CAUTION: 1.38 PT (22 FL OZ) 650 ml KEEP OUT OF REACH OF CHILDREN. Kills C. difficile spores

Similar documents
Technical Information. Clorox Healthcare Bleach Germicidal Cleaner OVERVIEW. Clorox Healthcare Bleach Germicidal

_Clorox Scentiva Disinfecting Multi-Surface Cleaner Fresh Brazilian Blossoms_ _205_5813_.pdf KILLS 99.9% OF VIRUSES & BACTERIA*

The future of disinfection is here

Clorox Total 360 System

Cleaning and Disinfection Protocol for Emergency Services Fire, Ambulance, Police, Search & Rescue

Infection Control Solutions Product Solutions. for Surfaces & Skin

1 Gallon. 1 Gallon. 2.5 Gallon. Clorox Pine-Sol. 144 oz (4.3L) BIREX se (Biotrol) Refill Pack, 24 x 1/8 oz Packets

Your Solution for Infection Control. The Standard Protocol in Infection Control

Veterinary Care. Method Bulletin Microcide TB 256 Century Q 64 Millennium Q

What is infection control?

Hand Care Product Systems. Your hands have been in good hands for over 60 years...

Sterilization A Training Module

Bloodborne Pathogens Exposure Control Plan. December 2003

SAFETY PRODUCT PORTFOLIO

INFECTION PREVENTION AND CONTROL PLAN

Chlorhexidine Gluconate Antimicrobial Skin Cleansers TECHNICAL DATA

Annual Associate Safety Module. Blood & Body Fluids: How To Prevent Exposure Your Exposure Control Plan

CLINITEX A RANGE OF WIPES, CLEANSING & JANITORIAL PRODUCTS FOR HEALTHCARE PROFESSIONALS

INSECT REPELLENT. Repels Mosquitoes That May Transmit The ZIKA, WEST NILE, DENGUE & CHIKUNGUNYA VIRUSES Active Ingredient:

Texas Department of Licensing & Regulation Health & Safety Sanitation Standards Topic Definitions

Bloodborne Pathogens

DECON-HAND. Instant Hand Sanitizer. HAND_VL Revised 19 November, Technical Data File

RULES OF TENNESSEE BOARD OF COSMETOLOGY AND BARBER EXAMINERS CHAPTER SANITARY REQUIREMENTS TABLE OF CONTENTS

ALVERNIA UNIVERSITY MRSA CLEANING AND DISINFECTION PROCEDURES REVISION: EFFECTIVE

Infection Control 101

FREQUENTLY ASKED QUESTIONS. 1. What is the difference between a Disinfectant and a Sanitizer?

RTU Handi Sprays. Providing Quality Maintenance and Chemical Specialty Solutions with Unparalleled Customer Service

State of Kuwait Ministry of Health Infection Control Directorate SAFE INJECTION

under Council Medical Devices Directive (93/42/EEC) as updated directive 2007/47/EEC

Hand Hygiene & PPE Policy

INFECTION PREVENTION STANDARDS FOR THE PRACTICE OF ELECTROLYSIS (Rev. MAY 2016) PREFACE

Policy: C-08-PRO Reviewed: 7/08

Hand Hygiene. Policy Title: Hand Hygiene Policy Number: 05. Effective Date: 6/10/2013 Review Date: 6/10/2016

TECHNICAL BULLETIN PURELL Waterless Surgical Scrub Technical Data

CLEANING, SANITIZING, AND DISINFECTING

Odor is the Leading Cause of Poor Restroom Experiences 72% of U.S. adults consider bad smell the No. 1 cause of awful restroom experience.

OxyBAC. Antimicrobial rich-cream foam hand wash. Kills % of many common germs

BSL-2 Emergency Plan

Material Safety Data Sheets (MSDS)

SUBCHAPTER 14H - SANITATION SECTION SANITATION

EcoHydra Antimicrobial Hand Lotion. Product Overview. Physical Properties. Product Description. Regulatory Compliance. Key Features and Benefits

Welcome. to Infection Control. Cutan. Trada.Co

PUBLIC HEALTH DEPARTMENT

List any references used for the procedure design (research publications, etc.):

Provide a brief description of the procedure and infectious organisms used:

BSL2 Exposure Control Plan: Human or Non Human Primate Materials

Handling and Disposing of Needles

Instructor Guide. Georgia Department of Technical and Adult Education. Decontamination and Infection Control

Health Canada registered to kill C.difficile Spores in 5 minutes*

General Lab Safety Rules and Practices SOP-GLSRP-01

Nova Scotia Safe Body Art Standards

RULES OF TENNESSEE STATE BOARD OF COSMETOLOGY CHAPTER SANITARY RULES TABLE OF CONTENTS

BTB000 Manufacturers Product Code: TAB/R/DR

Hand Hygiene ORGANIZATIONAL: Affects two or more departments.

METHODS OF IMPLEMENTATION AND CONTROL

WHISTON WORRYGOOSE JUNIOR AND INFANT SCHOOL

Hygienic requirements for tattoo and piercing studios

50 ML FOAM HAND SANITISER

(c) BODY ART ESTABLISHMENT means any location, whether temporary or permanent, where the practices of body art are performed.

ABOUT US. Behban pharmed lotus co. is a leading supplier. We have valid international certificates such

Deadly Bloodborne Diseases

A ppendix 15 WUStL Bloodborne Pathogens Exposure Control Plan Research Laboratory-Specific Work Practices

rooo.lb IOWA COUNTY ORDINANCE NO TATTOO ARTIST REGULATIONS THE IOWA COUNTY BOARD OF SUPERVISORS DO ORDAIN AS FOLLOWS:

MAX REPELS MOSQUITOES, %DEET PROTECTION. INSECT REPELLENT Sportsmen. Net Wt 4 oz (113 g) KEEP OUT OF REACH OF CHILDREN LOTION FORMULA

Clinical Environments Cleaning, Care, and Maintenance

INFECTION PREVENTION AND CONTROL PLAN (IPCP)

Michigan State University Athletic Training Students BLOOD BORNE PATHOGENS AND UNIVERSAL PRECAUTIONS

BODY ART GUIDELINES. Purpose. Definitions. Body Art Technician Requirements

TATTOOING, BODY PIERCING, PERMANENT COSMETICS & BRANDING APPLICATION FOR REGISTRATION

NATIONAL WAX TECHNICIAN PRACTICAL EXAMINATION CANDIDATE INFORMATION BULLETIN

Bloodborne Pathogens Exposure Control Plan

Disinfectants in Personal Services Settings

TEN EASY STEPS FOR CLEANING A SPILL IN THE BIOSAFETY CABINET

Bloodborne Pathogens Safety in Your Workplace

University Of Florida. Bloodborne Pathogen Program. Standard Operating Procedures

OSHA: Occupational Safety and Health Administration PPE Personal protective equipment

Hand Wash. How to. IQ Hand Blue Soap. antibacterial and perfumed. Product Properties. Special Information. Environmental Information

BlephEx...A Revolutionary New Treatment for Blepharitis. Owner s Manual

NATIONAL ELECTROLOGY PRACTICAL EXAMINATION CANDIDATE INFORMATION BULLETIN

Bloodborne Pathogens: Exposure In The Workplace Employee Handbook

STANDARDIZED CLINICAL PROTOCOLS. Sterilization Protocols. Aravind Eye Care System 1, Anna Nagar, Madurai , Tamilnadu, India

Sanitation and Infection Control How professionals should safe-guard their salon and spa. by Dasha Saian, L.E.

INFECTION CONTROL SOLUTIONS

MEDICAL WASTE MANAGEMENT

FLORIDA GULF COAST UNIVERSITY DEPARTMENT OF REHABILITATION SCIENCES BIOSAFETY AND INFECTIOUS AGENTS CONTROL PLAN

Table 6: Detailed Infection Prevention and Control Procedures for Tattooing and Micropigmentation. Use During Tattooing

City and County of Denver Rules and Regulations for Body Artist, Body Art Establishments, and Mobile Body Art Vehicles Chapter 24 DRMC

STANDARD: Laboratory Safety Effective: March 20, 2018

UNIVERSITY OF NORTH FLORIDA BIOMEDICAL WASTE MANAGEMENT PLAN DEVELOPED BY: ENVIRONMENTAL HEALTH, SAFETY, INSURANCE & RISK MANAGEMENT

T O R K HAND CLEANING FAQ S GUIDE

Clean-it Brick and Masonry

Disposal of Biological Waste

MM SMP LEMON500 MM SMP MM SMP 72510

Microdot Bleach Wipe

Complete, Confident, Compliant. Sanitation Solutions For Your Food Processing Facility

Current Status: Active PolicyStat ID: Original Policy: 10/1986 Last Reviewed: 01/2016 Last Revised: 01/2016 Next Review: 01/2019

Artesian Pedicure System

Emergency Procedures Specific Biological Spill Clean-Up Guidelines

A complete cycle of infection prevention products.

