CHIROPODY & PODIATRY INTERNATIONAL BROCHURE

Similar documents
Prestige 2100 Classic 9 Litres. Ultrasonic Cleaner CSU1 1 Gallon

Tips On Proper Instrument Cleaning, Handling and Maintenance!

Single Use Podiatry Instruments

The OZAKI VRec Sizer (13, 15, 17 mm) JD-001-P FOR The OZAKI VRec Sizer System INSTRUCTIONS FOR USE

Instrument Cleaning. Dental Clinics

BEAUTY TRIMMER. 1 YEAR WARRANTY MPT3800 Series USE & CARE MANUAL. To register your product go to

BODY & BIKINI KIT 2 YEAR WARRANTY WPG4020AU USE & CARE MANUAL. To register your product go to PLEASE READ PRIOR TO USE

Ultimate Body & Bikini Kit

WASHABLE NOSE, EAR & EYEBROW TRIMMER

By Paul Aylett at 3:58 pm, Jul 16, 2012

HAIRCUT KIT. 2 YEAR WARRANTY HC2000 Series USE & CARE MANUAL. To register your product go to PLEASE READ PRIOR TO USE

SECUROS Surgical. Instrument Care Guide. A guide to maintaining and protecting your surgical instruments

PRECISION PERSONAL GROOMER

Perfecting Facial Trimmer

HAIRCUT KIT. 2 YEAR WARRANTY HC1090 Series USE & CARE MANUAL. To register your product go to PLEASE READ PRIOR TO USE

Disposable Diathermy Electrodes

& other medical. Consumables, cleaners

INFECTION PREVENTION AND CONTROL PLAN

bmt_cat_maintenance_clean_steril_2014_03 Instructions and Methods of Use User Guide Instrument Cleaning, Sterilization & Maintenance

STANDARDIZED CLINICAL PROTOCOLS. Sterilization Protocols. Aravind Eye Care System 1, Anna Nagar, Madurai , Tamilnadu, India

PLAN REVIEW APPLICATION PACKET BODY ART ESTABLISHMENTS

EasyClean 500 series

Lenis Needle-free Safety Syringe Device User Manual

BODY ART FACILITY INFECTION PREVENTION AND CONTROL PLAN GUIDELINE

PROFESSIONAL BEARD TRIMMER

EasyClean 500 series

Body Art Facility Infection Prevention And Control Plan Guideline

BODY ART FACILITY INFECTION PREVENTION AND CONTROL PLAN

POWER TOOL HAIR CUT KIT

BLUSH STYLE COLLECTION

Implements and Bits For Foot Care Professionals

Always be on the safe side.

Containment/Transportation Standard precautions for handling contaminated/biohazardous materials should be observed.

Update Hygiene and maintenance according to EN ISO 17664:2017

under Council Medical Devices Directive (93/42/EEC) as updated directive 2007/47/EEC

Cleaning and Disinfection Protocol for Emergency Services Fire, Ambulance, Police, Search & Rescue

Cordless Ceramic Hair Cutting Set

Charging base. Trimming head (30mm) on charging stand. Main body unit. On/Off switch. Indicated light. Connecting jack Connecting jack

POWERGLIDE TITANIUM FEATURES

GENERAL ASSEMBLY OF NORTH CAROLINA SESSION 2001 H 1 HOUSE BILL 635. March 15, 2001

Manicure Instruments. Cuticle & Nail Scissors. Cuticle & Nail Scissors. Cuticle & Nail Scissors. Cuticle & Nail Scissors

Hand Hygiene & PPE Policy

ULTIMATE HAIRCUT KIT 2 YEAR WARRANTY HC5005AU USE & CARE MANUAL PLEASE READ PRIOR TO USE

SUTTER COUNTY DEVELOPMENT SERVICES DEPARTMENT

Maintenance Guidelines Scuba

We encourage our artists to autoclave reusable items between each client to preserve a safe and sanitary working environment.

Policy: C-08-PRO Reviewed: 7/08

Fosun Medical-----Surgical Sutures

10,000 prize draw. Register online for HC5800 HC5600 HC5400. EXTRA year guarantee FREE rewards gallery

BODY ART ESTABLISHMENT PLANNING APPLICATION

Caring for your Toenails

Wahl Hairdryer Instruction Booklet: PET PAW TRIMMER Pet Paw Trimmer Instruction Rev indd 1 12/03/ :04:21

JD400 Series. Cadaver Lift Tray Roller Pallet REFERENCE MANUAL. Rev

POWER PRO GROOMING KIT 2 YEAR WARRANTY USE & CARE MANUAL. To register your product go to remington-products.com.au remington.co.

