I.V. INJECTION ARM P50/1 ( ) USER MANUAL

Similar documents
Procedure 30 Collecting A Blood Specimen Using The Vacuum-Tube System. Procedure 31 Collecting A Blood Specimen Using A Needle And Syringe

Operating Instructions

Operating Instructions

POWERGLIDE TITANIUM FEATURES

Appendix L: Accessing/Deaccessing Implanted Central Venous Access Port

EnglisH introduction general description (Fig. 1) Preparing for use Charging

Instructions for Use BYDUREON (by-dur-ee-on) Single-Dose Tray (exenatide extended-release) for injectable suspension

PRODUCTS FOR MEDICAL USE MESOTHERAPY PRODUCTS HYPODERMIC EXTRA-THIN NEEDLES MICRO-MESOTHERAPY AESTETHIC SURGERY MEDICAL SPRAY ELECTROLIPOLYSIS

Lenis Needle-free Safety Syringe Device User Manual

Original Date:

Migraine Attack Abortive Treatment Medication Overuse Protocol Treatment Refractory Cluster Headache Treatment

TRANSGENDER HEALTH Injection Guide

VALUE, QUALITY & PERFORMANCE distinguish these airbrushes!

Implantable Venous Port

PrecisionCut Hair Clipper

Student Performance Guide. Student Performance Guide. Student Performance Guide. Student Performance Guide. LESSON 3-3 Bleeding Time

MACO PRO-DOOR DOOR HINGES


AT Canon ip3000 CISS Instruction

Home Security Begins at the Front Door

Congratulations on your purchase of a. airbrush.

8-in-1 All Over Grooming Kit

BASIC GERi THE NURSING SKILLS MANIKIN LF04040U INSTRUCTION MANUAL

REVOLUTION M SERIES MANUAL & PARTS GUIDE

BodyBare AquaSmooth. Instruction Booklet. wet & dry epilator AP17SR. Please read these instructions carefully and retain for future reference.

MAINTAINING YOUR WINDOWS AND PATIO DOORS. Routine Maintenance * Cleaning of glass, frame and hardware 2. Glass Replacement 3.

Congratulations on your purchase of a. airbrush. CN GRAVITY-FEED DUAL-ACTION AIRBRUSH. color cup. main lever. needle cap. nozzle cap.

MEDICATION AND INJECTION ADMINISTRATION EDUCATIONAL BOOKLET FOR OVULATION INDUCTION

Gotcha. Instruction Sheet. Parts. Instructions For Hanging

Model #7650 Instruction Manual Patent Pending

Instructions For Use:

Home Security Begins at the Front Door

PDOB-II-GRM-NSF Ice Shaver. Specially designed for making shaved snow! User s Manual. Brought to you by SAC Food Supplies

ITEMS INCLUDED INSTALLATION INSTRUCTIONS

Cordless Ceramic Hair Cutting Set

Urine Collection Kit. just between us. This kit contains: Before you begin! Access Key label here

Installation Guidelines

T-SONIC FACIAL CLE ANSING & MASSAGING DEVICE

Charging base. Trimming head (30mm) on charging stand. Main body unit. On/Off switch. Indicated light. Connecting jack Connecting jack

Liner Take-Up Option/Maintenance Kit

Assembly Instructions

BodyBare Perfection. Instruction Booklet. cordless epilator & shaver with manual precission tweezers AP17LTR

Multi-Venous Access Arm Kit. Directions for Use

For Pricing and Ordering Please Call

WILLOWWOOD ONE TRANSTIBIAL SYSTEM

Professional Manicure & Pedicure Kit

Loading HepaSphere Microspheres with Lyophilized Doxorubicin

PHABA - PLASTIC PACKAGING SOLUTIONS - BOTTLES STANDARD LINE TALCUM POWDER LINE

HQ6990, HQ6970, HQ6950, HQ6920 CHARGE

How to Give a Subcutaneous (SC) Injection to Your Child

YOUR PUMP YOUR STYLE YOUR WAY

YOUR PUMP YOUR STYLE YOUR WAY

Airless Packaging Solutions

Home Care for Your Wound Drain

Revised 1/10. Copyright 2010 St. Jude Children's Research Hospital Page 1 of 5


Beard Trimmer. 10,000 prize draw. Register online for MB4130. EXTRA year guarantee FREE rewards gallery

Figure A. Figure B To prevent premature activation of the needle safety guard, do not touch the NEEDLE GUARD ACTIVATION CLIPS at any time during use.