The following standard practices, safety equipment, and facility requirements apply to BSL-1:

Transcription:

EPA Reg. No. 56392-7 Clorox Healthcare Bleach Germicidal Cleaner [22 oz] Page 1 of 3 99.99% Bacteria, Viruses, MANTÉNGASE FUERA DEL ALCANCE DE LOS NIÑOS PRECAUCIÓN: LEA LAS INSTRUCCIONES Y PRECAUCIONES COMPLETAS EN LOS PANELES DE ATRÁS. Si usted no entiende la etiqueta, busque a alguien para que se la explique a usted en detalle. Clostridium difficile Bleach Germicidal Cleaner Limpiador Germicida con Blanqueador 1.38 PT (22 FL OZ) 650 ml OTHER INGREDIENTS:...99.35% TOTAL:...100.00% INGREDIENTE ACTIVO: Hipoclorito de Sodio...0,65% OTROS INGREDIENTES:...99,35% TOTAL:...100,00% No contiene fósforo. NI-25247 Peel for Additional Directions Multipurpose, broad spectrum cleaner disinfectant for use in healthcare and other areas where control of cross contamination is required, especially during outbreaks of Clostridium difficile and other Healthcare Associated Infections (HAIs) listed on this label. Meets OSHA Bloodborne Pathogen Standards. May be used for instrument pre-cleaning and disinfection of non-critical instruments. DIRECTIONS FOR USE: It is a violation of Federal Law to use this product in a manner inconsistent with its labeling. Always refer to manufacturer s care instructions before using on equipment or devices. TO REFILL: Remove: Remove trigger sprayer from empty bottle. Pour: Unscrew cap on refill and pour contents directly into empty bottle. Use: Replace trigger sprayer and use as you normally would. To Clean, Disinfect and Deodorize in One Step: Spray 6" 8" from surface until surface is completely wet. To disinfect, let stand for one minute. Wipe with a clean, damp cloth or paper towel or allow to air dry. For food contact surfaces, rinse with potable water. For all other surfaces no rinsing is required. Gross soil must be removed prior to disinfecting. To Clean: Follow directions above or apply with a clean cloth, mop, or sponge saturated with Clorox Healthcare Bleach Germicidal Cleaner until surface is completely wet. (When applying with a saturated cloth or sponge, gloves should be worn.) No standing time is required. If streaking is observed, wipe with a clean, damp cloth or paper towel. PRECAUTIONARY STATEMENTS: HAZARDS TO HUMANS AND DOMESTIC ANIMALS. Causes moderate eye irritation. Avoid contact with eyes or clothing. Wash thoroughly with soap and water after handling. FIRST AID: If in Eyes: Hold eye open and rinse slowly and gently with water for 15 20 minutes. If present, remove contact lenses after the first 5 minutes, then continue rinsing eye. Call a poison control center or doctor for further treatment advice. Have the product container or label with you when calling a poison control center or doctor or going for treatment. PHYSICAL OR CHEMICAL HAZARDS: Do not use this product with ammonia or acids such as vinegar, rust removers, or toilet bowl cleaners. This product not intended for use on fabrics. For MSDS information, please go to www.cloroxhealthcare.com. A list of this product s ingredients is available at www.ingredientsinside.com. Una lista de los ingredientes de este producto se encuentra disponible en www.ingredientsinside.com. Mfd. for Clorox Professional Products Company, 1221 Broadway, Oakland, CA 94612. Clorox Healthcare is a registered trademark of The Clorox Company. 2014 Made in the U.S.A. EPA Reg. No. 56392-7. EPA Est. No. 8251-OH-1 (Q6); 5813-GA-1 (A4); GA-2 (VG). Beginning of batch code indicates Est. No. 0 00000 00000 0 R0964030 NI-25248 56392-7_PPD_HC_BLGRM_Clnr_22oz_R0964030.indd 1 8/6/14 11:20 AM

EPA Reg. No. 56392-7 Clorox Healthcare Bleach Germicidal Cleaner [22 oz] Page 2 of 3 Para Limpiar, Desinfectar y Desodorizar en Un Sólo Paso: Rocíe a una distancia de 6 8 pulgadas de la superficie hasta que esté completamente mojada. Para desinfectar, deje reposar un minuto. Limpie con un paño o con una toalla de papel limpia y húmeda o deje secar al aire. Para superficies que entren en contacto con los alimentos, enjuague con agua potable. Para las demás superficies no se requiere enjuague. El exceso de mugre se debe quitar antes de desinfectar. Para Limpiar: Siga las instrucciones de arriba o aplique con un paño, esponja o trapeador limpio y saturado con el Limpiador Germicida con Blanqueador Clorox Healthcare hasta que la superficie esté completamente mojada. (Se deben usar guantes cuando se aplique con un paño o esponja saturada.) No requiere tiempo de reposo. Si se observan rayas, limpie con un paño o con una toalla de papel limpia y húmeda. DECLARACIONES PREVENTIVAS: RIESGOS PARA LOS SERES HUMANOS Y ANIMALES DOMÉSTICOS. PRECAUCIÓN: Causa irritación moderada a los ojos. Evite el contacto con los ojos o la ropa. Lávese bien con agua y jabón después de usar. PRIMEROS AUXILIOS: Contacto con los Ojos: Mantenga los ojos abiertos y enjuague con agua lentamente, con cuidado, durante 15 20 minutos. Si hay lentes de contacto, retírelos después de los primeros 5 minutos, luego continúe enjuagando los ojos. Llame a un médico o a un centro de control de envenenamiento para obtener más asesoría sobre el tratamiento. Cuando llame a un centro de control de envenenamiento o a un médico, o intente obtener tratamiento, tenga a la mano el envase o la etiqueta del producto. RIESGOS FÍSICOS O QUÍMICOS: No use este producto con amoníaco ni ácidos como vinagre, removedores de óxido o productos para limpiar el inodoro. Este producto no está hecho para usarse en telas. DIRECTIONS FOR USE continued: Special Instructions for Cleaning Prior to Disinfection against Clostridium difficile. Personal Protection: Wear appropriate barrier protection such as gloves, gowns, masks, or eye covering. Cleaning Procedure: Fecal matter/waste must be thoroughly cleaned from surfaces/objects before disinfection by application with a clean cloth, mop, and/or sponge saturated with this product. Cleaning is to include vigorous wiping and/or scrubbing, until all visible soil is removed. Special attention is needed for high-touch surfaces. Surfaces in patient rooms are to be cleaned in an appropriate manner, such as from right to left or left to right, on horizontal surfaces, and top to bottom, on vertical surfaces, to minimize spreading of the. Restrooms are to be cleaned last. Do not reuse soiled cloths. Infectious Materials Disposal: Materials used in the cleaning process that may contain feces/wastes are to be disposed of immediately in accordance with local regulations for infectious materials disposal. Disinfection Procedure: Spray 6" 8" from surface until surface is completely wet. Let stand for 5 minutes. Wipe with a clean, damp cloth or paper towel or allow to air dry. To Preclean Instruments Prior to Terminal Sterilization/High Level Disinfection: As a pre-cleaning spray Place instruments into a suitable container. Spray Clorox Healthcare Bleach Germicidal Cleaner onto instruments to thoroughly wet all surfaces. Let stand for up to 10 minutes. Rinse instruments. As a pre-cleaning immersion solution Fill appropriate size container with a sufficient amount of Clorox Healthcare Bleach Germicidal Cleaner to completely submerge instruments. Place instruments into the container of Clorox Healthcare Bleach Germicidal Cleaner, cover, and allow to soak for up to 10 minutes. Remove and rinse, and follow with an appropriate cleaning and disinfecting process. Change solution daily. As a manual instrument cleaner Thoroughly pre-rinse dirty instruments under running water to remove visible, gross debris. Immerse pre-rinsed instruments into an appropriate size container filled with Clorox Healthcare Bleach Germicidal Cleaner. Scrub instruments using a stiff bristle brush until visibly clean. Submerge instruments while scrubbing. Rinse instruments thoroughly. Change solution daily. Follow with an appropriate disinfection process. Cleaning of critical and semi-critical devices must be followed by an appropriate terminal sterilization/high-level disinfection process. To Disinfect Non-Critical, Pre-cleaned Instruments: Instruments must be thoroughly pre-cleaned to remove excess organic debris, rinsed, and rough dried. (Clean and rinse lumens of hollow instruments before filling with Clorox Healthcare Bleach Germicidal Cleaner or before immersion.) Immersion method Using a soaking tray, immerse instruments into Clorox Healthcare Bleach Germicidal Cleaner and let stand for one minute. Remove and wipe with a clean, damp cloth or paper towel and allow to air dry. Change solution for each use. Spray method Spray all surfaces of instruments with Clorox Healthcare Bleach Germicidal Cleaner until thoroughly wet. Let stand for one minute. To kill Clostridium difficile (), let stand for five minutes. Wipe with a clean, damp cloth or paper towel and allow to air dry. KILLS HIV, HBV AND HCV ON PRE-CLEANED ENVIRONMENTAL SURFACES/OBJECTS PREVIOUSLY SOILED WITH BLOOD/BODY FLUIDS in healthcare settings or other settings in which there is an expected likelihood of soiling of inanimate surfaces/objects with blood/body fluids, and in which the surfaces/objects likely to be soiled with blood/body fluids can be associated with the potential for transmission of Human Immunodeficiency Virus Type 1 (HIV-1) (associated with AIDS), Hepatitis B Virus (HBV), and Hepatitis C Virus (HCV). Special Instructions for Cleaning and Decontamination Against HIV-1 (AIDS Virus), HBV and HCV on Surfaces/Objects Soiled with Blood/Body Fluids. Personal Protection: When handling items soiled with blood or body fluids, use disposable gloves, gowns, masks, and eye covering. Cleaning Procedure: Blood and other body fluids must be thoroughly cleaned from surfaces and objects before applying this product. Contact Time: Let stand for one minute. For all other organisms, see directions for contact times. Disposal of Infectious Materials: Use disposable impervious gloves, gowns, masks and eye coverings. Blood and other body fluids must be autoclaved and disposed of according to local regulations for infectious waste disposal. This product is not to be used as a terminal sterilant/high level disinfectant on any surface or instrument that (1) is introduced directly into the human body, either into or in contact with the bloodstream or normally sterile areas of the body, or (2) contacts intact mucous membranes but which does not ordinarily penetrate the blood barrier or otherwise enter normally sterile areas of the body. This product may be used to preclean or decontaminate critical or semi-critical medical devices prior to sterilization or high level disinfection. R0964030 PEEL 56392-7_PPD_HC_BLGRM_Clnr_22oz_R0964030.indd 2 8/6/14 11:20 AM