Texas Department of Licensing & Regulation Health & Safety Sanitation Standards Topic Definitions

PrecisionCut Hair Clipper

TITANIUM ALL-IN-ONE RECHARGEABLE GROOMING SYSTEM

Maintenance Guidelines Compound

About Fosun Medical---Sutures sutures with needle (absorbable and FosMedic / MeiYi brand Surgical sutures are

DURABLADE PRO 5 YEAR WARRANTY MB061AU USE & CARE MANUAL. To register your product go to remington-products.com.au remington.co.nz

Hand Hygiene. Policy Title: Hand Hygiene Policy Number: 05. Effective Date: 6/10/2013 Review Date: 6/10/2016

Table 6: Detailed Infection Prevention and Control Procedures for Tattooing and Micropigmentation. Use During Tattooing

Maintenance Guidelines Ellipsis

TITANIUM TURBO PRO HAIRCUT KIT

INFECTION PREVENTION AND CONTROL PLAN (IPCP)

Manufactures and Exporters of Surgical Instruments, Dental Instruments & orthopedic Implants. Company Profile

MEDICAL WASTE MANAGEMENT

ISO Sharps injury protection Requirements and test methods Sharps containers

Hygienic requirements for tattoo and piercing studios

BSL-2 Emergency Plan

Sonic Facial Cleanser

Philips Sonicare 2 series Plaque control plus

POP ACRYLIC NAILS. user guide

LITHIUM ALL-IN-ONE BEARD TRIMMER

Beauty Tools Catalog SURGICAL CORPORATION

Preventing TASS Suggestions Courtesy, Outpatient Surgery Magazine May, 2010

Disposable Cartridge NAVEL Piercing System

Canary Yellow Notes. The Modern Classic

600/700. Charger type 3757 Handle type Braun GmbH Frankfurter Straße Kronberg Germany/Allemagne /XI-15 China/GB

BEARD BOSS PRO TRIMMER

BODY ART FACILITY PLAN REVIEW OVERVIEW

FREQUENTLY ASKED QUESTIONS ON RUBBER ELECTRICAL INSULATING GLOVES

THEFAMILYCLIP TOOL TIPS. for the essential clipping kit for professional family hair cuts VS704A

State of Kuwait Ministry of Health Infection Control Directorate SAFE INJECTION

Maintenance Guidelines Bluff

rooo.lb IOWA COUNTY ORDINANCE NO TATTOO ARTIST REGULATIONS THE IOWA COUNTY BOARD OF SUPERVISORS DO ORDAIN AS FOLLOWS:

Protective Clothing and Medical Devices

2018 A&L Product Reference Guide

QuickCut Clipper. 10,000 prize draw. Register online for HC4250. EXTRA year guarantee FREE rewards gallery

Beauty, Always in your palms Let s start over at first.

BODY ART ESTABLISHMENT INTRODUCTION GUIDE

Sonic Skincare Cleansing System

RESTORATIVE. Dermatology

PowerSeries Aqua. 10,000 prize draw. Register online for PR1350 PR1370. EXTRA year guarantee FREE rewards gallery

Infection Control 101

ReNu. Diamond Microdermabrasion Facial Tool User Manual

BIKINI TRIM WET/DRY BIKINI TRIMMING SYSTEM

Nose & Ear Trimmer. 10,000 prize draw. Register online for NE3155. EXTRA year guarantee FREE rewards gallery

A SAFE ANDCONNECTED APPROACH

5 in1. Hair & Beard Trimmer. with accessories. Instruction Manual V

Transcription:

CHIROPODY & PODIATRY INTERNATIONAL BROCHURE 2016

TIMESCO HEALTHCARE PODIATRY INSTRUMENTS Timesco Healthcare have over 50 years experience as manufacturers of Medical instrumentation. As a Worldwide provider of Podiatry instruments, we are now an established and highly recognised supplier throughout the world. We conform to ISO 13485 and all our instruments go through a highly stringent quality control process by our dedicated Quality Control Team at our Headquarters in Basildon, Essex, England. Our Export Department is also based at our Headquarters in the UK. This is managed by Mr Keith McVeigh, our International Sales Manager, Mr Simon Cox who is responsible for our European Market and supported by our internal Business Support Team, led by Mr Mark Lapping and Mrs Heather Nash. Please see below the contact details for the team, who will be delighted to assist you as necessary. CROWN DENTAL + MEDICAL Crown serves the dental, medical and veterinary professions throughout Australia, New Zealand and the Pacific Islands, dealing primarily in consumable products and small equipment items. Representing a line-up of trusted international manufacturers, Crown offers some of the latest products from around the world. We also supply other healthcare professionals, such as beauty therapists, chiropractors, massage therapists, tattooists, podiatrists, etc. With over 35 years of business experience in the health industry ensures we will continue to provide quality products from some of the world s leading manufacturers. Our focus, as always, will be to service the healthcare industry with distinction. Crown Dental + Medical is proudly a 100% New Zealand owned company. Our Customer Service Team and experienced Telephone Account Managers provide you with a friendly and knowledgeable service making the Crown customer experience a pleasure. GUARANTEE Our Podiatry instruments are covered by an extensive 5 year guarantee or 4,000 autoclave cycles. The respective guarantee will be the number of years or the number of autoclave cycles, whichever is sooner and is from the date of purchase. Autoclave cycles are approved to 134ºC for 3 minutes holding time or 134ºC for 18 minutes holding time. If any of Timesco s reusable products crack, bend, deform, corrode or fail whilst being used for the intended purpose within the guarantee period, we will repair it or replace it free of charge. Reusable Instruments: Guarantee Number of autoclave cycles Reusable instruments (excluding the sections of the products listed below) 5 years 4,000 The cutting, shearing, grinding and rasping edges (excluding Tungsten Carbide) 1 year 800 The cutting, shearing, grinding and rasping edges (Tungsten Carbide) 2 years 1,600 CONTENTS Foot Dressers 3 Cuticle Cutter 3 Nail Cutters 3-6 Cantilever Nail Cutters 6 Ingrown Nail Cutter 6 Nail Excavators 7 Nail Files 7-9 Nail Probes 9 Nail Spatulas 10 Nail Elevators 10 Nail Curette 10-11 Gauze Applicators 11 Felt Scissors 11 Cleaning Instructions 12-13 Crown Dental + Medical 0508 333 222 www.crowndental.co.nz

FOOT DRESSERS, CUTICLE CUTTERS & NAIL CUTTERS 10.795.20 TIMESCO FOOT DRESSER 10.790.20 STEEL FOOT DRESSER 10.795.10 EMERY DRESSER 9 (23cm) Plastic Handle Emery Coating Single Patient Use 8 (20cm) Steel 7 (18cm) Cardboard Single Patient Use Pack of 100 *Colour may vary 10.155.40 CUTICLE CUTTER/TISSUE NIPPER 4 (10cm) 10.180.50 NAIL CUTTER, STRAIGHT 4 (10cm) Straight Grooved Handles T +44 (0) Crown 1268 Dental 297 710 + Medical F +44 0508 (0) 1268 333 297 222 801 www.crowndental.co.nz E sales@timesco.com *All prices exclude GST. 3

NAIL CUTTERS 10.183.50 NAIL CUTTER, STRAIGHT Nail Cutter 4.5 (11.5cm) Straight Narrow 10.185.50 NAIL CUTTER, STRAIGHT 5 (13cm) Straight Grooved Handles 10.187.50 NAIL CUTTER, CURVED 10.188.50 NAIL CUTTER, STRAIGHT 5 (13cm) Curved Grooved Handles 5 (13cm) Straight Fine Jaw Grooved Handles Curved Blade Straight Blade 4 T +44 (0) Crown 1268 297 Dental 710 + Medical F +44 (0) 0508 1268 333297 222801 www.crowndental.co.nz E sales@timesco.com*all prices exclude GST.

