the best trimming results, your beard

ShaveMaster II. Block Ice Shaver Instruction Manual Model #1005. Cincinnati, OH USA. Part No Revised June 1996

5-in-1 Styling Kit. Specially designed to create multiple styles with one powerful tool! Instruction & Styling Guide

Exfoliate, Enhance and Smooth. User Manual & Warranty Information Model ST257

Footsie Bath Spa Pedicure Tub

Clinical Environments Cleaning, Care, and Maintenance

PowerSeries Aqua. 10,000 prize draw. Register online for PR1350 PR1370. EXTRA year guarantee FREE rewards gallery

Operating Instructions. Model No. ES-LF70. (Household) AC/Rechargeable Shaver. English 17

Pedicure Spa Use & Care Manual

10,000 prize draw. Register online for FC2000. EXTRA year guarantee FREE rewards gallery

Operating Instructions

AT850. Always here to help you. Rechargeable Cordless/Cord Tripleheader Shaver. Register your product and get support at

POWER TOOL HAIR CUT KIT

R3150AU 2 YEAR WARRANTY. Use and Care Instruction Manual PLEASE READ PRIOR TO USE

Specially designed to create multiple styles with one powerful tool! Instruction & Styling Guide. 5-in-1 Styling Kit

CARE AND MAINTENANCE

HAIRCUT KIT. 2 YEAR WARRANTY HC1090 Series USE & CARE MANUAL. To register your product go to PLEASE READ PRIOR TO USE

Become a Clarisonic Preferred Customer SONIC SKIN CLEANSING. One Speed. One-Year Warranty

Hair Clipper. User's manual

TopStyler User Manual

GUIDE WALLS AND DOORS GENERAL CARE & CLEANING OF SOLUTIONS

Coverings care guide 1

Lenis Needle-free Safety Syringe Device User Manual

HAIRCUT KIT. 2 YEAR WARRANTY HC2000 Series USE & CARE MANUAL. To register your product go to PLEASE READ PRIOR TO USE

Part No Revised April Sno Konette. Instruction Manual. Deluxe Model #1002S Standard Model #1003S. Cincinnati, OH USA

UDATED JANUARY 2016 SPIRALS TEAK FURNITURE PRODUCT CARE WE STRONGLY RECOMMEND USE OF HIGH QUALITY FURNITURE COVERS

Caring for Staron Solid Surfaces

BLUSH STYLE COLLECTION

Operating Instructions & Warranty Information

SHAVER 7300 S7370. Always here to help you. Rechargeable Cordless Tripleheader Shaver.

HyperFlex Aqua. 10,000 prize draw. Register online for XR1430 XR1450 XR1470. EXTRA year guarantee FREE rewards gallery

Series7. Series 7. trimmer. Series 7. off. sensitive. intensive. clean. high. low. empty. reset

Care & Maintenance guide

Prosonic BS washable clean. trimmer. off. eco. normal. intensive. high. auto select. low. empty. reset

Operating Instructions and Service Manual

Pedicure CONTINUUM. Order Now: OPTION 4


Series 7. Series7. trimmer. Series 7. off. sensitive. intensive. clean. high. low. empty. reset

Rechargeable Cordless Tripleheader Razor 8060X

8270XL. Rechargeable Tripleheader Cordless/Cord Razor. Register your product and get support at

USER MANUAL. WATCH THIS SHORT VIDEO. The easiest way to learn how to get MAX style

ULTIMATE HAIRCUT KIT 2 YEAR WARRANTY HC5005AU USE & CARE MANUAL PLEASE READ PRIOR TO USE

TopStyler User Manual

Rechargeable Tripleheader Cordless/Cord Razor 8240XL 8250XL 8251XL. Model 8240XL. Register your product and get support at

AT920. Always here to help you. Rechargeable Cordless Tripleheader Razor. Register your product and get support at

GMT180WTPBCSC BEARD/MUSTACHE TRIMMER

Series7. Series 7. trimmer. Series cc. off. sensitive. intensive. clean. high. low. empty. reset

BodyBare AquaSmooth. Instruction Booklet. wet & dry epilator AP17SR. Please read these instructions carefully and retain for future reference.

