pearl PRO Professional Hair Removal System Carefully read this manual before using this appliance. Ensure that you know how the appliance functions and how to operate it. Instructions for Use 1
Safety Precautions When using this product, safety precautions should always be followed, which include the following: 1. Use the Pearl Pro only as directed. 2. DO NOT use while bathing, and be sure skin is dry during use. Device must not get wet or be submerged in liquids. 3. Using the Pearl Pro Hair Remover should not cause skin irritation when used as directed. However, skin irritation may arise on sensitive skin. Apply Pearl Soothing Serum or a gentle moisturizer after each treatment to discourage irritation. 4. Use care when handling. Manufacturer s warranty will be voided if unit is damaged due to mishandling. 5. DO NOT attempt to touch the wire element in the tip attachment. The tip teeth protect your skin during normal use, but direct contact with the wire element will cause injury. 6. This product should not be operated by children. 7. DO NOT use on pets. 8. DO NOT use on genitals or breasts. 9. If you are pregnant, consult a doctor before use. 10. Using the Pearl Pro in a single area for too long increases the chance of skin irritation. If hair is not removed from an area after 3 or 4 passes, wait several minutes before trying again. You may need to shave after the first few sessions for complete hair removal, but after continued use you may find shaving to be unnecessary. 11. Should the Pearl Pro become damaged, DO NOT attempt to repair it. Product must be replaced by the manufacturer or its service agent in order to avoid a safety hazard. 12. This product is not for commercial use. 13. Do not use the Pearl Pro on damaged skin such as sunburns, cuts, warts, bruises or blisters, or on raised areas such as scars, moles, or loose skin. 14. Do not plug the 10V mini USB power cord into any device other than the Pearl Pro. The power cord voltage is higher than standard mini USB cords and will damage other devices. 2 Professional Hair Removal System
Getting to Know Your Pearl Pro The Pearl Pro is a safe, professional hair removal system that you can use in the comfort and convenience of your own home. The Pearl Pro system uses two methods for hair removal. The thermogenic method uses heat-transferring tips that crystallizes hair on contact. The electrolysis method uses a microcurrent-transmitting roller that sends electrical current into your hair follicles as it rolls across the skin. Using the Pearl Pro often takes time to master. For example, removing the hair from your legs may take 30 to 45 minutes to begin with, but most people are able to master the gliding technique within 2 to 3 sessions. Remember, practice makes perfect! At first, treatment may produce a burning smell and you may also see smoke. This means that the Pearl Pro is working, crystallizing the hair as it makes contact. The ideal length of hair to treat is 1-3 mm (1 mm is about the same as the thickness of a penny). You may need to trim or let hair grow before treatment. ALWAYS buff the treated area after use and moisturize! These steps are essential to successful results, and skipping any of these steps can result in incomplete hair removal. Individuals with sensitive skin may experience discomfort during treatment. If this occurs, you can reduce the temperature of the heat transfer tip and allow your skin to rest for a moment before passing over that area again. Remember, always use the soothing serum or a gentle moisturizer after every treatment. Before each use, make sure that the wire in the thermogenic tip is neither bent nor broken. If it is, dispose of it and install a new tip. If the tip problem indicator X appears on the LCD display, check to make sure the tip is properly installed. You may need to push down firmly to seat the tip properly onto the prongs. Check the wire housed within the tip. If it is broken or bent, discard and install a new one. Do not attempt to repair. The Pear Pro will automatically shut off after a few seconds when a problem with the tip is detected. Instructions for Use 3
Parts Diagram Cap Visibility Enhancement LED LCD Screen Prongs Electrolysis Roller Adjustment Select Power Charging Base Power Indication LED 4 Professional Hair Removal System
PRO Included in the Box pearl Pearl Pro Mini USB Charging Base 10V Mini USB Charging Cord Storage Pouch Cleaning Brush Buffer Handles + Buffing Pads LCD Screen Features 3 Small Tips & 3 Large Tips Tip Problem Indicator Microcurrent Level Tip Installed Indicator Battery Level Temperature Control Settings Low Med High Instructions for Use 5