NAIL CUTTERS 10.225.50 NAIL CUTTER, STRAIGHT 6 (15.5cm) Grooved Handles 10.227.50 NAIL CUTTER, CURVED 6 (15.5cm) Grooved Handles Straight Blade Curved Blade 10.255.50 NAIL CUTTER, STRAIGHT Lock & Smooth Handles 10.275.50 NAIL CUTTER, CURVED Lock & Smooth Handles Straight Blade Curved Blade T +44 (0) Crown 1268 Dental 297 710 + Medical F +44 0508 (0) 1268 333 222 297 801 www.crowndental.co.nz E sales@timesco.com *All prices exclude GST. 5

NAIL CUTTERS 10.275.65 NAIL CUTTER, STRAIGHT Lock & Diamond Knurled Handles 10.275.75 NAIL CUTTER, CURVED Lock & Diamond Knurled Handles Straight Blade Curved Blade 10.325.51 CANTILEVER NAIL CUTTER, CURVED 10.356.50S THWAITE INGROWN NAIL CUTTER 6 (15.5cm) Lock & Knurled Handles 5.75 (14.5cm) Anvil Type Chisel End Pointed Cutting Jaw Grooved Handles Chisel End 6 T +44 (0) Crown 1268 297 Dental 710 + Medical F +44 (0) 0508 1268 333297 222801 www.crowndental.co.nz E sales@timesco.com*all prices exclude GST.

NAIL EXCAVATORS & FILES 10.500.20 NAIL EXCAVATOR 6.25 (16cm) Angled Round Head 10.520.20 NAIL EXCAVATOR 6.5 (16.5cm) Swan Neck Flat 10.540.20 NAIL EXCAVATOR & FILE 7 (18cm) File Angled Swan Neck Excavator 10.560.20 BAKA NAIL FILE 10.570.40 NAIL FILE 10.570.60 NAIL FILE 4.75 (12cm) Extra Small Head Extra Fine Cut Medium Head Fine Cut Coarse Extra Fine Cut Fine Cut Course Cut T +44 (0) Crown 1268 Dental 297 710 + Medical F +44 0508 (0) 1268 333 222 297 801 www.crowndental.co.nz E sales@timesco.com *All prices exclude GST. 7

NAIL FILES 10.590.40 NAIL FILE 10.590.60 NAIL FILE 10.590.80 NAIL FILE 6 (15.5cm) Medium Heads Fine/Coarse Cut 6 (15.5cm) Extra Fine Medium Heads Swan Neck Probe Fine Cut Swan Neck Probe Coarse Cut Medium Head File 10.592.20 NAIL FILE Narrow Heads Straight/Curved Medium Cut * Double Ended 10.595.20 NAIL FILE 6.25 (16cm) Medium Heads Straight/Angled Medium Cut 10.603.20 NAIL FILE Small Head Medium Cut Curved Head Straight Head Straight Head Angled Head Medium Cut 8 T +44 (0) Crown 1268 Dental 297 710 + Medical F +44 0508 (0) 1268 333 222 297 801 www.crowndental.co.nz E sales@timesco.com *All prices exclude GST.

NAIL FILES & PROBES 10.605.20 NAIL FILE 10.610.20 NAIL FILE 10.620.20 NAIL FILE 6 (15.5cm) Medium Head Medium Cut 4.5 (11.5cm) Medium Head Medium Cut Extra Narrow Head Fine Cut Medium Cut Medium Cut Fine Cut 10.710.40 NAIL PROBE 10.715.20 NAIL PROBE 10.716.20 NAIL PROBE Angled Flat Head Swan Neck Flat Swan Neck Flat Fine Cut Angled Swan Neck Swan Neck T +44 (0) Crown 1268 Dental 297 710 + Medical F +44 0508 (0) 1268 333 222 297 801 www.crowndental.co.nz E sales@timesco.com *All prices exclude GST. 9

NAIL SPATULAS, PROBE WITH SPATULA & ELEVATORS 10.718.20 NAIL PROBE 10.665.20 NAIL SPATULA 10.740.20 NAIL PROBE & SPATULA Swan Neck Cup 4.5 (11.5cm) 6.25 (16cm) Swan Neck 10.440.20 FICKLING NAIL ELEVATOR 10.445.20 FICKLING NAIL ELEVATOR 5 (13cm) 10.470.20 NAIL ELEVATOR 6.25 (16cm) Curved Round/Point 10 T +44 (0) Crown 1268 Dental 297 710 + Medical F +44 (0) 0508 1268 333297 222801 www.crowndental.co.nz E sales@timesco.com*all prices exclude GST.