Maintenance Guidelines Scuba

Instructions for Use & Warranty Information

Transcription:

Installation Guide PRODUCT #: SFM800ORG ITEM: Organic M800 Pipeless Pedicure Spa from SpaFinity BRAND: SpaFinity SOURCE FOR PURCHASE: SpaEquip Inc. 211 Wappo Ave Calistoga, CA 94515 (707) 737-1100 www.spaequip.com FEATURES: The SpaFinity M800 Organic features the "Stressless" chair by Norwegian designer brand Ekornes, and pipeless technology in a fresh new look. Clients will enjoy ultimate comfort with ergonomic chair adjustments for reclining, zero gravity, upright position, etc. The chair offers seamless back and forward movement and allows easy entry from either side for added convenience. An upgrade is available for matching stone manicure trays (spill and acetone resistant.) The Ultra Leather Fabric is available in multiple color choices and is as durable as it is beautiful - 200,000 rubs resistant in factory tests. Choose from more than 80 colors, to couple with the designer wooden base that features easy access panels. This special marine wood is treated with a tough water-resistant finish coat. Matching Stone deck (spill and acetone resistant) is also available. Your clients will love the Reflexology pedicure basin with a sensual stone pathinspired base. The Organic features an industry-leading Pipeless system for maximum hygiene, and comes with 2 pipeless motors for 100% sanitation, quick cleaning and easy maintenance. Includes one chromatherapy light, and an adjustable footrest in matching fabric. Oversized item - ships by Truck. SPECIFICATIONS: Dimensions: 59.25"L x 24.5" W (Plus arms) x 48"H Electrical: 115V AC, 60 Hz, 15 amp; 220V N/A Suggested Outlet: Requires dedicated GFCI protected circuit; Includes 9 ft., 16/3 power cord Plumbing: 1/2'' NPT hot & cold, Drain 1"dia. OD Notes: See detailed specifications Warranty: 2 Year Limited Warranty Certifications: UL Country of Origin: United States Installed By: Client's Contractor www.spaequip.com P: 707-737-1100 F: 707-737-1150 Page 1 of 13

Receiving and Inspection This product was completely water-tested, securely packaged and in good condition when delivered to the carrier. Immediately upon receipt, inspect the unit for any obvious damage BEFORE installing. Should the inspection reveal damage or defect, do not install the unit. SpaFinity s responsibility for shipping damage ceases upon delivery of the product in good condition to the carrier. It is the responsibility of the recipient to inspect the packaging for damage. Any damage claims must be filed with the carrier within 10 days from receipt of shipment. All returns will be refused unless accompanied by a Return Material Authorization (RMA) Form. Contact SpaFinity for required documentation at (866) 726-0324. For definitions of warranty coverage and limitations, refer to the published warranty information on page 26. Important Safety Instructions INSTRUCTIONS PERTAINING TO A RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS SAVE THESE INSTRUCTIONS WARNING: When using this unit, basic precautions should always be followed, including the following: 1) READ AND FOLLOW ALL INSTRUCTIONS 2) WARNING: Risk of accidental injury or drowning: Children or handicapped persons should not use pedicure spa without adult supervision. 3) WARNING: To avoid injury, exercise care when using a pedicure spa. 4) WARNING: Risk of electric shock: Do not permit electric appliances (such as a hair dryer, lamp, telephone, radio, or television) to be within 5 ft (1.5m) of this unit. 5) DANGER: RISK OF ELECTRIC SHOCK: This unit should be grounded. Connect only to a dedicated 2 amp. Circuit that is protected by a Ground Fault Circuit Interrupter (GFCI). A GFCI should be provided by the electrician and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, there is a possibility of a ground fault, or defective GFCI. DO NOT USE THE UNIT. Have the problem corrected by a qualified service representative or an electrician before using. 6) WARNING: Use the M800 Organic Pedicure Spa only for its intended purpose: a fill and drain indoor appliance for foot and ankle hydro massage. DO NOT use attachments not recommended by manufacturer. 7) RISK OF ELECTRIC SHOCK: Disconnect from the electrical supply before servicing. WARNING 1. DO NOT reach for any electrical object that has fallen into water. Unplug immediately. 2. DO NOT drop or insert anything into any jet opening. 3. DO NOT operate this unit without the complete jet assembly installed or without water filled 1 inch above the jets. 4. DO NOT overfill the basin. 5. DO NOT stand on or in the basin, or on the foot rest. 6. DO NOT leave this appliance unattended when in operation. 7. Keep the electrical cord away from heated surfaces. 8. Connect this appliance only to a properly grounded outlet. (See Grounding Instructions - Page 5) 9. To avoid injury, exercise care when entering or exiting the pedicure spa. 10. It is important that you clean and disinfect the jets and basin after every use. Unless thoroughly cleaned after each use, bath residue will buildup within the jets and on the surface area of any whirlpool pedicure spa, which can promote the growth of infectious bacteria. 11. Hydrotherapy should be pleasant and comfortable. Should you experience any pain or discomfort while using the pedicure spa, discontinue use immediately and consult your physician. 12. Consult your physician if you are diabetic, have poor circulation, or if any area of your feet or legs is inflamed, has an open wound or if you have any other questions about whether you should be using hydro massage equipment. 13. SpaFinity recommends a qualified plumber and electrician install your M800 Organic Pedicure Spa. 14. Water supply temperature to the M800 Organic Pedicure Spa MUST NOT exceed 106 F (41 C). Water temperature in excess of 106 F (41 C) may be injurious to users health. Check water temperature and adjust prior to use. INSTALLER / OWNER BEARS ALL RESPONSIBILITIES TO COMPLY WITH ALL STATE AND LOCAL CODES WHEN INSTALLING THIS PRODUCT. FAILURE TO COMPLY WITH THESE INSTRUCTIONS MAY VOID WARRANTY. 3 4 www.spaequip.com P: 707-737-1100 F: 707-737-1150 Page 2 of 13