ISO Sharps injury protection Requirements and test methods Sharps containers

PROFESSIONAL 6-IN-1 GROOMING KIT

Philosophy Body Products relax Pharma und Kosmetik GmbH,

Package Leaflet Information for the User ILUBE 5% w/v eye drops, solution. Acetylcysteine

Instructions for Use. (dulaglutide) injection, for subcutaneous use. 1.5 mg/0.5 ml Single-Dose Pen. once weekly. Unfold and lay flat

Video Doorbell Pro 1

Lip Hyaluronic Acid Deep Infusion System

COMPLETE MEN S SKINCARE ON THE GO!

Vacuum 5 in 1 Grooming Kit

Infection Prevention Guidelines. Safe Use, Handling & Disposal of Sharps

Metal And Canvas Double Robe

E-Blotter Operation. Technical Bulletin E-03 MATERIAL PROCEDURE

CN BCN Operating Instruction Manual

28145_HKVAC_IB 9/1/05 10:14 AM Page 1 VACUUM TRIM. Use and Care Guide HKVAC-2000

SM ART FAC IA L CLEANSING & MASSAGING BRUSH

SOP. Doc. No: Date: ASUSTeK COMPUTER INC. Pegasus P Assembly & Disassembly. Disassembly / Assembly Procedure. Recommended Tools.

Application Snap Lock. Selection. Standing Seam Clips. Engineered panel clips For standing seam panel attachments. Continued on following page

GETTING COMFORTABLE WITH TAKING STELARA

Instructions For Use PRALUENT (PRAHL-u-ent) (alirocumab) Injection, for Subcutaneous Injection Single-Dose Pre-Filled Pen (75 mg/ml)

THE WORLD S MOST INTELLIGENT FACIAL CLEANSING BRUSH

Home Care for Your Wound Drain After Breast Cancer Surgery

VERSATILITY, RELIABILITY & PERFORMANCE distinguish these airbrushes as Eclipse!

LOW COST HIGH QUALITY

Western Blotting Systems CAT NO:EPS-B0015 & EPS-B0016

HAIR AND BEARD. HAIR AND BEARD CLIPPERs. Operation and Safety Notes

B-SERIES CONVERSION INSTRUCTIONS

LADY SHAVER WASHABLE LS 7140

CT, MRI & Interventional Products

GOAL GATHER SUPPLIES CHANGE YOUR DRESSING CALL YOUR HEALTHCARE PROVIDER:

Infection Prevention PROTECTION FROM HEAD TO TOE

AST CLEANSING BRUSH USER MANUAL

AT920. Always here to help you. Rechargeable Cordless Tripleheader Razor. Register your product and get support at

SPECIMEN COLLECTION. A Study Guide

Rechargeable Tripleheader Cordless/Cord Razor 8240XL 8250XL 8251XL. Model 8240XL. Register your product and get support at

Fruit and Vegetable mask in 3 minutes

AT895 AT875 AT830. Rechargeable Cordless Tripleheader Razor. Register your product and get support at

#74 - CHANGING A MOIST TO DRY DRESSING (TEST)

Handbook TPE repair kit "comfort"

Standard Laboratory Practice for Consumer Applied Pet Stain and Odor Removal Chemical Evaluation on Pile Yarn Floor Coverings

Quality home healthcare products you can trust.

Administering ORENCIA (abatacept): Your Step-by-Step Guide

Policy: C-08-PRO Reviewed: 7/08

Transcription:

I.V. INJECTION ARM P50/1 (1021418) USER MANUAL

The I.V. Injection Arm P50/1 is an educational system developed to assist a certified instructor. It is not a substitute for a comprehensive understanding of the subject matter and not intended for clinical decision making. Congratulations, you have acquired a 3B Scientific quality product. The I.V. Injection Arm P50/1 is made of 3B SKINlike silicone. The injection arm can be used to train the following: Intravenous injections Punctures of the peripheral veins [basilic v., cephalic v., median cubital v., hand (dorsal venous network)] Positioning of a butterfly catheter CONTENTS OF THE I.V. INJECTION ARM P50/1 The trainer consist of an adult arm with a simulated vein system covered with a removable skin. The arm and the infusion system is supported by a stand. 1 injection arm 1 infusion bottle with a tube locking clip and a Y-tube connector 1 stand 1 bottle of 3B Scientific artificial blood concentrate (250ml) 1 plastic cup 1 disposable syringe 2 injection cannulas (recommended cannula size: 20 and 21 gauge) 2 tubing systems with 2 transparent tube connectors and 2 tube locking clips as replacement parts 1 container of talcum powder 2