NAIL CURETTES, GAUZE APPLICATORS & FELT SCISSORS 10.398.30 NAIL CURETTE 10.396.20 NAIL CURETTE 10.396.30 NAIL CURETTE 1mm Scoop with Hole 2mm Scoop with Hole 5 (13cm) 1.5mm, No Hole 5 (13cm) 2mm, No Hole 2mm scoop with hole 1mm scoop with hole 1.5mm scoop - no hole 2mm scoop - no hole 10.960.40 GAUZE APPLICATOR Small Size 00 10.960.70 GAUZE APPLICATOR Large Size 0 10.090.40 FELT SCISSORS 6 (15.5cm) Straight Heavy Blunt/Sharp T +44 (0) Crown 1268 Dental 297 710 + Medical F +44 0508 (0) 1268 333 222 297 801 www.crowndental.co.nz E sales@timesco.com *All prices exclude GST. 11

INSTRUCTIONS FOR RE-PROCESSING TIMESCO REUSABLE INSTRUMENTS The following instructions are for all Timesco reusable instruments by Timesco Healthcare, unless stated otherwise with the packaging of the product. All reusable devices are supplied non sterile and should be cleaned and sterilised before first use and after each subsequent use. These instructions are intended for use only by persons with the required specialist knowledge and training. WARNINGS Follow instructions and warnings as issued by manufacturers of any decontaminants, disinfectants and cleaning agents used. Wherever possible avoid use of mineral acids and harsh, abrasive agents. Do not use chemical sterilants with caustic ingredients such as: surgical scrub solutions, povidone-iodine solutions, bleach, peroxide solutions, Virox 3, Sporox and Cidex PA. Do not use garment or surface disinfectants. Do not autoclave with sub standard stainless steel surgical instruments as this may cause a reaction and lead to rust or discolourisation. No part of the process shall exceed 140º C. Ultrasonic cleaning is not permitted, as this will cause damage to the glass fibre optic bundle. Do not flash autoclave, this will invalidate our guarantee. When reprocessing medical devices, handle with care, wearing protective clothing and face visors or goggles where appropriate. Batteries must be removed from any battery operated devices before reprocessing. LIMITATIONS ON REPROCESSING These reprocessing instructions will have a minimal effect on all devices, but repeated autoclaving, especially for extended periods can affect certain devices. INSTRUCTIONS FROM POINT OF USE If possible, soiled devices should be placed in a holding solution (combined disinfectant/enzyme solution) immediately after use and prior to cleaning. PREPARATION FOR DECONTAMINATION Reprocess all devices as soon as it is reasonably practical to do so. Where necessary disassemble devices that require disassembly for adequate cleaning and reprocessing. CLEANING: MANUAL Some devices cannot be effectively cleaned by a washer-disinfector, those items should be manually cleaned as follows and then cleaned in a washer-disinfector as below: Using a sink dedicated for instrument cleaning (not used for hand washing), rinse excess soil from the device (water temp <35º C). Keeping the device submerged, with a brush, apply CE marked cleaning solution to all surfaces. Pay particular attention to underside and any jointed part of the device. Always brushing away from the body. Do not use a wire brush. Rinse the device thoroughly with clean water, so that the water reaches all parts of the device, then carefully hand dry or use a drying cabinet. CLEANING: AUTOMATED Use only either CE marked or validated washer-disinfector machines and cleaning agents, following the manufacturers instructions for use, warnings and recommended cycles. Load devices carefully, ensure any delicate parts of the device are not liable to damage during the loading procedure. Timesco devices have been validated to the following automatic washer-disinfector cycle: Pre wash 14.4 ºC for 4 minutes, Wash at 65.9 ºC for 9 minutes, Rinse at 58.8 ºC for 16 seconds, Thermal at 92 ºC for 6 minutes 14 seconds, Drying at 98.8 ºC for 25 minutes. Validated detergents, Instro-Klenz, Enzycare, Olympic Spraydry 1000 and Sprayclean 2000. CLEANING: INSPECTION After cleaning, check all surfaces for complete removal of soil. If any soil is still visible, return the device for repeat decontamination. REASSEMBLY If any devices have been disassembled, reassemble in accordance with any product specific instructions for use and test. INSPECTION AND FUNCTION TESTING Visually inspect and check all devices for damage and wear. Remove for repair or replacement any damaged product. PACKAGING All devices should be packed following local protocol in accordance with BS standards Continued on the next page > 12 T +44 (0) Crown 1268 Dental 297 710 + Medical F +44 0508 (0) 1268 333 222 297 801 www.crowndental.co.nz E sales@timesco.com