Plumbing and electrical M800 Organic Pedicure Spa PLUMBING REQUIREMENTS Your M800 Organic Pedicure Spa was factory tested for proper operation and watertight connections prior to shipping. Before installation the bath must be filled with water and operated to check for leaks that may have resulted from shipping damage or mishandling. If leaks are detected, DO NOT INSTALL the unit. SpaFinity recommends only a licensed contractor and electrician install the M800 Organic Pedicure Spa. Recommended Plumbing Specifications: Water Supply 1/2 N.P.T. hot and cold, male pipe thread Maximum Water Pressure 125 PSI [ 8.8 kg/cm2 ] Drain Diameter 1 1/2 PVC Socket (female) INSTRUCTIONS PRIOR TO USE WARNING: When using electrical products, basic precautions should always be followed, including the following: 1. IMPORTANT: Read complete instructions before use. 2. The M800 Organic Pedicure Spa requires a 115 VAC, 50-60 Hertz, 2 Amp service and is provided with a 3 foot [ 1 m ] power cord with a NEMA 5-15P electric plug. It is required that the jets be connected to a circuit protected by a permanent or portable ground fault circuit interrupter (GFCI). Grounding is required. 3. Remove the M800 Organic Pedicure Spa from the carton and retain the shipping carton and packing material to reuse in case service becomes necessary. ELECTRICAL CONNECTIONS Connect only to a circuit protected by a Ground Fault Circuit Interrupter (GFCI). All electrical connections should be made by a licensed electrician. The M800 Organic Pedicure Spa obtains electrical service via a 3 foot [ 1 m ] power cord. The jets provide a ground lug connector, located on the controller, and require a #8 solid copper bonding wire to earth ground. ELECTRICAL REQUIREMENTS 1. Electrical service, compatible with NEMA 5-15P electrical plug, should be positioned such that it is accessible via the unit s 3 foot [ 1 m ] power cord. 2. The electrical service should be positioned so the unit s power cord does not contact the floor of the unit s enclosure. 3. The electrical service should be located such that the power cord can be easily unplugged prior to removal of the jets for service. GROUND LINE 1. Install a #8 AWG solid copper bonding conductor (ground wire) from the unit s lug connector to earth ground. 2. Neither the #8 AWG ground wire or the clamp used to attach the ground wire to a metal stake driven into the ground or to a copper plumbing pipe are included with the M800 Organic Pedicure Spa. Wood Chair Base Shrouds Stressless Client Chair Pedicure Spa Basin Pedicure Spa Basin Wood Shrouds Faucet / Sprayer & Mixing Valve Adjustable Foot Rest Command Pad 5 6 www.spaequip.com P: 707-737-1100 F: 707-737-1150 Page 3 of 13