EPA Reg. No. 56392-7 Clorox Healthcare Bleach Germicidal Cleaner [22 oz] Page 3 of 3 STORAGE AND DISPOSAL: Store this product in a cool, dry area, away from direct sunlight and heat. Refillable container. Refill empty Clorox Healthcare Bleach Germicidal Cleaner spray container only from Clorox Healthcare Bleach Germicidal Cleaner refill bottle. Cleaning before refilling is the responsibility of the refiller. Take care to update expiration date on refillable bottle and replace bottle if it becomes worn or damaged. Do not reuse this container for any other purpose. Rinse container with water prior to disposal. Cleaning the container before final disposal is the responsibility of the person disposing of the container. When discarding container, place in trash collection or take to recycling center. Do not contaminate water, food or feed by storage and disposal. bacteria, viruses & fungi in 1 MINUTE on hard, nonporous surfaces: ORGANISMS Escherichia coli - New Delhi Klebsiella pneumoniae Carbapenem resistant Klebsiella Klebsiella pneumoniae - New Delhi Methicillin resistant Staphylococcus Enterobacter cloacae - New Delhi aureus (MRSA) Multi-drug resistant Enterococcus ESBL (Extended Spectrum Beta faecium Lactamase) producing Escherichia coli Proteus mirabilis ESBL (Extended Spectrum Beta Lactamase) Pseudomonas aeruginosa producing Klebsiella pneumoniae Salmonella enterica Avian Influenza A (H3N2) Virus Canine Parvovirus Feline Panleukopenia Virus Hepatitis A Virus (HAV) Hepatitis B Virus (HBV) Trichophyton mentagrophytes (Athlete s Foot Fungus) Candida albicans Hepatitis C Virus (HCV) Herpes Simplex Virus Type 2 (HSV-2) HIV-1 (AIDS Virus) Influenza A H1N1 Influenza A Virus Serratia marcescens Streptococcus pyogenes Stenotrophomonas maltophilia Vancomycin intermediate resistant Staphylococcus aureus (VISA) Enterococcus faecium (VRE) Norovirus Poliovirus Type 1 (Mahoney Strain) Rhinovirus Type 37 Rotavirus Follow special instructions for cleaning prior to disinfection. Efficacy tests have demonstrated that this product is an effective bactericide, virucide and fungicide in the presence of organic soil (5% blood serum). SURFACES May be used on hard, nonporous surfaces such as: stainless steel nonporous vinyl glazed porcelain glazed ceramic tile laminated plastic countertops glass hard plastics fiberglass (sealed) surfaces Medical hard, nonporous surfaces: autoclaves external surfaces of blood glucose monitors dialysis machines external surfaces of gurneys medical equipment mammography equipment IV poles plastic mattress covers exam tables phlebotomy trays bed railing reception counters Dental hard, nonporous surfaces: chairs operatory hard counters surfaces light lens covers USE SITES Medical: ambulance blood banks central service critical care units dialysis clinics emergency rooms exam rooms home health care Dental: dental clinics labs hospitals intensive care units laboratories neonatal nurseries nurses stations nursing homes operating rooms orthopedic clinics external surfaces of respiratory equipment stretchers external surfaces of ultrasound transducers and probes behind and under wash basins** wheelchairs Miscellaneous hard, nonporous surfaces: changing tables doorknobs highchairs hand railings playpens Miscellaneous: correctional facilities day care centers funeral homes health club facilities recreational centers outpatient clinics patient rooms physical therapy rooms physician offices radiology recovery rooms respiratory therapy areas surgery rooms restrooms schools For any use site that includes electronics, refer to manufacturers instructions before use. **hard, nonporous surfaces of R0964030 56392-7_PPD_HC_BLGRM_Clnr_22oz_R0964030.indd 3 8/6/14 11:20 AM

EPA Reg. No. 56392-7 Clorox Healthcare Bleach Germicidal Cleaner [32 oz] Page 1 of 3 99.99% Bacteria, Viruses, MANTÉNGASE FUERA DEL ALCANCE DE LOS NIÑOS PRECAUCIÓN: LEA LAS INSTRUCCIONES Y PRECAUCIONES COMPLETAS EN LOS PANELES DE ATRÁS. Si usted no entiende la etiqueta, busque a alguien para que se la explique a usted en detalle. Clostridium difficile Bleach Germicidal Cleaner Limpiador Germicida con Blanqueador 1 QT (32 FL OZ) 946 ml OTHER INGREDIENTS:...99.35% TOTAL:...100.00% INGREDIENTE ACTIVO: Hipoclorito de Sodio...0,65% OTROS INGREDIENTES:...99,35% TOTAL:...100,00% No contiene fósforo. NI-25245 Peel for Additional Directions Multipurpose, broad spectrum cleaner disinfectant for use in healthcare and other areas where control of cross contamination is required, especially during outbreaks of Clostridium difficile and other Healthcare Associated Infections (HAIs) listed on this label. Meets OSHA Bloodborne Pathogen Standards. May be used for instrument pre-cleaning and disinfection of non-critical instruments. DIRECTIONS FOR USE: It is a violation of Federal Law to use this product in a manner inconsistent with its labeling. Always refer to manufacturer s care instructions before using on equipment or devices. TO REFILL: Remove: Remove trigger sprayer from empty bottle. Pour: Unscrew cap on refill and pour contents directly into empty bottle. Use: Replace trigger sprayer and use as you normally would. To Clean, Disinfect and Deodorize in One Step: Spray 6" 8" from surface until surface is completely wet. To disinfect, let stand for one minute. Wipe with a clean, damp cloth or paper towel or allow to air dry. For food contact surfaces, rinse with potable water. For all other surfaces no rinsing is required. Gross soil must be removed prior to disinfecting. To Clean: Follow directions above or apply with a clean cloth, mop, or sponge saturated with Clorox Healthcare Bleach Germicidal Cleaner until surface is completely wet. (When applying with a saturated cloth or sponge, gloves should be worn.) No standing time is required. If streaking is observed, wipe with a clean, damp cloth or paper towel. PRECAUTIONARY STATEMENTS: HAZARDS TO HUMANS AND DOMESTIC ANIMALS. Causes moderate eye irritation. Avoid contact with eyes or clothing. Wash thoroughly with soap and water after handling. FIRST AID: If in Eyes: Hold eye open and rinse slowly and gently with water for 15 20 minutes. If present, remove contact lenses after the first 5 minutes, then continue rinsing eye. Call a poison control center or doctor for further treatment advice. Have the product container or label with you when calling a poison control center or doctor or going for treatment. PHYSICAL OR CHEMICAL HAZARDS: Do not use this product with ammonia or acids such as vinegar, rust removers, or toilet bowl cleaners. This product not intended for use on fabrics. For MSDS information, please go to www.cloroxhealthcare.com. A list of this product s ingredients is available at www.ingredientsinside.com. Una lista de los ingredientes de este producto se encuentra disponible en www.ingredientsinside.com. Mfd. for Clorox Professional Products Company, 1221 Broadway, Oakland, CA 94612. Clorox Healthcare is a registered trademark of The Clorox Company. 2014 Made in the U.S.A. EPA Reg. No. 56392-7. EPA Est. No. 8251-OH-1 (Q6); 5813-GA-1 (A4); GA-2 (VG). Beginning of batch code indicates Est. No. 0 00000 00000 0 R0920050 NI-25246 56392-7_PPD_HC_BLGRM_Clnr_32oz_R0920050.indd 1 8/6/14 11:21 AM