Using the Pearl Pro Charging Plug the charging cord into the wall outlet and insert the mini USB end into the charging port of the Pearl Pro charging base. Place the Pearl Pro onto the charging base to charge. The charging cord can also be plugged directly into the Pearl Pro s power port. IMPORTANT: Charge for 4-6 hours before first use. Afterwards, charge as needed. Refer to the battery level indicator on the LCD display for charge level. Treatment 1. Remove the cap and install the heat transferring tip onto the prongs. Choose the right size tip for the area you plan to treat: large for areas like legs, arms and chest, small for more delicate areas like face, bikini line, and underarms. Once you have selected the appropriate size, align the prongs of the Pearl Pro with the holes in the tip and press gently down into place. 2. Press the power button to turn on. Press the select button. The temperature control display will blink, indicating it has been selected. Use the adjustment button (+ -) to set the temperature level. Press the select button again. The microcurrent control display will blink, indicating it has been selected. Use the adjustment button (+ -) to set the microcurrent level. At first, we recommend you keep both the temperature and the microcurrent on the lowest settings and raise them as you become used to using the Pearl Pro. 3. Hold the Pearl Pro at a 90 angle to the area being treated with the LCD screen and LED visibility enhancement light facing toward you. Make sure the metal roller is flat against the skin. Steadily glide the Pearl Pro upwards, against the direction of hair growth, then back down in the opposite direction, always with the LCD screen facing you. The visibility enhancement light will illuminate and glow continuously when 6 Professional Hair Removal System
an optimal speed and angle are used. If the light flickers, adjust your speed and/or angle accordingly. Always use the aid of a mirror when removing hair from your face, neck, or any area to which visibility would otherwise be limited or impossible. Press the power button to turn off the Pearl Pro. The Pearl Pro is also designed with a 15 minute auto-off timer for your safety. 4. Smooth the treated area with one of the Pearl Pro buffing pads provided with your unit. Firmly buff the skin in a circular or back and forth motion, taking care not to injure delicate areas. Buffing should not be painful. If discomfort occurs, decrease the amount of pressure applied. 5. Apply Pearl Soothing Serum or a gentle moisturizer to the area after each treatment for smooth, healthy looking skin. Care & Maintenance After using the hair remover, use the mini brush to remove any hair that may have collected inside the tip. Wait 5 minutes after turning off the unit before cleaning and always remove the tip from the device before beginning. Gently sweep hair away from the comb and wire element, taking care not to damage the tip while cleaning. Replacement Tips With long-term/repeated use, the wire element inside a thermogenic tip will wear out and break. This is normal and to be expected. When this happens, the tip problem indicator on the LCD display will blink and the unit will shut down. Do not attempt to repair or reuse a tip that is broken or damaged in any way. Remove it immediately and discard. Replace your Pearl Pro tip with a new one any time this occurs. For more information and to register your product visit viatekproducts.com. Instructions for Use 7
pearl PRO Professional Hair Removal System This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and the receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/tv technician for help. FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For customer service call 888.7.VIATEK (+1.423.402.9010 for outside the United States) or visit us online at viatekproducts.com. Pour le service a la clientele appelez le 888.7.VIATEK (+1.423.402.9010 a l extérieur des États-Unis) ou visitez viatekproducts.com. Para servicio al consumidor llame al 888.7.VIATEK (fuera de Estados Unidos marque +1.423.402.9010) o visite viatekproducts.com. DO NOT DISPOSE OF BATTERIES IN FIRE. ALWAYS DISPOSE OF BATTERIES PER LOCAL & FEDERAL GUIDELINES. Protect your product for 1 year beyond our standard warranty with the Viatek No Question Protection Extended Warranty Plan. With the Extended Warranty there are no return shipping charges, the product will be replaced or reimbursed with no deductible, and the product is protected 100% from any mechanical or electrical failures caused by power surges or manufacturer s defects. Order online at viatekproducts.com today. 2015 VIATEK CONSUMER PRODUCTS GROUP, INC. 6011 CENTURY OAKS DRIVE, CHATTANOOGA, TN 37416 All specifications are subject to change without notice. All rights reserved. PEARLHAIRREMOVAL.COM Read Instructions Before Operating MADE IN CHINA Model PH-PRO REV 062315 8 Professional Hair Removal System