Floor Drain Layout Dry Run Protection 9 3 /4 9 3 /4 IM PORTANT: BEFORE USE check the magnetic impeller rotor is properly installed in the case motor assembly. BEFORE USE make sure that water is filled to at least 1 above the jets for proper operation. DO NOT attempt to activate the M800 Organic Pedicure Spa without water present. TO RESET, unplug the system and wait 5 seconds, then plug back in again. 24 1 /2 12 1 /4 25 24 1 /2 12 1 /4 25 18 from wall 140 The M800 Organic Pedicure Spa is equipped with an advanced dry run sensor to ensure water is present for proper jet operation. When the motor is turned ON and no water is present, the motor will run in the no load condition for 30 seconds then shut off for 15 seconds. After 15 seconds the motor will turn back ON. If the motor does not sense a load after 8 seconds, it will shut off again for another 15 seconds. The motor will repeat this sequence a total of 10 times before going into standby mode. Resetting the motor requires cycling the main power to the motors OFF and then back ON. (unplug system and wait 5 seconds, then plug power supply back in again) 30 48 The Run-Dry sequence timing: 1) ON=30 sec OFF=15 sec 2) ON=8 sec OFF=15 sec 3) ON=8 sec OFF=15 sec 4) ON=8 sec OFF=15 sec 5) ON=30 sec OFF=15 sec 6) ON=8 sec OFF=15 sec 7) ON=8 sec OFF=15 sec 8) ON=8 sec OFF=15 sec 9) ON=8 sec OFF=15 sec 10) ON=30 sec OFF=Reset (system must be unplugged to reset) 17 1 /2 Safety Shutoff Sensor 24 1 /2 46 57 1 /4 5 slide travel The M800 Organic Pedicure Spa is equipped with a safety shutoff sensor for you and your clients safety. The jet assemblies must be properly installed for use and will not operate if not aligned or assembled correctly. 3o clock Run Position 9o clock Run Position Separator Plate Specifications: Sensor Magnets 7 Overall Dimensions: Dimensions: 55 3/8 [ 141 cm ] Length, 23 3/4 [ 61 cm ] Width, 45 1/2 [ 116 cm ] Height Max.Height:451/2 [116cm]fromfloortotop of head rest Min. Distance to back wall: 20 [ 50 cm ] from back of base Min. Distance to side wall: 28 [ 71 cm ] from center of drain Min. Distance for side-by-side mount: 56 [ 142 cm ] from drain to drain Electrical Service Requirements: 115 VAC, 50-60 Hz, 2 amp, dedicated GFCI 3 ft. (92 cm), 16/3 power cord included Recommended Water Supply: Hot / Cold: Floor mount installation - 1/2 N.P.T. Maximum Water Supply Pressure: 125 psi (8.8 kg/cm2) Outgoing Water / Drain Diameter: Polished chrome lift and turn drain Floor mount installation -1 1/2 PVC Socket (female) Operating Water Capacity: 4.5 Gallons (17 L) Water Flow Rate: 14 gallons (53 L) per minute Codes and Approvals: UL & CUL recognized components (motors and jets) ETL Listed The jet assemblies must be properly locked in run position at the 3 or 9 o clock position to operate. Jet Discharge Escutcheon Port The separator plate must be properly installed in the escutcheon to operate. 8 www.spaequip.com P: 707-737-1100 F: 707-737-1150 Page 4 of 13

1. Remove the M800 Organic Pedicure Spa from the shipping crate, and place on the floor. Slide chair back and remove the wooden chair base shrouds (2) by lifting up and out. 3. Remove the wood sink shroud by sliding it towards the front of the pedicure chair Lift lever to slide chair back 2. Remove screws (4) from the from the rear panel at the back of the M800 Organic Pedicure Spa, and slide the panel out. 4. Remove screws (4) from the rear panel at the back of the M800 Organic Pedicure Spa, and slide the panel out. 9 10 www.spaequip.com P: 707-737-1100 F: 707-737-1150 Page 5 of 13