EPA Reg. No. 56392-7 Clorox Healthcare Bleach Germicidal Cleaner [32 oz] Page 2 of 3 Para Limpiar, Desinfectar y Desodorizar en Un Sólo Paso: Rocíe a una distancia de 6 8 pulgadas de la superficie hasta que esté completamente mojada. Para desinfectar, deje reposar un minuto. Limpie con un paño o con una toalla de papel limpia y húmeda o deje secar al aire. Para superficies que entren en contacto con los alimentos, enjuague con agua potable. Para las demás superficies no se requiere enjuague. El exceso de mugre se debe quitar antes de desinfectar. Para Limpiar: Siga las instrucciones de arriba o aplique con un paño, esponja o trapeador limpio y saturado con el Limpiador Germicida con Blanqueador Clorox Healthcare hasta que la superficie esté completamente mojada. (Se deben usar guantes cuando se aplique con un paño o esponja saturada.) No requiere tiempo de reposo. Si se observan rayas, limpie con un paño o con una toalla de papel limpia y húmeda. DECLARACIONES PREVENTIVAS: RIESGOS PARA LOS SERES HUMANOS Y ANIMALES DOMÉSTICOS. PRECAUCIÓN: Causa irritación moderada a los ojos. Evite el contacto con los ojos o la ropa. Lávese bien con agua y jabón después de usar. PRIMEROS AUXILIOS: Contacto con los Ojos: Mantenga los ojos abiertos y enjuague con agua lentamente, con cuidado, durante 15 20 minutos. Si hay lentes de contacto, retírelos después de los primeros 5 minutos, luego continúe enjuagando los ojos. Llame a un médico o a un centro de control de envenenamiento para obtener más asesoría sobre el tratamiento. Cuando llame a un centro de control de envenenamiento o a un médico, o intente obtener tratamiento, tenga a la mano el envase o la etiqueta del producto. RIESGOS FÍSICOS O QUÍMICOS: No use este producto con amoníaco ni ácidos como vinagre, removedores de óxido o productos para limpiar el inodoro. Este producto no está hecho para usarse en telas. DIRECTIONS FOR USE continued: Special Instructions for Cleaning Prior to Disinfection against Clostridium difficile. Personal Protection: Wear appropriate barrier protection such as gloves, gowns, masks, or eye covering. Cleaning Procedure: Fecal matter/waste must be thoroughly cleaned from surfaces/objects before disinfection by application with a clean cloth, mop, and/or sponge saturated with this product. Cleaning is to include vigorous wiping and/or scrubbing, until all visible soil is removed. Special attention is needed for high-touch surfaces. Surfaces in patient rooms are to be cleaned in an appropriate manner, such as from right to left or left to right, on horizontal surfaces, and top to bottom, on vertical surfaces, to minimize spreading of the. Restrooms are to be cleaned last. Do not reuse soiled cloths. Infectious Materials Disposal: Materials used in the cleaning process that may contain feces/wastes are to be disposed of immediately in accordance with local regulations for infectious materials disposal. Disinfection Procedure: Spray 6" 8" from surface until surface is completely wet. Let stand for 5 minutes. Wipe with a clean, damp cloth or paper towel or allow to air dry. To Preclean Instruments Prior to Terminal Sterilization/High Level Disinfection: As a pre-cleaning spray Place instruments into a suitable container. Spray Clorox Healthcare Bleach Germicidal Cleaner onto instruments to thoroughly wet all surfaces. Let stand for up to 10 minutes. Rinse instruments. As a pre-cleaning immersion solution Fill appropriate size container with a sufficient amount of Clorox Healthcare Bleach Germicidal Cleaner to completely submerge instruments. Place instruments into the container of Clorox Healthcare Bleach Germicidal Cleaner, cover, and allow to soak for up to 10 minutes. Remove and rinse, and follow with an appropriate cleaning and disinfecting process. Change solution daily. As a manual instrument cleaner Thoroughly pre-rinse dirty instruments under running water to remove visible, gross debris. Immerse pre-rinsed instruments into an appropriate size container filled with Clorox Healthcare Bleach Germicidal Cleaner. Scrub instruments using a stiff bristle brush until visibly clean. Submerge instruments while scrubbing. Rinse instruments thoroughly. Change solution daily. Follow with an appropriate disinfection process. Cleaning of critical and semi-critical devices must be followed by an appropriate terminal sterilization/high-level disinfection process. To Disinfect Non-Critical, Pre-cleaned Instruments: Instruments must be thoroughly pre-cleaned to remove excess organic debris, rinsed, and rough dried. (Clean and rinse lumens of hollow instruments before filling with Clorox Healthcare Bleach Germicidal Cleaner or before immersion.) Immersion method Using a soaking tray, immerse instruments into Clorox Healthcare Bleach Germicidal Cleaner and let stand for one minute. Remove and wipe with a clean, damp cloth or paper towel and allow to air dry. Change solution for each use. Spray method Spray all surfaces of instruments with Clorox Healthcare Bleach Germicidal Cleaner until thoroughly wet. Let stand for one minute. To kill Clostridium difficile (), let stand for five minutes. Wipe with a clean, damp cloth or paper towel and allow to air dry. KILLS HIV, HBV AND HCV ON PRE-CLEANED ENVIRONMENTAL SURFACES/OBJECTS PREVIOUSLY SOILED WITH BLOOD/BODY FLUIDS in healthcare settings or other settings in which there is an expected likelihood of soiling of inanimate surfaces/objects with blood/body fluids, and in which the surfaces/objects likely to be soiled with blood/body fluids can be associated with the potential for transmission of Human Immunodeficiency Virus Type 1 (HIV-1) (associated with AIDS), Hepatitis B Virus (HBV), and Hepatitis C Virus (HCV). Special Instructions for Cleaning and Decontamination Against HIV-1 (AIDS Virus), HBV and HCV on Surfaces/Objects Soiled with Blood/Body Fluids. Personal Protection: When handling items soiled with blood or body fluids, use disposable gloves, gowns, masks, and eye covering. Cleaning Procedure: Blood and other body fluids must be thoroughly cleaned from surfaces and objects before applying this product. Contact Time: Let stand for one minute. For all other organisms, see directions for contact times. Disposal of Infectious Materials: Use disposable impervious gloves, gowns, masks and eye coverings. Blood and other body fluids must be autoclaved and disposed of according to local regulations for infectious waste disposal. This product is not to be used as a terminal sterilant/high level disinfectant on any surface or instrument that (1) is introduced directly into the human body, either into or in contact with the bloodstream or normally sterile areas of the body, or (2) contacts intact mucous membranes but which does not ordinarily penetrate the blood barrier or otherwise enter normally sterile areas of the body. This product may be used to preclean or decontaminate critical or semi-critical medical devices prior to sterilization or high level disinfection. R0920050 PEEL 56392-7_PPD_HC_BLGRM_Clnr_32oz_R0920050.indd 2 8/6/14 11:21 AM

EPA Reg. No. 56392-7 Clorox Healthcare Bleach Germicidal Cleaner [32 oz] Page 3 of 3 STORAGE AND DISPOSAL: Store this product in a cool, dry area, away from direct sunlight and heat. Refillable container. Refill empty Clorox Healthcare Bleach Germicidal Cleaner spray container only from Clorox Healthcare Bleach Germicidal Cleaner refill bottle. Cleaning before refilling is the responsibility of the refiller. Take care to update expiration date on refillable bottle and replace bottle if it becomes worn or damaged. Do not reuse this container for any other purpose. Rinse container with water prior to disposal. Cleaning the container before final disposal is the responsibility of the person disposing of the container. When discarding container, place in trash collection or take to recycling center. Do not contaminate water, food or feed by storage and disposal. bacteria, viruses & fungi in 1 MINUTE on hard, nonporous surfaces: ORGANISMS Escherichia coli - New Delhi Klebsiella pneumoniae Carbapenem resistant Klebsiella Klebsiella pneumoniae - New Delhi Methicillin resistant Staphylococcus Enterobacter cloacae - New Delhi aureus (MRSA) Multi-drug resistant Enterococcus ESBL (Extended Spectrum Beta faecium Lactamase) producing Escherichia coli Proteus mirabilis ESBL (Extended Spectrum Beta Lactamase) Pseudomonas aeruginosa producing Klebsiella pneumoniae Salmonella enterica Avian Influenza A (H3N2) Virus Canine Parvovirus Feline Panleukopenia Virus Hepatitis A Virus (HAV) Hepatitis B Virus (HBV) Trichophyton mentagrophytes (Athlete s Foot Fungus) Candida albicans Hepatitis C Virus (HCV) Herpes Simplex Virus Type 2 (HSV-2) HIV-1 (AIDS Virus) Influenza A H1N1 Influenza A Virus Serratia marcescens Streptococcus pyogenes Stenotrophomonas maltophilia Vancomycin intermediate resistant Staphylococcus aureus (VISA) Enterococcus faecium (VRE) Norovirus Poliovirus Type 1 (Mahoney Strain) Rhinovirus Type 37 Rotavirus Follow special instructions for cleaning prior to disinfection. Efficacy tests have demonstrated that this product is an effective bactericide, virucide and fungicide in the presence of organic soil (5% blood serum). SURFACES May be used on hard, nonporous surfaces such as: stainless steel nonporous vinyl glazed porcelain glazed ceramic tile laminated plastic countertops glass hard plastics fiberglass (sealed) surfaces Medical hard, nonporous surfaces: autoclaves external surfaces of blood glucose monitors dialysis machines external surfaces of gurneys medical equipment mammography equipment IV poles plastic mattress covers exam tables phlebotomy trays bed railing reception counters Dental hard, nonporous surfaces: chairs operatory hard counters surfaces light lens covers USE SITES Medical: ambulance blood banks central service critical care units dialysis clinics emergency rooms exam rooms home health care Dental: dental clinics labs hospitals intensive care units laboratories neonatal nurseries nurses stations nursing homes operating rooms orthopedic clinics external surfaces of respiratory equipment stretchers external surfaces of ultrasound transducers and probes behind and under wash basins** wheelchairs Miscellaneous hard, nonporous surfaces: changing tables doorknobs highchairs hand railings playpens Miscellaneous: correctional facilities day care centers funeral homes health club facilities recreational centers outpatient clinics patient rooms physical therapy rooms physician offices radiology recovery rooms respiratory therapy areas surgery rooms restrooms schools For any use site that includes electronics, refer to manufacturers instructions before use. **hard, nonporous surfaces of R0920050 56392-7_PPD_HC_BLGRM_Clnr_32oz_R0920050.indd 3 8/6/14 11:21 AM