INSTRUCTION FOR USE Filling of the infusion bottle with the blood 1 2 3 1. Make sure that the locking clip of the ventilation tube of the infusion bottle is locked 2. Fill the infusion bottle up to the red line with the artificial blood concentrate 3. Then fill the infusion bottle up to the blue line with water 4. Close the bottle and shake gently to obtain a homogeneous solution. Installation of the infusion system 3 5 8 1. Fasten the hanging hook at the middle of the stand 2. Hang the injection arm onto the hanging hook using the arm ring screw 3. Connect the shorter injection tube to the infusion bottle 4. Make sure that the locking clip of the longer tube is locked 5. Attach the infusion bottle upside down to the retaining clip by pushing the sealing cap of the bottle sideways into the grey retaining clip of the stand. 6. Insert the longer tube in the plastic cup and allow the blood to flow into the cup for a short time to remove any bubbles 7. After checking that all the connections are correctly placed and that the longer tube is in the plastic cup, open the locking clip on the ventilation tube of the infusion bottle and the locking clip of the longer tube 3

9 10a 10b 8. The system will then be filled up and blood will start to flow out of the longer tube in the plastic cup. Let the blood flow out until you see no more bubbles coming out from the longer tube 9. Close the locking clip of the longer tube and connect it to one branch of the Y-connector on the infusion bottle 10. You can now start puncturing the peripheral veins. After using of the Injection arm To remove the artificial blood after use please follow the following steps: 1. Make sure that the locking clip of the ventilation tube of the infusion bottle is closed 2. Make sure that the locking clip of the longer tube is closed 3. Disconnect the longer tube from the Y-connector 4. Remove the infusion bottle from the stand retaining clip and turn the bottle upright 5. Disconnect the shorter tube from the bottle connector by gently unscrewing the connector 6. Put the ends of the tubes in a container or bucket in order to remove the remaining blood in the tubing system If you are not using the injection arm for a prolonged period of time, it is recommended to rinse the complete tubing system so that no dye residues can settle in the system. Please fill water into the infusion bottle and repeat the all installation steps in order to clean the system. CHANGING THE SKIN AND THE TUBING SYSTEM How to change the tubing system 1. To change the tubing system you first need to remove the skin. Please remove first the transparent tube connector from the shorter tube and remove the locking clip from the longer tube 2. Unscrew the ring screw and open the two parts of arm sealing caps 2a 2b 2c 4

3 4 5 3. Starting at the top of the arm, roll the skin off the arm core 4. Unfasten the Velcro strips and remove the tubing system from the arm core 5. Fit the new tubing system into the provided grooves and refasten it using the Velcro strips. How to put back the skin 1. The new skin can be pulled over the hand and arm core by putting some talcum powder onto the skin and distributing the powder by moving the skin back-and-forth 2. Pull the skin over the hand core and arm core, put the tube back through the location hole and the cover plates. The rim of the skin should be closed between the two cover plates. Fasten the ring screw and replace the sealing caps onto the tubes 3. Please don t forget to plug back the transparent tube connector on the shorter tube and to reinstall the locking clip on the longer tube. PLEASE NOTE THE FOLLOWING The skin and the tubing system of the injection arm are subject to wear and tear caused by usage. We supply the skin and the tubing system as a replacement parts. As the injection arm is an anatomical model, several non-puncturable veins are portrayed in the skin in addition to the puncturable veins. The artificial blood may cause stains. But don't worry, stains caused by the 3B Scientific artificial blood can be washed out at 40 C. Indwelling vein cannulas may damage the material of the skin and of the tubing system. Please use injection cannulas of the recommended size (20 or 21 gauge) only and change the skin or the tubing system when damages of the skin become visible. PRODUCT NUMBERS FOR REPLACEMENT PARTS Product Reference Intern Reference Description 1021419 (XP50/1-002) Puncture accessories 1021422 (XP50/1-003) Arm and hand core Composition 1 Tubing System 1 Tube Connector 1 Tube Locking Clip 1 Disposable Syringe 2 Injection Cannulas 20 and 21 Gauge 1 Plastic Cup 1 Arm Core 1 Hand Core 1021423 (XP50/1-004) Infusion bottle 1 Infusion Bottle 1021425 (XP50/1-005) Stand 1 Stand 1021426 (XP50/1-006) Replacement skin without core 1021427 (XP50/1-007) 3 Tubing Systems 1 3B SKINlike Silicone Arm Skin 1 Container of Talcum Powder 3 Tubing System 3 Tube Connector 3 Tube Locking Clip 1021251 (XP110) Artificial Blood Concentrate 250 ml Bottle CONTACTING 3B SCIENTIFIC When contacting technical support, please have your simulation product and manual available. 5

A worldwide group of companies UK 3B Scientific Limited Suite 1, Formal House, Oldmixon Crescent Weston-super-Mare BS24 9AY Phone: 01934 425333 Fax: 01934 425334 3bscientific.com uk3bs@3bscientific.com Copyright 2018 for instruction manual and design of product: 3B Scientific GmbH, Germany