5. Position the M800 Organic Pedicure Spa on the specific installation location. 7. Locate the mounting brackets at the front corner (1) and at the opposite rear corner (1) of the frame. Front mounting bracket (1) Rear mounting bracket (1) 6. Confirm that the M800 Organic Pedicure Spa is level and balanced on the floor. This is especially important if your installation is done on tile or uneven flooring. Adjust the front and rear chair legs (4) as required to level sink deck (use 3 level). Adjust mid chair legs (2) after leveling sink to contact floor. Tighten all lock nuts. 8. Loosen bolts and slide the mounting brackets down until they are flush with the floor. Retighten bolts to the frame. Mark the floor at the bracket holes (2). Move the M800 Organic Pedicure Spa out of the way, and drill installation holes (2). Note: Tie down fasteners are not included. Please consult your contractor for the best mounting option for your location. Rear adjustable legs (2) Mid chair adjustable legs (2) 11 Front adjustable legs (2) Adjustable leg close-up 12 www.spaequip.com P: 707-737-1100 F: 707-737-1150 Page 6 of 13

9. Place the M800 Organic Pedicure Spa back in the proper floor location and secure to the floor. 11. Connect the drain pipe to 1 1/2 PVC socket (female). Drain 1 1/2 PVC socket 10. Connect 1/2 N.P.T. faucet hoses (2 are provided) to the hot and cold water supplies. 12. Slide the rear wood panel of the pedicure bath pedestal out and connect a #8 AWG solid bonding wire from the lug connector on the pedestal metal frame to earth ground. #8 AWG ground lug connector 13 14 www.spaequip.com P: 707-737-1100 F: 707-737-1150 Page 7 of 13

13. Plug the pedicure bath 3 prong plug into a 115 VAC, 50-60 Hz, 2 amp, GFCI protected outlet, at least 4 [ 11 cm ] above the floor or in accordance with your local building or electric codes. Outlet not provided. Note: The pedicure bath is manufactured with a electronic control panel, and no remote switch or timer is necessary. 15. After the fill test is complete, press the hydrotherapy power ON on the control panel to test the hydrotherapy operation. Next, press the chromatherapy lighting power ON to test the chromatherapy lighting operation. Junction box to be stubbed to the floor, do not attach to M800 Organic Pedicure Spa surround Chromatherapy Lighting ON/OFF Hydrotherapy ON/OFF Plug unit into 115 VAC, 50-60 Hz, 2 amp, GFCI protected outlet Minimum 4 [ 11 cm ] above floor or in accordance with local codes Electronic Actuator 16. Once proper operation is confirmed, turn the power off. Slide the wood shroud back onto the M800 Organic Pedicure Spa. Secure screws (4) into the back of the wood surround. 14. Fill pedicure bath with water to 1 [ 3 cm ]above the jet bodies, and visually inspect the pedicure bath for leaks. Fill water to minimum 1 [3cm] above jets Slide the shroud back into place Secure screws (4) into the back panel 15 16 www.spaequip.com P: 707-737-1100 F: 707-737-1150 Page 8 of 13

17. Replace the rear panel into the back of the M800 Organic Pedicure Spa and secure screws (4). Operating Instructions HOWTOUSE 1. After the M800 Organic Pedicure Spa has been properly installed, fill the unit with water, at the desired temperature, one inch [ 3 cm ] above the jets. Fill water to minimum 1 [ 3 cm ] above jets 2. Verify that the M800 Organic Pedicure Spa s electrical cord is connected to a GFCI protected electrical outlet. 3. To start or stop the M800 Organic Pedicure Spa, press the Hydrotherapy ON/OFF button on the control panel. Press once for high, press again for low and press again for off. (elapse timer feature: 20 minutes.) Chromatherapy Lighting ON/OFF 18. Replace the wooden chair base shrouds (2) by installing them flush with each other on the wooden chair base Velcro pads. Hydrotherapy ON/OFF Electronic Actuator 4. Bath additives, including oil based products, can be used in the M800 Organic Pedicure Spa, since their residue can be easily cleaned. CAUTION: Use only low foaming additives, and do not use products that contain sand or silicates. 5. You should always be in a seated position when putting your feet or removing them from the pedicure bath. WARNING: NEVER STAND IN THE PEDICURE BATH BASIN. 6. Press the CHROMATHERAPY button on the control panel once to turn the Chromatherapy Light ON - The light will automatically change colors. To achieve and maintain a desired color Press the CHROMATHERAPY button repeatedly (slowly) until the desired color appears. Colors available: Shimmering Color Wash, Bright White, Aqua Blue, Ocean Blue, Soothing Violet, Shamrock Green, Fiery Red, Majestic Gold. (Elapse timer feature: 2 hours.) 7. To adjust the foot rest, lift foot rest vertically until it latches at the appropriate height for your client. To release the adjustable foot rest, raise the foot rest to the maximum height to release the latch, and the foot rest will return to the deck. Foot Rest 17 18 www.spaequip.com P: 707-737-1100 F: 707-737-1150 Page 9 of 13