DIRECTIONS FOR USE: It is a violation of Federal Law to use this product in a manner inconsistent with its labeling. Always refer to manufacturer s care instructions before using on equipment or devices. To Clean, Disinfect, and Deodorize in One Step: Spray 6" 8" from surface until surface is completely wet. To disinfect, let stand for one minute. Wipe with a clean, damp cloth or paper towel or allow to air dry. For food contact surfaces, rinse with potable water. For all other surfaces no rinsing is required. Gross soil must be removed prior to disinfecting. To Clean: Follow directions above or apply with a clean cloth, mop, or sponge saturated with Clorox Healthcare Bleach Germicidal Cleaner until surface is completely wet. (When applying with a saturated cloth or sponge, gloves should be worn.) No standing time is required. If streaking is observed, wipe with a clean, damp cloth or paper towel. Special Instructions for Cleaning Prior to Disinfection against Clostridium difficile. Personal Protection: Wear appropriate barrier protection such as gloves, gowns, masks, or eye covering. Cleaning Procedure: Fecal matter/waste must be thoroughly cleaned from surfaces/objects before disinfection by application with a clean cloth, mop, and/or sponge saturated with this product. Cleaning is to include vigorous wiping and/or scrubbing, until all visible soil is removed. Special attention is needed for high-touch surfaces. Surfaces in patient rooms are to be cleaned in an appropriate manner, such as from right to left or left to right, on horizontal surfaces, and top to bottom, on vertical surfaces, to minimize spreading of the. Restrooms are to be cleaned last. Do not reuse soiled cloths. Infectious Materials Disposal: Materials used in the cleaning process that may contain feces/wastes are to be disposed of immediately in accordance with local regulations for infectious materials disposal. Disinfection Procedure: Spray 6" 8" from surface until surface is completely wet. Let stand for 5 minutes. Wipe with a clean, damp cloth or paper towel or allow to air dry. To Preclean Instruments Prior to Terminal Sterilization/High Level Disinfection: As a pre-cleaning spray Place instruments into a suitable container. Spray Clorox Healthcare Bleach Germicidal Cleaner onto instruments to thoroughly wet all surfaces. Let stand for up to 10 minutes. Rinse instruments. As a pre-cleaning immersion solution Fill appropriate size container with a sufficient amount of Clorox Healthcare Bleach Germicidal Cleaner to completely submerge instruments. Place instruments into the container of Clorox Healthcare Bleach Germicidal Cleaner, cover, and allow to soak for up to 10 minutes. Remove and rinse, and follow with an appropriate cleaning and disinfecting process. Change solution daily. As a manual instrument cleaner Thoroughly pre-rinse dirty instruments under running water to remove visible, gross debris. Immerse pre-rinsed instruments into an appropriate size container filled with Clorox Healthcare Bleach Germicidal Cleaner. Scrub instruments using a stiff bristle brush until visibly clean. Submerge instruments while scrubbing. Rinse instruments thoroughly. Change solution daily. Follow with an appropriate disinfection process. Cleaning of critical and semi-critical devices must be followed by an appropriate terminal sterilization/high level disinfection process. To Disinfect Non-Critical, Pre-Cleaned Instruments: Instruments must be thoroughly pre-cleaned to remove excess organic debris, rinsed, and rough dried. (Clean and rinse lumens of hollow instruments before filling with Clorox Healthcare Bleach Germicidal Cleaner or before immersion.) Immersion method Using a soaking tray, immerse instruments into Clorox Healthcare Bleach Germicidal Cleaner and let stand for one minute. Remove and wipe with a clean, damp cloth or paper towel and allow to air dry. Change solution for each use. Spray method Spray all surfaces of instruments with Clorox Healthcare Bleach Germicidal Cleaner until thoroughly wet. Let stand for one minute. To kill Clostridium difficile (), let stand for five minutes. Wipe with a clean, damp cloth or paper towel and allow to air dry. KILLS HIV, HBV, AND HCV ON PRE-CLEANED ENVIRONMENTAL SURFACES/OBJECTS PREVIOUSLY SOILED WITH BLOOD/BODY FLUIDS in healthcare settings or other settings in which there is an expected likelihood of soiling of inanimate surfaces/objects with blood/body fluids, and in which the surfaces/objects likely to be soiled with blood/body fluids can be associated with the potential for transmission of Human Immunodeficiency Virus Type 1 (HIV-1) (associated with AIDS), Hepatitis B Virus (HBV), and Hepatitis C Virus (HCV). Special Instructions for Cleaning and Decontamination Against HIV-1 (AIDS Virus), HBV and HCV on Surfaces/Objects Soiled with Blood/Body Fluids. Personal Protection: When handling items soiled with blood or body fluids, use disposable gloves, gowns, masks, and eye covering. Cleaning Procedure: Blood and other body fluids must be thoroughly cleaned from surfaces and objects before applying this product. Contact Time: Let stand for one minute. For all other organisms, see directions for contact times. Disposal of Infectious Materials: Use disposable impervious gloves, gowns, masks and eye coverings. Blood and other body fluids must be autoclaved and disposed of according to local regulations for infectious waste disposal. This product is not to be used as a terminal sterilant/high level disinfectant on any surface or instrument that (1) is introduced directly into the human body, either into or in contact with the bloodstream or normally sterile areas of the body, or (2) contacts intact mucous membranes but which does not ordinarily penetrate the blood barrier or otherwise enter normally sterile areas of the body. This product may be used to preclean or decontaminate critical or semi-critical medical devices prior to sterilization or high level disinfection. Multipurpose, broad spectrum cleaner disinfectant for use in healthcare and other areas where control of cross contamination is required, especially during outbreaks of Clostridium difficile and other Healthcare Associated Infections (HAIs) listed on this label. Meets OSHA Bloodborne Pathogen Standards. May be used for instrument pre-cleaning and disinfection of non-critical instruments. SURFACES: May be used on hard, non-porous surfaces such as stainless steel, glazed ceramic tile, hard plastics, non-porous vinyl, laminated plastic countertops, fiberglass (sealed) surfaces, glazed porcelain, and glass. Medical hard, non-porous surfaces: autoclaves, blood glucose monitors, external surfaces of medical equipment, IV poles, exam tables, bed railing, external surfaces of dialysis machines, gurneys, mammography equipment, plastic mattress covers, external surfaces of respiratory equipment, stretchers, external surfaces of ultrasound transducers and probes, and wheelchairs. Dental hard, non-porous surfaces: chairs, counters, operatory hard surfaces, and light lens covers. Miscellaneous hard, non-porous surfaces: doorknobs, hand railings. USE SITES: Medical ambulance, critical care units, emergency rooms, exam rooms, hospitals, intensive care units, nurses stations, patient rooms, physician offices, and surgery rooms. Dental dental clinics, labs. 99.99% Bacteria, Viruses, Si usted no entiende la etiqueta, busque a alguien para que se la explique a usted en detalle. Clostridium difficile OTHER INGREDIENTS:...99.35% TOTAL:...100.00% ORGANISMS: Escherichia coli - New Delhi Klebsiella pneumoniae Carbapenem resistant Klebsiella Klebsiella pneumoniae - New Delhi Methicillin resistant Staphylococcus Enterobacter cloacae - New Delhi aureus (MRSA) Multi-drug resistant Enterococcus ESBL (Extended Spectrum Beta faecium Lactamase) producing Escherichia coli Proteus mirabilis ESBL (Extended Spectrum Beta Lactamase) Pseudomonas aeruginosa producing Klebsiella pneumoniae Salmonella enterica Avian Influenza A (H3N2) Virus Hepatitis C Virus (HCV) Canine Parvovirus Herpes Simplex Virus Type 2 Feline Panleukopenia Virus (HSV-2) Hepatitis A Virus (HAV) HIV-1 (AIDS Virus) Hepatitis B Virus (HBV) Influenza A H1N1 Trichophyton mentagrophytes Candida albicans (Athlete s Foot Fungus) Follow special instructions for cleaning prior to disinfection. Serratia marcescens Streptococcus pyogenes Stenotrophomonas maltophilia Vancomycin intermediate resistant Staphylococcus aureus (VISA) Enterococcus faecium (VRE) Influenza A Virus Norovirus Poliovirus Type 1 (Mahoney Strain) Rhinovirus Type 37 Rotavirus FIRST AID: If in Eyes: Hold eye open and rinse slowly and gently with water for 15 20 minutes. If present, remove contact lenses after the first 5 minutes, then continue rinsing eye. Call a poison control center or doctor for further treatment advice. Have the product container or label with you when calling a poison control center or doctor, or going for treatment. PHYSICAL OR CHEMICAL HAZARDS: Do not use this product with ammonia or acids such as vinegar, rust removers, or toilet bowl cleaners. This product not intended for use on fabrics. Cleaning before refilling is the responsibility of the refiller. Take care to update expiration date on refillable bottle and replace bottle if it becomes worn or damaged. Do not reuse this container for any other purpose. Rinse container with water prior to disposal. Cleaning the container before final disposal is the responsibility of the person disposing of the container. When discarding container, place in trash collection or take to recycling center. Do not contaminate water, food, or feed by storage and disposal. For MSDS information please go to: www.cloroxhealthcare.com. A list of this product s ingredients is available at www.ingredientsinside.com. Mfd. for Clorox Professional Products Company, 1221 Broadway, Oakland, CA 94612. Clorox Healthcare is a registered trademark of The Clorox Company. 2014 Made in the U.S.A. EPA Reg. No. 56392-7. EPA Est. No. 8251-OH-1 (Q6). Beginning of batch code indicates Est. No. EPA Reg. No. 56392-7 Clorox Healthcare Bleach Germicidal Cleaner [32 oz] Page 1 of 2 Bleach Germicidal Cleaner 99.99% Bacteria, Viruses, Clostridium difficile Si usted no entiende la etiqueta, busque a alguien para que se la explique a usted en detalle. OTHER INGREDIENTS:...99.35% TOTAL:...100.00% Shown on page 2 1 QT (32 FL OZ) 946 ml R0965020 NI-25249 Bleach Germicidal Cleaner 1 QT (32 FL OZ) 946 ml NI-25249 For any use site that includes electronics refer to manufacturers instructions before use. Efficacy tests have demonstrated that this product is an effective bactericide, virucide and fungicide in the presence of organic soil (5% blood serum). PRECAUTIONARY STATEMENTS: HAZARDS TO HUMANS AND DOMESTIC ANIMALS. Causes moderate eye irritation. Avoid contact with eyes or clothing. Wash thoroughly with soap and water after handling. STORAGE AND DISPOSAL: Store this product in a cool, dry area, away from direct sunlight and heat. Refillable container. Refill empty Clorox Healthcare Bleach Germicidal Cleaner spray container only from Clorox Healthcare Bleach Germicidal Cleaner refill bottle. 56392-7_PPD_HC_BLGRM_Clnr_32ozPull_R0965020.indd 1 8/6/14 11:21 AM