INSTRUCTIONS FOR RE-PROCESSING TIMESCO REUSABLE INSTRUMENTS STERILISATION Either CE marked or validated vacuum autoclave operating at 134-137 ºC 2.25 bar for a minimum holding time of 3 minutes - always following the instructions of the machine manufacturer. When sterilising multiple instruments in one autoclave cycle, ensure that the steriliser manufacturer s stated maximum load is not exceeded. Ensure all devices are dry before sterilisation. If the devices cannot be dried prior to sterilisation, then use distilled/de-ionised water in the final-rinse stage of cleaning. Timesco devices have been validated to the following steriliser cycle: Sterilising temperature 134 ºC, Sterilising time 3 minutes, 10 seconds, Normal drying time 5 minutes, Extended Drying time 15 minutes. STORAGE Ensure all devices are dry before storage, and stored in dry, clean conditions at an ambient room temperature. ADDITIONAL INFORMATION Other forms of cleaning (alkaline and neutral) and sterilisation (Cidex OPA, Ethylene oxide up to 65 ºC for anaesthetic devices) are permitted. However, always follow the instructions for use as issued by Timesco and always consult with us if in any doubt over the suitability of any processused. Follow cleaning and sterilising guidelines as per HTM 2030 and HTM 2010. MANUFACTURER Timesco Healthcare Ltd, Timesco House, 3 Carnival Park, Carnival Close, Basildon, Essex, SS14 3WN, England. E-mail info@timesco.com, Website www.timesco.com NOTE: IT IS THE RESPONSIBILITY OF THE REPROCESSOR TO ENSURE THAT THE REPROCESSING AS ACTUALLY PERFORMED USING EQUIPMENT, MATERIALS AND PERSONNEL IN THE REPROCESSING FACILITY ACHIEVE THE DESIRED RESULT. THIS REQUIRES VALIDATION AND ROUTINE MONITORING OF THE PROCESS. LIKEWISE ANY DEVIATION BY THE REPROCESSOR FROM THE INSTRUCTIONS PROVIDED MUST BE PROPERLY EVALUATED FOR EFFECTIVENESS AND POTENTIAL ADVERSE CONSEQUENCES. Virox 3, Sporox, Cidex PA, Instro-Klenz, Enzycare, Olympic Spraydry 1000 and Sprayclean 2000 are trademarks of their respective companies. PRODUCT GUARANTEE Timesco offer extensive guarantees across our range of reusable surgical products, users should refer to the specific guarantees provided with each product. These guarantees do not cover consumables or disposable items, fair wear and tear or any damage caused by misuse. Any alteration or marking of the product in any way will also invalidate these guarantees and the CE mark. RETURNING INSTRUMENTS TO TIMESCO Products returned to Timesco Healthcare Ltd must be accompanied by a decontamination certificate, which states that each instrument has been thoroughly cleaned and disinfected. Timesco reserve the right to immediately dispose of any products that are returned without evidence of adequate cleaning and disinfection. Please contact our customer services team for authorisation before returning any product as we may be able to resolve your query or arrange a replacement without the product having to be returned. T +44 (0) Crown 1268 Dental 297 710 + Medical F +44 0508 (0) 1268 333297 222801 www.crowndental.co.nz E sales@timesco.com 13

NOTES 14 Crown Dental + Medical 0508 333 222 www.crowndental.co.nz

NOTES Crown Dental + Medical 0508 333 222 www.crowndental.co.nz 15

Timesco are the UK s premier manufacturer of medical devices for Anaesthesia, Surgery, Podiatry and Primary Care since 1964. Available exclusively through: Product Pricing The prices provided are subject to change without notification and exclude GST. For the latest pricing contact customer services: 0508 333 222 Phone: 0508 333 222 Fax: 03 338 3899 Online: www.crowndental.co.nz Email: general@crowndental.co.nz Mail: PO Box 640, Christchurch 8140, New Zealand