Operating Instructions Operating Instructions 8. The Client Chair can rotate 140 degrees for easy access from either side. 10. To recline chair, rotate knobs (2) on both sides of chair arm supports and lean back. To lock the chair in the recline position, rotate knobs until locked. Rotate knobs on both sides of chair to recline or lock 9. To slide chair forward or back, lift lever up on the right arm support. Release lever to lock in position. 11. To completely recline chair, hold head rest and press chair back down until fully reclined. Once reclined, tilt chair headrest forward while maintaining the chair in the fully reclined position. Lift lever up to slide, and release to lock in place Recline chair back and tilt headrest forward 19 20 www.spaequip.com P: 707-737-1100 F: 707-737-1150 Page 10 of 13

Operating Instructions 12. Completely recline chair by pressing chair headrest down until chair back is in the fully reclined position. Cleaning And Disinfection IMPORTANT! TOTAL DISINFECTION REQUIRES TWO DISTINCT STEPS 1. Remove residue with thorough and effective cleaning. 2. Disinfection: Apply an EPA registered disinfectant, covering 100% of all surface areas for the required contact time, to kill bacteria, viruses and fungi. 1 2 3 PREPARATION & CLEANING a. Drain the bathing well of all water. b. Rotate the jet assembly to remove from jet case. c. Remove the magnetic impeller / rotor from jet case. d. Disassemble the jet assemblies (2 pieces each) and place them in the sink. Use a non-abrasive antibacterial cleaner to remove any visible residue - rinse with fresh water. e. Use a non-abrasive antibacterial cleaner to clean the bathing vessel, jet cases, drain stopper and overflow mechanism rinse with fresh water. DISINFECTION a. Spray the surface area of the jet assemblies and bathing vessel until thoroughly coated with an EPA registered disinfectant. b. Allow to set for the required disinfection contact period (refer to manufacturer s specifications) then rinse surfaces with fresh water. REASSEMBLE a. Dry the jet assemblies and bathing vessel. b. Reinstall the jet assemblies by aligning with jet case at 10 o clock position. Maintain even pressure and rotate jet assembly to securely lock in place at 3 or 9 o clock position. 3 o clock run position 9 o clock run position 10:00 preinstallation position *can also be aligned at 2, 4 or 8 o clock position IM PORTANT: Always refer to your state and local guidelines for cleaning requirements. NEVER USE abrasive cleaners on any surface area. After each use, disinfect the system with the recommended disinfection procedures for maximum sanitation. BEFORE USE check the magnetic impeller rotor is properly installed in the case motor assembly. BEFORE USE make sure that water is filled to at least 1 above the jets for proper operation. DO NOT attempt to activate the Pipeless Reflexology Pedicure Bath without water present. TO RESET, unplug the system and wait 5 seconds, then plug back in again. 21 Additional Notes M800 Organic Pedicure Spa system cleaning and disinfection takes approximately 5 minutes when using Dispatch Hospital Cleaner Disinfectant with Bleach. The M800 Organic Pedicure Spa does not require a fill and drain cycle during disinfection, for improved water conservation. For applications requiring quick cleaning between treatments, SpaFinity recommends a second set of clean jet assemblies for quick replacement. Recommended Cleaner / Disinfectant SpaFinity recommends the use of DISPATCH Hospital Cleaner Disinfectant with Bleach - EPA Reg. No. 56392-7; EST. No. 62801-MI-001. Kills bacteria and viruses in 1 minute and tuberculosis in 30 seconds. Available in 32 oz trigger spray and 64 oz refill bottle. 22 www.spaequip.com P: 707-737-1100 F: 707-737-1150 Page 11 of 13