EPA Reg. No. 56392-7 Clorox Healthcare Bleach Germicidal Cleaner [32 oz] Page 2 of 2 DIRECTIONS FOR USE: It is a violation of Federal Law to use this product in a manner inconsistent with its labeling. Always refer to manufacturer s care instructions before using on equipment or devices. To Clean, Disinfect, and Deodorize in One Step: Spray 6" 8" from surface until surface is completely wet. To disinfect, let stand for one minute. Wipe with a clean, damp cloth or paper towel or allow to air dry. For food contact surfaces, rinse with potable water. For all other surfaces no rinsing is required. Gross soil must be removed prior to disinfecting. To Clean: Follow directions above or apply with a clean cloth, mop, or sponge saturated with Clorox Healthcare Bleach Germicidal Cleaner until surface is completely wet. (When applying with a saturated cloth or sponge, gloves should be worn.) No standing time is required. If streaking is observed, wipe with a clean, damp cloth or paper towel. Special Instructions for Cleaning Prior to Disinfection against Clostridium difficile. Personal Protection: Wear appropriate barrier protection such as gloves, gowns, masks, or eye covering. Cleaning Procedure: Fecal matter/waste must be thoroughly cleaned from surfaces/objects before disinfection by application with a clean cloth, mop, and/or sponge saturated with this product. Cleaning is to include vigorous wiping and/or scrubbing, until all visible soil is removed. Special attention is needed for high-touch surfaces. Surfaces in patient rooms are to be cleaned in an appropriate manner, such as from right to left or left to right, on horizontal surfaces, and top to bottom, on vertical surfaces, to minimize spreading of the. Restrooms are to be cleaned last. Do not reuse soiled cloths. Infectious Materials Disposal: Materials used in the cleaning process that may contain feces/wastes are to be disposed of immediately in accordance with local regulations for infectious materials disposal. Disinfection Procedure: Spray 6" 8" from surface until surface is completely wet. Let stand for 5 minutes. Wipe with a clean, damp cloth or paper towel or allow to air dry. To Preclean Instruments Prior to Terminal Sterilization/High Level Disinfection: As a pre-cleaning spray Place instruments into a suitable container. Spray Clorox Healthcare Bleach Germicidal Cleaner onto instruments to thoroughly wet all surfaces. Let stand for up to 10 minutes. Rinse instruments. As a pre-cleaning immersion solution Fill appropriate size container with a sufficient amount of Clorox Healthcare Bleach Germicidal Cleaner to completely submerge instruments. Place instruments into the container of Clorox Healthcare Bleach Germicidal Cleaner, cover, and allow to soak for up to 10 minutes. Remove and rinse, and follow with an appropriate cleaning and disinfecting process. Change solution daily. As a manual instrument cleaner Thoroughly pre-rinse dirty instruments under running water to remove visible, gross debris. Immerse pre-rinsed instruments into an appropriate size container filled with Clorox Healthcare Bleach Germicidal Cleaner. Scrub instruments using a stiff bristle brush until visibly clean. Submerge instruments while scrubbing. Rinse instruments thoroughly. Change solution daily. Follow with an appropriate disinfection process. Cleaning of critical and semi-critical devices must be followed by an appropriate terminal sterilization/high level disinfection process. To Disinfect Non-Critical, Pre-Cleaned Instruments: Instruments must be thoroughly pre-cleaned to remove excess organic debris, rinsed, and rough dried. (Clean and rinse lumens of hollow instruments before filling with Clorox Healthcare Bleach Germicidal Cleaner or before immersion.) Immersion method Using a soaking tray, immerse instruments into Clorox Healthcare Bleach Germicidal Cleaner and let stand for one minute. Remove and wipe with a clean, damp cloth or paper towel and allow to air dry. Change solution for each use. Spray method Spray all surfaces of instruments with Clorox Healthcare Bleach Germicidal Cleaner until thoroughly wet. Let stand for one minute. To kill Clostridium difficile (), let stand for five minutes. Wipe with a clean, damp cloth or paper towel and allow to air dry. KILLS HIV, HBV, AND HCV ON PRE-CLEANED ENVIRONMENTAL SURFACES/OBJECTS PREVIOUSLY SOILED WITH BLOOD/BODY FLUIDS in healthcare settings or other settings in which there is an expected likelihood of soiling of inanimate surfaces/objects with blood/body fluids, and in which the surfaces/objects likely to be soiled with blood/body fluids can be associated with the potential for transmission of Human Immunodeficiency Virus Type 1 (HIV-1) (associated with AIDS), Hepatitis B Virus (HBV), and Hepatitis C Virus (HCV). Special Instructions for Cleaning and Decontamination Against HIV-1 (AIDS Virus), HBV and HCV on Surfaces/Objects Soiled with Blood/Body Fluids. Personal Protection: When handling items soiled with blood or body fluids, use disposable gloves, gowns, masks, and eye covering. Cleaning Procedure: Blood and other body fluids must be thoroughly cleaned from surfaces and objects before applying this product. Contact Time: Let stand for one minute. For all other organisms, see directions for contact times. Disposal of Infectious Materials: Use disposable impervious gloves, gowns, masks and eye coverings. Blood and other body fluids must be autoclaved and disposed of according to local regulations for infectious waste disposal. This product is not to be used as a terminal sterilant/high level disinfectant on any surface or instrument that (1) is introduced directly into the human body, either into or in contact with the bloodstream or normally sterile areas of the body, or (2) contacts intact mucous membranes but which does not ordinarily penetrate the blood barrier or otherwise enter normally sterile areas of the body. This product may be used to preclean or decontaminate critical or semi-critical medical devices prior to sterilization or high level disinfection. Multipurpose, broad spectrum cleaner disinfectant for use in healthcare and other areas where control of cross contamination is required, especially during outbreaks of Clostridium difficile and other Healthcare Associated Infections (HAIs) listed on this label. Meets OSHA Bloodborne Pathogen Standards. May be used for instrument pre-cleaning and disinfection of non-critical instruments. SURFACES: May be used on hard, non-porous surfaces such as stainless steel, glazed ceramic tile, hard plastics, non-porous vinyl, laminated plastic countertops, fiberglass (sealed) surfaces, glazed porcelain, and glass. Medical hard, non-porous surfaces: autoclaves, blood glucose monitors, external surfaces of medical equipment, IV poles, exam tables, bed railing, external surfaces of dialysis machines, gurneys, mammography equipment, plastic mattress covers, external surfaces of respiratory equipment, stretchers, external surfaces of ultrasound transducers and probes, and wheelchairs. Dental hard, non-porous surfaces: chairs, counters, operatory hard surfaces, and light lens covers. Miscellaneous hard, non-porous surfaces: doorknobs, hand railings. USE SITES: Medical ambulance, critical care units, emergency rooms, exam rooms, hospitals, intensive care units, nurses stations, patient rooms, physician offices, and surgery rooms. Dental dental clinics, labs. NI-25249 For any use site that includes electronics refer to manufacturers instructions before use. Efficacy tests have demonstrated that this product is an effective bactericide, virucide and fungicide in the presence of organic soil (5% blood serum). ORGANISMS: Carbapenem resistant Klebsiella Enterobacter cloacae - New Delhi ESBL (Extended Spectrum Beta Lactamase) producing Escherichia coli ESBL (Extended Spectrum Beta Lactamase) producing Klebsiella pneumoniae Avian Influenza A (H3N2) Virus Canine Parvovirus Feline Panleukopenia Virus Hepatitis A Virus (HAV) Hepatitis B Virus (HBV) Escherichia coli - New Delhi Klebsiella pneumoniae Klebsiella pneumoniae - New Delhi Methicillin resistant Staphylococcus aureus (MRSA) Multi-drug resistant Enterococcus faecium Proteus mirabilis Pseudomonas aeruginosa Salmonella enterica Hepatitis C Virus (HCV) Herpes Simplex Virus Type 2 (HSV-2) HIV-1 (AIDS Virus) Influenza A H1N1 Trichophyton mentagrophytes Candida albicans (Athlete s Foot Fungus) Follow special instructions for cleaning prior to disinfection. PRECAUTIONARY STATEMENTS: HAZARDS TO HUMANS AND DOMESTIC ANIMALS. Causes moderate eye irritation. Avoid contact with eyes or clothing. Wash thoroughly with soap and water after handling. FIRST AID: If in Eyes: Hold eye open and rinse slowly and gently with water for 15 20 minutes. If present, remove contact lenses after the first 5 minutes, then continue rinsing eye. Call a poison control center or doctor for further treatment advice. Have the product container or label with you when calling a poison control center or doctor, or going for treatment. PHYSICAL OR CHEMICAL HAZARDS: Do not use this product with ammonia or acids such as vinegar, rust removers, or toilet bowl cleaners. This product not intended for use on fabrics. STORAGE AND DISPOSAL: Store this product in a cool, dry area, away from direct sunlight and heat. Refillable container. Refill empty Clorox Healthcare Bleach Germicidal Cleaner spray container only from Clorox Healthcare Bleach Germicidal Cleaner refill bottle. Cleaning before refilling is the responsibility of the refiller. Take care to update expiration date on refillable bottle and replace bottle if it becomes worn or damaged. Do not reuse this container for any other purpose. Rinse container with water prior to disposal. Cleaning the container before final disposal is the responsibility of the person disposing of the container. When discarding container, place in trash collection or take to recycling center. Do not contaminate water, food, or feed by storage and disposal. For MSDS information please go to: www.cloroxhealthcare.com. A list of this product s ingredients is available at www.ingredientsinside.com. Mfd. for Clorox Professional Products Company, 1221 Broadway, Oakland, CA 94612. Clorox Healthcare is a registered trademark of The Clorox Company. 2014 Made in the U.S.A. EPA Reg. No. 56392-7. EPA Est. No. 8251-OH-1 (Q6). Beginning of batch code indicates Est. No. R0965020 Serratia marcescens Streptococcus pyogenes Stenotrophomonas maltophilia Vancomycin intermediate resistant Staphylococcus aureus (VISA) Enterococcus faecium (VRE) Influenza A Virus Norovirus Poliovirus Type 1 (Mahoney Strain) Rhinovirus Type 37 Rotavirus 56392-7_PPD_HC_BLGRM_Clnr_32ozPull_R0965020.indd 2 8/6/14 11:21 AM