Care And Maintenance BASIN, FAUCET AND DRAIN Approved Cleaners: Clean with a mild liquid detergent and warm water solution. For stubborn stains use Gel Gloss, Windex Spray, Glass Plus Spray. Recommended Disinfectants: Dispatch Hospital Cleaner Disinfectant. Paint, tar or other difficult stains can be removed with paint thinner, turpentine, or isopropyl alcohol (rubbing alcohol). Lightly wipe the stain with a clean cloth which has been moistened with solution. Blot the area with a dry cloth and allow to dry. To avoid discoloration, cleaners containing petroleum distillates must not remain on the surface. To avoid scratching and dulling of the surface, never use abrasive cleaners Minor scratches can be easily removed as the Pipeless Reflexology Pedicure Bath Basin are made of 100% Acrylic. Immerse 600-grit wet/dry sandpaper in water and lightly sand the area. Repeat sanding with 1000-grit wet/dry sandpaper and water. To restore the surface gloss, use Gel-Gloss (found at most hardware stores). If Gel-Gloss is not available use automotive rubbing compound followed by an application of automotive paste wax. Major scratches and gouges will require professional refinishing. Contact SpaFinity s technical service department for specific instructions at (866) 726-0324. CHAIR AND FOOT REST The M800 Organic Pedicure Spa comes standard with exceptionally durable commercial grade fabrics designed for high wear applications. Approved Cleaners: Spot clean with mild liquid detergent and warm water, and air dry. For stubborn stains use an alcohol-based solutions like Fantastik -409. Recommended Disinfectants: A 5 : 1 bleach solution. Dry cleanable by conventional methods using commercial dry cleaning solvent Ordinary dirt, smudges and water soluble stains, such as coffee, tea, juice, soft drinks, milk, beer, wine, and other can be removed with mild soap and water. Use a clean cloth or soft sponge to dab the stain with the solution. Remove the soap solution by wiping the area with a cloth and clean water. Dry with a soft lint-free cloth or towel. Very stubborn stains or non-water soluble stains can be removed with a mild solvent such as naphtha (lighter fluid, paint thinner). Lightly wipe the stain with a clean cloth which has been moistened with solvent. Blot the area with a dry cloth and allow to dry. Many ink and magic marker stains can be removed using a 50/50 solution of mild detergent and rubbing alcohol. Dab lightly with a cloth which has been moistened with solution. As the ink loosens, blot the area with a dry cloth. Repeat as necessary. Rinse with a cloth dampened in clean water, and dry with a soft cloth. Avoid using cleaners containing abrasives or bleach. Disinfectants can be used provided they are evaluated beforehand. The following products are NOT recommended for use on the M800 Organic Pedicure Spa foot rest and chair fabric: Coefoam, Coe Spray, Coe Foam Plus, Healthco Aerosol Foam Cleaner, Lysol, Lysol II, Lysol Professional, Asepti-steryl Aerosol, Procide ES, Cavicide, Sodium Hypochlorite Solutions (Chlorine Bleach), Alcohols such as Isopropyl Alcohol and Ethanol. Care and Maintenance WOOD SURROUND AND BASE The M800 Organic Pedicure Spa is finished with a durable, water-resistant conversion varnish finish commonly used in high end commercial-grade furniture. The conversion varnish finish used on the M800 Organic Pedicure Spa will remain beautiful for many years. Conversion varnish has excellent resistance to nail polish, water and common cleaning chemicals. However, to maintain the beautiful appearance of your M800 Organic Pedicure Spa, a few care guidelines must be followed. Limit exposure to direct sunlight. Over exposure can cause a change in the appearance of your M800 Organic Pedicure Spa wood surround finish. Avoid cleaners with abrasives, bleach or ammonia. Do not apply acetone, solvents and caustic chemicals to the wood surround. When disinfecting the pedicure spa basin with a bleach solution, use care to avoid overspray on the wood surround. Cleaning Guidelines Generally a soft damp cloth followed by a dry cloth will be all you need to clean the finish. If a cleaner is required, use only a very mild soap (i.e. Murphy s Wood Soap) and water solution and wipe dry. Do Not s Do not use acetone, bleach, cleaning fluid, polishing oil, lemon oil, caustic detergents, soap pads, or steel wool on your wood surround. Polishing or oiling is not required and harsh abrasives will mar the wood finish. Do not use wax products, while they will not cause harm, they offer no benefit. Repairs Conversion varnish offers a very hard mar-resistant surface, but like any finish it may still be scratched or damaged if not cared for properly. For a repair kit or information on repair or restoration of the wood surface, please contact SpaFinity at (866) 726-0324. USING BATH ADDITIVES Enhance your clients pedicure bath experience with essential oils, aromatherapy products and other additives knowing all residue can be easily and completely removed. The M800 Organic Pedicure Spa can be used with most foot and skin care products, provided the Cleaning and Disinfection protocols are adhered to systematically. Products NOT recommended: Silicate based bath additives / scrubs may void warranty High foam agents (use only low foam solutions) Abrasive cleansers that might damage the basin or system components If you have any questions on products to be used with your M800 Organic Pedicure Spa, please contact SpaFinity Technical Support at (866) 726-0324. WARNING: Do not place nail care products on the M800 Organic Pedicure Spa. WARNING: Extended exposure to chemicals can damage the M800 Organic Pedicure Spa basin, footpad and/or fabric. Failure to comply with these instructions can cause damage to the M800 Organic Pedicure Spa and void the warranty. 23 24 www.spaequip.com P: 707-737-1100 F: 707-737-1150 Page 12 of 13

Troubleshooting NO POWER / NOT OPERATING 1) Power supply a. Ensure switch box power cord is properly plugged into an operational 115 VAC, GFCI power supply. b. Check GFCI reset and circuit fuses. 2) Dry Run Sensor Reset: a. Note: A dry run sensor automatically resets the M800 Organic Pedicure Spa if no water is present, or if unit had been inadvertently turned or left on. b. DO NOT OPERATE JET SYSTEM WITHOUT WATER FILLED AT LEAST 1 ABOVE THE JETS. c. Reset the motor by unplugging the system, waiting 5 seconds, then plugging system back in again. 3) Jet Assembly Alignment a. Check jet assembly is locked in the 9 o clock or 3 o clock run position in the jet motor case. b. Ensure magnetic rotor impeller is correctly installed in the jet motor case. c. Inspect separator plate to ensure proper assembly in the jet escutcheon. d. Inspect separator plate to ensure magnets (2) are present and properly installed. 4) Connections a. Remove 4 mounting screws to detach jet case from wall. (Remove only if rear access is not available.) b. Slide jet case out of wall and check the motor and ground lug connectors for proper connection to the wiring harness c. Make sure safety sensor connection is secure. d. Check switch box and ground lug connections to the wiring harness. e. Inspect air actuator and switch box air hose connectors for proper installation, and ensure air hose is free from blockage, kinks and debris. f. Inspect connectors and pins for damage / misalignment. EXCESSIVE NOISE 1) Remove jet assembly (escutcheon and separator plate) and inspect for dirt buildup, debris or damage. Clean or replace if necessary. 2) Remove magnetic rotor impeller and inspect for dirt buildup or debris. Clean or replace if necessary. 3) Switch rotor to other jet to test. (Note: Jet assembly must be reassembled and water refilled 1 above jets for proper test) 4) If noise persists, contact your distributor for motor replacement information. LEAKS 1) Mounting Screw O-Rings a. Ensure mounting screws, friction washers and o-rings are properly installed and tightened. b. Check wing anchors are firmly mounted to the back side surface. 2) Case / Flange O-Ring a. Adjust mounting screws by turning clockwise to ensure case / flange o-ring is compressed evenly. b. If leaking persists, remove 4 mounting screws to detach jet case from sink. c. Inspect case / flange o-ring for damage or misalignment. Replace if necessary. 3) Motor / Case O-Ring a. Remove 4 mounting screws and slide jet case out of wall. (Remove only if rear access is not available.) b. Disconnect wiring harness connector, ground lug and safety sensor. c. Rotate threaded collar shield to remove motor from jet case. Inspect motor / case o-ring for damage or misalignment. Product Specifications are Subject to Change Without Notice NSFProtocolP182 Pipeless Hydrotherapy Jets SpaFinity, Inc For all inquiries contact: Toll Free: 866-726-0324 Fax# 262-293-9590 E-mail: info@spafinity.com SpaFinity, Inc W175 N11120 Stonewood Dr, #104 Germantown, WI 53022 2008 SpaFinity, Inc Printed in U.S.A ML2001 Rev 1108 25 www.spaequip.com P: 707-737-1100 F: 707-737-1150 Page 13 of 13