DIRECTIONS FOR USE: It is a violation of Federal Law to use this product in a manner inconsistent with its labeling. Always refer to manufacturer s care instructions before using on equipment or devices. To Refill Spray Bottles: Remove trigger sprayer from empty bottle. Unscrew cap on refill and pour contents directly into empty bottle. Replace trigger sprayer and use as you normally would. To Clean, Disinfect, and Deodorize in One Step: Spray 6" 8" from surface until surface is completely wet. To disinfect, let stand for one minute. Wipe with a clean, damp cloth or paper towel or allow to air dry. For food contact surfaces, rinse with potable water. For all other surfaces no rinsing is required. Gross soil must be removed prior to disinfecting. To Clean: Follow directions above or apply with a clean cloth, mop, or sponge saturated with Clorox Healthcare Bleach Germicidal Cleaner until surface is completely wet. (When applying with a saturated cloth or sponge, gloves should be worn.) No standing time is required. If streaking is observed, wipe with a clean, damp cloth or paper towel. Special Instructions for Cleaning Prior to Disinfection against Clostridium difficile. Personal Protection: Wear appropriate barrier protection such as gloves, gowns, masks, or eye covering. Cleaning Procedure: Fecal matter/waste must be thoroughly cleaned from surfaces/objects before disinfection by application with a clean cloth, mop, and/or sponge saturated with this product. Cleaning is to include vigorous wiping and/or scrubbing, until all visible soil is removed. Special attention is needed for high-touch surfaces. Surfaces in patient rooms are to be cleaned in an appropriate manner, such as from right to left or left to right, on horizontal surfaces, and top to bottom, on vertical surfaces, to minimize spreading of the. Restrooms are to be cleaned last. Do not reuse soiled cloths. Infectious Materials Disposal: Materials used in the cleaning process that may contain feces/wastes are to be disposed of immediately in accordance with local regulations for infectious materials disposal. Disinfection Procedure: Spray 6" 8" from surface until surface is completely wet. Let stand for 5 minutes. Wipe with a clean, damp cloth or paper towel or allow to air dry. To Preclean Instruments Prior to Terminal Sterilization/High Level Disinfection: As a pre-cleaning spray Place instruments into a suitable container. Spray Clorox Healthcare Bleach Germicidal Cleaner onto instruments to thoroughly wet all surfaces. Let stand for up to 10 minutes. Rinse instruments. As a pre-cleaning immersion solution Fill appropriate size container with a sufficient amount of Clorox Healthcare Bleach Germicidal Cleaner to completely submerge instruments. Place instruments into the container of Clorox Healthcare Bleach Germicidal Cleaner, cover, and allow to soak for up to 10 minutes. Remove and rinse, and follow with an appropriate cleaning and disinfecting process. Change solution daily. As a manual instrument cleaner Thoroughly pre-rinse dirty instruments under running water to remove visible, gross debris. Immerse pre-rinsed instruments into an appropriate size container filled with Clorox Healthcare Bleach Germicidal Cleaner. Scrub instruments using a stiff bristle brush until visibly clean. Submerge instruments while scrubbing. Rinse instruments thoroughly. Change solution daily. Follow with an appropriate disinfection process. Cleaning of critical and semi-critical devices must be followed by an appropriate terminal sterilization/high-level disinfection process. To Disinfect Non-Critical, Pre-Cleaned Instruments: Instruments must be thoroughly pre-cleaned to remove excess organic debris, rinsed, and rough dried. (Clean and rinse lumens of hollow instruments before filling with Clorox Healthcare Bleach Germicidal Cleaner or before immersion.) Immersion method Using a soaking tray, immerse instruments into Clorox Healthcare Bleach Germicidal Cleaner and let stand for one minute. Remove and wipe with a clean, damp cloth or paper towel and allow to air dry. Change solution for each use. Spray method Spray all surfaces of instruments with Clorox Healthcare Bleach Germicidal Cleaner until thoroughly wet. Let stand for one minute. To kill Clostridium difficile (), let stand for five minutes. Wipe with a clean, damp cloth or paper towel and allow to air dry. KILLS HIV, HBV, AND HCV ON PRE-CLEANED ENVIRONMENTAL SURFACES/OBJECTS PREVIOUSLY SOILED WITH BLOOD/BODY FLUIDS in healthcare settings or other settings in which there is an expected likelihood of soiling of inanimate surfaces/objects with blood/body fluids, and in which the surfaces/objects likely to be soiled with blood/body fluids can be associated with the potential for transmission of Human Immunodeficiency Virus Type 1 (HIV-1) (associated with AIDS), Hepatitis B Virus (HBV), and Hepatitis C Virus (HCV). Special Instructions for Cleaning and Decontamination Against HIV-1 (AIDS Virus), HBV and HCV on Surfaces/Objects Soiled with Blood/Body Fluids. Personal Protection: When handling items soiled with blood or body fluids, use disposable gloves, gowns, masks, and eye coverings. Cleaning Procedure: Blood and other body fluids must be thoroughly cleaned from surfaces and objects before applying this product. Contact Time: Let stand for one minute. For all other organisms, see directions for contact times. Disposal of Infectious Materials: Use disposable impervious gloves, gowns, masks and eye coverings. Blood and other body fluids must be autoclaved and disposed of according to local regulations for infectious waste disposal. This product is not to be used as a terminal sterilant/high level disinfectant on any surface or instrument that (1) is introduced directly into the human body, either into or in contact with the bloodstream or normally sterile areas of the body, or (2) contacts intact mucous membranes but which does not ordinarily penetrate the blood barrier or otherwise enter normally sterile areas of the body. This product may be used to preclean or decontaminate critical or semi-critical medical devices prior to sterilization or high level disinfection. Multipurpose, broad spectrum cleaner disinfectant for use in healthcare and other areas where control of cross contamination is required, especially during outbreaks of Clostridium difficile and other Healthcare Associated Infections (HAIs) listed on this label. Meets OSHA Bloodborne Pathogen Standards. May be used for instrument pre-cleaning and disinfection of non-critical instruments. SURFACES: May be used on hard, non-porous surfaces such as stainless steel, glazed ceramic tile, hard plastics, non-porous vinyl, laminated plastic 99.99% Bacteria, Viruses, Si usted no entiende la etiqueta, busque a alguien para que se la explique a usted en detalle. Clostridium difficile OTHER INGREDIENTS:...99.35% TOTAL:...100.00% countertops, fiberglass (sealed) surfaces, glazed porcelain, and glass. Medical hard, non-porous surfaces: autoclaves, blood glucose monitors, external surfaces of medical equipment, IV poles, exam tables, bed railing, external surfaces of dialysis machines, gurneys, mammography equipment, plastic mattress covers, external surfaces of respiratory equipment, stretchers, external surfaces of ultrasound transducers and probes, and wheelchairs. Dental hard, non-porous surfaces: chairs, counters, operatory hard surfaces, and light lens covers. Miscellaneous hard, non-porous surfaces: doorknobs, hand railings. USE SITES: Medical ambulance, critical care units, emergency rooms, exam rooms, hospitals, intensive care units, nurses stations, patient rooms, physician offices, and surgery rooms. Dental dental clinics, labs. For any use site that includes electronics, refer to manufacturers instructions before use. Efficacy tests have demonstrated that this product is an effective bactericide, virucide and fungicide in the presence of organic soil (5% blood serum). ORGANISMS: Carbapenem resistant Klebsiella Enterobacter cloacae - New Delhi Avian Influenza A (H3N2) Virus Canine Parvovirus Feline Panleukopenia Virus Hepatitis A Virus (HAV) Follow special instructions for cleaning prior to disinfection. ESBL (Extended Spectrum Beta Lactamase) producing Escherichia coli Methicillin resistant Staphylococcus ESBL (Extended Spectrum Beta Lactamase) aureus (MRSA) producing Klebsiella pneumoniae Multi-drug resistant Enterococcus Escherichia coli - New Delhi faecium Proteus mirabilis Klebsiella pneumoniae Pseudomonas aeruginosa Klebsiella pneumoniae - New Delhi Salmonella enterica Hepatitis B Virus (HBV) HIV-1 (AIDS Virus) Hepatitis C Virus (HCV) Influenza A H1N1 Herpes Simplex Virus Type 2 Influenza A Virus (HSV-2) Norovirus PRECAUTIONARY STATEMENTS: HAZARDS TO HUMANS AND DOMESTIC ANIMALS center or doctor, or going for treatment. PHYSICAL OR CHEMICAL HAZARDS: Do not use this product with ammonia or acids such as vinegar, rust removers, or toilet bowl cleaners. This product not intended for use on fabrics. For MSDS information, please go to www.cloroxhealthcare.com. A list of this product s ingredients is available at www.ingredientsinside.com. Mfd. for Clorox Professional Products Company, 1221 Broadway, Oakland, CA 94612. Clorox Healthcare is a registered trademark of The Clorox Company. 2014 Made in the U.S.A. EPA Reg. No. 56392-7. EPA Est. No. 8251-OH-1 (Q6); 5813-GA-1 (A4); GA-2 (VG). Beginning of batch code indicates Est. No. Serratia marcescens Streptococcus pyogenes Stenotrophomonas maltophilia Enterococcus faecium (VRE) Vancomycin intermediate resistant Staphylococcus aureus (VISA) Poliovirus Type 1 (Mahoney Strain) Rhinovirus Type 37 Rotavirus Trichophyton mentagrophytes (Athlete s Foot Fungus) Candida albicans 0 00000 00000 0 EPA Reg. No. 56392-7 Clorox Healthcare Bleach Germicidal Cleaner [64 oz] Page 1 of 3 Bleach Germicidal Cleaner 99.99% Bacteria, Viruses, Clostridium difficile Si usted no entiende la etiqueta, busque a alguien para que se la explique a usted en detalle. 2 QT (64 FL OZ) 1.89 L OTHER INGREDIENTS:...99.35% TOTAL:...100.00% R0966020 NI-25250 Shown on page 2 Shown on page 3 Bleach Germicidal Cleaner 2 QT (64 FL OZ) 1.89 L NI-25250 Causes moderate eye irritation. Avoid contact with eyes or clothing. Wash thoroughly with soap and water after handling. FIRST AID: If in Eyes: Hold eye open and rinse slowly and gently with water for 15 20 minutes. If present, remove contact lenses after the first 5 minutes, then continue rinsing eye. Call a poison control center or doctor for further treatment advice. Have the product container or label with you when calling a poison control STORAGE AND DISPOSAL: Store this product in a cool, dry area, away from direct sunlight and heat. Nonrefillable container. Do not reuse or refill this container. When discarding container, place in trash collection or take to recycling center. Do not contaminate water, food, or feed by storage and disposal. 56392-7_PPD_HC_BLGRM_Clnr_64oz_R0966020.indd 1 8/6/14 11:22 AM

EPA Reg. No. 56392-7 Clorox Healthcare Bleach Germicidal Cleaner [64 oz] Page 2 of 3 DIRECTIONS FOR USE: It is a violation of Federal Law to use this product in a manner inconsistent with its labeling. Always refer to manufacturer s care instructions before using on equipment or devices. To Refill Spray Bottles: Remove trigger sprayer from empty bottle. Unscrew cap on refill and pour contents directly into empty bottle. Replace trigger sprayer and use as you normally would. To Clean, Disinfect, and Deodorize in One Step: Spray 6" 8" from surface until surface is completely wet. To disinfect, let stand for one minute. Wipe with a clean, damp cloth or paper towel or allow to air dry. For food contact surfaces, rinse with potable water. For all other surfaces no rinsing is required. Gross soil must be removed prior to disinfecting. To Clean: Follow directions above or apply with a clean cloth, mop, or sponge saturated with Clorox Healthcare Bleach Germicidal Cleaner until surface is completely wet. (When applying with a saturated cloth or sponge, gloves should be worn.) No standing time is required. If streaking is observed, wipe with a clean, damp cloth or paper towel. Special Instructions for Cleaning Prior to Disinfection against Clostridium difficile. Personal Protection: Wear appropriate barrier protection such as gloves, gowns, masks, or eye covering. Cleaning Procedure: Fecal matter/waste must be thoroughly cleaned from surfaces/objects before disinfection by application with a clean cloth, mop, and/or sponge saturated with this product. Cleaning is to include vigorous wiping and/or scrubbing, until all visible soil is removed. Special attention is needed for high-touch surfaces. Surfaces in patient rooms are to be cleaned in an appropriate manner, such as from right to left or left to right, on horizontal surfaces, and top to bottom, on vertical surfaces, to minimize spreading of the. Restrooms are to be cleaned last. Do not reuse soiled cloths. Infectious Materials Disposal: Materials used in the cleaning process that may contain feces/wastes are to be disposed of immediately in accordance with local regulations for infectious materials disposal. Disinfection Procedure: Spray 6" 8" from surface until surface is completely wet. Let stand for 5 minutes. Wipe with a clean, damp cloth or paper towel or allow to air dry. To Preclean Instruments Prior to Terminal Sterilization/High Level Disinfection: As a pre-cleaning spray Place instruments into a suitable container. Spray Clorox Healthcare Bleach Germicidal Cleaner onto instruments to thoroughly wet all surfaces. Let stand for up to 10 minutes. Rinse instruments. As a pre-cleaning immersion solution Fill appropriate size container with a sufficient amount of Clorox Healthcare Bleach Germicidal Cleaner to completely submerge instruments. Place instruments into the container of Clorox Healthcare Bleach Germicidal Cleaner, cover, and allow to soak for up to 10 minutes. Remove and rinse, and follow with an appropriate cleaning and disinfecting process. Change solution daily. As a manual instrument cleaner Thoroughly pre-rinse dirty instruments under running water to remove visible, gross debris. Immerse pre-rinsed instruments into an appropriate size container filled with Clorox Healthcare Bleach Germicidal Cleaner. Scrub instruments using a stiff bristle brush until visibly clean. Submerge instruments while scrubbing. Rinse instruments thoroughly. Change solution daily. Follow with an appropriate disinfection process. Cleaning of critical and semi-critical devices must be followed by an appropriate terminal sterilization/high-level disinfection process. To Disinfect Non-Critical, Pre-Cleaned Instruments: Instruments must be thoroughly pre-cleaned to remove excess organic debris, rinsed, and rough dried. (Clean and rinse lumens of hollow instruments before filling with Clorox Healthcare Bleach Germicidal Cleaner or before immersion.) Immersion method Using a soaking tray, immerse instruments into Clorox Healthcare Bleach Germicidal Cleaner and let stand for one minute. Remove and wipe with a clean, damp cloth or paper towel and allow to air dry. Change solution for each use. Spray method Spray all surfaces of instruments with Clorox Healthcare Bleach Germicidal Cleaner until thoroughly wet. Let stand for one minute. To kill Clostridium difficile (), let stand for five minutes. Wipe with a clean, damp cloth or paper towel and allow to air dry. KILLS HIV, HBV, AND HCV ON PRE-CLEANED ENVIRONMENTAL SURFACES/OBJECTS PREVIOUSLY SOILED WITH BLOOD/BODY FLUIDS in healthcare settings or other settings in which there is an expected likelihood of soiling of inanimate surfaces/objects with blood/body fluids, and in which the surfaces/objects likely to be soiled with blood/body fluids can be associated with the potential for transmission of Human Immunodeficiency Virus Type 1 (HIV-1) (associated with AIDS), Hepatitis B Virus (HBV), and Hepatitis C Virus (HCV). Special Instructions for Cleaning and Decontamination Against HIV-1 (AIDS Virus), HBV and HCV on Surfaces/Objects Soiled with Blood/Body Fluids. Personal Protection: When handling items soiled with blood or body fluids, use disposable gloves, gowns, masks, and eye coverings. Cleaning Procedure: Blood and other body fluids must be thoroughly cleaned from surfaces and objects before applying this product. Contact Time: Let stand for one minute. For all other organisms, see directions for contact times. Disposal of Infectious Materials: Use disposable impervious gloves, gowns, masks and eye coverings. Blood and other body fluids must be autoclaved and disposed of according to local regulations for infectious waste disposal. This product is not to be used as a terminal sterilant/high level disinfectant on any surface or instrument that (1) is introduced directly into the human body, either into or in contact with the bloodstream or normally sterile areas of the body, or (2) contacts intact mucous membranes but which does not ordinarily penetrate the blood barrier or otherwise enter normally sterile areas of the body. This product may be used to preclean or decontaminate critical or semi-critical medical devices prior to sterilization or high level disinfection. Multipurpose, broad spectrum cleaner disinfectant for use in healthcare and other areas where control of cross contamination is required, especially during outbreaks of Clostridium difficile and other Healthcare Associated Infections (HAIs) listed on this label. Meets OSHA Bloodborne Pathogen Standards. May be used for instrument pre-cleaning and disinfection of non-critical instruments. SURFACES: May be used on hard, non-porous surfaces such as stainless steel, glazed ceramic tile, hard plastics, non-porous vinyl, laminated plastic R0966020 56392-7_PPD_HC_BLGRM_Clnr_64oz_R0966020.indd 2 8/6/14 11:22 AM

EPA Reg. No. 56392-7 Clorox Healthcare Bleach Germicidal Cleaner [64 oz] Page 3 of 3 countertops, fiberglass (sealed) surfaces, glazed porcelain, and glass. Medical hard, non-porous surfaces: autoclaves, blood glucose monitors, external surfaces of medical equipment, IV poles, exam tables, bed railing, external surfaces of dialysis machines, gurneys, mammography equipment, plastic mattress covers, external surfaces of respiratory equipment, stretchers, external surfaces of ultrasound transducers and probes, and wheelchairs. Dental hard, non-porous surfaces: chairs, counters, operatory hard surfaces, and light lens covers. Miscellaneous hard, non-porous surfaces: doorknobs, hand railings. USE SITES: Medical ambulance, critical care units, emergency rooms, exam rooms, hospitals, intensive care units, nurses stations, patient rooms, physician offices, and surgery rooms. Dental dental clinics, labs. For any use site that includes electronics, refer to manufacturers instructions before use. Efficacy tests have demonstrated that this product is an effective bactericide, virucide and fungicide in the presence of organic soil (5% blood serum). ORGANISMS: Carbapenem resistant Klebsiella Enterobacter cloacae - New Delhi Avian Influenza A (H3N2) Virus Canine Parvovirus Feline Panleukopenia Virus Hepatitis A Virus (HAV) ESBL (Extended Spectrum Beta Lactamase) producing Escherichia coli ESBL (Extended Spectrum Beta Lactamase) producing Klebsiella pneumoniae Escherichia coli - New Delhi Klebsiella pneumoniae Klebsiella pneumoniae - New Delhi Hepatitis B Virus (HBV) Hepatitis C Virus (HCV) Herpes Simplex Virus Type 2 (HSV-2) Follow special instructions for cleaning prior to disinfection. Methicillin resistant Staphylococcus aureus (MRSA) Multi-drug resistant Enterococcus faecium Proteus mirabilis Pseudomonas aeruginosa Salmonella enterica HIV-1 (AIDS Virus) Influenza A H1N1 Influenza A Virus Norovirus Serratia marcescens Streptococcus pyogenes Stenotrophomonas maltophilia Vancomycin intermediate resistant Staphylococcus aureus (VISA) Poliovirus Type 1 (Mahoney Strain) Rhinovirus Type 37 Rotavirus Enterococcus faecium (VRE) Trichophyton mentagrophytes (Athlete s Foot Fungus) Candida albicans NI-25250 PRECAUTIONARY STATEMENTS: HAZARDS TO HUMANS AND DOMESTIC ANIMALS Causes moderate eye irritation. Avoid contact with eyes or clothing. Wash thoroughly with soap and water after handling. FIRST AID: If in Eyes: Hold eye open and rinse slowly and gently with water for 15 20 minutes. If present, remove contact lenses after the first 5 minutes, then continue rinsing eye. Call a poison control center or doctor for further treatment advice. Have the product container or label with you when calling a poison control center or doctor, or going for treatment. PHYSICAL OR CHEMICAL HAZARDS: Do not use this product with ammonia or acids such as vinegar, rust removers, or toilet bowl cleaners. This product not intended for use on fabrics. STORAGE AND DISPOSAL: Store this product in a cool, dry area, away from direct sunlight and heat. Nonrefillable container. Do not reuse or refill this container. When discarding container, place in trash collection or take to recycling center. Do not contaminate water, food, or feed by storage and disposal. For MSDS information, please go to www.cloroxhealthcare.com. A list of this product s ingredients is available at www.ingredientsinside.com. Mfd. for Clorox Professional Products Company, 1221 Broadway, Oakland, CA 94612. Clorox Healthcare is a registered trademark of The Clorox Company. 2014 Made in the U.S.A. EPA Reg. No. 56392-7. EPA Est. No. 8251-OH-1 (Q6); 5813-GA-1 (A4); GA-2 (VG). Beginning of batch code indicates Est. No. R0966020 0 00000 00000 0 56392-7_PPD_HC_BLGRM_Clnr_64oz_R0966020.indd 3 8/6/14 11:22 AM

EPA Reg. No. 56392-7 Clorox Healthcare Bleach Germicidal Cleaner [128 oz] Page 1 of 2 Bleach Germicidal Cleaner 99.99% Bacteria, Viruses, Clostridium difficile Optional graphics. May be placed anywhere on label/container or collateral labeling. DISPATCH Si usted no entiende la etiqueta, busque a alguien para que se la explique a usted en detalle. 1 GALLON (128 FL OZ) 3.78 L OTHER INGREDIENTS:...99.35% TOTAL:...100.00% R0921030 NI-25251 IS NOW 56392-7_PPD_HC_BLGRM_Clnr_128oz_R0921030.indd 1 8/6/14 11:31 AM